• 제목/요약/키워드: electron lens

검색결과 144건 처리시간 0.026초

전계방출 주사전자 현미경의 전자광학계 유한요소해석 (Finite Element Analysis for Electron Optical System of a Field Emission SEM)

  • 박근;박만진;김동환;장동영
    • 대한기계학회논문집A
    • /
    • 제30권12호
    • /
    • pp.1557-1563
    • /
    • 2006
  • A scanning electron microscope (SEM) is well known as a measurement and analysis equipment in nano technology, being widely used as a crucial one in measuring objects or analyzing chemical components. It is equipped with an electron optical system that consists of an electron beam source, electromagnetic lenses, and a detector. The present work concerns numerical analysis for the electron optical system so as to facilitate design of each component. Through the numerical analysis, we investigate trajectories of electron beams emitted from a nano-scale field emission tip, and compare the result with that of experimental observations. Effects of various components such as electromagnetic lenses and an aperture are also discussed.

Dielectric 마스크 적용 UV 레이저 프로젝션 가공을 이용한 빌드업 필름 내 선폭 10μm급 패턴 가공 연구 (DPSS UV laser projection ablation of 10μm-wide patterns in a buildup film using a dielectric mask)

  • 손현기;박종식;정수정;신동식;최지연
    • 한국레이저가공학회지
    • /
    • 제16권3호
    • /
    • pp.27-31
    • /
    • 2013
  • To engrave high-density circuit-line patterns in IC substrates, we applied a projection ablation technique in which a dielectric ($ZrO_2/SiO_2$) mask, a DPSS UV laser instead of an excimer laser, a refractive beam shaping optics and a galvo scanner are used. The line/space dimension of line patterns of the dielectric mask is $10{\mu}m/10{\mu}m$. Using a ${\pi}$ -shaper and a square aperture, the Gaussian beam from the laser is shaped into a square flap-top beam; and a telecentric f-${\theta}$ lens focuses it to a $115{\mu}m{\times}105{\mu}m$ flat-top beam on the mask. The galvo scanner before the f-${\theta}$ lens moves the beam across the scan area of $40mm{\times}40mm$. An 1:1 projection lens was used. Experiments showed that the widths of the engraved patterns in a buildup film ranges from $8.1{\mu}m$ to $10.2{\mu}m$ and the depths from $8.8{\mu}m$ to $11.7{\mu}m$. Results indicates that it is required to increase the projection ratio to enhance profiles of the engraved patterns.

  • PDF

Study on terahertz (THz) photoconversion technology based on hyperfine energy-level splitting of Positronium (Ps) generated from relativistic electron beams

  • Sun-Hong Min;Chawon Park;Ilsung Cho;Minho Kim;Sukhwal Ma;Won Taek Hwang;Kyeong Min Kim;Seungwoo Park;Min Young Lee;Eun Ju Kim;Kyo Chul Lee;Yong Jin Lee;Bong Hwan Hong
    • 대한방사성의약품학회지
    • /
    • 제6권2호
    • /
    • pp.102-115
    • /
    • 2020
  • In the state of Positronium (Ps), which is an unstable material created by the temporary combination of electrons and positrons, the imaging technology through photo-conversion methodology is emerging as a new research theme under resonance conditions through terahertz electromagnetic waves. Normally, Positronium can be observed in the positron emission computed tomography (PET) process when an unstable, separate state that remains after the pair annihilation of an electron and a positron remains. In this study, terahertz (THz) waves and Cherenkov radiation (CR) are generated using the principle of ponderomotive force in the plasma wake-field acceleration, and electrons and positrons are simultaneously generated by using a relativistic electron beam without using a PET device. We confirm the possibility of Positronium photoconversion technology in terahertz electromagnetic resonance conditions through experimental studies that generate an unstable state. Here, a relativistic electron beam (REB) energy of 0.5 MeV (γ=2) was used, and the terahertz wave frequencies is G-band. Meanwhile, a THz wave mode converting three-stepped axicon lens was used to apply the photoconversion technology. Through this, light emission in the form of a luminescence-converted Bessel beam can be verified. In the future, it can be used complementarily with PET in nuclear medicine in the field of medical imaging.

써클 및 동일 재질 콘택트렌즈의 임상 적용시 눈에 미치는 영향 (The Effect of Circle Lens and Soft Contact Lens with Identical Material in Clinical Application on the Eyes)

