• 제목/요약/키워드: cyber disaster management

Search Result 42, Processing Time 0.189 seconds

A Study on the Improvement of Means of Egress Based on NFPA 101 (NFPA 101 피난 안정성 평가에 기초한 피난 규정 개선 방향 연구)

  • Kyeung-Ho Kang;Suck-Hwan Joung
    • Journal of the Korea Safety Management & Science
    • /
    • v.25 no.1
    • /
    • pp.31-38
    • /
    • 2023
  • The object of this study is to evaluate whether the means of egress of Jechon Sports Center and Miryang Sejong Hospital, where massive fire human casualties occurred in 2017 and 2018 respectively, comply with NFPA 101(Life Safety Code), and to suggest the need for supplementation of domestic means of egress regulations. The study evaluated the number and arrangement of the means of egress, travel distance, common path of travel, dead end and discharge from exit for each building by applying the means of egress regulations of NFPA 101. As a result of the evaluation through NFPA 101, the travel distance was appropriate, but some of the other items except for the travel distance did not meet NFPA 101. The regulations that need to be supplemented are 1)occupant load calculation 2)egress capacity calculation 3)continuous concept of means of egress 4)concept of common path of travel. It is especially necessary to revise the requirement for fire door of the evacuation floor(normal 1st floor) of the stairwell in case of below the five story building.

Measures to Increase Evacuation Safety through Performance-Based Design of Escape Room Cafes (방탈출카페의 성능위주설계에 의한 피난안전성 확대 방안)

  • Hong-Sang Lee;Jai Young Lee;Ha-Sung Kong
    • Journal of the Korea Safety Management & Science
    • /
    • v.25 no.4
    • /
    • pp.95-104
    • /
    • 2023
  • The purpose of this study is to propose measures to increase evacuation safety by calculating the habitable time using a fire and evacuation simulation program for the Room-escape cafe currently in operation, and comparing and analyzing it with the evacuation required time. Assuming a fire due to overheating of electric heaters in use in front of the warehouse, the habitable time was calculated through fire simulation, and the occupant's evacuation time calculated through evacuation simulation according installation of safety facilities, etc. was compared and analyzed with the habitable time. In the case of escape room cafes with safety facilities installed, evacuation safety was satisfied, but in escape room cafes without safety facilities, the evacuation safety was not secure. As a result of analyzing evacuation safety for each scenario based on the ASET analyzed in the fire simulation, it was found that in scenario 1, evacuation safety was secured and everyone successfully evacuated, while in scenario 2, no one succeeded in evacuation. These results can be said to confirm that the installation of safety facilities is very important in business establishments such as escape room cafes, which become enclosed structures when games are started.

A Study on the Safety Improvement of Carbon Black Manufacturing Process (카본블랙 제조공정의 안전성 향상에 관한 연구)

  • Joo, Jong-Yul;Jeong Phil-Hoon;Sung-Eun, Lee
    • Journal of the Korea Safety Management & Science
    • /
    • v.25 no.4
    • /
    • pp.153-161
    • /
    • 2023
  • Carbon black is a material in the form of fine black powder obtained by incomplete combustion or pyrolysis of hydrocarbons, and is composed of 90-99% carbon, and the rest is composed of hydrogen and oxygen. In the event of an emergency during the manufacture of carbon black, the generated tail gas should be safely discharged through an emergency line to prevent fire, explosion, and environmental pollution accidents caused by the tail gas. If the pressure continues to rise, the pressure control valve shall operate and the rupture plate shall be ruptured sequentially and the tail gas shall be discharged to the vent stack through the emergency line. As an emergency emission system, even if some untreated substances in the tail gas are released into the atmosphere, they are lighter than air, so it is safe to discharge them to a safe place through the Vent Stack. If the gas pressure is rising or worse, it is discharged from the Vent Stackine, and discharging fuel.

