• Title/Summary/Keyword: fineness of cement

Search Result 151, Processing Time 0.021 seconds

Quick evaluation for cement powder of synthesize with the hydrometer density value and change temperature (Hydrometer의 밀도 값과 혼탁액 온도를 복합한 포틀랜드 시멘트의 분말도 신속 평가)

  • Lee, Jae-Jin;Han, Jun-Hui;Hyun, Seong-Yong;Kim, Yeong-Tae;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.87-88
    • /
    • 2018
  • The change in the degree of powder in cement is very important because it plays a major role in the reaction in the concrete. In this study, we intend to apply the principle of early estimation of concrete strength using the non-middling method previously conducted to the quality evaluation of cement powder. In other words, it is proposed to analyze the potential of Hydrometer density values and the data of temperature variation in the trust solution to propose a method of acceptance inspection. According to the experimental results, the quick evaluation of the cement distributorship will be possible if the resulting regression results are used : y = 161867.4 x1 + 117.953 x2 - 165437 (R = 0.9158).

  • PDF

A Study on the Mix Design and Quality Factors of the Combined High Flowing Concrete Using High Belite Cement

  • Kwon, Yeong-Ho
    • KCI Concrete Journal
    • /
    • v.14 no.3
    • /
    • pp.121-129
    • /
    • 2002
  • This study investigates experimentally into the design factors and quality variations having an effect on the properties of the combined high flowing concrete to be poured in the slurry wall of Inchon LNG in-ground receiving terminal. Especially, high belite cement and lime stone powder as cementitious materials and viscosity agent in order to improve self-compaction and hydration heat are used in this study. Water-cement ratio(W/C), fine aggregate volume ratio(Sr) and coarse aggregate volume ratio(Gv) as design factors of the combined high flowing concrete are applied to determine the optimum mix design proportion. Also quality variations for sensitivity test are selected items as followings. (1)Surface moisture(5cases) and (2)Fineness modulus of fine aggregate(5cases), (3)Concrete temperature(3cases), (4)Specific surface(3cases) and particle size of lime stone powder. As experimental results, water-cement ratio, fine and coarse aggregate volume ratio are shown as the optimum range 51%, 43% and 53% separately considering site condition of slurry wall. Also quality factors by sensitivity test should be controlled in the following ranges. (1) Surface moisture :to.67% and (2)Fineness modulus 2.6$\pm$0.2 of fine aggregate, (3)Concrete temperature l0-20t, (4) Specific surface 6,000$\textrm{cm}^2$/g and particle size 9.7$\pm$1.0${\mu}{\textrm}{m}$ of lime stone powder. Based on the results of this study, the optimum mix design proportion of the combined high flowing concrete are selected and poured successfully in the slurry wall of LNG in-ground tank.

  • PDF

Rheology Properties of Ultrafine Blast Furnace Slag Replacement Cement Paste on Gypsum Volume Fraction (석고 혼입율에 따른 초미분 고로슬래그 치환 시멘트 페이스트의 유동특성)

  • Lee, Gun-Young;Lee, Gun-Cheol;Choi, Jung-Gu;Kim, Woo-Jae
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.11a
    • /
    • pp.178-179
    • /
    • 2014
  • The fine blast furnace slag is widely used as the admixture as it helps to increase the fluidity, long term strength of the concrete but decrease the heat of hydration. In case of the fine blast furnace slag, if the fineness of the slag is enhanced with the addition of gypsum to the concrete for the supplement of low strength in early stage and the facilitation of the initial hydration, the quality of the concrete is expected to change depending on the volume of the gypsum volume fraction. But, up to now the study on the fine blast furnace slag has only focused on the effect of fineness, replacement and admixture and there have been almost no studies on the effect of the gypsum volume fraction. Accordingly, this study focuses on what effect the gypsum volume fraction would make on the fluidity characteristics of the ultrafine furnace slag cement paste by using the rheology properties.

