• Title/Summary/Keyword: ceiling

Search Result 983, Processing Time 0.029 seconds

Environmental Survey to a Ventilation System on the Enclosed Farrowing-nursery Pig House in Winter (무창 분만ㆍ자돈사내에서 환기시스템별 혹한기 환경 조사)

  • 유용희;송준익;정종원;김태일;최희철;양창범;이영윤
    • Journal of Animal Environmental Science
    • /
    • v.10 no.1
    • /
    • pp.23-28
    • /
    • 2004
  • This study was conducted to improve a ventilation system on the enclosed farrowing-nursery pig house in Korean swine facilities. This survey ventilation system types four major structures. The first structure has planer slot inlet, where air comes in, and these are placed outside the wall under the eave. Then the air from the pig house flows out through the chimney outlet operated by an exhaust fan(V1). The second structure has an air input through the perforated ceiling inlet, then the air from the pig house flows out through the chimney outlet operated by an exhaust fan(V2). Through the circular duct inlet placed inside the juncture of the entry wall, air also comes in(third structure). Then, air from the pig house flows out through the chimney outlet operated by an exhaust fan(V3), Similarly, air comes in through the circular duct inlet placed inside the juncture of the entry wall, but air from the pig house flows out through the side wall by an exhaust fan(V4). Temperature, relative humidity, air velocity and ammonia concentration(NH$_3$) were measured in the interior farrowing-nursery pig house during winter. The results were as follows; Interior temperature at the pig house was not remarkably different in all ventilation systems. The V4 system had low area air velocity, and this was better than other systems. It also had a lower ammonia concentration than other systems. V3 and V4 systems had stable airflow patterns, better than other systems. Therefore, it is suggested that the V3 and V4 ventilation system be applied in the enclosed farrowing-nursery pig house in winter.

  • PDF

Assessment on Thermal Transmission Property of Wall Through a Scaled Model Test (축소모형 실험을 통한 벽체의 열관류 측정)

  • Chang, Yoon-Seong;Kim, Sejong;Shim, Kug-Bo;Lee, Sang-Joon;Han, Yeonjung;Park, Yonggun;Yeo, Hwanmyeong
    • Journal of the Korean Wood Science and Technology
    • /
    • v.43 no.6
    • /
    • pp.884-889
    • /
    • 2015
  • Appropriate evaluation of thermal insulation property of structural member and valid control of cooling/heating energy are important for improving building's energy efficiency. The typical heating system of house in Korea is the floor heating one. The radiation heating system is not only appropriate to climate and geographic conditions of Korea, but also advantageous to provide emotional comfort by the warm feeling of floor. Based on living conditions in Korea, scaled models of the wooden house and concrete house were designed. The ceiling was made of styrofoam insulation and the four sided walls and bottom were made of plywood and concrete, respectively. The floor was heated by heating film. Indoor vertical temperature distributions by floor heating system were measured by thermocouple, and surface temperatures on walls were measured by infrared thermography. Also, thermal insulation property of wooden wall was evaluated to build database for improving energy efficiency of wooden building. It is expected that collected data during tests of various types of floor and wall composition could be referenced for evaluating thermal environment of actual conditions of houses.

Analysis on Surface Collapse of the Road NATM Tunnel through the Weathered Rock (풍화대를 통과하는 도로 NATM 터널의 천단부 함몰에 대한 연구)

  • Shin, Eun-Chul;Yoo, Jai-Sung
    • Journal of the Korean Geosynthetics Society
    • /
    • v.15 no.2
    • /
    • pp.55-64
    • /
    • 2016
  • The construction of the road NATM tunnel, which undergoes the weathered zone of the mountain, was in process with the reinforcement methods such as the rock bolt, shotcrete depositing, and the multi step grout with large diameter steel pipe. The collapse from the ceiling, and on the ground surface area(sink hole), of which were measured to be 25m from the ground surface($V=12m(W){\times}14m(L){\times}5m(H)=840m^3$), as well as excessive displacements in the tunnel, had occurred. In order to execute the necessary reconstruction work, the causes of the surface collapses were inspected through the field investigation, in-situ tests, and numerical analysis. As a result, several proper solutions were suggested for both internal and external reinforcements for the tunnel. As a result of numerical analysis, the collapsed zone of the tunnel was reinforced up to 0.5D~1.0D laterally by the cement grouting on the ground surface, 0.5D longitudinally by the multi step grout with large diameter steel pipe in tunnel. With further reinforcement implemented by rebars in lining, the forward horizontal boring was executed to the rest of the tunnel to evaluate the overall status of the tunnel face. Appropriate reinforcement methods were provided if needed.

