• 제목/요약/키워드: dimensionless numbers

검색결과 84건 처리시간 0.028초

돌출 발열블록 표면에서의 배열 충돌제트에 의한 열전달 특성 (Heat transfer characteristics of multiple slot jets at the surface of protruding heated blocks)

  • 정인기;박시우;홍성호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.274-279
    • /
    • 2001
  • An experimental investigation of heat transfer characteristics at the surface of two-dimensional protruding heated blocks using confined impinging multiple slot jets has been performed. The effects of jet-to-jet distances(S=16B, 24B), dimensionless nozzle-to-block distances(H/B=2, 6) and jet Reynolds numbers(Re=2000, 3900, 5800, 7800) on the local and average heat transfer coefficients have been examined with five isothermally heated blocks at streamwise block spacing(p/w=1). To clarify local heat transfer characteristics, naphthalene sublimation technique was used. From the results, it was found that the local and average heat transfer of heated blocks increases with decreasing jet-to-jet distance and increasing jet Reynolds number. Measurements of local heat transfer coefficients have given an indication of the nature of the interaction between jets and of the uniformity of heat transfer obtainable with various arrangements. In the case of S/B=16, H/B=6 and Re=7800, maximum average Nusselt number of overall blocks was obtained.

  • PDF

재료의 특징에 따른 국부화에 대한 수치해석적 연구 (A Study of Localization with Material Properties Using Numerical Method)

  • 황두순;이병섭;이용성;윤수진;홍성인
    • 소성∙가공
    • /
    • 제9권4호
    • /
    • pp.395-403
    • /
    • 2000
  • Formation of Shear Band under the adiabatic condition is widely observed In the engineering materials during rapidly forming process lot a thermally rate-dependent material. The shear band stems from evolution of a narrow region in which an intensive plastic flow occurs. The shear band often plays a role of a precursor of the ductile fracture during a forming process. The objective of this study is to investigate the localization behavior using numerical method. In this work, the implicit finite difference scheme is employed due to the ease of convergence and the numerical stability It is noted that physical and mechanical properties of materials determine how the shear band is formed and then localized. Material properties can be characterized with inertia number dissipation number and diffusion number. It is observed that the dimensionless numbers effect on localization. Using a parametric study, comparison was made between CRS-1018 steel with WHA (tungsten heavy alloy). The deformation behavior of material in this study include an isotropic hardening as well as thermal softening. Moreover, this study suggests that a kinematic hardening constitutive relation be required to predict a more accurate strain level at a shear band.

  • PDF

이원용액의 응고현상에 관한 실험적 연구 (An experimental study on solidification of binary mix-ture)

  • 조한승;최희탁;유재석
    • 태양에너지
    • /
    • 제12권3호
    • /
    • pp.107-115
    • /
    • 1992
  • 혼합물의 응고과정에서 온도구배와 농도구배에 의한 복합자연대류의 영향을 정성적으로 알아보기 위하여 이원용액의 응고과정을 실험적으로 연구하였다. 이원용액으로는 $NH_4Cl-H_2O$용액을 사용하였으며 shadowgraph system을 이용하였다. 사진에서 고상영역과 mushy zone의 구별이 불가능하여, 이 두 영역을 합하여 고상으로 취급하였다. 자연대류의 영향으로 상변화물질은 매우 빨리 성층화가 이루어지며, 벽면으로부터 형성되는 고상은 초기에는 높이의 20%되는 곳이 가장 빨리 응고가 진행되어 고상의 두께는 이 지점으로부터 상하로 선형적으로 감소하는 형태를 유지한다. 그러나 고상이 많이 형성된 부분의 열저항은 증가하게 되므로 시간이 지남에 따라 두께가 균일화되려는 경향을 보였다. 응고질량비를 $(Ste{\cdot}Ra^{1/4})^{2-Ste}{\cdot}Fo^{1/2}$의 선형함수로 표시할 수 있었으며, 이로부터 농도구배에 의한 자연대류의 영향은 온도구배에 의한 자연대류의 영향에 비하여 작음을 알 수 있었다.

  • PDF

근사수평 반류성층 2상유동에서의 계면전단응력 및 마찰계수 (Interfacial shear stresses and friction factors in nearly-horizontal countercurrent stratified two-phase flow)

  • 이상천;이원석
    • 대한기계학회논문집
    • /
    • 제12권1호
    • /
    • pp.116-122
    • /
    • 1988
  • 본 연구에서는 공기와 물을 매질로 사용하여 3차원 계면파가 존재하는 근사수평 반류성층유동에서의 계면전단응력과 마찰계수를 결정하였다. 기상과 액상의 유량조건에 따라 3차원 계면파의 특성을 needle contact법에 의하여 측정 하였으며, 기상의 압력강하와 속도분포를 구하여 계면전단응력을 구하였다. 또 공학적인 응용을 위하여 3차원과 영역에서의 계면마찰계수에 관한 실험식을 개발하였다. 그리고 거칠은 고체표면에서의 마찰계수를 표현한 Nikuradse식을 이용하여 계면의 등가조도(equivalent roughness)를 계산하였으며 이것을 계면의 파고교란강도와 비교분석하여 계면전단응력에 영향을 미치는 인자들을 규명하였다.

