• Title/Summary/Keyword: complete system

Search Result 2,702, Processing Time 0.034 seconds

REMARK ON THE CONTROLLABILITY FOR SEMILINEAR EVOLUTION EQUATIONS

  • Jeong, Jin-Mun
    • East Asian mathematical journal
    • /
    • v.29 no.5
    • /
    • pp.481-489
    • /
    • 2013
  • In this paper we deal with approximate controllability for semilinear system in a Hilbert space. In order to obtain the controllability, we assume that the system of the generalized eigenspaces of the principal operator is complete in the state space, which has a simple form and can be applied to many examples. Because of its simple form, some examples of controllability of the systems governed by the semilinear equations will be given.

Angiographic Follow-up Result of Cerebral Aneurysms Treated with Coils Covered with Polyglycolic-Polylactic Acid Copolymer

  • Kim, In-Cheol;Chun, Young-Il;Park, Cheol-Wan;Park, Chan-Woo;Lee, Uhn
    • Journal of Korean Neurosurgical Society
    • /
    • v.39 no.4
    • /
    • pp.286-291
    • /
    • 2006
  • Objective : We evaluate the effect of the copolymer-coated coils on immediate occlusion of the aneurysm, preventing rupture, and decreasing compaction or re-growth. Methods : Thirty-five aneurysms treated between September 2003 and December 2004 using Matrix detachable coil were reviewed. Study population consisted of 12 men and 23 women ranging in age from 34 to 75 years[mean, 55.1 years]. Twenty-two aneurysms were ruptured and 23 aneurysms were located in the anterior circulation. Follow-up angiography was obtained in 16 patients after 6 months from the procedure. Results : Initial complete occlusion was achieved in 17 aneurysms[48.6%], and the others remained as a residual neck in 8 aneurysms[22.8%] and residual sac in 10 aneurysms[28.6%]. Among these incompletely occluded aneurysms, 7 aneurysms were performed follow-up angiography. And 6 of them converted into complete occlusion. In the other hands, among 17 aneurysms achieved complete occlusion initially, 9 aneurysms were performed follow-up angiography. Recurrence due to coil compaction occurred in one aneurysm and the others maintained complete occlusion. There was one mortality case due to thromboembolic complication. Conclusion : In spite of difficulty in achieving complete occlusion with Matrix coil system, there is no rupture or re-rupture during follow-up period. Follow-up angiography shows many conversions of residual sac into complete occlusion. Embolization using Matrix coil system is safe and effective, but the effects of PGLA copolymer need further investigation.

WalkON Suit: A Wearable Robot for Complete paraplegics (WalkON Suit: 하지 완전마비 장애인을 위한 웨어러블 로봇)

  • Choi, Jungsu;Na, Byeonghun;Jung, Pyeong-Gook;Rha, Dong-wook;Kong, Kyoungchul
    • The Journal of Korea Robotics Society
    • /
    • v.12 no.2
    • /
    • pp.116-123
    • /
    • 2017
  • Wearable robots are receiving great attention from the public, as well as researchers, because its motivation is to improve the quality of lives of people. Above all, complete paraplegic patients due to spinal cord injury (SCI) might be the most adequate target users of the wearable robots, because they definitely need physical assistance due to the complete loss of muscular strength and sensory functions. Furthermore, the medical care of complete paraplegics by using the wearable robots have significantly reduced the mortality rate and improved the life expectancy. The requirements of the wearable robot for complete paraplegics are actuation torque, locomotion speed, wearing sensation, robust gait stability, safety, and practicality (i.e., size, volume, weight, and energy efficiency). A WalkON Suit is the wearable robot that has satisfied the requirements of the wearable robot for complete paraplegics and participated in the powered exoskeleton race of Cybathlon 2016. In this paper, configuration of the WalkON Suit, human-machine interface, gait pattern, control algorithm, and evaluation results are introduced.

