• Title/Summary/Keyword: failure line

Search Result 839, Processing Time 0.025 seconds

Bond-slip Effect of Reinforced Concrete Building Structure under Seismic Load using Finite Element Analysis (유한요소해석을 활용한 지진하중에 대한 철근콘크리트 건축물의 부착성능 효과 연구)

  • Kim, Yeeun;Kim, Hyewon;Shin, Jiuk
    • Journal of Korean Association for Spatial Structures
    • /
    • v.22 no.4
    • /
    • pp.99-107
    • /
    • 2022
  • Existing reinforced concrete building structures constructed before 1988 have seismically-deficient reinforcing details, which can lead to the premature failure of the columns and beam-column joints. The premature failure was resulted from the inadequate bonding performance between the reinforcing bars and surrounding concrete on the main structural elements. This paper aims to quantify the bond-slip effect on the dynamic responses of reinforced concrete frame models using finite element analyses. The bond-slip behavior was modeled using an one-dimensional slide line model in LS-DYNA. The bond-slip models were varied with the bonding conditions and failure modes, and implemented to the well-validated finite element models. The dynamic responses of the frame models with the several bonding conditions were compared to the validated models reproducing the actual behavior. It verifies that the bond-slip effects significantly affected the dynamic responses of the reinforced concrete building structures.

Failure analysis of a transmission tower during a microburst

  • Shehata, A.Y.;El Damatty, A.A.
    • Wind and Structures
    • /
    • v.11 no.3
    • /
    • pp.193-208
    • /
    • 2008
  • This paper focuses on assessing the failure of one of the transmission towers that collapsed in Winnipeg, Canada, as a result of a microburst event. The study is conducted using a fluid-structure numerical model that was developed in-house. A major challenge in microburst-related problems is that the forces acting on a structure vary with the microburst parameters including the descending jet velocity, the diameter of the event and the relative location between the structure and the jet. The numerical model, which combines wind field data for microbursts together with a non-linear finite element formulation, is capable of predicting the progressive failure of a tower that initiates after one of its member reaches its capacity. The model is employed first to determine the microburst parameters that are likely to initiate failure of a number of critical members of the tower. Progressive failure analysis of the tower is then conducted by applying the loads associated with those critical configurations. The analysis predicts a collapse of the conductors cross-arm under a microburst reference velocity that is almost equal to the corresponding value for normal wind load that was used in the design of the structure. A similarity between the predicted modes of failure and the post event field observations was shown.

D.C. Power system Failure Point Informing Device Development of Face Trial for the Site Installation (직류급전시스템 고장점표정장치 개발을 위한 현장시범 설치)

  • Kim, Youn-Sik;Kim, Yong-Duk;Ha, Tae-Yoo;Han, Moon-Seob;Park, Jong-Gook;Im, Hyeong-Gil
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.2011-2014
    • /
    • 2011
  • A "failure point informing device" is that if a accident of short or ground occurs in electric railway it inform us of the distance to accident point. SeoulMetro, KRRI, 2ISYS have developed this device and installed in line no.4 substation Iy-Chon, Sam-Gakgi to test its performance. A line resistance will be measured to test this device in November.

  • PDF

Ground Behavior and Reinforcing Methods of NATM Tunnel through Deep Weathered Zone (NATM 터널의 대심도 풍화대층에서의 지반거동 및 보강방법)

  • Sung, Hwa-Don;An, Jung-Whan;Chun, Byung-Sik
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.1782-1788
    • /
    • 2007
  • This study analyzed ground settlement and ground stress depending on tunnel excavation and the ground reinforcing grouting methods for double line road tunnel through deep weathered zone. Diameter of double line road tunnel was approximately 12m and umbrella arch method and side wall reinforcing grouting were applied. The ring-cut split excavation method and CD-cut excavation method for excavation method were applied. Analysis of failure rate and vertical stress ratio show that the tunnel for which the height of the cover(H) was higher than four times the diameter, it can be considered a deep tunnel. Comparisons of various excavation and ground reinforcement methods were showed that CD-cut method results in lower surface and crown settlement, and lower failure rate than where using Ring-cut split method. In addition the side wall reinforcing grouting resulted in reduction of tunnel displacement and settlement.

  • PDF

Effects of Anisotropic Consolidation on Flow Failure Behavior of a Silty Sand (이방압밀이 실트질 모래의 유동파괴거동에 미치는 영향)

  • 강병희;김방식;정혁일
    • Journal of the Korean Geotechnical Society
    • /
    • v.17 no.5
    • /
    • pp.173-180
    • /
    • 2001
  • 이방압밀이 실트질모래의 정적재하에 의한 유동파괴거동에 미치는 영향을 연구하기 위하여 비배수삼축압축시험을 수행하였다. 이를 위하여 상대밀도가 약 17%인 공시체를 습윤다짐방법에 의해서 성형하고 4가지의 압밀응력비, 1.0, 0.7, 0.55, $K_{o}$ 로서 압밀시켰다. 시험결과로서 정상상태선은 p-q 공간상에서 압밀응력비에 관계없이 유일한 직선이며 collapse line의 기울기는 압밀응력비가 증가함에 따라 선형적으로 감소한다는 사실을 보여준다. 또한, 유동파괴거동을 보이는 느슨하게 다져진 실트질모래의 잔류강도($S_{us}$ )와 첨두강도($S^{p}$ )와의 관계는 압밀응력비의 크기에 관계없이 $S_{p}$ /$p_{c}$ = $A_{L}$ +$B_{L}$ ($S_{us}$ /$p_{c}$ )로 표현되는 일반식으로 나타낼 수 있으며 계수 $A_{L}$$B_{L}$은 압밀응력비의 크기에 따라 선형적으로 변하는 경향을 나타낸다.