The study on enhanced micro climate of the oyster mushroom cultivation house with multi-layered shelves by using CFD analysis (CFD 분석에 의한 느타리버섯 재배사 환경균일성 향상 연구)

  • Lee, Sung-Hyoun;Yu, Byeong-Kee;Lee, Chan-Jung;Lim, Yeong-Taek
    • Journal of Mushroom
    • /
    • v.15 no.1
    • /
    • pp.14-20
    • /
    • 2017
  • The oyster mushroom cultivation house typically has multiple layers of growing shelves that cause the disturbance of air circulation inside the mushroom house. Due to this instability in the internal environment, growth distinction occurs according to the area of the growing shelves. It is known that minimal air circulation around the mushroom cap facilitates the metabolism of mushrooms and improves their quality. For the purpose of this study, a CFD analysis FLUENT R16 has been carried out to improve the internal environment uniformity of the oyster mushroom cultivation house. It is found that installing a section of the working passage towards the ceiling is to maintain the internal environment uniformity of the oyster mushroom cultivation house. When all the environment control equipment - including a unit cooler, an inlet fan, an outlet fan, an air circulation fan, and a humidifier - were operated simultaneously, the reported Root Mean Square (RMS) valuation the growing shelves were as follows: velocity 23.86%, temperature 6.08%, and humidity 2.72%. However, when only a unit cooler and an air circulation fan operated, improved RMS values on the growing shelves were reported as follows: velocity 23.54%, temperature 0.51%, and humidity 0.41%. Therefore, in order to maintain the internal environment uniformity of the mushroom cultivation house, it is essential to reduce the overall operating time of the inlet fan, outlet fan, and humidifier, while simultaneously appropriately manage the internal environment by using a unit cooler and an air circulation fan.

Constructability Analysis in Aged-Housing Remodeling Demolition Work for Maximizing Waste Recycling (폐기물 재활용성 향상을 위한 리모델링 철거공사의 시공성 평가 및 사례적용)

  • Chae, Seong-Hyun;Kim, Ki-Hyun;Cha, Hee-Sung;Kim, Kyung-Rai;Han, Ju-Yeoun
    • Korean Journal of Construction Engineering and Management
    • /
    • v.11 no.3
    • /
    • pp.13-22
    • /
    • 2010
  • From now on, the aged apartment or house is expected to increase rapidly. So, we have to build a process of remodeling and develop the new technique. Demolition work is needed for systematic plan and management. However, contractors of the remodeling project established a rough plan and did not consider recycling wastes, safety of workers and structural stability of building. Therefore, we need a step to develop a assessment system, verify and make specified. This paper evaluated how much improve on construction speed, work efficiency, intensity of work and influence with another process comparing the existing method with the new demolition method. The qualitative and quantitative assessment system are developed with these output. The case study was carried out experimental group and control group, based on developed assessment system, which have the same condition. The existing method was made up of 3 steps- 1)Demolish windows, doors and iron goods, 2)Demolish indoor and outdoor walls, 3)Drop the waste. The new demolition method was made up of 5 steps- 1)Demolish windows, doors and iron goods, 2)Demolish the ceiling and wall's finishing materials, 3)Demolish the floor's finishing materials, 4)Demolish indoor and outdoor walls, 5)Drop the waste. Work time, idle time, the character of a work unit are analyzed by mock-up test. This study's output is expected to establish a systematic process of new demolition method and based on the maximizing waste recycling work in our construction industry.