FINANCIAL SYSTEM: INNOVATIONS AND PRINCING OF RISKS

  • Melnikov, A.V.
    • Journal of the Korean Mathematical Society
    • /
    • v.38 no.5
    • /
    • pp.1031-1046
    • /
    • 2001
  • The paper studies the evolution of the financial markets and pays the basic attention to the role of financial innovations (derivative securities) in this process. A characterization of both complete and incomplete markets is given through an identification of the sets of contingent claims and terminal wealths of self-financing portfolios. the dynamics of the financial system is described as a movement of incomplete markets to a complete one when the volume of financial innovations is growing up and the spread tends to zero (the Merton financial innovation spiral). Namely in this context the paper deals with the problem of pricing risks in both field: finance and insurance.

  • PDF

Classification system for partial distal biceps tendon tears: a descriptive 3-Tesla magnetic resonance imaging study of tear morphology

  • Alex B Boyle;Simon BM MacLean
    • Clinics in Shoulder and Elbow
    • /
    • v.26 no.4
    • /
    • pp.366-372
    • /
    • 2023
  • Background: There is minimal literature on the morphology of partial distal biceps tendon (DBT) tears. We sought to investigate tear morphology by retrospectively reviewing 3-Tesla magnetic resonance imaging (3T MRI) scans of elbows with partial DBT tears and to propose a basic classification system. Methods: 3T MRI scans of elbows with partial DBT tears were retrospectively reviewed by two experienced observers. Basic demographic data were collected. Tear morphology was recorded including type, presence of retraction (>5 mm), and presence of discrete long-head and short-head tendons at the DBT insertion. Results: For analysis, 44 3T MRI scans of 44 elbows with partial DBT tears were included. There were 9 isolated long-head tears (20%), 13 isolated short-head tears (30%), 2 complete long-head tears with a partial short-head tear (5%), 5 complete short-head tears with a partial long-head tear (11%), and 15 peel-off tears (34%). Retraction was seen in 5 or 44 partial tears (11%), and 13 of the 44 DBTs were bifid tendons at the insertion (30%). Conclusions: Partial DBT tears can be classified into five sub-types: long-head isolated tears, short-head isolated tears, complete long-head tears with partial short-head involvement, complete short-head tears with partial long-head involvement, and peel-off tears. Classification of tears may have implications for operative and non-operative management. Level of evidence: III.

Construction Algorithm of Grassmann Space Parameters in Linear Output Feedback Systems

  • Kim Su-Woon
    • International Journal of Control, Automation, and Systems
    • /
    • v.3 no.3
    • /
    • pp.430-443
    • /
    • 2005
  • A general construction algorithm of the Grassmann space parameters in linear systems - so-called, the Plucker matrix, 'L' in m-input, p-output, n-th order static output feedback systems and the Plucker matrix, $'L^{aug}'$ in augmented (m+d)-input, (p+d)-output, (n+d)-th order static output feedback systems - is presented for numerical checking of necessary conditions of complete static and complete minimum d-th order dynamic output feedback pole-assignments, respectively, and also for discernment of deterministic computation condition of their pole-assignable real solutions. Through the construction of L, it is shown that certain generically pole-assignable strictly proper mp > n system is actually none pole-assignable over any (real and complex) output feedbacks, by intrinsic rank deficiency of some submatrix of L. And it is also concretely illustrated that this none pole-assignable mp > n system by static output feedback can be arbitrary pole-assignable system via minimum d-th order dynamic output feedback, which is constructed by deterministic computation under full­rank of some submatrix of $L^{aug}$.

Complete genome sequence of Flavobacteriaceae strain KCTC 52651 isolated from seawater recirculating aquaculture system (해수 순환여과양식시스템에서 분리된 Flavobacteriaceae 균주 KCTC 52651의 유전체 분석)

  • Kim, Young-Sam;Jeon, Young Jae;Kim, Kyoung-Ho
    • Korean Journal of Microbiology
    • /
    • v.55 no.2
    • /
    • pp.174-176
    • /
    • 2019
  • A novel bacterium, designated strain RR4-38 (= KCTC 52651 = DSM 108068), belonging to the family Flavobacteriaceae was isolated from a biofilter in the seawater recirculating aquaculture system in South Korea. A single complete genome contig which is 3,182,272 bp with 41.9% G+C content was generated using PacBio RS II platform. The genome includes 2,829 protein-coding genes, 6 rRNA genes, 38 tRNA genes, 4 non-coding RNA genes, and 9 pseudogenes. The results will provide insights for understanding microbial activity in the seawater recirculating aquaculture system.

