• 제목/요약/키워드: electrochemical sensor

검색결과 361건 처리시간 0.023초

Highly Sensitive and Selective Glucose Sensor Realized by Conducting Polymer Modified Nanoporous PtZn Alloy Electrode

  • Jo, Hyejin;Piao, Hushan;Son, Yongkeun
    • Journal of Electrochemical Science and Technology
    • /
    • 제4권1호
    • /
    • pp.41-45
    • /
    • 2013
  • Platinum is a well known element which shows a significant electrocatalytic activity in many important applications. In glucose sensor, because of the poisoning effect of reaction intermediates and the low surface area, the electrocatalytic activity towards the glucose oxidation is low which cause the low sensitivity. So, we fabricate a nanoporous PtZn alloy electrode by deposition-dissolution method. It provides a high active surface and a large enzyme encapsulating space per unit area when it used for an enzymatic glucose sensor. Glucose oxidase was immobilized on the electrode surface by capping with PEDOT composite and PPDA. The composite and PPDA also can exclude the interference ion such as ascorbic acid and uric acid to improve the selectivity. The surface area was determined by cyclic voltametry method and the surface structure and the element were analyzed by Scanning Electron Microscope (SEM) and Energy Dispersive X-ray spectroscopy (EDX), respectively. The sensitivity is $13.5{\mu}A/mM\;cm^2$. It is a remarkable value with such simply prepared senor has high selectivity.

CNT 필름 전기화학 센서의 온도 의존 특성에 관한 연구 (Temperature-Dependent Characteristics of Carbon Nanotubes-Film-Based Electrochemical Sensor)

  • 노재하;안형수;안상수;이창한;이상태;이문진;서동민;장지호
    • 센서학회지
    • /
    • 제31권3호
    • /
    • pp.163-167
    • /
    • 2022
  • In this study, we investigated a carbon nanotube (CNT) film sensor to detect hazardous and noxious substances distributed in seawater. The response change of the sensor was studied according to environmental temperature, and its temperature coefficient of resistance (TCR, α) was measured. The temperature of the CNT film (~50 ㎛) was in the range of 20-50 ℃, and αCNT was calculated to be -0.0011 %/ ℃. We experimentally confirmed that the CNT film had a smaller TCR value than that of the conventional sensor. Therefore, we investigated the response change of the CNT sensor according to temperature. The CNT sensor showed a relatively small error of approximately 2.3 % up to 30 ℃, which is within the temperature range of the seawater of the Korean Peninsula. However, when the temperature exceeded 40 ℃, the error in the CNT sensor increased by more than 5.2 %. We fabricated a metal oxide (ITO, indium-tin-oxide) film and compared its performance with that of the CNT sensor. The ITO sensor showed an error of >12.5 % at 30 ℃, indicating that in terms of the stability of the sensor to temperature, the CNT film sensor has superior performance.

Electrochemical Determination of Capsaicin by Ionic Liquid Composite-Modified Electrode

  • Kim, Dong-Hwan;Nam, Sungju;Kim, Jaeyoon;Lee, Won-Yong
    • Journal of Electrochemical Science and Technology
    • /
    • 제10권2호
    • /
    • pp.177-184
    • /
    • 2019
  • An electrochemical detection method for capsaicin has been developed using ionic liquid (IL) doped graphene-titania-Nafion composite-modified electrode. The combination of IL (1-hexyl-3-methylimidazolium with hexafluorophosphate counter ion) in the composite-modified electrode resulted in a significantly increased electrochemical response for capsaicin compared to that obtained at the corresponding electrode without IL. The increased electrochemical signal could be ascribed to the decreased electron transfer resistance through the composite film and also to the effective accumulation of capsaicin on the electrode surface due to ${\pi}-{\pi}$ interaction of the imidazole groups of IL with the aromatic rings of capsaicin. The present IL composite-modified electrode can detect capsaicin with a concentration range from $3.0{\times}10^{-8}M$ to $1.0{\times}10^{-5}M$ with a detection limit of $3.17{\times}10^{-9}M$ (S/N = 3). The present sensor showed good reproducibility (RSD = 3.2%).

