• Title/Summary/Keyword: fault current characteristics

Search Result 607, Processing Time 0.033 seconds

External and Internal Morphological Standard of Original Plants and Herbal States in Pogostemonis and Agastachis Herba (廣藿香과 土藿香의 外部 및 內部形態硏究)

  • Kang, Jun-hyug;Choi, Jeong;Ju, Young-sung
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.16 no.3
    • /
    • pp.164-184
    • /
    • 2003
  • Objectives : This study was designed to establish a characteristic discrimination of internal and external morphological standard of original plants and herbal states in Pogostemonis and Agastachis Herba. Methods : In this studies, the external-internal morphological standards were determined by using stereoscope and butanol series. Results : 1. The external characteristics: Pogostemon cablin has hairs and brown-like in stem, elliptical fruit. On the other hand, Agastache rugosa has no hairs and red-like in stem, obovatic trigone fruit. 2. The physical characteristics: Pogostemon cablin is gray in whole, has hairs in stem and numerous hairs of ash in leaf. On the other hand, Agastache rugosa is yellow-green in whole, has no hairs in stem. Specially the latter has deep-green colour and numerous hairs presenting mostly at lower epidermis in leaf. 3. The physical characteristics in currents: Pogostemon cablin is brown, has hairs and round-like stem. On the other hand, Agastache rugosa is green or yellow-green, has no hairs and tetragon in stem. 4. The internal characteristics: Pogostemon cablin has progressed spongy tissue in epidermal cell of leaf and many rank of epidermal cell in stem. On other hand, Agastache rugosa has I rank palisade tissue in leaf and few rank of epidermal cell in stem. In the external shape, it was possible that herbs were distinguished according to artificial cIassification and that same genus-degree of relatedness among herbs could be distinguished by more precise and active observation. In the shape of real herbs, I compared current herbs in market with original herbs which were just collected or were on the course of drying. In addition, it was possible that the internal shape could be identified by using microscope after butanol series. Conclusion : Though it was impossible to make distinction of herbs which are not current in my search contents, this search contents will be a standard for applying herbs in the future. An Additional standard establishment including physiochemical reaction and gene research is required in order to supplement the fault of this search.

  • PDF

Neotectonic Crustal Deformation and Current Stress Field in the Korean Peninsula and Their Tectonic Implications: A Review (한반도 신기 지각변형과 현생 응력장 그리고 지구조적 의미: 논평)

  • Kim, Min-Cheol;Jung, Soohwan;Yoon, Sangwon;Jeong, Rae-Yoon;Song, Cheol Woo;Son, Moon
    • The Journal of the Petrological Society of Korea
    • /
    • v.25 no.3
    • /
    • pp.169-193
    • /
    • 2016
  • In order to characterize the Neotectonic crustal deformation and current stress field in and around the Korean Peninsula and to interpret their tectonic implications, this paper synthetically analyzes the previous Quaternary fault and focal mechanism solution data and recent geotechnical in-situ stress data and examines the characteristics of crustal deformations and tectonic settings in and around East Asia after the Miocene. Most of the Quaternary fault outcrops in SE Korea occur along major inherited fault zones and show a NS-striking top-to-the-west thrust geometry, indicating that the faults were produced by local reactivation of appropriately oriented preexisting weaknesses under EW-trending pure compressional stress field. The focal mechanism solutions in and around the Korean Peninsula disclose that strike-slip faulting containing some reverse-slip component and reverse-slip faulting are significantly dominant on land and in sea area, respectively. The P-axes are horizontally clustered in ENE-WSW direction, whereas the T-axes are girdle-distributed in NNW direction. The geotechnical in-situ stress data in South Korea also indicate the ENE-trending maximum horizontal stress. The current crustal deformation in the Korean Peninsula is thus characterized by crustal contraction under regional ENE-WSW or E-W compression stress field. Based on the regional stress trajectories in and around East Asia, the current stress regime is interpreted to have resulted from the cooperation of westward shallow subduction of the Pacific Plate and collision of Indian and Eurasian continents, whereas the Philippine Sea plate have not a decisive effect on the stress-regime in the Korean Peninsula due to its high-angle subduction that resulted in dominant crust extension of the back-arc region. It is also interpreted that the Neotectonic crustal deformation and present-day tectonic setting of East Asia commenced with the change of the Pacific Plate motion during 5~3.2 Ma.