Development of the Container Damage Inspection System (컨테이너 파손 검사장치의 개발)

  • Oh Jae Ho;Hong Seong Woo;Choi Gyu Jong;Kim Myong Ho;Ahn Doo Sung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.1
    • /
    • pp.82-88
    • /
    • 2005
  • The damage inspection of container surface is performed by the expert inspectors at the container terminal gate of harbor. In this paper, we substitute the expert's capability with the damage inspection system using the artificial intelligent control algorithm and vision system, so we can improve the work environment and effectively decrease the inspection time and cost. Firstly, using six CCD cameras attached to the terminal gate, whole container is partially captured according to eleven sensors aligned with the entering direction of container. Captured partial images are inspected by the fuzzy system which the expert's technology is embedded. Next, we compose partial images to be a complete container image through the correlation coefficient method. Complete container image is saved to solve future troublesome problems. In this paper, the effectiveness of the proposed system was verified through the field test.

A study on standardization & completion of transfer consultation record for patients transferred to emergency medical center (응급의료센터로 전원된 환자의 진료의뢰서 표준화 및 충실도에 관한 연구)

  • Yoou, Soonkyu;Kim, Kwang Hwan;Cho, Hae Kyung
    • The Korean Journal of Emergency Medical Services
    • /
    • v.5 no.1
    • /
    • pp.177-198
    • /
    • 2001
  • The purpose of this research which was conducted by surveying the transfer consultation records from 360 medical institutions such as general hospitals, hospitals, clinics to the Emergency Medical Center at E University Hospital for six months(Jan. 1, 2000 - Jun. 30, 2000) are to standardize & complete transfer consultation record of hospitals at the 1st & 2nd referral level and to give patients transferred emergency medical center medical information services on a better quality. The conclusions and suggestions from this study were summarized as follows; (1) Examing the distribution of the referral medical consultation(transfer) sheet type, surgery part local clinic sheet types were 34.4%, medical part local clinic sheet types were 26.7%, undifferentiated local clinic sheet types were 23.9% and hospital level sheet types were 15.0%. (2) The items of the transfer consultation records had been standardized more than 75% in the order of patient's name, date, doctor's name, diagnosis, patient's status, impressions. (3) That the degree of recording completion on these items is in the order of patient's name, date, diagnosis, impressions was revealed. (4) Because the standardization and the degree of recording completion are very low in the patient's gender, age, address, electronic recording system was needed for more perfect input of initial patient informations. (5) This standardizing & complete recording on examination and medication will prevent re-examination and abuse of medication for patients transferred emergency medical center. (6) EMT Transfer System should be fixed in all medical institute for the standardizing & complete recording on care period and departure time will give many emergency patients the proper treatments at the proper time. (7) It was revealed that developing new standardized transfer consultation record & using electronic recording system are needed. (8) The complete recording & Fast Track System were needed for higher rate of bed operation at emergency medical center and more hospital profit.

  • PDF

Rehabilitation of fully edentulous patient using Ceramill full denture system (FDS) (Ceramill full denture system을 이용한 무치악 환자의 양악 총의치 제작)

  • Lee, Younghoo;Kwon, Kung-Rock;Pae, Ahran;Noh, Kwantae;Paek, Janghyun;Hong, Seoung-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.3
    • /
    • pp.232-237
    • /
    • 2019
  • CAD/CAM technology has already been used in most areas of prosthetics. The range of CAD/CAM application in denture fabricating process has been gradually increasing since the CAD/CAM technology was introduced for the fabrication of complete dentures in 1994. This paper describes a technique that combines conventional and CAD/CAM technology for the fabrication of complete dentures: the master casts from a conventional impression techniques were scanned first, and the wax denture was fabricated using Amann Girrbach's Ceramill full denture system (fds). The purpose of this paper is to introduce the case in which making an esthetically and functionally satisfied denture in shorter time is possible with CAD/CAM technology.