  • PDF

Development of On-Line Diagnostic Expert System : Heuristics and Influence Diagrams (현장진단 전문가 시스템의 개발 : 휴리스틱과 인플루언스 다이아그램)

  • Kim, Young-Jin
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.23 no.1
    • /
    • pp.95-113
    • /
    • 1997
  • This paper outlines a framework for a diagnosis of a complex system with uncertain information. Sensor validation ploys a vital role in the ability of the overall system to correctly determine the state of a system monitored by imperfect sensors. Here, emphases are put on the heuristic technology and post-processor for reasoning. Heuristic Sensor Validation (HSV) exploits deeper knowledge about parameter interaction within the plant to cull sensor faults from the data stream. Finally the modified probability distributions and validated data are used as input to the reasoning scheme which is the runtime version of the influence diagram. The output of the influence diagram is a diagnostic mapping from the symptoms or sensor readings to a determination of likely failure modes. Once likely failure modes are identified, a detailed diagnostic knowledge base suggests corrective actions to improve performance. This framework for a diagnostic expert system with sensor validation and reasoning under uncertainty applies in $HEATXPRT^{TM}$ a data-driven on-line expert system for diagnosing heat rate degradation problems in fossil power plants [1].

  • PDF

A Protection Method with single-bonding system in EHV Underground Transmission Line (초고압 지중 케이블 시스템에 대한 편단접지시의 보호대책)

  • Kim, J.W.;Kang, D.H.;Park, K.R.;Kim, Y.B.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1620-1622
    • /
    • 1998
  • The failure occurs in the system of the underground transmission line, the time of restoration is very long, the damage from stopping power supply is very serious and the cost of restoration is very great. because of these problems, the system and equipment must be protected from every electrical failure by installing protection unit. This study is summarized and compared the effects of configuration method of cable protection device with respect to surges in EHV (Extra High Voltage) underground transmission system.

  • PDF

A Study on Design of Production System Using Multiple Characteristics Robust Design in Uncertain Environment (불확실한 환경에서의 다특성치 강건설계를 이용한 생산시스템 설계에 관한 연구)

  • 양광모;서장훈;박진홍;강경식
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2004.05a
    • /
    • pp.61-65
    • /
    • 2004
  • As technique that can contribute in quality improvement in design process to overcome shortcoming of traditional quality control, call design or development department quality control activity that is achieved to reduce gun damage shuddering at circle minimizing change or side effect of product performance as off-line quality control. This paper discuss optimal process design of investment projects expansion and replacement investment on each line or individual in the production. Generally optimal plant design has add to a few method by Subsidiary means with use a especial method. And then in this paper, a Robust design is presented, which may be effective to the processes appraisal or improvement. We propose that should make a optimal plant design model for reducing field failure rate to assign by real data on different factors in plant system. Using this model, robust design of taguchi method used in this comprehensive method for reducing field failure rate in plant system.

  • PDF

Fault Tolerant Straight-Line Gaits of a Quadruped Robot with Feet of Flat Shape (평판 발을 가지는 사족 보행 로봇의 내고장성 걸음새)

  • Yang, Jung-Min;Kwak, Seong-Woo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.18 no.2
    • /
    • pp.141-148
    • /
    • 2012
  • This paper proposes fault tolerant gaits of a quadruped robot with feet of flat shape. Fault tolerant gaits make it possible for a legged robot to continue static walking against a leg failure. In the previous researches, it was assumed that a legged robot had feet that have point contact with the surface. When the robot is endowed with feet having flat shape, fault tolerant gaits can show better performance compared with the former gaits, especially in terms of the stride length and gait stability. In this paper, fault tolerant gaits of a quadruped robot against a locked joint failure are addressed in straight-line motion and crab walking, respectively.

A Scan-Based On-Line Aging Monitoring Scheme

  • Yi, Hyunbean;Yoneda, Tomokazu;Inoue, Michiko
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.14 no.1
    • /
    • pp.124-130
    • /
    • 2014
  • In highly reliable and durable systems, failures due to aging might result in catastrophes. Aging monitoring techniques to prevent catastrophes by predicting such a failure are required. This paper presents a scan-based on-line aging monitoring scheme which monitors aging during normal operation and gives an alarm if aging is detected so that the system users take action before a failure occurs. We illustrate our modified scan chain architecture and aging monitoring control method. Experimental results show our simulation results to verify the functions of the proposed scheme.