• 제목/요약/키워드: equal power distribution

검색결과 80건 처리시간 0.035초

새로운 선로용량을 고려한 전력계통의 상정사고 선택 (Contigency Ranking Technique Using New Line Capacity)

  • 박규홍;조양행
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.95-98
    • /
    • 2000
  • This paper presents a technique for contingency ranking using line capacity calculation method and outage distribution factors (LODF) which are established by generation shift distribution factors from DC load flow solutions. By using the LODF, the line flow can be calculated a ccording to the modification of base load flow if the contingency occur. To obtain contingency ranking, maximum power tansferred to the load is obtained when load impedance $Z_r$ equal to line impedance $Z_s$. The proposed algorithm has been validated in tests on a 6-bus test system.

  • PDF

Little's 법칙의 미시적 활용 사례 (A MIrcroscopic Application of the Little's Formula)

  • 윤봉규;김남기;채경철
    • 대한산업공학회지
    • /
    • 제25권1호
    • /
    • pp.125-129
    • /
    • 1999
  • The Little's formula, $L={\lambda}W$, expresses a fundamental principle of queueing theory: Under very general conditions, the average queue length is equal to the product of the arrival rate and the average waiting time. This useful formula is now well known and frequently applied. In this paper, we demonstrate that the Little's formula has much more power than was previously realized when it is properly decomposed into what we call the microscopic Little's formula. We use the M/G/1 queue with server vacations as an example model to which we apply the microscopic Little's formula. As a result, we obtain a transform-free expression for the queue length distribution. Also, we briefly summarize some previous efforts in the literature to increase the power of the Little's formula.

  • PDF

배전계통에 있어서 열병합 분산형전원의 최적 도입계획에 관한 연구 (II) (Optimal Planning for Dispersed Generating Sources in Distribution Systems(II))

  • 심헌;노대석;최재석;차준민
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.67-69
    • /
    • 2000
  • This paper deals with a method for determining an optimal operation strategy of dispersed generating sources. For effective utilization of dispersed generating sources, it is indispensable to consider their thermal merits in addition to electric power. And then the optimal operation of these sources can be determined easily by the principle of equal incremental fuel cost. This paper presents an priority method to decide the optimal location of those sources in power systems about the whole year. The validity of the proposed algorithms are demonstrated using a model system.

  • PDF

Two Sequential Wilcoxon Tests for Scale Alternatives

  • Mishra, Prafulla-Chandra
    • Journal of the Korean Statistical Society
    • /
    • 제30권4호
    • /
    • pp.679-691
    • /
    • 2001
  • Two truncated sequential tests are developed for the two-sample scale problem based on the usual Wilcoxon rank-sum statistic for two different dispersion indices - absolute median deviations, when the medians of the two populations X and Y are equal or known and sums of squared mean deviations, when the medians are either unknown or unequal. The first test is briefly called SWAMD test and the second SWSMD test. For the SWAMD test, the percentile points for both the one-sided and two-sided alternatives, (equation omitted) have been found by Wiener approximation and their values computed for a range of values of a and N; analytical expression for the power function has been derived through Wiener process and its performance studied for various sequential designs for exponential distribution. This test has been illustrated by a numerical example. All the results of the SWAMD test, being directly applicable to the SWSMD test, are not dealt with separately Both the tests are compared and their suitable applications indicated.

  • PDF

러너베인 각도에 따른 튜블러 수차의 속도 및 압력분포 (Velocity and Pressure Distributions of Tubular-type Hydroturbine for Variable Runner Vane Angle)

  • 남상현;김유택;최영도;남청도;이영호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2839-2844
    • /
    • 2007
  • Micro hydraulic power generation of which the output is less or equal to a 100kW is attracting considerable attention. This is because of its small, simple, renewable, and abundant energy resources. By using a small hydropower generator of which main concept is based on using the different water pressure levels in pipe lines, energy which was initially wasted by use of a reducing valve at the end of the pipeline, is collected by turbine in the hydropower generator. A propeller shaped hydroturbine has been used in order to use this renewable pressure energy. In this study, in order to acquire basic design data of tubular type hydraulic turbine, output power, head, efficiency characteristics due to the flow coefficient are examined in detail. Moreover influences of pressure and velocity distributions with the variations of runner vane angle on turbine performance are investigated by using a commercial CFD code.

