• Title/Summary/Keyword: and VP9

Search Result 211, Processing Time 0.021 seconds

The Third-Order Multibit Sigma-Delta Modulator with Data Weighted Averaging (Data Weighted Averaging을 이용한 3차 멀티비트 Sigma-Delta 변조기)

  • 김선홍;최석우;조성익;김동용
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.9
    • /
    • pp.107-114
    • /
    • 2004
  • This paper presents block and timing diagrams of the DWA(Data Weighted Averaging) to optimize a feedback time delay of the sigma-delta modulator. Through the MATLAB modeling, the optimized coefficients of the integrators are obtained to design the modulator. The fully differential SC integrators, feedback DAC, 9-level quantizer, and DWA are designed by considering the nonideal characteristics of the modulator. The designed third-order multibit modulator is fabricated in a 0.35${\mu}{\textrm}{m}$ CMOS process. The modulator achieves 75dB signal-to-noise ratio and 74dB dynamic range at 1.2Vp-p 825kHz input signal and 52.8MHE sampling frequency.

Ecophysiological Interpretations on the Water Relations Parameters of Trees. -I. The Diagnosis of Tolerant Tree to Drought by the Pressure Chamber Technique (수목(樹木)의 수분특성(水分特性)에 관(関)한 생리(生理)·생태학적(生態学的) 해석(解析)(I) - Pressure Chamber Technique에 의한 내건성(耐乾性) 수종(樹種)의 진단(診㫁) -)

  • Han, Sang Sup;Kim, Kwang Ryun
    • Journal of Korean Society of Forest Science
    • /
    • v.50 no.1
    • /
    • pp.25-28
    • /
    • 1980
  • The purpose of the this study was to compare the torlent tree to drought among the Pinus koraiensis, Abies holophylla, and Ginkgo biloba. The water relations parameters of leafy shoots were measured by the Pressure chamber technique from August 10 to September 4 in 1980. On the water relations parameters such as original osmotic pressure(${\pi}_0$), osmotic pressure(${\pi}_p$) and relative water content (RWC) at incipient plasmolysis, and Vp/Vo ratio of the volume of osmotic water (Vp) at incipient plasmolysis to total symplasmic water (Vo) basis, the Abies holophylla shoots showed ontogenetically a superior osmoregulation which are closely associated with drought resistance compared with Pinus koraiensis, and the Ginkgo biloba shoots showed the heighest among these three species.

  • PDF

Comparison on the Dosimetry of TLD and PLD by Dose Area Product (DAP(Dose Area Product)를 이용한 TLD와 PLD의 선량 측정 비교)

  • Choi, Jae-Ho;Kang, Gu-Jun;Chang, Seo-Goo
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.3
    • /
    • pp.244-250
    • /
    • 2012
  • The results of analyzing the difference between performances of individual dosimeters on this research subjecting the PLD and TLD, which are the official personal dosimeters, through dosimetry are as follows. After scanning the integral dose using an automatic scanner, the values of two devices that went through dose adjustment process had a statistical difference in TLD and PLD measurements under each filming conditions which were 70kVp, 200mA, 0.012sec and 42kVp, 100mA, and 0.012sec (p<0.001 and p<0.001 respectively). As for the difference of measurement value between DAP and the two particles under 70kVp, 200mA, 0.012sec filming condition, TLD had a value lower than DAP average value by $44.2mGy{\cdot}cm^2$ and PLD had a value of $246.8mGy{\cdot}cm^2$ which was lower than DAP average value by $15.5mGy{\cdot}cm^2$, while under 42kVp, 100mA, 0.012sec filming condition, TLD had a value lower than DAP average value by $17.9mGy{\cdot}cm^2$ and PLD had a value of $82.6mGy{\cdot}cm^2$ which was lower than DAP average value by 7.6$mGy{\cdot}cm^2$. Also, compared to PLD, each of 10 devices measured dose value in TLD had a larger deviation between the particles, and for a reproducibility test which repeatedly measured one particle, PLD had ${\pm}1%$ which was lower than TLD's ${\pm}2%$. As such, PLD had a superior performance result in dose measurement capacities aspect compared to TLD, and therefore we could verify that PLD is more appropriate and advantageous in managing radiation-related task performing worker's personal radiation exposure management in the diagnostic radiation field.