Improved Sensitivity of a Glucose Sensor by Encapsulation of Free GOx in Conducting Polymer Micropillar Structure

  • Jung, Shin-Hwan;Lee, Young-Kwan;Son, Yong-Keun
    • Journal of Electrochemical Science and Technology
    • /
    • 제2권2호
    • /
    • pp.124-129
    • /
    • 2011
  • A simple process of fabricating micropillar structure and its influence upon enhancing electrochemical biosensor response were studied in this work. Conducting polymer PEDOT was used as a base material in formulating a composite with PVA. Micro porous PC membrane filter was used as a template for the micropillar of the composite on ITO electrode. This structure could provide plenty of encapsulating space for enzyme species. After dosing enzyme solution into this space, Nafion film tent was cast over the pillar structure to complete the micropillar cavity structure. In this way, the encapsulation of enzyme could be accomplished without any chemical modification. The amount of enzyme species was easily controllable by varying the concentration of the dosing solution. The more amount of enzyme is stored in the sensor, the higher the electrochemical response is produced. One more reason for the sensitivity improvement comes from the large surface area of the micropillar structure. Application of 0.7 V produced the best current response under the condition of pH 7.4. This biosensor showed linear response to the glucose in 0.1~1 mM range with the average sensitivity of $14.06{\mu}A/mMcm^2$. Detection limit was 0.01 mM based on S/N = 3.

Simple Preparation of Diaphorase/Polysiloxane Viologen Polymer Modified Electrode for Sensing NAD and NADH

  • Song, Ji-Eun;Hong, Zhenyu;Nagarale, Rajaram Krishna;Shin, Woon-Sup
    • Journal of Electrochemical Science and Technology
    • /
    • 제2권3호
    • /
    • pp.163-167
    • /
    • 2011
  • Nicotinamide adenine dinucleotide, $NAD^+$, and its reduced form, NADH, play important roles as coenzymes in many enzymatic reactions. Electrochemical methods for $NAD^+$ or NADH detection or generation are drawn attention because it can provide the simple and low cost platform with fairly good sensitivity. In this study, the polysiloxane viologen polymer/diaphorase/hydrophilic polyurethane (PSV/DI/HPU) modified electrodes were simply prepared and demonstrated for bio-electrocatalytic $NAD^+$ sensors. The electrodes were co-immobilized with diaphorase and polysiloxane viologen polymer as an electron mediator followed by the overcoating with HPU membrane. The mixture of the enzyme and the electron mediator was well stabilized within HPU membrane and exhibited good reversibility and stability. The sensitivity was 0.2 $nA{\cdot}{\mu}M^{-1}$ and the detection limit was 28 ${\mu}M$ with a response time of 50 s ($t_{90%}$). The capability for NADH sensor was also observed on the PSV/DI/HPU electrode.

소금용액에 포함된 글루코오스 농도의 전기화학적 측정 (Electrochemical Determination of Glucose Concentration Contained in Salt Solution)

  • 김영한
    • 한국항만학회지
    • /
    • 제14권4호
    • /
    • pp.475-479
    • /
    • 2000
  • A possibility of the implementation of a quartz crystal sensor to the determination of chemical oxygen demand is examined by checking the electrochemical behavior of the sensor in a glucose solution. Since the surface of a quartz crystal has to be oxidized, a relatively active metal is coated on the surface of a usual 9 MHz AT-cut crystal. The electrochemical behavior is investigated by measuring the changes of current, resonant frequency and resonant resistance while a constant potential is applied. The crystal is installed in a specially designed container, and a quartz crystal analyzer is utilized to measure the frequency and resistance simultaneously. The variations of the measurements are examined at different concentrations of glucose solution, and a proper relation between the concentrations of glucose solution, and a proper relation between the concentration and the measurements is analyzed. As a result, it is found that a linear relation between the concentration of less than 900 ppm and the peak current when a constant potential of -180 mV (SSCE) is applied. The relation can be utilized for the determination of glucose concentration in sea water, and considering a direct relation between gluose concentration and chemical oxygen demand tells a possibility of the measurement of chemical oxygen demand using quartz crystal oscillators.

