• 제목/요약/키워드: contamination performance

검색결과 363건 처리시간 0.026초

전력설비에 대한 내오손특성 평가설비 구축 (Construction of the evaluating facilities against contamination characteristic for power installation)

  • 이정기;김민규;정주영;김익수;문인욱;강영식;성문주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 C
    • /
    • pp.1851-1853
    • /
    • 2004
  • The important consideration in laboratory designing and construction of the artificial pollution testing facilities including 300kV, 1800kVA AC test system, which enable to test and evaluate the UHV dielectric performance of power insulators up to transmission class, has been dealt in this paper. To evaluate the performance characteristics against contamination for various power installation, especially for the insulators and kinds of bushings, brief investigation and an analysis of test objects and related international codes and standards have been conducted. With the special consideration concerning other matters in designing of these testing facilities have been described with the fixed ratings and references.

  • PDF

RTV 실리콘 고무 코팅재의 표면전하 축적이 발수성에 미치는 영향 (Effect of Accumulated charges on Surface Hydrophobicity of RTV Silicone Rubber)

  • 연복희;허창수;조한구
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.597-600
    • /
    • 2001
  • In this paper, we evaluated the effect of accumulated charges on hydrophobicity of room temperature vulcanized(RTV) silicone rubber, which could improve the contamination performance of porcelain insulators, with uv radiation time. Outdoor insulating material could be charged by the corona discharge on field intensified area of insulator and discharge between the water drops. In addition, we performed the accelerated uv radiation on samples and investigated the change of charging decay with time. In this results, it is found that silica-like structure on the surface of RTV silicone rubber was formed by uv treatments and this layer have the characteristic of retaining the charges on surface for a long time. These charges have effects on its hydrophobicity and so adversely effects on contamination performance. Based on our results, we discussed the other degradation mechanism with well known ones.

  • PDF

Alternating-Projection-Based Channel Estimation for Multicell Massive MIMO Systems

  • Chen, Yi Liang;Ran, Rong;Oh, Hayoung
    • Journal of information and communication convergence engineering
    • /
    • 제16권1호
    • /
    • pp.17-22
    • /
    • 2018
  • In massive multiple-input multiple-output (MIMO) systems, linear channel estimation algorithms are widely applied owing to their simple structures. However, they may cause pilot contamination, which affects the subsequent data detection performance. Therefore, herein, for an uplink multicell massive multiuser MIMO system, we consider using an alternating projection (AP) for channel estimation to eliminate the effect of pilot contamination and improve the performance of data detection in terms of the bit error rates as well. Even though the AP is nonlinear, it iteratively searches the best solution in only one dimension, and the computational complexity is thus modest. We have analyzed the mean square error with respect to the signal-to-interference ratios for both the cooperative and non-cooperative multicell scenarios. From the simulation results, we observed that the channel estimation results via the AP benefit the following signal detection more than that via the least squares for both the cooperative and non-cooperative multicell scenarios.

전력기기 내오손특성 평가기반 구축 (Construction of the infrastructure for evaluating characteristic against contamination for power installation)

  • 이정기;김민규;문인욱;정주영;김익수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 C
    • /
    • pp.1513-1514
    • /
    • 2006
  • In this paper, there have been brief review about the important consideration in laboratory planning and construction of the artificial pollution testing facilities including 300 kV, 1800 kVA AC test system, which enable to lest and evaluate the UHV dielectric performance of power insulators up to transmission class. Also it is described simply about its trial running of the whole test system. To evaluate the performance characteristics against contamination for various power installation, especially for the insulators and kinds of bushings, brief investigation and an analysis of test objects and related international codes and standards have been conducted.

  • PDF

지지애자의 표면오염 모니터링 기술 및 장치 (Monitoring Technique and Device of Surface Contamination for Line-Post Insulator)

  • 길경석;박대원;정광석;김선재;서동환
    • 한국전기전자재료학회논문지
    • /
    • 제23권5호
    • /
    • pp.413-417
    • /
    • 2010
  • Line to ground faults by deterioration of insulators has frequently occurred in power system, and the main cause is surface contamination of the insulators. The contamination of insulator is analyzed by monitoring the surface leakage current flowing them. The suspension insulator is monitored by installation of a zero-phase current sensor(ZCT), but the line-post insulator is impossible to apply the same method because of its large diameter structure. This paper proposed a detection method of surface leakage current for a line-post insulator, and it can easily be applied to new and/or built insulators. The leakage current is indirectly calculated from the potential difference between the metal electrode attached on the surface of insulator and the ground connector. To evaluate the performance of the proposed method, the leakage current is compared as a function of contamination condition controlled by the density of NaCl solution. The leakage current is proportioned to the density of NaCl solution, and the voltage detected by the electrode showed the same trend. From the experimental results, we designed and fabricated a monitoring device which is composed of a detection electrode, signal converter, microprocessor, and ZigBee, and its measurement range is $10{\mu}A{\sim}5mA$.

