• Title/Summary/Keyword: facilities planning

Search Result 2,106, Processing Time 0.023 seconds

Development of Temporary Facility Planning System for High-rise Building Constructions through the Analysis of Influence Factors (영향요소 분석에 의한 고층건축공사의 가설계획시스템 개발)

  • Jang Myung-Houn
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • autumn
    • /
    • pp.164-173
    • /
    • 2002
  • The high-rise building construction field in the urban area is short of working space because it is surrounded by adjacent buildings and nearby roads. The insufficient space causes problems of interference and conflicts in transporting materials and working at the site. These problems can be resolved partly through the proper selection and layout of temporary facilities. A method proposed in this paper supports a decision-maker to evaluate and select the alternatives of temporary facilities plans by establishing and analyzing processes and influence factors of them. Knowledges considered in planning temporary facilities layout are structurized and a program is implemented for a field manager. Case studies are performed to evaluate the feasibility and applicability of the proposed method.

  • PDF

A Study on the Architectural Planning of traditional herbal medicine distribution supporting facilities (한약재유통지원시설의 건축계획에 관한 연구)

  • Bae, Joa-Sup;Oh, Jong-Hee;Kang, Won-Pil
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.14 no.2
    • /
    • pp.53-64
    • /
    • 2008
  • This study is the architectural planning of 5 distribution supporting facilities for traditional herbal medicine cultivated in the rural areas. The main function of the facility consists of storage, pre-treatment/processing, loading/unloading and the assistant function consists of inspection, office, exhibition/sale, technical equipment etc. The planning shows the modular plan and the section plan of the storage space reflecting the shape and size of storage container, the action radius of carrier and the possibilities of space lease. The total floor area of the storage is 3,192$m^2$ consisting of 27 space. The total floor area of the pre-treatment/processing is 1,488$m^2$ consisting of 7 space. The total floor area of the loading/unloading is 329$m^2$ consisting of 4 space. The total floor area of each facility storage is 8,284$m^2$ including of public space 2,170$m^2$. Also this planning shows the preliminary design, "fundamental model design" for 5 rural government BTL project. Therefore, this result of planning will be the guidelines of the RFP(Request For Proposal) for the private sector company interested in this BTL project.

  • PDF

Determining the Location of Urban Planning Measures for Preventing Debris-Flow Risks: Based on the MCDM Method (MCDM 기법을 이용한 도심지 토사재해 예방을 위한 도시계획적 대책 위치 결정방법 제안)

  • Moon, Yonghee;Lee, Sangeun;Kim, Soyoon;Kim, Myoungsoo
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.5
    • /
    • pp.103-114
    • /
    • 2017
  • The landslide disaster damage has been increased by mountain development, leading to construction of educational facilities, medical facilities, petty industrial facilities, and large housing complexes. Therefore, effective regulation is required as an effort in urban planning solutions. For suggesting specific mitigation strategies on urban landslide, this study aims to define evaluation criteria for urban planning management of debris-flow disaster. AHP (Analytic Hierarchy Process), one of the multiple criterion decision making methods, was utilized in this study. This study makes use of 16 sub-criteria under the framework of hazard, exposure, and vulnerability, and well-planned expert survey measures their weights. The weights are also applied to evaluate each grid in urban space (min $10{\times}10m$) and classify it with red, orange, yellow, or green grade so that areas at higher risk are clearly identified. This study concludes that the suggested method is useful to support a strategies for urban planning management of debris-flow disaster, particularly in a GIS base.

Planning Guidance for Snow Control Material Storage Facilities Based on Case Studies (사례조사를 통한 제설전진기지 시설기준에 관한 연구)

  • Kim, Geun-Young;Kim, Hee-Jea;Park, U-Yeol
    • Journal of the Korea Institute of Building Construction
    • /
    • v.16 no.4
    • /
    • pp.381-388
    • /
    • 2016
  • The snow control storage facilities have the physical requirements that are an anti-icing and deicing operations. They are efficiently and quickly performed, and composed of a vehicle depot for the snow removal equipment and truck, anti-icing and deicing chemical storages, and the control utilities. This study is to investigate the planning guidance of foreign countries, and the actual conditions of the snow control chemical storage facilities for expressway, the national highway and the local road, and is to suggest the planning guidelines. As some of the authorities have no fixed structures for the snow control storage, this study analyze the 5 cases constructed lately. From the result of the case studies, the operations performed in the snow control storage facilities and drawback of the facilities are analyzed with respect to layout, size, plan, and structure, and the improvement planning guidance is also suggested.