Humidity Sensitive Properties of Humidity Sensor Using Quaternized Cross-linked Copolymers of 4-Vinylpyridine (4차 염화 가교화된 4-vinylpyridine 공중합체들을 사용한 습도센서의 감습 특성)

  • 공명선;이성수;이임렬
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.14 no.4
    • /
    • pp.302-308
    • /
    • 2001
  • The polymers with various composition of 4-vinylpyridine (4-VP) with n-butyl acrylate (n-BA) and 2-hydroxypropyl methacrylate (HPMA) were synthesized as a humidity sensitive material and quaternized with 1.5-dibromopentane. Resistance versus relative humidity decreased with increase in the content of n-BA in the copolymer. The introduction of HPMA increased the resistance of the humidity sensor as well as enhanced the adherence to the alumina substrate. In the case of 4-VP/n-BA/HPMA=80/10.10, the hysteresis and temperature coefficient were $\pm$2%RH and -0.42∼0.46%RH/$\^{C}$. The average resistance at 30%RH, 60%RH and 90%RH are 3.1㏁, 155 ㏀ and 7.9 ㏀, respectively.

  • PDF

Peculiar Temperature Dependence on the Binding of Acid Dye by Crosslinked Poly(4-vinylpyridine) -The Effect of Inorganic Electrolytes- (가교폴리(4-비닐피리딘)과 산성염료와의 결합에 대한 특이한 온도의존성 - 무기전해질의 효과 -)

  • Lee, Suk Kee
    • Textile Coloration and Finishing
    • /
    • v.9 no.2
    • /
    • pp.25-31
    • /
    • 1997
  • The extent of binding of acid dye (methyl orange) by crosslinked poly-(4-vinylpyridine) (CHP4VP) has been investigated in aqueous solution containing of inorganic electrolytes such as NaCl and NaSCN. It was found that the first binding constants ($K_{1}$) in the presence of the salts were smaller than those in the absence of the salts and the values of $K_{1}$ showed a bell-shaped curve against temperature. These results are discussed in terms of both the competition binding between the dye and salt anions for the crosslinked polymer and the change of hole size of CHP4VP with the addition of the salts.

  • PDF

Diagnostic Reference Levels for Patient Radiation Doses in Pelvis and Lumbar spine Radiography in Korea (우리나라의 골반 및 요추 엑스선검사에서의 환자선량 권고량)

  • Lee, Kwang-Yong;Lee, Byung-Young;Lee, Jung-Eun;Lee, Hyun-Koo;Jung, Seung-Hwan;Kim, Byung-Woo;Kim, Hyeog-Ju;Kim, Dong-Sup
    • Journal of radiological science and technology
    • /
    • v.32 no.4
    • /
    • pp.401-410
    • /
    • 2009
  • Purpose : Pelvis and lumbar spine radiography, among various types of diagnostic radiography, include gonads of the human body and give patients high radiation dose. Nevertheless, diagnostic reference levels for patient radiation dose in pelvis and lumbar spine radiography has not yet been established in Korea. Therefore, the radiation dose that patients receive from pelvis and lumbar radiography is measured and the diagnostic reference level on patient radiation dose for the optimization of radiation protection of patients in pelvis and lumbar spine radiography was established. Methods : The conditions and diagnostic imaging information acquired during the time of the postero-anterior view of the pelvis and the postero-anterior and lateral view of the lumbar spine at 125 medical institutions throughout Korea are collected for analysis and the entrance surface dose received by patients is measured using a glass dosimeter. The diagnostic reference levels for patient radiation dose in pelvis and lumbar spine radiography to be recommended to the medical institutes is arranged by establishing the dose from the patient radiation dose that corresponds to the 3rd quartile values as the appropriate diagnostic reference level for patient radiation dose. Results : According to the results of the assessment of diagnostic imaging information acquired from pelvis and lumbar spine radiography and the measurement of patient entrance surface dose taken at the 125 medical institutes throughout Korea, the tube voltage ranged between 60~97 kVp, with the average use being 75 kVp, and the tube current ranged between 8~123 mAs, with the average use being 30 mAs. In the posteroanterior and lateral views of lumbar spine radiography, the tube voltage of each view ranged between 65~100 kVp (average use: 78 kVp) and 70~109 kVp (average use: 87 kVp), respectively, and the tube current of each view ranged between 10~100 mAs(average use: 35 mAs) and between 8.9~300 mAs(average use: 64 mAs), respectively. The measurements of entrance surface dose that patients receive during the pelvis and lumbar spine radiography show the following results: in the posteroanterior view of pelvis radiography, the minimum value is 0.59 mGy, the maximum value is 12.69 mGy and the average value is 2.88 mGy with the 1st quartile value being 1.91 mGy, the median being 0.59 mGy, and the 3rd quartile value being 3.43 mGy. Also, in the posteroanterior view of lumbar spine radiography, the minimum value is 0.64 mGy, the maximum value is 23.84 mGy, and the average value is 3.68 mGy with the 1st quartile value being 2.41 mGy, the median being 3.40 mGy, and the 3rd quartile value being 4.08 mGy. In the lateral view of lumbar spine radiography, the minimum value is 1.90 mGy, the maximum value is 45.42 mGy, and the average value is 10.08 mGy with the 1st quartile value being 6.03 mGy, the median being 9.09 mGy and the 3rd quartile value being 12.65 mGy. Conclusions : The diagnostic reference levels for patient radiation dose to be recommended to the medical institutes in Korea is 3.42 mGy for the posteroanterior view of pelvis radiography, 4.08 mGy for the posteroanterior view of lumbar spine radiography, and 12.65 mGy for the lateral view of lumbar spine radiography. Such values are all lower than the values recommended by 6 international organizations including World Health Organization, where the recommended values are 10 mGy for the posteroanterior view of pelvis radiography, 10 mGy for the posteroanterior view of lumbar spine radiography and 30 mGy for the lateral view of lumbar spine radiography.