배관 내부 방사능 오염도 측정용 ZnS(Ag)/BC-408 phoswich 검출기 개발 (Development of the ZnS(Ag)/BC-408 phoswich detector for monitoring radioactive contamination inside pipes)

  • 김계홍;박찬희;정종헌;이근우;서범경
    • Journal of Radiation Protection and Research
    • /
    • 제31권3호
    • /
    • pp.123-128
    • /
    • 2006
  • 원자력 시설의 해체 시 발생되는 다양한 종류의 폐기물 중에서 배관 내부의 알파/베타선 오염 특성을 직접 평가하기 위해서는 소형의 방사선 검출 시스템이 요구된다. 본 연구에서는 배관 내부의 방사능 오염도를 직접 측정할 수 있는 장비 개발의 일환으로서 기존의 phoswich 검출기와 그 형태가 다른 ZnS(Ag)/플라스틱섬광체 조합의 알파/베타선 동시측정용 phoswich 검출기를 고안하였으며 섬광체 크기 및 검출 시스템의 최적 요건을 실험적으로 확인하고 알파/베타선 신호 분리도를 평가하였다. 그 결과 배관 내부의 오염도 측정에 적합한 phoswich 검출기의 최적 요건 및 배관 내부의 적용 가능성을 확인하였다.

섬유소재의 미세먼지 오염도 평가 방법 개발에 관한 연구 (Method to Evaluate Fabric Contamination Due to Fine Dust)

  • 황소영;권진경;김영실;최은진;김다진;김민;육세진
    • 한국기계가공학회지
    • /
    • 제20권11호
    • /
    • pp.86-91
    • /
    • 2021
  • Recently, functional clothes that can reduce deposition and/or penetration of fine dust have been developed. However, there are no methods to quantitatively evaluate the performance of these clothes. In this study, we developed a method to contaminate a fabric using fine dust and established an approach to quantitatively assess the degree of particle contamination on the fabric surface. Silicate powder was chosen as the particle to simulate fine dust because silicate particles are fluorescent under UV light; therefore, they can be distinguished from any color of non-fluorescent fabric surface. A camera with a high-resolution lens system was used to scan the surface of the contaminated fabric surface, and the degree of particle contamination of the fabric surface was analyzed in terms of the pixels corresponding to the area of the fabric surface contaminated by silicate particles. Finished or unfinished nylon fabrics as well as cotton fabrics were contaminated with silicate particles, and their surfaces were scanned using the established camera. The proposed assessment method was found to be useful for quantitatively comparing the degree of particle contamination of the fabrics.

귀리, 수수, 율무, 기장의 수확기에 발생하는 Fusarium 곰팡이독소 오염도 조사 (Survey on Fusarium Mycotoxin Contamination in Oat, Sorghum, Adlay, and Proso Millet during the Harvest Season in Korea)

  • 이미정;위치도;함현희;최정혜;백지선;임수빈;이데레사;김점순;장자영
    • 한국식품위생안전성학회지
    • /
    • 제35권1호
    • /
    • pp.13-22
    • /
    • 2020
  • 잡곡의 Fusarium 곰팡이독소의 오염 조사를 위해, 총 244개 잡곡시료(귀리, 수수, 율무, 기장)를 수확기 포장에서 2017년과 2018년에 수집하였다. 데옥시니발레놀(DON), 니발레놀(NIV), 제랄레논(ZEA)은 면역친화컬럼법과 UPLC를 이용하여 분석하였으며, 푸모니신(FUM)은 QuEChERS 방법과 LC-MS를 이용하여 분석하였다. 잡곡 시료 중 귀리의 NIV 오염수준은 120.0-3277.0 mg/kg로 다른 잡곡에 비해 가장 높았다. 율무에서는 DON이 최대 730.0 ㎍/kg 검출되었다. 기장의 NIV과 ZEA의 오염빈도는 각각 61.5%와 57.9%로 높았으나 평균 오염량은 각각 75.6 ㎍/kg과 21.5 ㎍/kg로 안전한 수준이었다. 잡곡 시료 중 수수는 DON, ZEA, FUM의 오염빈도가 가장 높았으며, 2 종 이상의 Fusarium 독소 중복 오염률이 70.0%로 잡곡 평균 29.9%에 비해 높았다. 잡곡 재배포장에서 Fusarium 독소오염을 안전하게 관리하기 위하여 독소 발생 모니터링과 함께 오염예방기술 개발 연구가 수행되어야 할 필요가 있다.

공기 중 톨루엔에 의한 고분자전해질연료전지의 성능감소 (Decrease of PEMFC Performance by Toluene in Air)

  • 이호;송진훈;김기중;김세훈;안병기;임태원;박권필
    • Korean Chemical Engineering Research
    • /
    • 제49권1호
    • /
    • pp.15-20
    • /
    • 2011
  • 고분자전해질 연료전지에 유입되는 공기가 톨루엔에 오염되었을 때 전지 성능에 미치는 영향을 여러 톨루엔 농도와 운전 조건에서 연구하였다. 그리고 청정한 공기에 의한 전지 성능 회복과 활성탄 흡착에 의한 공기 중 톨루엔의 제거에 대해서도 연구하였다. 본 연구에서 실험한 톨루엔의 농도 범위는 0.1~5.0 ppm이었고 전지 성능감소와 회복은 일정전류에서 전압변화 측정법과 전기화학적 임피던스 측정법(EIS)에 의해 측정하였다. KOH 첨착활성탄의 톨루엔 흡착용량은 등온흡착곡선으로 구했다. 톨루엔 농도가 증가할수록, 전류밀도가 증가할수록, 공기유량이 증가할수록 톨루엔 오염에 의한 성능감소가 심했다. 그러나 상대습도가 증가할수록 톨루엔 오염에 의한 성능감소는 작았다. 가습된 청정 공기 중의 산소와 수분에 의한 톨루엔의 산화에 의해 전지의 성능이 회복되었다. 톨루엔의 백금 표면 흡착에 의한 전하 전달 저항 증가가 전지 성능을 주로 감소시킴을 EIS가 보였다. 첨착활성탄의 톨루엔 흡착 용량은 KOH 첨착량이 증가할수록 감소하였다.