• Title/Summary/Keyword: concentration measure

Search Result 1,484, Processing Time 0.027 seconds

Studies on the Anti-bacterial, Anti-inflammatory and Anti-oxidant Effect of BPH (비피(鼻皮) 증류액의 항균, 소염, 항산화 작용에 대한 연구)

  • Kim, Ho-Seon;Lee, Young-Jong
    • The Korea Journal of Herbology
    • /
    • v.29 no.5
    • /
    • pp.45-53
    • /
    • 2014
  • Objectives : The purpose of the study is to test the antibacterial, anti-inflammatory and antioxidant effects of BPH, which is composed of Pini Densiflorae Nodi Lignum and Querci Acutissimae Fructus, Angelicae Gigantis Radix, Cnidii Rhizoma, Angelicae Dahuricae Radix, Angelicae Tenuissimae Radix. Method : Antibacterial and anti-inflammatory effects of BPH on Propionibacterium acnes, one of anaerobic bacteria species were evaluated by measuring the levels of 2,2-diphenyl-1-picrylhydrazyl (DPPH) elimination and lipid peroxidation. Result : When BPH was applied to CCD-986sk (Human normal fibroblast) to confirm the level of cytokine(tumor necrosis factor-alpha, interleukin-8), its level increased in proportion to that of BPH's concentration, which indicated dose-dependent relationship. Using the Disk diffusion to measure the bacterial growth inhibition zone varying BPH concentration, it was found that the antibacterial effect of BPH was less than that of erythromycin, the control group, but was higher than that of saline, and it increased with higher concentrations. In a liquid culture medium containing BPH, the growth rate of Propionibacterium acnes was decreased by more than 10% at 25% BPH. After adding P. acnes to THP-1 monocyte, and treated it with BPH, and measuring the concentration of TNF-a and IL-8, it was observed that the amount of TNF-alpha and IL-8 significantly decreased depending on the level of BPH concentration. The ability to eliminate DPPH increased with higher BPH concentration. The inhibition of lipid peroxidation was increased by BHT treatment in a dose-dependent manner. Conclusion : Using Propionibacterium acnes, an anaerobic bacteria, we confirmed that BPH has antibacterial, anti-inflammatory and antioxidant effects.

Anti-Inflammatory Effect of Anemarrhenae Rhizoma 80% Ethanol Extract in RAW 264.7 cells (RAW 264.7 세포에서 지모(知母) 80% 에탄올 추출물의 항염증 효과)

  • LEE, Young Keun;KIM, Cheong Taek;CHOI, Hak Joo
    • The Korea Journal of Herbology
    • /
    • v.32 no.3
    • /
    • pp.97-103
    • /
    • 2017
  • Objective : According to recent studies, Anemarrhenae Rhizoma has anti-inflammatory activities of DW extract, but it hasn't not yet conducted to evaluate inflammatory factors about 80% ethanol extract. Therefore, The aim of this study is to investigate the various effects of individual or combined 80% ethanol extract of Anemarrhenae Rhizoma on cell viability and various anti-inflammatory factors. Methods : Anemarrhenae Rhizoma extract was prepared with 80% ethanol. MTT assay, ELISA, and Luminex were performed in LPS-activated RAW 264.7 cell line to measure cytotoxicity, Nitric oxide (NO), cyclooxygenase-2 (COX-2), prostaglandin E2 ($PGE_2$), Leukotriene B4 ($LTB_4$), and cytokines ($IL-1{\beta}$, IL-6, and $TNF-{\alpha}$), respectively. Results : At concentration of $200{\mu}g/m{\ell}$ Anemarrhenae Rhizoma extract, cytotoxicity was observed in RAW 264.7 cells. However, at concentration less than $100{\mu}g/m{\ell}$ of Anemarrhenae Rhizoma, cytotoxicity was not observed in RAW 264.7 cells. All concentration of Anemarrhenae Rhizoma extract showed no difference of NO, and $IL-1{\beta}$level in RAW 264.7 cells compared with control group. In contrast, at concentration of $100{\mu}g/m{\ell}$ Anemarrhenae Rhizoma extract significantly inhibited LPS-induced production of COX-2, PGE2, and $LTB_4$ level in RAW 264.7 cells. In addition, the production of proinflammatory cytokines (IL-6, $TNF-{\alpha}$) in LPS-induced RAW 264.7 cells was significantly decreased at concentration of all or 10, and $100{\mu}g/m{\ell}$, respectively. Conclusion : These findings demonstrate that Anemarrhenae Rhizoma has inhibitory effect on inflammatory mediators in LPS-activated RAW 264.7 cells showing possible developed as a raw material for new therapeutics to ease the symptoms related with inflammatory.

