• Title/Summary/Keyword: duty factor

Search Result 363, Processing Time 0.027 seconds

Implementation of Single-Phase Bridgeless Voltage Doubler for Power Factor Correction (역률개선용 단상 브리지리스 배전압 변환기의 구현)

  • Koo, Do-Yeon;Lim, Seung-Beom;Seo, Young-Min;Hong, Soon-Chan
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.3-4
    • /
    • 2012
  • 역률개선용 변환기는 입력전류를 교류전원과 동상으로 제어하여 다이오드 정류기에 비해 역률을 개선하고 THD를 저감시킬 수 있다. 본 논문에서는 단상 역률개선용 배전압 변환기를 IP 제어기와 Anti Wind-up Control을 사용하여 출력전압의 크기를 안정되게 제어하며 PI 제어기와 Anti Wind-up Control을 사용하여 입력전류가 입력전압과 동상이 되도록 제어한다. 또한 Duty-ratio Feed Forward Control을 사용하여 디지털 제어에 의한 진상현상을 저감시킨다. 본 논문에서는 소형화와 경량화가 가능하고 출력전압이 높은 역률개선용 단상 브리지리스 배전압 변환기를 구현한다.

  • PDF

A new hybrid control scheme for reduction of secondary diode voltage stresses Based on interleaved PFC Asymmetrical Half Bridge Topology (Asymmetrical 반브리지 컨버터의 이차측 다이오드 전압스트레스저감을 위한 새로운 하이브리드 제어기법)

  • Park, Nam-Ju;Lee, Dong-Yun;Hyun, Dong-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1416-1418
    • /
    • 2005
  • This paper presents a new hybrid control method of asymmetrical half-bridge converter(AHBC) with low voltage stresses of the diodes and interleaved PFC(power factor correction). The proposed new control scheme can observe variation of secondary diodes voltage stresses by variation of duty ratio and then decide the control portions which are asymmetrical control and PFM(Pulse Frequency Modulation). Therefore, the proposed control scheme has many advantages such as a low rated voltage of the secondary diodes, low conduction loss according to the low voltage drop and wide zvs range by load variation. Through simulation results, the validity of the proposed control scheme is demonstrated.

  • PDF

Dimming Control in Visible Light Communication Using Subcarrier Modulation of Manchester Code (맨체스터 코드의 부반송파 변조를 이용한 가시광통신의 조명제어)

  • Lee, Seong-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.28 no.3
    • /
    • pp.191-197
    • /
    • 2019
  • In this study, we propose a dimming control method for a visible light communication (VLC) system, in which the subcarrier on-off keying (OOK) modulation of Manchester code is used for data transmission. In the VLC transmitter, non-return-to-zero (NRZ) code data is transformed to Manchester code, which is OOK modulated with a subcarrier. Manchester code is used for flicker-free lighting; the duty factor is changed for dimming control, and the subcarrier is used for preventing the adjacent noise light interference. In the experiments, the dimming control was carried out from about 8%-92% of the continuous wave (CW) LED light. This configuration is simple and effective in constructing a VLC system for indoor wireless sensor networks with flicker-free illumination and dimming control capability without adjacent noise light interference.

Double Step-Up PFC Converter Using Asymmetrical PWM Scheme (비대칭 PWM 방식을 이용한 이중 승압 기능을 갖는 PFC 컨버터)

  • Yeongjin Kim;Jaeseong Lim;Honnyong Cha
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.28 no.1
    • /
    • pp.8-14
    • /
    • 2023
  • This paper proposes a PFC converter with a double step-up function using an asymmetrical PWM scheme. For the conventional PWM scheme, the input voltage range, which maintains a double step-up function, is limited because the proposed converter has different voltage gains and characteristics when the duty ratio(D) is less than 0.5. The proposed converter has a constant voltage gain regardless of the magnitude of the input voltage and can achieve output voltage balancing by using the asymmetrical PWM scheme. A 1.6-kW prototype of the proposed converter was built and tested to verify the performance.

The Design of Single Phase PFC using a DSP (DSP를 이용한 단상 PFC의 설계)

  • Yang, Oh
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.44 no.6
    • /
    • pp.57-65
    • /
    • 2007
  • This paper presents the design of single phase PFC(Power Factor Correction) using a DSP(TMS320F2812). In order to realize the proposed boost PFC converter in average current mode control, the DSP requires the A/D sampling values for a line input voltage, a inductor current, and the output voltage of the converter. Because of a FET switching noise, these sampling values contain a high frequency noise and switching ripple. The solution of A/D sampling keeps away from the switching point. Because the PWM duty is changed from 5% to 95%, we can#t decide a fixed sampling time. In this paper, the three A/D converters of the DSP are started using the prediction algorithm for the FET ON/OFF time at every sampling cycle(40 KHz). Implemented A/D sampling algorithm with only one timer of the DSP is very simple and gives the autostart of these A/D converters. From the experimental result, it was shown that the power factor was about 0.99 at wide input voltage, and the output ripple voltage was smaller than 5 Vpp at 80 Vdc output. Finally the parameters and gains of PI controllers are controlled by serial communication with Windows Xp based PC. Also it was shown that the implemented PFC converter can achieve the feasibility and the usefulness.