An Improvement on Wayfinding which considers Universal Design Concept (유니버설 디자인개념을 고려한 Wayfinding 개선 연구)

  • Lee, Kyung-A;Kim, Won-Pil
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.8
    • /
    • pp.423-432
    • /
    • 2016
  • Due to the increase in the number of transfer lines and ground level connections with mixed-use high-rise buildings, the Seoul Metro suffers from loaded signage fatigue because of the presence of too many signs. The purpose of this research is to propose ways of improving the wayfinding on the Seoul subway station by examining the signage and (applying the) universal design (UD) concept. A review of the literature explored five universal design components, viz. the accessibility, safety, equitability, perception, and aesthetics. The field investigation found that the ceiling and wall type and general information boards were high on the information hierarchy. The survey respondents merely perceived universal design concept, however, most needed principle. The IPA found that the signs should be appropriately laid out, spaced and located from the perspective of accessibility, and their unity and harmony were other aspects that could be improved while general information boards should include important landmarks outside. In conclusion, this study suggests that the universal design signage concept should be applied to every station and that specific stations should have a duly sign system.

Reliability and Validity of Korean Version of the Nurse-Patient Interaction Scale (한국판 간호사-환자 상호작용 측정도구의 신뢰도 및 타당도 검증)

  • Chang, Hee-Kyung;Lee, Ji-Yeon;Kim, Mi-Kyoung;Yang, Eun-Ok;Gil, Cho-Rong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.12
    • /
    • pp.747-757
    • /
    • 2019
  • This study examined the reliability and validity of the Korean version of the Nurse-Patient Interaction Scale (K-NPIS) for the elderly, at long-term care hospitals in Korea. The original NPIS was developed to identify important characteristics of elderly patient experiences regarding nurse-patient interactions in nursing homes. Totally, 202 hospitalized elderly patients at 4 long-term hospitals in Jinju-si, Suncheon-si, and Namwon-si, were enrolled in the study and completed the questionnaire. For internal consistency, Cronbach's α of K-NPIS was 0.96 after item analysis. K-NPIS was validated using the confirmatory factor analysis and content validity. The content validity score was more than 0.80, establishing the appropriateness and readiness of the tool through group discussions between clinical experts and elderly patients. The K-NPIS is a 10-point scale comprising 12 questions. K-NPIS scores between different residential groups were significantly different, and showed no ceiling or floor effect. The internal consistency reliability, construct validity, and discriminative validity of K-NPIS was adequate. However, criterion validity requires further examination. Our findings suggest that K-NPIS serves as an appropriate measure of nurse-patient interaction when applying the nursing care intervention for elderly.

An Asbestos Risk Assessment and Areal Distribution of Asbestos Containing Materials in Public Buildings (석면함유 공공 건축물의 위해성 평가 및 면적 분포 특성)

  • Song, Su-Jin;Jang, Bong-Ki;Jo, Bong-Hyun;Kim, Yeong-Ji;Heo, Eun-Hyeop;Lee, Joung-Dae;Son, Bu-Soon;Lee, Jong-Wha
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.26 no.3
    • /
    • pp.267-276
    • /
    • 2016
  • Objectives: This study, aims to examine the distribution characteristics of asbestos-containing building materials; risk assessment and area of distribution of asbestos-containing building materials depending on year of construction; building materials; types of building materials; and usage in public buildings in order to create fundamental data for safe management of public buildings. Methods: The asbestos investigation was conducted by an asbestos research institution from March to May 2014, targeting 41 public buildings which were subject to asbestos investigation in South Chungcheong-do Province. With respect to 381 presumed asbestos-containing materials, an investigation was conducted into whether they contained asbestos, asbestos type, content, year of construction, and use in the building were examined, and a risk assessment was performed. Results: Asbestos-containing building materials were used in 35 buildings(85.4%). Among them, 31(88.6%) were public buildings. Asbestos was detected in 73% of 381 suspected asbestos-containing materials, which were mostly ceiling materials (85.2%). The older the buildings, the more they showed a tendency to have a significantly higher risk assessment score. The ratio of average area with asbestos-containing building materials to total floor area was 57.6%, 44.1%, and 17.8% for buildings built in the 1980s, 1990s, and 2000s, respectively. This showed a tendency to be significantly higher with the age of the building. Conclusions: From the results above, it can be concluded that with the age of the buildings, the risk assessment score and the ratio of average area with asbestos-containing building materials to total floor area became significantly higher. Given the concern about the exposure to asbestos of residents and civil petitioners, safety management of older public buildings and measures for dismantling and removal of asbestos-containing building materials should therefore be urgently established.

