• 제목/요약/키워드: fire accidents

Search Result 754, Processing Time 0.032 seconds

Study fo the Characteristics Analysis of Laboratory Chemical Accidents (실험실 화학사고 특성 분석에 관한 연구)

  • Lee, Tae-Hyung;Lee, Deok-Jae;Park, Joong-Don;Shin, Chang-Hyun
    • Fire Science and Engineering
    • /
    • v.30 no.3
    • /
    • pp.110-116
    • /
    • 2016
  • The major aim of this study was to provide information on the chemical accidents that occurred in laboratories over the last 3 years. The total incidence of laboratory chemical accidents was 30 cases; 25 cases occurred at educational institutions. Most accidents (19 cases) occurred due to spills and leaks. The main cause of the accidents analyzed was worker carelessness (21 cases). Twenty-two accidents were related to hazardous chemical substances. In addition, general chemical substances as well as waste liquid contributed 26% to the incidents related to the laboratory. Among the 22 hazardous chemical substances involved in laboratory chemical accident, 67% of accident substances were accident preparedness substances.

Prediction Principle and System Structure for the Detection of Incipient Electrical Fire (전기화재 예지원리 및 징후검출 시스템 구조)

  • 김창종
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.9 no.4
    • /
    • pp.71-77
    • /
    • 1995
  • Electrical fire in residential, commercial, and industrial areas occupies 40 percent of overall fire accidents as of the year of 1994. The causes of most electrical fires were studied and, based on this investigation, the principle of the early detection or prediction of the electrical fires is developed. The basic principle is to early detect electrical arcs or sparks caused by faulty connections and insulation failures. the structure of the prediction system based on microcontroller technique is presented.

  • PDF

Field Experiments on Performance Evaluation of Pressure Differential System for Smoke Management (급기가압 제연시스템의 현장 성능평가 연구)

  • Kim, Jung-Yup;Rie, Dong-Ho;Kim, Ha-Young
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.251-254
    • /
    • 2008
  • The fact that the major cases of life casualties are from smoke in the fire accidents and the expected steep increase of skyscrapers, huge spaces, multiplexes and huge scaled underground spaces demand establishment of efficient smoke countermeasure. The field experiments on two high buildings of 20 stories and 21 stories are carried out to evaluate the field performance of pressure differential systems for smoke management and the results of experiments are presented.

  • PDF

Analysis of Electric Shock Accident on 4.16 kV Class Circuit breaker for Power Plant (발전소용 4.16 kV급 차단기에서 감전사고 사례 분석)

  • Park, Nam-Kyu;Song, Jae-Yong;Kim, Jin-Pyo;Goh, Jae-Mo
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.4
    • /
    • pp.54-60
    • /
    • 2014
  • This paper describes electric shock accidents on a 4.16 kV class circuit breaker for power plant. Electric shock accidents mostly involve damage of human life, in comparison with electrical fire, rate of human death tend to be higher in electric shock accidents. Specially, in a high voltage facilities rate of human death comprised about 43.7% by electric shock accidents. If electric shock accidents happen in a 4.16 kV class circuit breaker for power plant, then the power plant discontinue power production. Electric shock accidents in a power plant have a great ripple effect such as an electric power shortage. In this paper, we analyzed electric shock accidents on a 4.16 kV class circuit breaker for power plant. From the analysis results, we confirmed a cause of electric shock accidents on a 4.16 kV class circuit breaker, it happened by defect of interlock equipment or occurrence of breakdown between first feeder contactor and shielding plate. In order to reduce electric shock accidents on a 4.16 kV class circuit breaker, the power plant should consider improvement of interlock equipment and insulation of feeder contactor in circuit breaker.

Fire Accident Analysis of Hazardous Materials Using Data Analytics (Data Analytics를 활용한 위험물 화재사고 분석)

  • Shin, Eun-Ji;Koh, Moon-Soo;Shin, Dongil
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.5
    • /
    • pp.47-55
    • /
    • 2020
  • Hazardous materials accidents are not limited to the leakage of the material, but if the early response is not appropriate, it can lead to a fire or an explosion, which increases the scale of the damage. However, as the 4th industrial revolution and the rise of the big data era are being discussed, systematic analysis of hazardous materials accidents based on new techniques has not been attempted, but simple statistics are being collected. In this study, we perform the systematic analysis, using machine learning, on the fire accident data for the past 11 years (2008 ~ 2018), accumulated by the National Fire Service. The analysis results are visualized and presented through text mining analysis, and the possibility of developing a damage-scale prediction model is explored by applying the regression analysis method, using the main factors present in the hazardous materials fire accident data.