  • PDF

3개의 초전도 소자를 갖는 자속구속형 SFCL과 변압기형 SFCL의 특성 비교 (Comparison of Characteristics on the Flux-Lock and the Transformer Type SFCLs with Three Superconducting Units)

  • 이주형;최효상
    • 전기학회논문지P
    • /
    • 제58권1호
    • /
    • pp.79-84
    • /
    • 2009
  • In order to increase the capacity of the superconducting fault current limiter(SFCL), the current and voltage grades of the SFCL must be increased. As a method for the increase of the current and voltage grades of the SFCL, we compared the various characteristics between the flux-lock type SFCL "With three superconducting units connected in series and the transformer type SFCL using the transformer with three secondary circuits. One of three superconducting units had not quenched in the flux-lock type SFCL. Therefore, the unbalanced power burden happened because of the voltage difference generated by unbalanced quenching between the superconducting units. In the meantime, the three superconducting units were all quenched in the transformer type SFCL using the transformer, and the voltage difference generated between the superconducting units was decreased. Therefore, the difference of critical characteristics was complemented by distribution of fault current in accordance with the turn's ratio between primary and secondary windings. The unbalanced power burden of the superconducting units was reduced due to flux-share between the superconducting units in the transformer. In conclusion, the capacity increment of the SFCL using a transformer was easier due to equal distribution of voltages generated by simultaneous quench of the superconducting units. We think that the characteristics is improved more because of the decrease of saturation in the iron core if the secondary winding is increased in the SFCL using the transformer.

Dynamic analysis of offshore wind turbines

  • Zhang, Jian-Ping;Wang, Ming-Qiang;Gong, Zhen;Shi, Feng-Feng
    • Wind and Structures
    • /
    • 제31권4호
    • /
    • pp.373-380
    • /
    • 2020
  • For large-scale 5MW offshore wind turbines, the discrete equation of fluid domain and the motion equation of structural domain with geometric nonlinearity were built, the three-dimensional modeling of the blade considering fluid-structure interaction (FSI) was achieved by using Unigraphics (UG) and Geometry modules, and the numerical simulation and the analysis of the vibration characteristics for wind turbine structure under rotating effect were carried out based on ANSYS software. The results indicate that the rotating effect has an apparent effect on displacement and Von Mises stress, and the response and the distribution of displacement and Von Mises stress for the blade in direction of wingspan increase nonlinearly with the equal increase of rotational speeds. Compared with the single blade model, the blade vibration period of the whole machine model is much longer. The structural coupling effect reduces the response peak value of the blade displacement and Von Mises stress, and the increase of rotational speed enhances this coupling effect. The maximum displacement difference between two models decreases first and then increases along wingspan direction, the trend is more visible with the equal increase of rotational speed, and the boundary point with zero displacement difference moves towards the blade root. Furthermore, the Von Mises stress difference increases gradually with the increase of rotational speed and decreases nonlinearly from the blade middle to both sides. The results can provide technical reference for the safe operation and optimal design of offshore wind turbines.

A comparison of tests for homoscedasticity using simulation and empirical data

  • Anastasios Katsileros;Nikolaos Antonetsis;Paschalis Mouzaidis;Eleni Tani;Penelope J. Bebeli;Alex Karagrigoriou
    • Communications for Statistical Applications and Methods
    • /
    • 제31권1호
    • /
    • pp.1-35
    • /
    • 2024
  • The assumption of homoscedasticity is one of the most crucial assumptions for many parametric tests used in the biological sciences. The aim of this paper is to compare the empirical probability of type I error and the power of ten parametric and two non-parametric tests for homoscedasticity with simulations under different types of distributions, number of groups, number of samples per group, variance ratio and significance levels, as well as through empirical data from an agricultural experiment. According to the findings of the simulation study, when there is no violation of the assumption of normality and the groups have equal variances and equal number of samples, the Bhandary-Dai, Cochran's C, Hartley's Fmax, Levene (trimmed mean) and Bartlett tests are considered robust. The Levene (absolute and square deviations) tests show a high probability of type I error in a small number of samples, which increases as the number of groups rises. When data groups display a nonnormal distribution, researchers should utilize the Levene (trimmed mean), O'Brien and Brown-Forsythe tests. On the other hand, if the assumption of normality is not violated but diagnostic plots indicate unequal variances between groups, researchers are advised to use the Bartlett, Z-variance, Bhandary-Dai and Levene (trimmed mean) tests. Assessing the tests being considered, the test that stands out as the most well-rounded choice is the Levene's test (trimmed mean), which provides satisfactory type I error control and relatively high power. According to the findings of the study and for the scenarios considered, the two non-parametric tests are not recommended. In conclusion, it is suggested to initially check for normality and consider the number of samples per group before choosing the most appropriate test for homoscedasticity.