An Experimental Study on Real Time CO Concentration Measurement of Combustion Gas in LPG/Air Flame Using TDLAS (TDLAS를 이용한 LPG/공기 화염 연소가스의 실시간 CO 농도 측정에 관한 연구)

  • So, Sunghyun;Park, Daegeun;Park, Jiyeon;Song, Aran;Jeong, Nakwon;Yoo, Miyeon;Hwang, Jungho;Lee, Changyeop
    • Clean Technology
    • /
    • v.25 no.4
    • /
    • pp.316-323
    • /
    • 2019
  • In order to enhance combustion efficiency and reduce atmosphere pollutants, it is essential to measure carbon monoxide (CO) concentration precisely in combustion exhaust. CO is the important gas species regarding pollutant emission and incomplete combustion because it can trade off with NOx and increase rapidly when incomplete combustion occurs. In the case of a steel annealing system, CO is generated intentionally to maintain the deoxidation atmosphere. However, it is difficult to measure the CO concentration in a combustion environment in real-time, because of unsteady combustion reactions and harsh environment. Tunable Diode Laser Absorption Spectroscopy (TDLAS), which is an optical measurement method, is highly attractive for measuring the concentration of certain gas species, temperature, velocity, and pressure in a combustion environment. TDLAS has several advantages such as sensitive, non-invasive, and fast response, and in-situ measurement capability. In this study, a combustion system is designed to control the equivalence ratio. Also, the combustion exhaust gases are produced in a Liquefied Petroleum Gas (LPG)/air flame. Measurement of CO concentration according to the change of equivalence ratio is confirmed through TDLAS method and compared with the simulation based on Voigt function. In order to measure the CO concentration without interference from other combustion products, a near-infrared laser at 4300.6 cm-1 was selected.

An Effective Block of Radioactive Gases for the Storage During the Synthesis of Radiopharmaceutical (방사성의약품 합성에서 발생하는 방사성기체의 효율적 차단)

  • Chi, Yong Gi;Kim, Dong Il;Kim, Si Hwal;Won, Moon Hee;Choe, Seong-Uk;Choi, Choon Ki;Seok, Jae Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.126-130
    • /
    • 2012
  • Purpose : Methode an effective block was investigated to deal with volatile radioactive gas, short lived radioactive waste generated as a result of the routinely produced radiopharmaceuticals FDG (2-deoxy-2-[$^{18}F$]fluoro-D-glucose) and compound with $^{11}C$. Materials and Methods : All components of the radiation stack monitoring and data management system for continuous radioactive gas detection in the air extract system purchase from fixed noble gas monitor of Berthold company. TEDLAR gas sampling bags purchase from the Dongbanghitech company. TEDLAR gas sampling bags (volume: 10 L) connected via paraflex or PTFE tubing and Teflon 3 way stopcock. When installing TEDLAR gas sampling bags in Hot cell on the inside and not radioactive gas concentrations were compared. According to whether the Hot cell inside a activated carbon filter installed, compare the difference in concentration of the radioactive gas $^{18}F$. Comparison of radiation emission concentration difference of module a FASTlab and TRACElab. Results : Activated carbon filter are installed in the Hot cell, a measure of the concentration of radioactive gas was 8 $Bq/m^3$. Without activated carbone filter in the hot cell was 300 $Bq/m^3$. Tedlar bag prior to installation of the radioactive gases a measure of the concentration was 3,500 $Bq/m^3$, $^{11}C$ synthesis of the measured concentration was 27,000 $Bq/m^3$. After installed a Tedlar bag and a measure concentration of the radioactive gases was 300 $Bq/m^3$ and $^{11}C$ synthesis was 1,000$Bq/m^3$. Conclusion : $^{11}C$ radioactive gas that was ejected out of the Hot cell, with the use of a Tedlar gas sampling bag stored inside. A compound of 11C is not absorbed onto activated carbon filter. But can block the release out by storing in a Tedlar gas sampling bag. We was able to reduce the radiation exposure of the worker by efficient radiation protection.