Fire Occurrence Pattern Analysis and Fire Risk Calculation of Jinju City (진주시 화재발생 패턴분석과 위험등급 산출)

  • Bae, Gyu Han;Yoo, Hwan Hee
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.22 no.4
    • /
    • pp.151-157
    • /
    • 2014
  • Diverse and complex facilities have been on the increase in urban areas in accordance with rapid urbanization. Along the lines of the increase in facilities, the risk of fire has increased. In particular, fire accidents as well as traffic accidents accounted for the highest rate in artificial disasters. Therefore, the National Fire Information Systems managed by the National Emergency Management Agency (NEMA) appeared for the effective fire management. The NEMA has provided the public with the Internet services regarding information about fire outbreak since 2007. This study acquired data from both NEMA and the Jinju City Fire Department. It constructed the fire data of Jinju City and calculated the change in spatial density targeting fire, occurred in Jinju city with a view to examining the fire risk of facilities by conducting a time series analysis on the trends of fire outbreak over a span of periods between 2007 and 2013. It also conducted an analysis of Moran's I, Getis-Ord Gi. Therefore, it came to select higher hot spots in terms of fire location and fire density. In addition, it attempted to calculate the levels of fire hazard by drawing up the matrix of personal injury and property damage, depending on facilities to present the methods, which can predict the risk of fire occurrence in urban areas.

Fire Detection Using Multi-Channel Information and Gray Level Co-occurrence Matrix Image Features

  • Jun, Jae-Hyun;Kim, Min-Jun;Jang, Yong-Suk;Kim, Sung-Ho
    • Journal of Information Processing Systems
    • /
    • v.13 no.3
    • /
    • pp.590-598
    • /
    • 2017
  • Recently, there has been an increase in the number of hazardous events, such as fire accidents. Monitoring systems that rely on human resources depend on people; hence, the performance of the system can be degraded when human operators are fatigued or tensed. It is easy to use fire alarm boxes; however, these are frequently activated by external factors such as temperature and humidity. We propose an approach to fire detection using an image processing technique. In this paper, we propose a fire detection method using multichannel information and gray level co-occurrence matrix (GLCM) image features. Multi-channels consist of RGB, YCbCr, and HSV color spaces. The flame color and smoke texture information are used to detect the flames and smoke, respectively. The experimental results show that the proposed method performs better than the previous method in terms of accuracy of fire detection.

A Study on Fire Prevention Requirements and Tests for Small Aircraft (소형항공기의 화재방지 요건 및 시험에 관한 연구)

  • Yoo, Seung-Woo;Jin, Young-Kwon
    • Journal of Aerospace System Engineering
    • /
    • v.5 no.1
    • /
    • pp.7-12
    • /
    • 2011
  • The goal of fire prevention research is to eliminate fires as a cause of fatal accidents and there are two main areas of research. One is to prevent flame propagation during in-flight and it addresses fire hazards. The other is to minimize the possibility of flame penetration or fuselage burn-through and it aims toward post-crash survival include crash protection, emergency evacuation and post-evacuation survival. Civil aviation authorities world-wide are trying to identify threats and measure performance for fire prevention. The results of research are standardized and given as general directions of test methods. This paper has prepared to study and present the means of compliance to the fire prevention requirements and applicable test methods.

Prediction of Marine Accident Frequency Using Markov Chain Process (마코프 체인 프로세스를 적용한 해양사고 발생 예측)

  • Jang, Eun-Jin;Yim, Jeong-Bin
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2019.11a
    • /
    • pp.266-266
    • /
    • 2019
  • Marine accidents are increasing year by year, and various accidents occur such as engine failure, collision, stranding, and fire. These marine accidents present a risk of large casualties. It is important to prevent accidents beforehand. In this study, we propose a modeling to predict the occurrence of marine accidents by applying the Markov Chain Process that can predict the future based on past data. Applying the proposed modeling, the probability of future marine accidents was calculated and compared with the actual frequency. Through this, a probabilistic model was proposed to prepare a prediction system for marine accidents, and it is expected to contribute to predicting various marine accidents.

  • PDF

Study on Improvement of Fire Investigation System (화재조사제도 개선방안에 관한 연구)

  • Ko, Gi-Bong;Lee, Si-Young
    • Fire Science and Engineering
    • /
    • v.23 no.2
    • /
    • pp.101-110
    • /
    • 2009
  • As the current fire investigation system in Korea has been performed mainly by the public sector such as fire service, police, etc., private fire investigation system such as 'private fire investigator system' to protect rights and interests of the sufferers from the fire accidents due to defective products showed very deficient. In addition, since the laws and regulations concerned about fire investigation are distributed into and applied for each organization, a lot of problems have been generated such as civil appeals due to duplicated investigations among similar organizations, excess reaction to exclude other organization from the fire investigation field, inefficient waste of administration force due to duplicated operation of fire investigation organization and manpower, etc. This study has surveyed generation operation conditions and problems of the fire investigation system in Korea and drawn its improvement method on the public and private sectors.