Design of the 1/8 Scaled HU-KINS Based on the Scaling Laws for the Experimental Investigation of Thermal-Hydraulic Effect of CANDU-6 Moderator

CANDU-6 원자로 감속재 열수력 개별영향실험을 위한 축소화 기법에 따른 1/8 축소형 HU-KINS 설계

  • 이재영 (한동대학교 기계제어공학부) ;
  • 김만웅 (한국원자력안전기술원) ;
  • 김남석 (한동대학교 일반대학원 기계제어공학부)
  • Published : 2006.09.01

Abstract

To investigate the moderator coolability for CANDU-6 reactors, a test facility (HU-KINS) has been manufactured as a 1/8 scaled-down of a calandria tank. In the design of the test facility, a scaling law was developed in such a way to consider the thermal-hydraulic characteristics of a CANDU-6 moderator. The proposed scaling law takes into consideration of the energy conservation, the dynamic similitude such as dimensionless numbers, Archimedes number (Ar) and Reynolds number (Re), and thermal-hydraulic properties similitude. Using this proposed scaling law, the thermal-hydraulic scaling analyses of similar test facilities such as the SPEL (1/10 scale) and the STERN (1/4 scale), have been identified. As a result, in the case of the SPEL, while the energy conservation is well defined, the similarities of Ar and the heat density are not well considered. As for the similarity of the STERN, while both the energy conservation and the characteristics of Ar are well defined, the heat density is not. In the meanwhile, the HU-KINS test facility with 1/8 length scaled-down is well similitude in compliance with all similarities of the energy conservation, the fluid dynamics and thermal-hydraulic properties. To verify the adequacy of the similarities in terms of thermal-hydraulics, a computational fluid dynamic (CFD) analysis has been conducted using the CFX-5 code. As the results of the CFD analyses, the predicted flow patterns and variation of axial properties inside the calandria tank are well consistant with those of previous studies performed with FLUENT and this implies that the present scaling method is acceptable.

Keywords

References

  1. Koroyannakis, D., Hepworth, R.D. and Hendrie, G., 1983, 'An Experimental Study of Combined Natural and Forced Convection Flow in a Cylindrical Tank,' TDVI-382, AECL
  2. Fortman, R.A. and Hadaller, G.I., 1990, 'Moderator Temperature Distribution Experiments, Modified Inlet Port Tests: Results and Comparison,' COG R&D Commercial, Nov
  3. Hadaller, G. I. and Fortman, R. A., 1990, 'Moderator Temperature Distribution Experiments, Phase 1: Unobstructed and Obstructed; Adiabatic and Diabatic with Resistance Heating,' COG R&D Commercial, Mach
  4. Hadaller, G. I. and Fortman, R. A., 1990, 'Moderator Temperature Distribution Experiments, Phase 2: Obstructed Diabatic Tests with Electrolytic and Resistance Heating,' COG R&D Commercial, June
  5. Lee, J.Y. and No, H.C., 1990, 'Dynamic Scaling Method for Testing the Performance of the Water Level Controller of Nuclear Steam Generators,' Nucelar Engineering and Design, Vol. 122, pp. 313-327 https://doi.org/10.1016/0029-5493(90)90215-J
  6. Ishii, M. and Revankar, S.T., 1994, 'Scientific Design of Purdue University Multi-Dimensional Integral Test Assembly (PUMA) for GE SBWR,' NUREG/CR-6390
  7. Zhukauskas, A., 1972, 'Heat Transfer from Tubes in Cross Flow,' in J.P.Hartnett and T.F.Irvine, Jr., Eds., Advances in Heat Transfer, Vol. 8, Academic Press, New York
  8. Yoon, C., Rhee, B.W. and Min, B.J., 2002, 'Validation of a CFD Analysis Model for Predicting CANDU-6 Moderator Temperature Against SPEL Experiments,' Proceedings of ICONE10, April 14-18, Virginia, USA
  9. Yu, S.O. and Kim, M.W., 2002, 'Assesment of Moderator Integrity Using Realistic Model and Parametric Studies on Thermal-Hydraulic Characteristics in SPEL,' Proceedings of the KNS Fall Meeting
  10. Jung, Y.S., Lee, J.Y. and Kim, M.W., 2004, 'The Transition Criteria of Circulating Flow Pattern of Moderator in the Calandria Tank of CANDU Nulcear Power Plant,' N6P141, Proceedings of NUTHOS-6: 6th International Topical Meeting on Nucelar Reactor Thermal Hydraulics, Operation and Safety, October 4-8(2004)Nara, Japan