  • PDF

Daily Amperometric Monitoring of Immunoglobulin E in a Mouse Whole Blood: Model of Ovalbumin Induced Asthma

  • Lee, Ju Kyung;Yoon, Sung-hoon;Kim, Sang Hee
    • 전기화학회지
    • /
    • 제25권1호
    • /
    • pp.13-21
    • /
    • 2022
  • There is an increasing interest in monitoring of specific biomarker for determining progression of a disease or efficacy of a treatment. Conventional method for quantification of specific biomarkers as enzyme linked immunosorbent assay (ELISA) has high material costs, long incubation periods, requires large volume of samples and involves special instruments, which necessitates clinical samples to be sent to a lab. This paper reports on the development of an electrochemical biosensor to measure total immunoglobulin E (IgE), a marker of asthma disease that varies with age, gender, and disease in concentrations from 0.3-1000 ng/mL with consuming 20 µL volume of whole blood sample. The sensor provides rapid, accurate, easy, point-of-care measurement of IgE, also, sequential monitoring of total IgE with ovalbumin (OVA) induced mice is another application of sensor. Taken together, these results provide an alternative way for detection of biomarkers in whole blood with low volumes and long-term ex-vivo assessments for understanding the progression of a disease.

용존산소 측정을 위한 무선통신 기반 휴대형 포텐쇼스탯 개발 (Development of a Portable Potentiostat with Wireless Communications for Measuring Dissolved Oxygen)

  • 이현석;한지훈;박정호
    • 전기학회논문지
    • /
    • 제67권12호
    • /
    • pp.1641-1647
    • /
    • 2018
  • In this paper, we describe a portable potentiostat which is capable of cyclic voltammetry(CV) and amperometry for electrochemical dissolved oxygen sensor. In addition, this portable potentiostat can also transmit the measured data wirelessly to android devices such as smart phone, tablet, etc. through Bluetooth. The potentiostat system consists of three parts; a voltage generator circuit which is controlled by Arduino nano and 12-bit DAC(digital to analog converter) to generate necessary electric potential for operating the electrochemical sensor, an oxidation/reduction current measurement circuit, and a Bluetooth module to transmit data wirelessly to an android device. Once measurements are carried out with the android application, the measured data is transmitted to the android device via Bluetooth and displayed using the android app. in real time. In this paper, we report the measured reduction current with a fabricated dissolved oxygen sensor in both saturated-oxygen state and zero-oxygen states. The results of the developed portable potentiostat system are in good agreement with those of the commercial portable potentiostat (${\mu}stat200$, Dropsens inc.). The measured peak reduction currents using the developed potentiostat and the commercial ${\mu}stat200$ potentiostat were $-0.755{\mu}A$ and $-0.724{\mu}A$, respectively. The reduction currents measured at zero-oxygen state were $-0.005{\mu}A$ and $-0.004{\mu}A$. The discrepancy between those two systems seems very small, which implies successful development of a portable and wireless potentionstat.

산화물계 고체전해질 함량에 따른 PEO 기반 복합전해질 전기화학 성능 연구 (Study on Electrochemical Performances of PEO-based Composite Electrolyte by Contents of Oxide Solid Electrolyte)

  • 이명주;김주영;오지민;김주미;김광만;이영기;신동옥
    • 전기화학회지
    • /
    • 제21권4호
    • /
    • pp.80-87
    • /
    • 2018
  • 웨어러블 디바이스, 전기자동차와 에너지저장시스템에 대한 전력 수요가 증가함에 따라 리튬이온 전지에 있어서 안전성은 가장 중요한 요소가 되었다. 이러한 문제를 해결하기 위해 가연성의 유기 액체전해질이 불연성의 고체전해질로 대체된 전고체 전지를 제조하려는 연구들이 진행되고 있다. 그러나 고체전해질은 자체 이온전도도가 상대적으로 낮고 전극/전해질 계면에서 높은 저항이 발생하므로 실질적인 활용에 제약이 있었다. 이에 유무기 소재로 구성된 복합전해질은 고체전해질의 단점을 극복할 수 있는 대안으로 떠오르고 있다. 본 연구에서는 PEO 전해질과 LLZO 고체전해질을 복합화하여 전해질을 제조하였고, LLZO 고체전해질 함량에 따라 결정성, 형상 및 전기화학 성능 분석을 진행하였다. 결과로부터 PEO 전해질 내에 LLZO 고체전해질의 최적 함량 및 균일한 분포가 전체 복합전해질의 이온전도도 향상에 중요한 요소임을 확인하였다.