The Introductin of the Special Act on Port Safety in South Korea: First-year Results and Future Tasks (「항만안전특별법」시행 1년의 성과와 과제)

  • Miju Kim;Seokhwan Kim
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.34 no.1
    • /
    • pp.26-34
    • /
    • 2024
  • Objectives: The successful implementation of the Port Safety Special Act is a very important matter. Now that one year has passed since its introduction, this study aims to review the achievements so far and identify future tasks. Methods: The provisions of the Special Act on Port Safety were analyzed and the latest literature related to port safety management was reviewed. In addition, an in-depth interview was conducted with a business owner. Results: The achievements over the past year are as follows. As business operators took greater responsibility for safety management, blind spots in safety were resolved to an extent. Specialized training for the port unloading industry was provided, and a safety management system was established for unloading docks. In addition, the Ministry of Oceans and Fisheries was able to intervene in the prevention of safety accidents at ports through the deployment of port safety inspectors. In 2022, the port industry accident frequency and death rate declined compared to the previous year. Conclusions: The "Port Safety Special Act" has become relatively well established in the port industry over the past year. However, since the Serious Disaster Punishment Act was implemented in January of the same year, there is a limit on determining what is necessarily the effect of the Special Act. Future tasks include unifying contracts centered on cargo handling companies, supporting safety management costs, increasing the number of port safety inspectors, producing reliable port disaster statistics, and cooperating between the Ministry of Oceans and Fisheries and the Ministry of Employment and Labor.

A Study on the Analysis and Countermeasures of Industrial Accident Deaths of Foreign Workers in the Manufacturing Industry (산업재해로 인한 외국인근로자의 제조업 사망사고 실태분석 및 대응방안에 관한 연구)

  • Jung-Duck Kim;Young-Soo Yu;Beom-Suk Go;Won-Baek Yang
    • Journal of the Korea Safety Management & Science
    • /
    • v.25 no.2
    • /
    • pp.39-48
    • /
    • 2023
  • Recently, the crisis of demographic extinction is rising in Korea more than any other country, and it is difficult for industrial sites to maintain without 'foreign workers'. Industrial accidents and accident deaths of foreign workers account for 7.6% and 12.3% of the total, through an in-depth analysis of fatal accidents in the manufacturing industry, differences and similarities between fatal accidents of foreign workers and all fatal accidents were confirmed in terms of occurrence type, workplace size, length of service, employment type, etc. In this study, customized countermeasures were found.

Study on the Evaluation of Radiant Heat Effects of Oil Storage Tank Fires Due to Environmental Conditions (환경조건에 따른 유류저장탱크 화재의 복사열 영향 평가 연구)

  • Lee, Jeomdong;Ryu, Juyeol;Park, Seowon;Yoon, Myong-O;Lee, Changwoo
    • Fire Science and Engineering
    • /
    • v.34 no.1
    • /
    • pp.72-78
    • /
    • 2020
  • In this paper, the risk of damages to humans and properties due to fire explosions in gasoline storage tanks is identified, and the effects of radiant heat on adjacent tanks are evaluated to present the necessary area to secure safety. A simulation was conducted to evaluate the effect of radiant heat (Maximum emission) on adjacent tanks in an oil storage tank fire due to environmental conditions (Wind speed and temperature) in the Northern Gyeonggi Province. The result indicated that the radiant heat released in the fire of an oil storage tank was increased by approximately 1.9 times by the maximum wind speed and the difference occurred in the range of 700~800 kW by the maximum temperature. If a storage tank fire occurs, securing approximately 34.4 m of holding area is necessary. In the future, evaluating the radiant heat emitted by the fire of gasoline storage tanks will be required by applying various environmental conditions, and through this, research on specific and quantitative holding area is required.