A Study on Unconstitutionality of Insurance Premium Rating System in Accordance with National Health Insurance Act. - Focused on Age and Gender in Premium Rating Standards Activity Rate and Living Standards of the Local Insured - (국민건강보험법상 보험료부과체계에 관한 법적 고찰 -지역가입자 생활수준 및 경제활동 참가율 부과기준 중 성과 연령을 중심으로 -)

  • Song, Kimin;Jeong, Jeong-Ile
    • The Korean Society of Law and Medicine
    • /
    • v.15 no.1
    • /
    • pp.185-209
    • /
    • 2014
  • While the local health insurance and the employment-based insurance were integrated in July 2000, the insured is divided into employment-based insured and the local insured and the relevant premium has been applied to both groups. The health insurance premium having the feature of social solidarity has to be determined depending on income, that is, the ability to pay in accordance with the principles of social insurance. While employment-based insurance premium has been determined depending on the earned income, the local insurance premium for the local insured has been determined by scoring gross income(evaluated income), property and possession of automobiles. A variety of improvement approaches has been implemented including introduction of the employment-based insurance premium ceiling system (2002) and the change of property scoring system for the local insured (2006). However, the health insurance system which was merged in 2000 has been implemented up to now without significant change even though there were lots of socio-demographic change including increase of income level and the population structure such as low birth and aging. In other words, it is required to implement the premium rating system securing the income-based equity. Nevertheless, it was inevitable to apply the diverse rating standards in the early stage because it was very difficult to verify the income of the self-employed. Although the income verification rate was significantly increased from 23% in 1989 to 44% in 2010, the irrational standards including property, automobiles, living standard and activity rate have been still applied to the local insured because it is difficult to secure the validity of insurance premium rating system and it severely lacks of security. This paper investigated whether the current insurance premium rating system for the local insured imposing the premium on the basis of 'gender' and 'age' complies with the basic human rights secured by the current Constitution of the Republic of Korea with respect to the practical and theoretic irrationality of insurance premium rating system and standards for he local insured. In accordance with the analysis results, this paper proposed the approach to improve the system.

  • PDF

Reducing Radiation Exposure Dose on Operator by Using Lateral Protection in Neuro-Intervention (뇌혈관 중재적시술에 있어 측방향 차폐체를 이용한 시술자 피폭 선량 저감화 방법 연구)

  • Kim, Jongdeok;Ahn, ByeoungJu;Lee, Junhaeng
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.1
    • /
    • pp.1-10
    • /
    • 2014
  • The bi-plane cerebrovascular angiography radiation is done the radiation exposure at the forward and lateral direction as opposed to the one of the source. So, the exposure dose of radiation workers increases further. Therefore, the medical diagnostic radiation workers as well as patients is interested to ways to reduce the dose. The exposure dose of cerebral angiography and interventional radiology must be considered the primary radiation of X-ray tube directly, scattered primary radiation between lateral tube and lateral detector and relatively small secondary scatter radiation in the walls of room. The aim of study is that the exposure dose of primary and scatter radiation reduce as much as possible to install protection device of lateral protection than common shielding of table and ceiling. As a result, the dose of fluoroscopy was reduced approximately 3.64 times the gonads, thyroid approximately 3.13 times, 4.42 times around eyes. And the dose of DSA was reduced approximately 4.98 times the gonads, thyroid approximately 3.00 times, 1.67 times around eyes. Consequently, medical practitioners can be helpful for radiation dose-exposure for the lateral protection of bi-plane cerebrovascular angiography more than the common shield method in cerebrovascular angiography and interventional radiological procedures.