  • PDF

An Experimental Study for Crack Prevention of Floor Mortar (바닥용 모르타르의 균열방지를 위한 실험적 연구)

  • 정재동;최응규;김진근;이칠성;이상순
    • Magazine of the Korea Concrete Institute
    • /
    • v.8 no.3
    • /
    • pp.167-175
    • /
    • 1996
  • Recently, the mortar crack on floor is very serious in construction field, e.g. the crack due to plastic shrinkage and the crack due to drying shrinkage. To prevent this kind of crack, optimum mix proportions not only satisfying the required workability but also minimizing the unit water content were selected. And the expansion admixtures were used to compensate shrmkage of mortar. The water /cement ratio used in construction field is about 64% by the investigation. Even if the water /cement ratio of mortar is reduced, floor mortar is still able to have the required workability by the appropriate use of the fine aggregate with high fineness mo'dulus and superplastizer. The equations hetween mortar flow and water /cement ratio, sand /cement ratio, fineness modulus of fine aggregate were proposed in this study. And the proposed equation may provide available mix proportions of floor mortar.

An Experimental Study on the Influence of High Fineness Fly Ash and Water-Binder Ratio on Properties of Concrete (콘크리트 특성에 미치는 고분말도 플라이애쉬의 치환율 및 물-결합재비 영향에 관한 실험적 연구)

  • Lee, Sang-Soo;Song, Ha-Young;Lee, Seung-Min
    • Journal of the Korea Concrete Institute
    • /
    • v.21 no.1
    • /
    • pp.29-35
    • /
    • 2009
  • Recently, the press and institute recognized fly ash as it had excellent performance. Its research and applications are on the rise largely as a substitute for cement. On the contrary, it is in a situation that the regulation of high fineness fly ash remains at a low level. As for the fly ash in $3,000{\sim}4,500\;cm^2/g$ class fineness regulated in KS L 5405, it is used by substituting it around the unit weight of cement 20%. Accordingly, the regulation in upper classification is in a situation of being insufficient. Therefore, this study aimed to establish 4000, 6000, and 8000 class of fineness of fly ash and three levels of substitute like 15%, 30%, and 45% in order to analyze the substitute and effect of water-binder ratio for fly ash that affected the properties of ternary system concrete. As a result of experiment by planning water-binder ratio for two levels like 40% and 50%, the more replacement ratio and fineness of fly ash increased in the performance not hardened, the more the fluidity increased. This study has found out that the air content decreased, and that there was setting acceleration and it decreased the heat of hydration. In addition, as for the strength properties in a state of performance hardened concrete, the more the replacement ratio and the ratio of water-binding materials increased, the more it had a tendency of being decreased.

A Study on Sound Absorption Properties of Foamed Concrete with Continuous Voids (연속공극을 갖는 기포콘크리트의 흡음특성에 관한 연구)

  • 이승한;박정준;황보광수
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10a
    • /
    • pp.567-570
    • /
    • 2000
  • This study is designed to manufacture the continuous foamed concrete and the sound absorption characteristics investigation due to continuous voids ratio. According to the results of experiment, it was shown that continuous voids of the foamed concrete has the influence of the amount used of foaming agent, the viscosity and flowability of cement paste, and also is shaped by cohesive power of bubbles. Also the sound absorption ratio of the foamed concrete is subject to increase as the density becomes low by raising the continuous voids ratio. The cement paste with low water-cement ratio and high cement fineness are very effective to prevent weak strength of formed concrete caused by the increase of the porosity.

  • PDF

Property of Strength Development on the Concrete with Coarse Particle Cement (굵은 입자 시멘트를 사용한 콘크리트의 강도발현 특성)

  • Noh, Sang-Kyun;Son, Ho-Jung;Baek, Dae-Hyun;Chung, Woung-Sun;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.05a
    • /
    • pp.89-91
    • /
    • 2011
  • This paper is to investigate experimentally the property of strength development on the concrete for 5 years according to the change of a replacement rate of coarse particle cement in order to use coarse particle cement with a fineness of 1 900 ㎠/g that is classified during a grinding process of the OPC production. The result is that as the CC replacement rate increased, the compressive strength was decreased proportionally. but the width of strength reduction was reduced as time passed.