A Study on the Convergence of Monitoring and Control System with Geographic Information System (지리정보시스템과 관제시스템의 융합에 관한 연구)

  • Seo, Tae-Woong;Kim, Chang-Soo;Lee, Jae-Sung;Lee, Cheol-Won
    • Journal of Korea Multimedia Society
    • /
    • v.14 no.5
    • /
    • pp.703-709
    • /
    • 2011
  • State-based infrastructure on IT-based network are prone to numerous cyber attack including subsequent hacking and internet infringement. These acts of terrorism are increasing because of the expanding IT convergence technology. Recently, the trend on cyber security monitoring and control researches focus on combining the general idea of security monitoring and control along with IT field and other control systems. This convergence trend has been increasing in both the use and importance. This research analyzes the state-based infrastructure monitoring and control system, its vulnerability as well as its improvement by incorporating the cyber convergence systems to existing systems. The subject of this research is for extensive use of CCTV systems which is expanded for 'CCTV Monitoring and Control Field' as well as 'Traffic Monitoring and Control Field' operated by 'Intelligent Traffic Information System' and Disaster Management Area which is studied in various fields. Eventually, the objective of the paper is to solve these issues, to apply related systems and to suggest improvement on the convergence system.

A Study on the Improvement of Personal Information Protection in Small and Medium-sized Medical Institutions (중소형 의료기관의 개인정보 보안실태 및 개선방안)

  • Shin, Min ji;Lee, Chang Moo;Cho, Sung Phil
    • Convergence Security Journal
    • /
    • v.19 no.4
    • /
    • pp.123-132
    • /
    • 2019
  • Rapid developments of IT technology has been creating new security threats. There have been more attacks to get patients' sensitive personal information, targeting medical institutions that are relatively insufficient to prevent and defend against such attacks. Although the government has required senior general hospitals to get the ISMS certification since 2016, such a requirement has been burdensome for small and medium-sized medical institutions. Therefore, this study was designed to draw measures to identify and improve the privacy status of the medical institution by dividing it into management, physical and cyber areas for small and medium-sized medical institutions. The results of this study showed that the government should provide financial support and managerial supervision for the improvement of personal information protection of small and medium-sized medical institutions. They also suggested that the government should also provide medical security specialists, continuous medical security education, disaster planning, reduction of medical information management regulations not suitable for small and medium sized institutions.

A Study on the Improvement of Field Activity for Firemen in Sandwich Panel Warehouse (샌드위치패널 창고 소방대원 현장활동 대응력 제고 방안)

  • An, Byung-Kug;Kim, Woon-Hyung;Yang, So-Jin;Ham, En-Gu
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.3
    • /
    • pp.421-429
    • /
    • 2020
  • Purpose: The purpose of this study is to present step-by-step countermeasures to prevent fires in sandwich panel warehouses and to enhance on-site fire response capabilities. Method: Interviews of firefighters related to fire sites, advice from fire experts, and experiments on protection performance were conducted to draw up measures for each element to strengthen on-site response capabilities. Result: The fire safety management checklist for warehouse fire safety managers and the installation standards for wall protection of sandwich panel warehouses are presented. In addition, Standard Operational Procedures(SOP) for fire application of sandwich panel warehouses were established for firefighters on-site. Conclusion: Through this study, step-by-step fire safety measures were established for preventing, protecting and suppressing fires in sandwich panel warehouses.

A Study on the Earthquake Safety Assessment of Energy Storage Facilities According to Climate Change (기후변화에 따른 에너지 저장시설 지진 안전성평가에 관한 연구)

  • Ham, Eun-Gu;Lee, Sung-Il
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.2
    • /
    • pp.226-235
    • /
    • 2021
  • Purpose: The risk assessment for earthquakes was conducted in accordance with the current design standard (KBC2016) for the Coalescer facility, which is a major facility of energy storage facilities. Method: The risk assessment for earthquakes was conducted in accordance with the current design standard (KBC2016) for the Coalescer facility, which is a major facility of energy storage facilities. Result: In this study, by statically loading earthquake loads and evaluating the level of collapse prevention of special-class structures, facility managers can easily recognize and evaluate the risk level, and this analysis result can be applied to future facility risk management. Earthquake analysis was performed so that. Conclusion: As a result of analyzing the Coalescer facility according to the current design standard KBC2016, the stress ratio of the main supporting members was found to be up to 4.7%. Therefore, the members supporting Coalescer were interpreted as being safe against earthquakes with a reproducibility period of 2400 years that may occur in Korea.