  • PDF

A Study on the Graft Polymerization onto Cellulose Fiber using Tetravalent Cerium- (Ce(IV)감에 의한 셀룰로오스 섬유에의 그라프트 중합에 관한 연구)

  • 배현숙
    • Journal of the Korean Home Economics Association
    • /
    • v.30 no.1
    • /
    • pp.1-9
    • /
    • 1992
  • Graft polymerization mechanism and rate of polymerization of MMA and MMA/4-VP onto cellulose fiber using Ce(IV) salt as an initiatior were investigated. It was shown that the concentration of Ce(IV) salt affected on the graft yield, graft efficiency, total conversion and the rate of graft polymerization. The graft yield and total cenversion for MMA grafted polymer were significantly higher than those for MMA/4-VP grafted polymer with variation of CAN concentration. In this system the oxidative termination by Ce(IV) salt was considered particularly in higher concentration Ce(IV) ion. The change in the mode of termination reactions with variation of CAN concentration made possible the presence of an optimum Ce(IV) ion concentration for maximum graft yield.

  • PDF

Biochemical characterization of Bacillus thuringiensis, 23 serovars (Biochemical thuringiensis, 23 serovars의 생화학적 특성)

  • Lee, Hyung-Hoan;Park, Mi-Yeoun;Lee, Chang-Woon
    • Microbiology and Biotechnology Letters
    • /
    • v.14 no.2
    • /
    • pp.205-208
    • /
    • 1986
  • The 23 serovars of Bacillus thuringiensis strain were commonly gram-positive and motile, formed endotoxin crystals, produced acid and alkali in the KIA media, and acid from glucose, hydrolyzed starch, and reduced nitrate but did not produce H$_2$S, oxidase and indole, did not decompose lysine, ornithine, phenylalanine, malonate, lactose, dulcitol, adonitol, inositol, sorbitol, arabinose, raffinose, rhamnose, maltose, and xylose. Eighteen serovars were positive in the MR tests and 15 in the VP tests. Four serovars used citrate. Five serovars produced urease, 5 $CO_2$ from glucose, 2 DNase, and 15 lecithinase. Twelve serovars decomposed arginine, 11 did sucrose, 2 manitol, and 9 salicin Serovar tohokuensis did not hemolyze, but the others did.