Power System Security Control Method for Quench Characteristic of High-Temperature Superconducting Cable (초전도 케이블의 Quench 특성에 대한 계통안전성 제어방식)

  • Lee, Geun-Joon;Hwang, Si-Dol
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.6
    • /
    • pp.29-35
    • /
    • 2005
  • This paper presents the basic quench protection idea for the HTS(High-Temperature Superconducting) cable. In Korea power system, the transfer capability of transmission line is limited by the voltage stability, HTS cable could be one of the countermeasure to enhance the transfer limit with its higher current capacity and lower impedance[1]. However, the quench characteristic makes not only HTS cable to loss its superconductivity, but also change the impedance of the transmission line and power system operating condition dramatically. This pheonominum threats HTS cable safety as well as power system security, therefore a proper protection scheme and security control counterplan have to be established before HTS cable implementation. In this paper, the quench characteristics of HTS cable for the fault current based on heat balance equation was established and a proper protection method regarding conventional protection system was suggested.

Analysis on the Improvement of Power Capacity Increase in the Transformer-Type SFCL with Neutral Lines (중성선을 갖는 변압기형 초전도 한류기의 용량증대 개선 연구)

  • Cho, Yong-Sun;Choi, Hyo-Sang;Kim, Deog-Goo;Go, Sung-Pil
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.7
    • /
    • pp.1438-1443
    • /
    • 2011
  • The increase of power capacity in the superconducting fault current limiter (SFCL) is essential for application into the power grid. To achieve this, when superconducting units were connected in series and parallel, the unbalanced quenching characteristics between superconducting units generated by different critical current behavior should be improved. In the transformer-type SFCL, the superconducting units connected in series could be simultaneously quenched by the connection of neutral lines between secondary coils and superconducting units. From this the consumed power in superconducting units was equally distributed. In addition, the more the turn ratio of the transformer was reduced, the more consumed power in the superconducting units was reduced by the decrease of the induction voltage generated in the superconducting units. From those results, the transformer-type SFCL using neutral lines could increase the power capacity of the SFCL by the equal power division into the superconducting units.

A Study on Degradation Pattern of GIS Using Clustering Methode (군집화 기법을 이용한 GIS 열화 패턴 연구)

  • Lee, Deok Jin
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.31 no.4
    • /
    • pp.255-260
    • /
    • 2018
  • In recent years, increasing electricity use has led to considerable interest in green energy. In order to effectively supply, cut off, and operate an electric power system, many electric power facilities such as gas insulation switch (GIS), cable, and large substation facilities with higher densities are being developed to meet demand. However, because of the increased use of aging electric power facilities, safety problems are emerging. Electromagnetic wave and leakage current detection are mainly used as sensing methods to detect live-line partial discharges. Although electromagnetic sensors are excellent at providing an initial diagnosis and very reliable, it is difficult to precisely determine the fault point, while leakage current sensors require a connection to the ground line and are very vulnerable to line noise. The partial discharge characteristic in particular is accompanied by statistical irregularity, and it has been reported that proper statistical processing of data is very important. Therefore, in this paper, we present the results of analyzing ${\Phi}-q-n$ cluster distributions of partial discharge characteristics by using K-means clustering to develop an expert partial discharge diagnosis system generated in a GIS facility.

A Study on the Fault Current Characteristics for the Utility Application of HTS Power cable (초전도 전력케이블의 전력계통 적용을 위한 고장전류 특성에 관한 연구)

  • Kim, Jae-Ho;Park, Min-Won;Sim, Ki-Deok;Cho, Jeon-Wook;Yu, In-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.75-76
    • /
    • 2007
  • Several kinds of High Temperature Superconducting(HTS) power cables have already been developed and evaluated for use in the utility power network. HTS power cable is expected to be used as a very powerful energy delivery system supplying electric power for densely populated cities in the near future, because HTS power cable is capable of the high current density delivery with low AC loss and the size effect comparing with the conventional cable whose capacity is same. Before applying the HTS power cable to real utility network system analysis should be carried out by some simulation tools. Hereby the electrical power system analysis is very important for the practical use of HTS power devices. In this paper, authors propose a real-time simulation method which incorporates a real HTS tapes into the simulated 22.9kV utility power network system using Real Time Digital Simulator(RTDS). For the simulation analysis, a test sample of HTS tapes was actually manufactured, and the transient phenomenon of HTS power cable system was analyzed in the simulated utility power network.