A study on the Developmental Indicators of Urban Forest with Reference to User Recreational Satisfaction -Case study of Mt. Gum-Jung- (이용자의 레크리에이션 이용만족에 기초한 도시림의 개발지표 설정에 관한 연구 -부산시 금정산을 사례로-)

  • 박승범;김승환;남정칠;강영조;양위주
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.23 no.4
    • /
    • pp.50-60
    • /
    • 1996
  • The purpose of this study is to investigate the prime factors that affect user satisfaction of area and facilities in urban forests, to classify those factors, to find out factorial structure of user satisfaction about them, and then to suggest important indicators in the urban forest planning, design, and development. The survey research was done using the self-administered questionnaire method by the people in the city of the Pusan who participated in recreational activities in the Mt. Keumjung. Factor analysis was used to extract the prime factors related to the recreational satisfaction concerning the area and facilities of the urban forest by the SPSS program, and then prime factors were used to investigate the factorial structure of user recreational satisfaction in the urban forest by the LInear Structure RELation program. According to the factor analysis concerning the 13 variables, 4 prime factors by the statistical values were considered as effective, indicating, 'health and recreational facilities', 'convenience and management facilities','facilities for the physical and psychological training' and 'historical and cultural areas'. The results of the causal structure analysis were identified as having significant effects mutually on endogenous variables, 'overall recreational satisfaction of the areas and facilities in the Mt. Keumjung','health and recreational facilities','convenience and management facilities','facilities for the psychological training', and 'historical and cultural areas'. But exogenous variables which have significant effects on endogenous variables were also indentified. Overall fits of both causal model were very good. The hypothetical causal structural equation models based on the results found partially significant correlation between dndogenous variables and between envogenous and exogenous variables. These significant relationships indiate important factors and variables that should be considered in planning, design, and development of the urban forests. Therefore, development direction of the Mt. Keumjung has to be analyzed as significant factors concerning user recreational satisfaction in a systematic was, recognized as important variables for planning process. The plan for development and management also should reflect the natural conservation policy from the environmental conservation movement like natural conservation advertisement and environmental education.

  • PDF

A Study on the vulnerability of the agricultural infrastructure based on the product of garlic and onions - Focused on Jeolla-do and Gyeongsang-do - (마늘 및 양파 주산지 농업생산기반시설의 취약성 분석 - 전라도, 경상도를 중심으로 -)

  • Jung, hyunwoo;Paik, sinwon;Kim, hanjoong
    • Journal of Korean Society of Rural Planning
    • /
    • v.23 no.4
    • /
    • pp.143-152
    • /
    • 2017
  • In recent years, the proportion of arable land in the nation has grown from 36.2 percent in 1990 to 43.7 percent in 2013. The study first performed the vulnerability assessment of agricultural production, transportation, processing facilities, agricultural machinery leasing facilities, and water supply facilities. It was developed for the evaluation of the vulnerability of each gun of garlic and onions based on the distance from the three groups of arable bodies to the facility and the processing capacity of facilities. In view of these regional imbalances, the store, distribution and processing facilities in the main stream were found in Haenam, South Jeolla-do, and the relatively low regions of the gun were located in Goheung-gun and Hampyeong-gun. Among other regions, agricultural machinery rental facilities were high in Changnyeong-gun, Haenam, and two regions, while the water supply facilities were high in the southern area of Haenam and South Jeolla-do. The Gyeongsang-do showed relatively high levels of comparison vulnerability index compared to Jeolla-do regions. In particular, through the management plan to improve the facilities needed to improve agricultural production infrastructure, it is necessary to increase the competitiveness of agricultural productuivity through the planning of the need for additional support through the rural readjustment project.