  • PDF

Physical Properties of ALC with Various Fineness of Quartzite (규석 분말도에 따른 ALC의 물리적 특성 변화)

  • Chu, Yong-Sik;Jung, Ui-Jong;Song, Hun;Lee, Jong-Kyu;Kim, Young-Gon;Kang, Dae-Gu
    • Journal of the Korean Ceramic Society
    • /
    • v.47 no.5
    • /
    • pp.407-411
    • /
    • 2010
  • ALC was fabricated using cement, lime and quartzite by hydrothermal reaction. ALC has low strength and brittleness on account of inner pores. The studies for resolving these problems were driven by many researchers. Among these researches, the controls of quartzite fineness have been studied for unsuitable properties of ALC. This study experimented with variation of 90 ${\mu}m$ residue for obtain good physical properties. It was found that 90 ${\mu}m$ residue influenced on physical properties of ALC. The lower amount of 90 ${\mu}m$ residue, the higher compressive and bending strength. But the continuing decrease of 90 ${\mu}m$ residue did not cause the increase of strength. In order to application of these results in process, the states of process and hydrothermal products will be considered.

An Experimental Study on the Influence of the Qualities of Ordinary Portland Cement on the Flowability of High Flow Concrete (보통 포틀랜드 시멘트 품질이 고유동 콘크리트의 유동 특성에 미치는 영향에 관한 연구)

  • Choi, Sung-Woo;Jo, Hyun-Tae;Ryu, Deug-Hyun;Kim, Gyu-Yong
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.1
    • /
    • pp.37-44
    • /
    • 2012
  • Recently, due to developments in construction technology, the use of high-performance concrete became popular. High-performance concrete when compared to the ordinary concrete can better satisfy required performances by using mineral admixture and superplasticizer. Various studies on the effect of admixture materials on the quality of high-performance concrete have been reported. But there exist limited number of reported results on the effect of cement qualities, which is the most important constituent material in concrete. Therefore, in this study, the relationship between the quality of cement and the flowability of high flowing concrete is investigated. Qualities of domestically produced cement were identified, and then the influence of the qualities of cement on the flowability of high flowing concrete is evaluated. The result showed that the dosage of required superplasticizer was dependent on cement fineness, to brain, free-CaO, and interstitial phase, which all trigger initial hydration process of cement. Particularly, the results showed that fineness of cement has a high impact on the dosage of the superplasticizer. For strength property of concrete, the dosage of superplasticizer had a significant effect on the early age strength, but had negligible effect in the long term strength.

Physical Properties of Cement System Insulation Using Blast Furnace Slag

  • Seo, Sung Kwan;Park, Jae Wan;Cho, Hyeong Kyu;Chu, Yong Sik
    • Journal of the Korean Ceramic Society
    • /
    • v.55 no.1
    • /
    • pp.61-66
    • /
    • 2018
  • In this study, fabrication method of inorganic insulation were studied to reduce $CO_2$ from buildings. Main materials for inorganic insulation were used cement, blast furnace slag and aluminum powder as foaming agent. Mixing ratio of cement and slag was controlled and physical properties of inorganic insulation were analyzed. When inorganic insulation was fabricated using cement and slag, expanded slurries were not sunken and hardened normally. Pore size was 0.5 - 2 mm; mean pore size was about 1mm in inorganic insulation. Compressive strength of inorganic insulation increased with curing time and increased slightly with cement fineness. However, specific gravity decreased slightly with curing time; this phenomenon was caused by evaporation of adsorptive water. When inorganic insulation was dried at $60^{\circ}C$, compressive strength was higher than that of undried insulation. The highest compressive strength was found with a mixture of cement (50%) and slag (30%) in inorganic insulation. Compressive strength was 0.32 MPa, thermal conductivity was 0.043 W/mK and specific gravity was $0.12g/cm^3$.