전류 분배 특성이 향상된 드룹 방법에 관한 연구 (A Study on the Droop Method with Improved Current Distribution Characteristics)

  • 장바울
    • 전기전자학회논문지
    • /
    • 제23권3호
    • /
    • pp.785-792
    • /
    • 2019
  • 다중 컨버터 모듈을 병렬 운전 시, 시스템의 신뢰성 향상을 위해 모듈 간 균등한 전력 분배가 이루어져야 한다. 본 논문에서는 기존의 드룹 제어 방법을 개선하여 전류 분배 특성이 향상된 개선된 드룹 제어 방법을 제시한다. 제안하는 방법에서는 각 모듈의 전류가 설정값보다 커질 경우, 출력 전압 설정값을 상향 조정하여 모듈 간 전류 분배 특성이 개선되도록 한다. 한편, 출력 전압을 공차 범위 안에서 관리하고자 할 때, 출력 전압 설정값이 항상 상향 조정된다면 이용 가능한 제어 IC 기준값($v_{ref}$)의 범위가 줄어들게 된다. 따라서 상향 조정으로 인해 모듈 간 출력 전압 설정값이 역전될 경우 하향 조정을 통해 이를 해결하고자 하였다. 제안하는 방법은 2개의 부스트 컨버터 모듈로 구성된 17.5V/500mA급 프로토타입을 통해 실험으로 검증하였다.

Gumbel 분포형의 수정 Anderson-Darling 검정통계량 유도 및 기각력 검토 (Derivation of Modified Anderson-Darling Test Statistics and Power Test for the Gumbel Distribution)

  • 신홍준;성경민;허준행
    • 한국수자원학회논문집
    • /
    • 제43권9호
    • /
    • pp.813-822
    • /
    • 2010
  • 빈도해석에 있어서 중요한 문제는 특정 재현기간에 대한 수문량의 크기를 산정하는 것으로, 빈도해석에서는 일반적으로 관측기간보다 긴 재현기간에 해당하는 수문량의 크기를 산정하기 위해 가정된 확률분포형을 표본 자료에 적합시키게 된다. 따라서 적절한 확률분포형의 선정이 무엇보다 중요하며 이는 일반적으로 대상 자료로부터 얻어지는 경험적 빈도분포와 가정한 확률분포의 일치 정도를 판단하는 적합도 검정 방법을 이용하게 된다. 일반적으로 많이 사용되는 적합도검정 방법들은 모든 표본 자료들의 적합 정도를 동일하게 고려하기 때문에 극치사상의 크기 증가에 따른 영향은 반영하기 힘든 방법들이다. 따라서 본 연구에서는 모의실험을 통해 극치사상에 대하여 가중치를 주는 modified Anderson-Darling (AD) 검정 방법의 Gumbel 분포형에 대한 검정 통계량 한계값을 제시하였으며, 기존의 여러 적합도 검정 방법과의 기각력을 비교해 보고, 이를 실제 자료에 적용하여 그 결과를 살펴보았다. 그 결과 modified AD 검정 방법이 기존의 여러 가지 적합도 검정 방법보다도 기각력이 더 우수한 것으로 나타났으며, 기존의 적합도 검정 방법으로는 부족한 분포형 선정 기준의 부족한 부분을 어느 정도 보완해 줄 수 있을 것으로 판단되었다.