A Study on the Analysis and Estimation of the Construction Cost by Using Deep learning in the SMART Educational Facilities - Focused on Planning and Design Stage - (딥러닝을 이용한 스마트 교육시설 공사비 분석 및 예측 - 기획·설계단계를 중심으로 -)

  • Jung, Seung-Hyun;Gwon, Oh-Bin;Son, Jae-Ho
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.25 no.6
    • /
    • pp.35-44
    • /
    • 2018
  • The purpose of this study is to predict more accurate construction costs and to support efficient decision making in the planning and design stages of smart education facilities. The higher the error in the projected cost, the more risk a project manager takes. If the manager can predict a more accurate construction cost in the early stages of a project, he/she can secure a decision period and support a more rational decision. During the planning and design stages, there is a limited amount of variables that can be selected for the estimating model. Moreover, since the number of completed smart schools is limited, there is little data. In this study, various artificial intelligence models were used to accurately predict the construction cost in the planning and design phase with limited variables and lack of performance data. A theoretical study on an artificial neural network and deep learning was carried out. As the artificial neural network has frequent problems of overfitting, it is found that there is a problem in practical application. In order to overcome the problem, this study suggests that the improved models of Deep Neural Network and Deep Belief Network are more effective in making accurate predictions. Deep Neural Network (DNN) and Deep Belief Network (DBN) models were constructed for the prediction of construction cost. Average Error Rate and Root Mean Square Error (RMSE) were calculated to compare the error and accuracy of those models. This study proposes a cost prediction model that can be used practically in the planning and design stages.

A Study on the Architectural Planning in Mixed-use Tendency for Educational Facilities - The case of a plan analysis in Educational Facilities(Korea/Japan) - (학교(學校) 시설(施設) 복합화(複合化)에 관한 건축계획적(建築計劃的) 연구(硏究) - 학교(學校)(한국, 일본(韓國, 日本))의 평면(平面) 분석(分析)을 중심(中心)으로 -)

  • Rieu, Ho-Seoup;Shin, Il-Yong
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.7 no.3
    • /
    • pp.15-22
    • /
    • 2000
  • The purpose of this study is to grasp a concept for mixed-use tendency of educational facilities, its propellant circumstance in the nation and japan, to analyze a feature of a function, a flow planing of user and the complex form which appear from an instance of the mixed-use tendentious educational facilities and is to suggest a basic matter on the architectural planning for mixed-use tendency of the regional facilities and educational facilities. The results of the study can be summarized were as follow: 1) The step of mixed-use in nation is yet the early step and a extremely feeble to compared with the japan. 2) In a case of the mixed-use tendency facility, the nation is to appear for the necessity of a region but they know of a varied facility to be mixed-use tendency in japan. 3) Much to appear monolithic form in the side of complex form. 4) To appear multi-story in the side of facility-story. 5) It is much example of separating from main entrance, the flow of interior found of dividing into not to transit or transit by the function of facility. 6) To know for being tendency of common and division by the principal of user in facility instituting E V.

  • PDF

Crime Prevention Through Environmental Design of Underground Parking in Commercial Facilities - Field survey of Underground Parking Spaces in Department stores, Large Discount Mart and Mixed Used Commercial Facilities - (상업시설 지하주차장의 CPTED계획요소에 관한 연구 - 대형마트와 백화점, 복합상업시설 지하주차장 현장조사 -)

  • Min, Young Hee;Kwon, Ju-Young;Ha, Mi-Kyoung
    • Korean Institute of Interior Design Journal
    • /
    • v.25 no.3
    • /
    • pp.129-137
    • /
    • 2016
  • Dark and desolate underground parking spaces in commercial facilities are optimal spaces for crime. First, this study reviewed 15 precedent CPTED guidelines and related literatures, and as a result extracted 45 CPTED planning criteria for underground parking facilities. Secondly by field survey, we investigated six parking spaces in commercial facilities whether they were planned properly based on 45 checklist items, in six categories of CPTED principles. In result, target facilities showed average 46.8% relevance ratio, which means less than a half of 45 items of CPTED planning factors were not applied. Guidelines suggest desirable illuminance level of more than 100 lux, however the measurement of illuminance levels in some parking spaces showed below 50 lux. Relatively department stores were keeping CPTED guidelines better than large discount mart and mixed used facilities. Definition of territory of loading dock and customer area should be clarified, clear signage and color scheme in different zones should be represented with higher level of territorial responsibilities and surveillance in mixed used facilities for further improvement.