  • PDF

The Association of Lead Biomarkers of Lead Workers with Airborne Lead Concentration in Lead Industries (납 사업장의 공기 중 납 농도 및 납 노출 근로자들의 납 관련 생물학적 노출 지표의 관련성에 관한 조사)

  • Kim, Nam-Soo;Kim, Jin-Ho;Jang, Bong-Ki;Kim, Hwa-Sung;Ahn, Kyu-Dong;Lee, Byung-Kook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.17 no.1
    • /
    • pp.43-52
    • /
    • 2007
  • This study was designed to investigate the difference of airborne lead concentration by type of lead industries and type of lead exposure and to evaluate their association with lead biomarkers of lead workers in 11 lead using industries. Total of 182 lead workers (male: 167, female: 15) from 11 lead industries were participated for this study from March, 2004 to August, 2005. Airborne lead concentration were measured by representative personal sampling of workers in each unit workplace and applied same concentration value to the workers in the same unit workplace who did not measure their airborne lead with personal air sampling. Tibia lead, blood lead, zinc protoporphyrin in whole blood, ${\delta}$-aminolevulinic acid in urine, hemoglobin and hematocrit were selected as study variables of indices of lead exposure. Information about type of lead exposure (fume or non-fume other), age, work duration, smoking & drinking habit were also collected. Significant differences were seen in the means of zinc protoporphyrin, blood lead and tibia lead in lead workers by different airborne lead concentration in workplace. While blood lead and tibia lead in lead workers were significantly higher in secondary smelting than other types of lead industries, zinc protoporphyrin, ${\delta}$-aminolevulinic acid in urine and airborne lead concentration were significantly higher in litharge manufacturing. While the mean blood lead was significantly higher in the lead workers working in fume type unit workplace than those of non-fume lead workers, the mean airborne lead concentration of fume workers was significantly lower than non-fume lead workers. In the multiple regression analysis of airborne lead concentration and the type of lead exposure on tibia lead and lead exposure indices after adjustment of related covariates, airborne lead concentration was statistically significantly associated with blood lead and tibia lead, but the type of lead exposure was only associated with blood lead. To verify the causal association of airborne lead concentration on blood lead and tibia lead, further studies are needed.

An analysis of the concentration of radioactivity of natural radionuclides (238U, 232Th, 40K) and gamma-ray emitting artificial radionuclides(137Cs, 60Co) present in the drinking water of the city of Busan, Republic of Korea, and the calculated absorbed dose of the residents

