• Title/Summary/Keyword: finishing material

Search Result 665, Processing Time 0.032 seconds

A study of the interior finishing materials for improving residential environment (주거환경 개선을 위한 실내 마감재에 관한 연구)

  • Kwak, Jae-Hoon;Han, Hae-Ryon
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2005.05a
    • /
    • pp.207-211
    • /
    • 2005
  • This research is aimed to study the finishing material applied in interior space for improving residential environment. First of all, it finds out what is 'Sick Building Syndrome' and 'Sick House Syndrome', how harmful to human body about indoor air pollution substance (such as volatility organic compound, formaldehyde) and investigate the effect when the environment-friendly finishing material is used. Secondly, classify and examine all kind of finishing material applied in interior space. Finally, after emphasize the importance of environment-friendly finishing material from domestic or overseas, this research suggest the basic information of environment-friendly finishing material in order to use in the future buildings.

  • PDF

A Finish Material Management Process for Indoor Air Quality -Focused on Apartment Buildings- (실내 공기질을 고려한 마감자재 선정 프로세스 연구 -공동주택을 중심으로-)

  • Kwon, Gi-Deoc;Lee, Dong-Hoon;Lee, Sung-Ho;Zheng, Qi;Kim, Sun-Kuk
    • KIEAE Journal
    • /
    • v.10 no.6
    • /
    • pp.123-130
    • /
    • 2010
  • Indoor air quality has attracted great attention in recent years and thus the importance of managing finishing materials in terms of pollutant source control is being emphasized. Managing the finishing material at the design stage maximizes the efficiency of IAQ control at the following construction stage. However, there are insufficient investigations on the application of a specific finishing material management process, a database management system or a finishing material management process network. As a result, the main purposes of this study comprise comprehensive evaluation of IAQ performance from the selected finishing materials and auxiliary materials, application of the material management system basing on the types and characteristics of toxic substances generated from the indoor finishing materials, investigation of IAQ evaluation standard, and the overall IAQ evaluation method for the design parts. The result of this study will be the basic data to construct DBMS for management of finishing materials with respect to IAQ.

Optimization of real-time path finding for material handling of finishing work considering the logistics flow (물류량을 고려한 마감공사 자재운반의 실시간 경로탐색 최적화 연구)

  • Kim, Wansoub;Lee, Dongmin;Kim, Taehoon;Cho, Hunhee;Kang, Kyung-In
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.11a
    • /
    • pp.170-171
    • /
    • 2015
  • Resource procurement and material handling are considered as a significant part of construction project especially in large or tall building construction site. There are multiple variables that must be considered in a construction site during finishing work such as movement of materials, equipments, and workers. Therefore, it is difficult for construction workers to find the material handling path solely by intuition. The aim of this study is to propose a real-time path finding model suitable for complicated logistics flow in the field. The model explores the optimal transport path of finishing material with its basis on optimization algorithm, and it determines the direction of the Smart Sign. The proposed model is expected to be utilized for planning of efficient finishing material handling.

  • PDF

The Economic Feasibility of Building-Integrated Photovoltaics System Installed on the Roof of Residential Building - Focused on Comparison with Construction Cost of BAPV System Depend on Roof Finishing Materials

  • Oh, Byung-Chil
    • KIEAE Journal
    • /
    • v.17 no.1
    • /
    • pp.15-21
    • /
    • 2017
  • Purpose: This study was on the economic feasibility of BIPV system, focused on comparison with construction cost of BAPV system depend on roof finishing materials, and to suggest basic data on the construction cost. Method: Construction cost of BAPV system was calculated, by selecting asphalt single, flat type roof tile, color steel plate, titanium zinc plate as roof finishing material of residential building and by sum up each cost for roof finishing construction and cost for 3kWp-volumed PV module installation. Also, the economic feasibility was analysed quantitatively by comparing the cost for BIPV system construction, installing same volumed PV module instead of roof finishing materials. Result: 1. By installing BIPV system instead of the roof finishing material, the cost of construction falls ; about 19% in case of the titanium zinc plate, which is the most expensive, and about 11% in case of the color steel plate. 2. Reducing amount of the construction cost gets larger because of installing BIPV module instead of the roof finishing material, as the construction cost for roof finishing material gets higher ; therefore, it is more economical than BAPV system in terms of whole cost of construction.