  • 박상희;김소라;박미정
    • 한국안광학회지
    • /
    • 제16권2호
    • /
    • pp.147-157
    • /
    • 2011
  • 목적: 본 연구에서는 써클 콘택트렌즈의 착용 실태를 조사하고, 임상 적용 시 동일재질의 일반 소프트 콘택트렌즈 착용 시의 순목횟수, 비침입성 눈물막 파괴시간 및 렌즈 표면의 차이를 비교하여 착색 여부에 따른 차이를 알아보고자 하였다. 방법: 80명을 대상으로 써클 콘택트렌즈의 착용 실태를 알아보았으며, 20대 20안을 대상으로 하여 동일한 재질 및 파라미터의 일반 소프트 콘택트렌즈와 써클 콘택트렌즈를 각각 5일 동안 착용시킨 후 순목 횟수, 비 침입성 눈물막 파괴시간을 측정하였다. 또한, 주사전자현미경을 이용하여 렌즈의 표면을 관찰하였다. 결과: 써클 콘택트렌즈 교체의 주요 원인이 불편감이라고 답한 응답자가 50%에 달하였으며, 67%가 하루에 6시간 이상을 착용하는 것으로 나타났다. 콘택트렌즈 착용 1일, 3일, 5일째에 눈물막이 안정화된 시점인 착용 30분 후와 3시간 후의 순목 횟수는 두 종류의 렌즈 모두 착용 기간이 증가할수록 증가하는 경향을 보였다. 3일째, 5일째 착용 3시간 후에는 써클 콘택트렌즈 착용 시와 소프트 콘택트렌즈 착용 시의 순목 횟수가 통계적으로 유의한 차이가 나타났다. 콘택트렌즈를 착용한 상태에서의 비침입성 눈물막 파괴시간은 착용 1일째 30분 후 소프트 콘택트렌즈 착용 시는 6.0 초, 써클 콘택트렌즈는 3.7 초로 통계적으로 유의한 차이가 있었다. 착용 3시간 후에도 두 렌즈 사이의 비침입성 눈물막 파괴시간에는 통계적으로 유의한 차이가 있었으며, 착용 3일째와 5일째도 마찬가지였다. 써클 콘택트렌즈와 일반 소프트 콘택트렌즈의 전후면과 써클 콘택트렌즈 후면의 표면조도(surface roughness)는 동일했으나 써클 콘택트렌즈는 착색된 부분인 렌즈 전면부는 균일하지 않고 요철이 많았다. 결론: 써클 콘택트렌즈의 표면 차이가 렌즈 착용 시 습윤성의 차이를 야기하였을 것으로 보이며 그로 인하여 불편감을 느끼게 되었을 것으로 생각되어졌다. 본 연구 결과로 착색으로 인한 써클 콘택트렌즈와 일반 소프트 콘택트렌즈의 차이를 밝혔으므로 건강한 써클 콘택트렌즈의 착용에 도움이 될 수 있으리라 여겨진다.

Finishing 용 전자빔 집속 장치의 성능 실험 (Performance Experiment of Electron Beam Convergence Instrument)

  • 임선종
    • 한국레이저가공학회지
    • /
    • 제18권3호
    • /
    • pp.6-8
    • /
    • 2015
  • Finishing process includes deburring, polishing and edge radiusing. It improves the surface profile of specimen and eliminates the alien substance on surface. Deburring is the elimination process for debris of edges. Polishing lubricates surfaces by rubbing or chemical treatment. There are two types for electron finishing. The one is using pulse beam. The other is using the convergent and scanning electron beam. Pulse type device appropriates the large area process. But it does not control the beam dosage. Scanning type device has advantages for dosage control and edge deburring. We design the convergence and scan type. It has magnetic lenses for convergence and scan device for scanning beam. Magnetic lenses consist of convergent and objective lens. The lenses are designed by the specification(beam size and working distance). In this paper, we evaluate the convergence performance by pattern process. Also, we analysis the results and important factors for process. The important factors for process are beam size, pressure, stage speed and vacuum. These results will be utilized into systematizing pattern shape and the factors.

Morphology of Retinas and Lenses in the Fish of the Genus Zacco (Cypriniformes, Cyprinidae): Possible Relationship with Prey and Habitat

  • Lim, Jae-Won;Lee, Chung-Lyul;Lee, Moo-Sam
    • Animal cells and systems
    • /
    • 제7권4호
    • /
    • pp.331-335
    • /
    • 2003
  • Vertebrates with different habitats have different proportions of visual cells, with the rod cells responding to scotopic vision and the cone cells responding to photopic and color vision in their retinas. The present work studied whether the kinds and arrangement patterns of the cone cells and interlocking morphology of the lens were related to the kind of preys and habitats in the genus Zacco. The retinas were observed by a light microscopy using H-E staining method and the interlocking formula of the lens fibers were investigated by a scanning electron microscopy. The interlocking formula of the lens fibers of Z. temmincki is an ' anchor and socket ' connection, and that of Z. platypus is a ' ball and socket ' connection. The cone cells of Z. platypus and Z. temmincki constituted compacted mosaic patterns of row type. Away from the center, the double and single cone cells gradually increased in diameter. Zacco temmincki had identical double cone cells and Z. platypus had non-identical double and single cone cells. The eyes of Z. temminckifeeding on a moving aquatic insects in relative limpid water and swift current of mid and upper stream have better resolution than that of Z. platypus feeding on mainly adhesive algae and some aquatic insects in slightly turbid water of mid stream.