  • PDF

Evaluation of Virtual Grid Software (VGS) Image Quality for Variation of kVp and mAs (관전압과 관전류량 변화에 대한 가상 그리드 소프트웨어(VGS) 화질평가)

  • Chang-gi Kong
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.5
    • /
    • pp.725-733
    • /
    • 2023
  • The purpose of this study is to evaluate the effectiveness of virtual grid software (VGS). The purpose of this study is to evaluate the changes in energy and object thickness by dividing the use of VGS into two cases (Without-VGS) without using a movable grid. We attempted to determine the effectiveness of VGS by acquiring images using a chest phantom and a thigh phantom and analyzing SNR and CNR. In the chest phantom and femoral phantom, the tube flow was fixed at 2.5 mAs, and the tube voltage was changed by 10 kVp from 60 to 100 kVp to measure SNR and CNR, and SNR was about 1.09 to 8.86% higher in the chest phantom than in Without-VGS, and CNR was 4.18 to 14.56% higher in the VGS than in Without-VGS. And in the femoral phantom, SNR was about 9.78 to 18.05% higher in VGS than in Without-VGS, and CNR was 21.07 to 44.44% higher in VGS than in Without-VGS. The tube voltage was fixed at 70 kVp in the chest phantom and the femoral phantom, and the amount of tube current was changed at 2.5 to 16 mAs, respectively, and after X-ray irradiation, SNR and CNR were measured in the chest phantom, which was about 1.49 to 11.11% higher in VGS than in Without-VGS, and CNR was 4.76 to 13.40% higher in VGS than in Without-VGS. And in the femoral phantom, SNR was about 2.22 to 17.38% higher in VGS than in Without-VGS, and CNR was 13.85 to 40.46% higher in VGS than in Without-VGS. Therefore, if an inspection is required with a mobile X-ray imaging device, it is believed that good image quality can be obtained by using VGS in an environment where it is difficult to use a mobile grid, and it is believed that the use of mobile X-ray devices can be increased.

Study for Automatic Exposure Control Technique (AEC) in SPECT/CT for Reducing Exposure Dose and Influencing Image Quality (SPECT/CT에서 자동노출제어(AEC)를 이용함으로써 얻어지는 영상의 질 평가와 피폭선량 감소에 관한 고찰)

  • Yoon, Seok-Hwan;Lee, Sung-Hwan;Cho, Seong-Wook;Kim, Jin-Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.33-38
    • /
    • 2014
  • Purpose Auto exposure control (AEC) in SPECT/CT automatically controls the exposure dose (mA) according to patient's shape and size. The aim of this study was to evaluate the effect of AEC in SPECT/CT on exposure dose reduction and image quality. Materials and Methods The model of SPECT/CT used in this study was Discovery 670 (GE, USA), Smart mA for AEC; and $^{99m}Tc$ as a radioisotope. To compare SPECT and CT images by CT exposure dose variation, we used a standard technique set at 80, 100, 120, 140 kVp, 10, 30, 50, 100, 150, 200, 250 mA, and AEC at 80, 100, 120, 140 kVp, 10-250 mA. To evaluate resolution and contrast of SPECT images, triple line phantom and flangeless Esser PET phantom were used. For CT images, noise and uniformity were checked by anthropomrphic chest phantom. For dose evaluation to find DLP value, anthropomorphic chest phantom was used and the CT protocol of torso was applied by standard technique (120 kVp, 100 mA) and AEC (120 kVp, 10-250 mA). Results When standard and AEC were applied, the resolutions at SPECT images with attenuation correction (AC) were the same as FWHM by center 3.65 mm, left 3.48 mm, right 3.61 mm. Contrasts of standard and AEC showed no significant difference: standard 53.5, 29.8, 22.5, 15.8, 6.0, AEC 53.5, 29.6, 22.4, 15.7, 6.1 In CT images, noise values at standard and AEC were 15.4 and 18.5 respectively. The application of AEC increases noise but the value of coefficient variation were 33.8, 24.9 respectively, obtaining uniform noise image. The values of DLP at standard and AEC were 426.78 and 352.09 each, which shows that the application of AEC decreases exposure dose more than standard by approximately 18%. Conclusion The results of our study show that there was no difference of AC in SPECT images based on the CT exposure dose variation at SPECT/CT images. It was found that the increased CT exposure dose leads to the improvement of CT image quality but also increases the exposure dose. Thus, the use of AEC in SPECT/CT contributes to obtaining equal AC SPECT images, and uniform noise in CT images while reducing exposure dose.

  • PDF