이산화탄소의 증발열전달 특성에 관한 실험적 연구 (An Experimental Study on the Characteristics of Evaporative Heat Transfer of Carbon Dioxide)

  • 조은석;윤석호;김민수
    • 설비공학논문집
    • /
    • 제14권1호
    • /
    • pp.38-45
    • /
    • 2002
  • Evaporative heat transfer characteristics of carbon dioxide have been investi- gated by experiment. The experiments have been carried out for a seamless stainless steel tube of the outer diameter of 9.55 mm, the inner diameter of 7.75 mm and the length of 5.0 m. Direct heating method was used for supplying heat to the refrigerant where the test tube was uniformly heated by electric current which was applied to the tube wall. Experiments were conducted with$CO_2$of purity 99.99% at saturation temperatures of 0.0 to 10.5$^{\circ}C$, heat fluxes of 12 to 27kW/$m^2$s and mass fluxes of 212 to 530 kg/$m^2$s. The heat transfer coefficients of $CO_2$are decreased as the vapor quality increases and these phenomena are explained by dimensionless Weber and Bond numbers. The heat transfer coefficients of$CO_2$increase when the heat and mass fluxes increase, and the saturation temperature effects are minor in the test range of this study. The present experimental data are compared with six renowned correlations with root-mean-squared deviations ranging from 23.0 to 94.9% respectively.

Numerical investigation on the wave interferences of submerged bodies operating near the free surface

  • Li, Dong;Yang, Qun;Zhai, Lin;Wang, Zhen;He, Chuan-lin
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제13권1호
    • /
    • pp.65-74
    • /
    • 2021
  • A key factor that governs the wave interferences of a submerged body is the dimensionless Froude number. Computational Fluid Dynamics (CFD) is used to describe the resistance force coefficients and the generated waves of two SUBOFF submarine models. Grid independence studies are performed on two cases, totally and shallowly submerged cases, with four sets of computing meshes. The highest peaks are marked by red points at given wavelengths, a line is fitted to those points with a least-squares approximation, and the half wake angle at multiple Froude numbers is defined between the fitted line and the centerline of the free surface. The results show that when the depth of the target is 1.1D, constructive interferences occur at Fn = 0.3 and 0.5, while destructive interference occurs at Fn = 0.35 with distortion of the waveform. The half wake angle is less than 19.47° because of the interference between the bow and stern wave systems.

확장된 slip-weakening 모델의 응력 강하량과 에너지 수지 특성 및 스케일링 관계 (Characteristics of Stress Drop and Energy Budget from Extended Slip-Weakening Model and Scaling Relationships)

  • 최항;윤병익
    • 한국지진공학회논문집
    • /
    • 제24권6호
    • /
    • pp.253-266
    • /
    • 2020
  • The extended slip-weakening model was investigated by using a compiled set of source-spectrum-related parameters, i.e. seismic moment Mo, S-wave velocity Vs, corner-frequency fc, and source-controlled high-cut frequency fmax, for 113 shallow crustal earthquakes (focal depth less than 25 km, MW 3.0~7.5) that occurred in Japan from 1987 to 2016. The investigation was focused on the characteristics of stress drop, radiation energy-to-seismic moment ratio, radiation efficiency, and fracture energy release rate, Gc. The scaling relationships of those source parameters were also investigated and compared with those in previous studies, which were based on generally used singular models with the dimensionless numbers corresponding to fc given by Brune and Madariaga. The results showed that the stress drop from the singular model with Madariaga's dimensionless number was equivalent to the breakdown stress drop, as well as Brune's effective stress, rather than to static stress drop as has been usually assumed. The scale dependence of stress drop showed a different tendency in accordance with the size category of the earthquakes, which may be divided into small-moderate earthquakes and moderate-large earthquakes by comparing to Mo = 1017~1018 Nm. The scale dependence was quite similar to that shown by Kanamori and Rivera. The scale dependence was not because of a poor dynamic range of recorded signals or missing data as asserted by Ide and Beroza, but rather it was because of the scale dependent Vr-induced local similarity of spectrum as shown in a previous study by the authors. The energy release rate Gc with respect to breakdown distance Dc from the extended slip-weakening model coincided with that given by Ellsworth and Beroza in a study on the rupture nucleation phase; and the empirical relationship given by Abercrombie and Rice can represent the results from the extended slip-weakening model, the results from laboratory stick-slip experiments by Ohnaka, and the results given by Ellsworth and Beroza simultaneously. Also the energy flux into the breakdown zone was well correlated with the breakdown stress drop, ${\tilde{e}}$ and peak slip velocity of the fault faces. Consequently, the investigation results indicate the appropriateness of the extended slip-weakening model.