써클콘택트렌즈가 눈물막 안정성에 미치는 영향 (The Effect of Circle Contact Lens on the Stability of Tear Film)

  • 이세희;형성민;고승환;박미정;김소라
    • 한국안광학회지
    • /
    • 제20권2호
    • /
    • pp.125-131
    • /
    • 2015
  • 목적: 본 연구에서는 써클콘택트렌즈의 착색이 눈물막 안정성에 미치는 영향을 알아보고자 하였다. 방법: 눈물량이 정상인 20대 54안을 대상으로 콘택트렌즈 착용 전후의 비침입성 눈물막파괴시간 및 눈물막 깨짐이 시작되는 부위를 측정하였으며, 콘택트렌즈 전후면의 표면 거칠기를 주사전자현미경으로 관찰하였다. 콘택트렌즈는 hilafilcon B재질의 투명 및 써클콘택트렌즈, polymacon 재질 및 HEMA NVP 공중합 재질의 써클콘택트렌즈를 대상으로 하였다. 결과: 콘택트렌즈 착용 시 나안에 비해 눈물막파괴시간이 통계적으로 유의하게 감소하였으며 써클콘택트렌즈 간에 눈물막파괴시간이 통계적으로 유의한 차이를 보이는 경우도 있었다. 일반적으로 콘택트렌즈의 상방부 보다는 하방부에서, 코방향 보다는 귀방향에서 좀 더 높은 빈도로 눈물막이 깨지기 시작하였으나 렌즈의 종류에 따라 다소 차이가 있었다. Hilafilcon B 투명렌즈에 비해 동일 재질 써클콘택트렌즈 주변부(착색부분)에서의 눈물막 깨짐이 더 많았다. 결론: 써클콘택트렌즈의 착용으로 인해 눈물막 안정성이 영향을 받음을 알 수 있었으며, 본 연구결과는 써클콘택트렌즈 착용 시 착색으로 인하여 나타날 수 있는 문제점 해결의 기초자료로 사용될 수 있을 것으로 보인다.

안경용 초음파세척기에 의한 소프트콘택트렌즈의 단백질 침전물 세척효과 (The Effects of Ultrasonic Cleaner for Eye Glasses on Protein Deposits and Parameters in Soft Contact Lens)

  • 주은희;이군자;임현성
    • 한국안광학회지
    • /
    • 제15권3호
    • /
    • pp.227-234
    • /
    • 2010
  • 목적: 안경용 초음파세척기를 이용하여 소프트콘택트렌즈의 단백질 침전물 세척 효과와 콘택트렌즈의 변수에 미치는 영향을 조사하였다. 방법: 단백질을 오염시킨 etafilcon A 재질의 소프트콘택트렌즈를 다목적용액에 넣어 안경용 초음파세척기와 콘택트렌즈용 초음파세척기를 사용하여 세척하고 대조군의 콘택트렌즈는 다목적용액으로 세척한 후 콘택트렌즈에 남아있는 단백질을 추출하여 정량하였고 콘택트렌즈의 전체지름, 베이스커브, 중심두께, 도수 및 함수율의 변화를 측정하였으며 주사전자현미경(scanning electron microscope)으로 콘택트렌즈 표면을 관찰하였다. 결과: 단백질을 오염시킨 etafilcon A 재질의 콘택트렌즈는 다목적용액에 의해 6.08%의 세척효과를 보였고, 다목적용액에 콘택트렌즈를 넣고 초음파세척기로 세척한 경우에는 시간에 따라 안경용 초음파세척기에서는 23.73~33.92%, 콘택트렌즈용 초음파세척기에서는 0~12.99%의 세척효과를 보였다. 결론: 안경용 초음파세척기로 세척한 콘택트렌즈에서 변수 및 표면 변화는 관찰되지 않았다. 결론: 안경원에서 사용하는 안경용 초음파세척기는 소프트콘택트렌즈의 단백질 침전물 제거에 효과적이고 변수 변화를 유발하지 않아 안경원에서 진단용 소프트렌즈의 세척에 활용될 수 있을 것으로 사료된다.

RGP Contact Lens 표면 미세구조에 대한 사용 효과의 연구 (A Study of the Effects of Use upon RGP Contact Lens Surface Ultrastructure)

  • 김덕훈;성아영
    • 한국안광학회지
    • /
    • 제11권1호
    • /
    • pp.71-75
    • /
    • 2006
  • 본 연구의 목적은 사용한 RGP 콘택트렌즈의 표면 미세구조의 분석을 한 것이다. 조사를 위해 RGP콘택트렌즈는 피검자에 의해 1개월, 6개월 그리고 1년 사용한 것을 선택하였다. 이러한 RGP 콘택트렌즈의 전후 표면은 주사전자현미경으로 조사를 하였다. 그 결과는 다음과 같다. 1. RGP 콘택트렌즈 사용 1개월 후 전면과 후면의 표면은 선명하고 깨끗하였다. 2. 6개월 사용 렌즈의 전방 표면은 심한 반흔, 상처 자국, 파손 그리고 긁힘을 가지고 있었다. 그러나 후방 표면은 심한 이물질과 미생물 등이 나타났다. 3. 1년 사용렌즈는 좀더 심한 큰 반흔 손상과 많은 이물질들이 관찰되었다. 따라서 RGP 콘택트렌즈의 연장착용은 렌즈표면의 미세구조의 증가된 물리적인 손상과 심한 이물질의 누적을 나타내었다.

  • PDF