Understanding Pollutant Emission in a Heavy-Duty Diesel Engine with JP-8 and Diesel (대형 디젤 엔진에서 JP-8 과 디젤 적용 시의 배기 배출물 특성에 대한 이해)

  • Lee, Jin-Woo;Bae, Choong-Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.12
    • /
    • pp.1375-1381
    • /
    • 2011
  • Combustion processes in an optically-accessible single-cylinder heavy-duty diesel engine equipped with a highpressure common-rail injection system were investigated for JP-8 and diesel. Direct imaging and two-color thermometry were employed to verify the emission trend for both fuels. The combustion process was characterized by image analysis with focus on luminosity. The results of two-color thermometry were analyzed on the basis of the flame temperature and KL factor distribution. Analysis of the combustion process by direct imaging showed that the ignition delay was longer for JP-8 than for diesel, while the flame was extinguished rapidly. Analysis of the flame luminosity showed that the combustion intensity was higher for diesel and that the flame lasted for a longer duration in this case. Two-color thermometry results showed that the high-temperature region extended over a large area during JP-8 combustion, implying the formation of a large amount of $NO_x$. In addition, the KL factor showed low level over a large area and relatively homogeneous in the case of JP-8 combustion, which implied that less smoke was produced when using this fuel.

Effect on Body Guards Task Stress has in ferment of enzyme (경호원의 직무스트레스가 항산화효소에 미치는 영향)

  • Roh, Sun-Pyo
    • Korean Security Journal
    • /
    • no.18
    • /
    • pp.21-37
    • /
    • 2009
  • The purpose of study were the effect of stress levels and duty type of guarder on 8-OHdG(hydroxydeoxyguanosin), Immunoglobin, T-cell, NK-cell and antioxidant enzyme. The subject of this study is people who have the guard's career over 2 years. A group of object sample consists of sixty guards carrying the guardbusiness. The group division and distribution of the number of persons a group divided into the guard group of international factor(N=23), private guard group(N=23),and the others(N=14) as a group following the guardbusiness. The group following a stress level divided into 3groups as their score of stress measure; low stress group(N=14), middle stress group(N=26),and high stress group(N=20). In the office type, the experiment sampling the blood, analysing result of following the office type and stress had a conclusion after measuring stress as the followings. The stress level in the office type of guard showed highly in the guard group of international factor(p<.05). Finally we knew that the guard have different stress levels in the office type, even the immune function and the activation of superoxide dismutase affected them in the stress level. Stress showing in the guard career can do them an injury so it is desirable for the guard themselves to participate in the activities settling their stresses and in the development of exercise programs.

  • PDF

A Study on the Utility Interactive Photovoltaic System using a Chopper and a PWM Inverter (쵸퍼와 PWM 전압형 인버터를 이용한 계통연계형 태양광발전시스템에 관한 연구)

  • 유택빈;성낙규;이승환;김성남;이훈구;한경희
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.3 no.2
    • /
    • pp.131-137
    • /
    • 1998
  • The solar cells should be operated at the maximum power point because its output characteristics are greatly fluctuated on the variation of insolation, temperature and load. Photovoltaic system needs an inverter which can interface the dc output power of solar cell with the residential ac load. The inverter has to supply a sinusoidal current and voltage to the load and the utility line with a high power factor. This paper proposes an utility interactive photovoltaic system designed with a step-up chopper and a PWM voltage source inverter. The step-up chopper operates in continuous mode by adjusting the duty ratio so that the photovoltaic system tracks the maximum power points of solar cell without any influence on the variation of insolation and temperature. The voltage source inverter operates in a manner that its output voltage is in phase with the utility voltage. The inverter supplies an ac power with high factor and low level of harmonics to the load and the utility power system.

A Novel Step-up AC-DC Converter with PFC by Discontinuous Current Control (전류불연속 제어에 의한 새로운 PFC 승압형 AC-DC 컨버터)

  • Kim, Choon-Sam;Shim, Jae-Sun;Kim, Chun-Sik;Lee, Hyun-Woo;Kwak, Dong-Kurl
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.2
    • /
    • pp.142-148
    • /
    • 2006
  • In this paper, authors propose a novel step-up AC-DC converter operated with power factor correction (PFC) and with high efficiency. The proposed converter behaves with discontinuous current control (DCC) of input current. The input current waveform in the proposed converter is got to be a discontinuous sinusoid form in proportion to magnitude of at input voltage under the constant duty cycle switching. Therefore, the input power factor is nearly unity and the control method is simple. In the general DCC converters, the switching devices are turned-on with the zero current switching (ZCS). But turn-off of the switching devices is done at the maximum current. To achieve a soft switching at turn-off, the proposed converter uses a new partial resonant circuit, which results in the very low switching loss and the high efficiency of converter.

Boost AC-DC Converter of High Power Factor and High Efficiency (고역률 고효율 승압형 AC-DC 컨버터)

  • Kwak, Dong-Kurl;Kim, Choon-Sam;Park, Ha-Yong;Shim, Jae-Sun;Shim, Sang-Heung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.7
    • /
    • pp.45-52
    • /
    • 2005
  • This paper is studied on boost AC-DC converter of high power factor and high efficiency for discontinuous current control. The converter operated in discontinuous current control eliminates the complicated circuit control requirement, and reduces a number of components. The input current waveform in proposed circuit is got to be a discontinuous sinusoidal form in proportion to magnitude of ac input voltage under the constant duty cycle switching. Therefore, the input power factor is nearly unity and the control circuit is simple. Also the switching devices in a proposed circuit are operated with soft switching by the partial resonant method. The result is that the switching loss is very low and the efficiency of system is high. The partial resonant circuit makes use of a inductor using step up and loss-less snubber capacitor. The circuit topology of the converter is simplified. Some simulative results on computer and experimental results are included to confirm the validity of the analytical results.