  • Kim, Chang-Soo;Kim, Jung-Hoon
    • International Journal of Contents
    • /
    • v.8 no.2
    • /
    • pp.60-66
    • /
    • 2012
  • This study was designed to detect and measure the concentration of radioactivity of natural radionuclides ($^{238}U$, $^{232}Th$, $^{40}K$) and artificial radionuclides ($^{137}Cs$, $^{60}Co$) present in the drinking water of the city of Busan and surrounding areas in South Korea, and also to measure the absorbed dose of radiation caused by these elements in the residents so as to help better manage the risk that these radionuclides pose in the future. For the purposes of the study, a total of 42 samples of water were collected from three key water sources (19 samples of groundwater, 4 samples of tap water, and 19 samples of surface water) and their contents were analyzed for radioactivity concentration. The results revealed that two natural radionuclides, $^{238}U$ and $^{232}Th$, exist in the groundwater with an average concentration of radioactivity of 3.34 Bq/L and $8.28{\times}10^{-5}Bq/L$ respectively, while the surface water was found to contain the same two radionuclides with mean concentrations of 0.849 Bq/L and $1.103{\times}10^{-4}Bq/L$ respectively. In addition, of the 19 samples of the groundwater, $^{137}Cs$ was found in eight of them and $^{60}Co$ was detected in ten. Of the four samples of the tap water, $^{137}Cs$ was detected in all samples and $^{60}Co$ was detected in three. Both $^{137}Cs$ and $^{60}Co$ were detected in all 12 samples of surface water. As far as $^{40}K$ is concerned, this element was detected in three of the 19 groundwater samples, but was not detected in any surface or tap water sample. In addition, the absorbed dose of $^{238}U$ from the groundwater was $7.94{\times}10^{-8}Sv/y$, while the absorbed dose of $^{232}Th$ from the surface water was $9.33{\times}10^{-13}Sv/y$. The absorbed dose of $^{137}Cs$ from the tap water was $7.33{\times}10^{-5}Sv/y$, while the absorbed dose of $^{60}Co$ from the surface water was the highest at $4.23{\times}10^{-6}Sv/y$.

A development of new dielectric tracer test method for groundwater logging: laboratory soil column test (지하수 검층을 위한 새로운 유전율 추적자 시험법의 개발)

  • Kim Man-Il;Kim Hyoung-Soo;Jeong Gyo-Cheol
    • The Journal of Engineering Geology
    • /
    • v.14 no.3 s.40
    • /
    • pp.301-311
    • /
    • 2004
  • This study is suggested a new dielectric tracer test method to understand geological structure of porous media and groundwater flow to use the dielectric constant which is one of electrical special quality of various geological materials. To measure their parameters, tracer material is made an ethanol mixing liquid(EML) having a same specific gravity of water. Also, soil materials are prepared a dielectric tracer test using the FDR system that could measure dielectric constant for saturated standard sand and river sand layers which have different initial porosity. To compare with their results, we discussed with the concentration variation of saline water having a saline concentration $3\%$ which is general tracer material by using the electro multi-meter system in the laboratory or field test. In two tracer experiment results, EML tracer test could confirm definitely EML concentration variation from each saturated soil layer as standard and river sands. However, tracer test of saline water $3\%$ concentration could not confirm permeating movement of water by degree of salinity change because these are settled at lower part column in a whole column area continuously. These causes are that specific gravity of saline water is heavier than water. That is, it could know that deposition of saline water is composed of lower part of soil column continuously independently of the direction of water into saturated soil material.

Determination of Arsenic in Water by ICP-DRC/MS (ICP-DRC/MS를 이용한 수중의 비소 측정)

  • Jeong, Gwan-Jo;Kim, Dok-Chan;Park, Hyeon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.6
    • /
    • pp.620-625
    • /
    • 2006
  • In this investigation, an ICP-DRC/MS method to measure arsenic with ultra-trace concentration without any interference by the compounds such as $^{40}Ar^{35}Cl^+\;and\;^{40}Ca^{35}Cl^+$, which disturb the precise measurement of arsonic was described. Thus, the oxgen was introduced into the dynamic reaction cell as reaction gas and reacted with arsenic ion created in plasma gas, $AsO^+$ was formed and detected with m/z of 91 by ICP-MS. It resulted in better detection limit than the old method with m/z of 75($As^+$). The optimum condition for oxygen supply as the reaction gas was 0.5 mL/min. The analytical features of the method are as follows: detection limit of $0.02{\mu}g/L$, precision(RSD) of 3.4%, and recovery of 96%. Arsenic in the water samples from the tributary streams to the Han River and the main stream of Paldang were analyzed with this method to identify the characteristics in its distribution. The concentration of As ranged from 0.53 to $1.26{\mu}g/L$. We could measure As with very low concentration, less than $1.0{\mu}g/L$, with excellent reproducibility. The method developed is expected to be applied to analyze As of the samples from sea water, food, and domestic and industrial waste water which have high concentration of Cl and/or Ca.