  • PDF

Current Limiting Characteristics due to Location of Superconducting Fault Current Limiter in Power Distribution System (모의 배전계통에 초전도한류기 도입위치에 따른 전류제한 특성)

  • You, Il-Kyoung;Kim, Jin-Seok;Kim, Myoung-Hoo;Lim, Sung-Hun;Moon, Jong-Fil;Kim, Jae-Chul
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.97-100
    • /
    • 2009
  • 배전계통에서 전력수요의 증가와 분산전원의 증가로 대용량 변압기의 적용이 불가피하게 되었다. 하지만, 대용량 변압기로 교체할 경우 배전계통에 고장발생시 고장전류의 크기가 증가되어 기존에 설치된 차단기 및 보호기기의 차단용량 초과로 인해 교체에 따른 경제적 비용 상승이 우려된다. 따라서, 대용량 변압기의 교체시 고장전류 증가 문제를 해결하기 위한 방안 중 하나로 초전도한류기를 설치하는 방안을 검토하고 있다. 초전도 한류기는 평상시에 초전도 상태인 영 저항이므로 전력손실이 발생하지 않으며, 고장 발생시 치로 인한 신속한 저항 발생으로 고장전류를 빠르게 감지 및 제한함으로써 기존에 설치된 차단기의 차단 용량이하로 감소시켜 줄뿐만 아니라 계통의 안정도를 향상시킬 수 있다. 그러나, 초전도한류기는 도입위치에 따라 ��치 발생시 초전도한류기의 저항 크기가 다르게 되며, 고장전류 제한효과 및 보호협조를 고려한 적정의 한류기 저항 설정이 필요하다. 이에 대한 선행연구로서, 본 논문에서는 모의 배전계통에 초전도한류기를 적용하였을 경우 도입위치에 따라 전류제한, 모선 전압강하, 초전도한류기의 전력부담을 실험을 통하여 비교 분석하였다. 분석을 통해 초전도한류기를 피더에 설치하였을 경우 전류제한 효과, 모선 전압강하 보상효과는 가장 우수하였으나 가장 많은 전력부담을 갖는 것을 확인할 수 있었다.

  • PDF

Analysis of short current limiting characteristics of a flux-lock type superconducting fault current limiter(SFCL) depending upon design parameters (설계 파라미터에 따른 자속구속형 사고전류제한기의 단락전류 제한 특성 분석)

  • SeoMoon, Hyun;Bak, Jae-Wan;Oh, Su-Jin;Choi, Jun-Yeong;Lee, Geol-Yeol;Lim, Sung-Hun
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.2004-2005
    • /
    • 2007
  • 고온 초전도체를 이용한 자속구속형 사고전류제한기는 1차권선과 2차권선을 감는 방향이나 감은 횟수의 비율에 따라서 부하전류용량과 전류제한용량이 다르다. 부하전류용량은 사고 발생 시 최초의 전류 제한 레벨과 밀접하게 관련이 되는데 자속구속형 사고전류제한기에서 최초의 전류 제한 레벨은 인덕턴스에 의해서 결정되기 때문이다. 전류제한용량은 사고전류제한기의 임피던스와 관계된다. 이 논문에서 자속구속형 사고전류제한기의 변압기 특성을 변화시키면서 부하전류용량과 전류제한용량의 변화를 살펴보았다.

  • PDF

Stochastic Method to Assess Voltage Sag Performance Considering Sag Duration in Large Power System (대규모 계통에서의 순간전압강하 지속시간을 고려한 추계적 평가 방법)

  • Lee, Myeong-Cheol;Park, Chang-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.30 no.2
    • /
    • pp.85-92
    • /
    • 2016
  • The paper presents a method to assess system voltage sag performance considering sag durations as well as magnitudes. In general, voltage sag assessment for large power systems is performed only considering sag magnitudes at sensitive load points. However some equipment can be affected by certain sag durations. The duration of the voltage sag is depend on the time of fault current flow in the system. Therefore, the duration can be determined by analyzing the operating characteristic of the protection system. In this paper, an effective method to evaluate sag durations regarding the characteristics and failure rates of the protection system is described. The proposed method can be used to assess the long-term performance of the voltage sags in large power system.

Characteristics of Sub-cooled Nitrogen Cryogenic System for Applied High-Tc Superconducting Devices (고온초전도 응용기기용 과냉질소 냉각시스템의 냉각특성)

  • 강형구;김형진;배덕권;안민철;윤용수;장호명;고태국
    • Progress in Superconductivity and Cryogenics
    • /
    • v.6 no.1
    • /
    • pp.38-42
    • /
    • 2004
  • The cryogenic system for 6.6 kV/200 A inductive superconducting fault current limiter (SFCL) was developed at Yonsei university in 2003. The sub-cooled nitrogen cryogenic system could be applied to not only SFCL but also many other applied high-Tc superconducting (HTS) devices like superconducting motor, superconducting generator and superconducting magnetic energy storage (SMES). Generally, the cooling capacity of GM-cryocooler depends on the load temperature. Therefore it is necessary to perform the cooling capacity test at no load condition to calculate the exact cooling power and heat load of cryogenic system. In this research, the cooling capacity test of GM-cryocooler was executed and the heat load of developed cryogenic system was calculated. The long run operation test results of sub-cooled nitrogen cryogenic system were successful in pressure and temperature condition. Moreover, the design and fabrication method of cryogenic system were introduced and the test results were described.