An experimental study on thermal performance evaluation of PCM mixed coating material constructed in and out of the wall (벽체 내·외부에 시공한 PCM혼입 도료의 열적성능 평가에 관한 실험적 연구)

  • Ju, Dong-Uk;Shin, Sang-Heon;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.216-217
    • /
    • 2014
  • Optimum finishing position, thickness and phase change temperature of winter and summer season were selected and suitability of finishing materials was evaluated based on temperature measurement of specimens applying the coating material mixed phase change materials(PCM). As a result, when finishing position was interior and finishing thickness of coating material mixed n-Octadecane(28℃ PCM) was 4mm, thermal performance was effective. n-Octadecane in summer season and n-Hexadecane(18℃ PCM) in winter season are indicated effective on energy savings, respectively.

  • PDF

Development of PET Flame Retardant Sheets for Industrial Materials by Control of Manufacturing Process (제조공정제어에 의한 친환경 고성능 산업용 PET 난연시트 제조기술의 개발)

  • Kim, Hea-In;Hong, Yo-Han;Park, Soo-Min
    • Textile Coloration and Finishing
    • /
    • v.21 no.4
    • /
    • pp.46-56
    • /
    • 2009
  • In order to establish the standard manufacturing condition of PET flame retardant sheets, physicochetnical properties of the samples made by the conventional flame-retardant finishing were systematically investigated, including compatibility among flame retardant agent and finishing auxiliaries, surface property, and wicking property. From this results, the addition of washing and renapping process after the shearing process was required for the more effective in producing PET flame-retardant sheet by the standard finishing. The effect of the modification of the regular flame retardant finishing process was studied by FTIR, TGA, and flame retardancy test.

An Evaluation on Adhesive Weight of Incoming Salt by Paint used for Finishing Material of Steel (강재의 마감재로 사용된 도료별 비래염분 부착량 평가)

  • Cho, Gyu-Hwan;Lee, Young-Jun;Kim, Woo-Jae;Park, Dong-Cheon
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.11a
    • /
    • pp.177-178
    • /
    • 2013
  • Steel structures of the seaside area are naturally led to surface corrosion due to incoming salt. Signature measures for this are to replace steel with steel material with a high corrosion-resistance and to block salt and other deteriorative factors beforehand through finishing work such as surface coating. However, the variety in steel materials, finishing type, and construction methods makes adhesive weight of incoming salt different depending on each type. For this research, measurement results derived from an enhancement experiment on artificial incoming salt adhesive to 4 steel finishing types and 2 material types identified a difference of adhesive weight by each sampler.

  • PDF

A Study of Application Characteristic Evaluation Research of Flexible FRP Resin on the Roof and Floor of Parking Area (연질 FRP수지의 옥상주차장바닥 적용성 평가 연구)

  • Lee, Hyung-Jun;Kim, Sung-Sik;Ahn, Sang-Ku;Cho, Ah-Hyung;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2007.11a
    • /
    • pp.129-132
    • /
    • 2007
  • From this research the construction civil official is simple with the parking floor finishing material, it improves the durability of the parking floor it uses the flexible FRP it will be able to secure the drainage quality it is excellent and it presents the efficient application plan from the construction site. The performance appraisal only efficiency with of result floor of parking area material bay it knows, the result where also the performance appraisal portion re-with roof bottom finishing is satisfied it showed. The flexible FRP it applies the material to the building as to diminish the damage of the bottom finishing material due to the deterioration and the conduct and the external force of the building it is exposed to the external environment, secures the quality of the material from the construction site and will contribute to the stability against the bottom finishing material.

  • PDF

A Study on Development and Construction Methods of the Inorganic Floor Finishing Material of Hazardous Material Storage Facilities (위험물 저장시설의 무기질 바닥마감재와 이를 이용한 시공방법에 관한 연구)

  • Oh, Dong-Seok;Yu, Chul-Hee;Kim, Byung-Duk;Kim, Heum;Park, Sang-Min
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.4
    • /
    • pp.35-43
    • /
    • 2014
  • Usage of the inorganic floor finishing material can be advantageous to overcome some problems of traditional organic-based floor finishing material used for hazardous material storage facilities. A spark can be produced by physical impact between the flooring and the flooring disposal equipment while removing the existing flooring. In order to prevent a fire hazard, which may be caused the spark, it is feasible that a construction can be implemented without removing the existing flooring. Moreover, the top coating material containing an antistatic agent is effective to prevent secondary damage caused by static electricity after finishing the construction of the flooring. Therefore, the inorganic floor finishing material of the this study is expected to be beneficial for safety management and economical aspect for inspectors.