Development of On-axis Raman Lidar System for Remotely Measuring Hydrogen Gas at Long Distance (원거리 수소 가스 원격 계측을 위한 On-axis 라만 라이다 장치 개발)

  • Choi, In Young;Baik, Sung Hoon;Lim, Jae Young;Cha, Jung Ho;Kim, Jin Ho
    • Korean Journal of Optics and Photonics
    • /
    • v.29 no.3
    • /
    • pp.119-125
    • /
    • 2018
  • Hydrogen gas is an important and promising energy resource that has no emissions of pollutants during power generation. However, hydrogen gas is very dangerous because it is colorless, odorless, highly flammable, and explosive at low concentration. Conventional techniques for hydrogen gas detection are very difficult for measuring the hydrogen gas distribution at long distances, because they sample the gas to measure its concentration. Raman lidar is one of the techniques for remotely detecting hydrogen gas and measuring the range of the hydrogen gas distribution. A Raman lidar system with an on-axis optical receiver was developed to improve the range of hydrogen gas detection at long distance. To verify the accuracy and improvement in the range of detecting the hydrogen gas, experiments measuring the hydrogen gas concentration are carried out using the developed on-axis Raman lidar system and a gas chamber, to prevent explosion of the hydrogen gas. As a result, our developed on-axis Raman lidar system can measure a minimum hydrogen gas concentration of 0.66 volume percent at a distance of 50 m.

Carotenoid의 급여가 산란노계의 도체 착색에 미치는 영향

  • 나재천
    • Proceedings of the Korea Society of Poultry Science Conference
    • /
    • 2003.11a
    • /
    • pp.9-27
    • /
    • 2003
  • This study was performed to measure the effect of carotenoid polarity on absorption and Pigmentation in blood, muscle, and skin of laying hens. Carotenoids used in this study and Polarity were ${\beta}$-8-Apo-carotenoic acid ethyl ester(ACAEE) > astaxanthin > canthaxanthin > ${\beta}$-carotene. The chickens used in this study were 61∼78 weeks old ISA brown laying hens. Experiment #1 was designed to measure the effect of carotenoid level on the accumulation of carotenoids in carcass of laying hens after feeding for 6 weeks. D-carotene was accumulated in skin only at a detectable level when it was fed at 300 mg/kg feed. The skin was pigmented as yellow when it was measured by colorimeter. The concentration of ${\beta}$-carotene in blood was proportional to that in the feed. Pigmentation of muscle by 9-carotene was not effective. Canthaxanthin significantly increased redness of the skin(p<0.05). However, canthaxanthin did not pigment muscle. The level of canthaxanthin in the blood and skin increased as the concentration in feed increased. ACAEE at 200 and 300 mg/kg feed significantly increased yellowness of the skin(p<0.05). At all levels of ACAEE used($\geq$50 mg/kg feed) the b values of colorimeter increased. With increases in the contents of ACAEE, the concentration of ACAEE in the blood and skin increased. Compared to ${\beta}$-carotene, ACAEE and canthaxanthin were absorbed 9- and 3-fold more into the blood, respectively. The concentration of ACAEE and canthaxanthin in the skin was 1/10 of those in the blood. The lower were the concentrations of carotenoids in the feed, the higher were the absorption rates(from feed to blood and from blood to skin) The results indicated that the higher was the polarity of carotenoids, the more effective were the absorption and pigmentation. In experiment #2, the effect of carotenoid levels of feed on the accumulation of carotenoids in each body part of laying hens was determined. The colorimeter values for redness and yellowness significantly increased when canthaxanthin was fed at $\geq$50 mg/kg feed(p<0.05). Breast and thigh were not affected by feeding of canthaxanthin at the levels used. The L values of muscle but not the a and b values were significantly affected by feeding at $\geq$200 mg/kg feed for wings and breasts, respectively. The yellowness of skin and muscle significantly increased when ACAEE was fed at $\geq$ 100 and $\geq$ 200 mg/kg feed, respectively(p<0.05).

  • PDF