수직관내(垂直管內)를 흘러내리는 액막식(液膜式) 흡수기(吸收器)의 흡수(吸收) 및 열전달특성(熱傳達特性)(제(第)2보(報) 열전달특성(熱傳達特性)) (Characteristics of Absorption and Heat Transfer for Film Falling along a Vertical Inner Tube (2nd. Report, Characteristics of Heat Transfer))

  • 엄기찬;이동호;최국광;카시와기 타카오;서정윤
    • 설비공학논문집
    • /
    • 제5권4호
    • /
    • pp.257-264
    • /
    • 1993
  • This is the second report of a three part study on the absorption and heat transfer characteristics of absorber, the correlation of refrigerating capacity and heating capacity. The 2nd report deals with the heat transfer characteristics of a vertical falling film type absorber of inner copper tube. The solute is LiBr-Water solution(60wt%) and the solvent is water vapor. The film Reynoles numbers are varied in the range of 35~130. The states of LiBr solution at the top of absorber are supercooled liquid and superheated liquid. The results are summarized as follows ; Heat transfer results reveal that for the absorption of falling film, the state of LiBr solution appears to be influential in determining the heat transfer. Thus, for the state of supercooled liquid, heat transfer coefficient decreases with increasing the film Reynolds number, but in the condition of superheated liquid, it increases conversely. The mass transfer coefficients that were presented in the 1st.report and heat transfer coefficients of this paper are presented as the dimensionless correlation. The optimum water flowrate which brings about maximum value of heat flux in the film exists, and that increases with increasing the cooling water temperature.

  • PDF

CANDU-6 원자로 감속재 열수력 개별영향실험을 위한 축소화 기법에 따른 1/8 축소형 HU-KINS 설계 (Design of the 1/8 Scaled HU-KINS Based on the Scaling Laws for the Experimental Investigation of Thermal-Hydraulic Effect of CANDU-6 Moderator)

  • 이재영;김만웅;김남석
    • 대한기계학회논문집B
    • /
    • 제30권9호
    • /
    • pp.825-833
    • /
    • 2006
  • To investigate the moderator coolability for CANDU-6 reactors, a test facility (HU-KINS) has been manufactured as a 1/8 scaled-down of a calandria tank. In the design of the test facility, a scaling law was developed in such a way to consider the thermal-hydraulic characteristics of a CANDU-6 moderator. The proposed scaling law takes into consideration of the energy conservation, the dynamic similitude such as dimensionless numbers, Archimedes number (Ar) and Reynolds number (Re), and thermal-hydraulic properties similitude. Using this proposed scaling law, the thermal-hydraulic scaling analyses of similar test facilities such as the SPEL (1/10 scale) and the STERN (1/4 scale), have been identified. As a result, in the case of the SPEL, while the energy conservation is well defined, the similarities of Ar and the heat density are not well considered. As for the similarity of the STERN, while both the energy conservation and the characteristics of Ar are well defined, the heat density is not. In the meanwhile, the HU-KINS test facility with 1/8 length scaled-down is well similitude in compliance with all similarities of the energy conservation, the fluid dynamics and thermal-hydraulic properties. To verify the adequacy of the similarities in terms of thermal-hydraulics, a computational fluid dynamic (CFD) analysis has been conducted using the CFX-5 code. As the results of the CFD analyses, the predicted flow patterns and variation of axial properties inside the calandria tank are well consistant with those of previous studies performed with FLUENT and this implies that the present scaling method is acceptable.

압력선회형 인젝터를 이용한 젤 추진제의 분열특성 연구 (Study on Breakup Characteristics of Gel Propellant Using Pressure Swirl Injector)

  • 조장희;이동희;김설희;이동근;문희장
    • 한국추진공학회지
    • /
    • 제25권5호
    • /
    • pp.10-17
    • /
    • 2021
  • 본 연구에서는 압력 선회형 인젝터를 이용한 모사 젤 추진제의 분무실험을 수행하여 젤화제 첨가량에 따른 분무특성을 파악하였다. 실험을 통해 인젝터 내부의 공기층이 노즐에 국부적으로 형성되며 점차 와류실까지 확장되는 것을 확인하였으며 뉴턴 유체의 공기층 발달과정과 형상학적으로 유사한 경향성을 보였다. 분무형상은 4개의 유형으로 구분하였으며, 이를 공기층의 형성과정과 연관하여 형상학적으로 분석하였다. 분무형상을 바탕으로 일반화된 레이놀즈수, 웨버수 및 오네소지수와 같은 무차원 수에 따라 분열영역을 구분하였다. 추후 분무성능에 영향을 미치는 와류실 형상변화에 따른 공기층의 형상과 안정성, 이에 따른 분무특성에 관한 연구가 추가로 필요할 것으로 사료된다.