• Title/Summary/Keyword: and VP9

Search Result 208, Processing Time 0.031 seconds

Poly(4-vinylpyridine)/Vinyl Acetate-Vinyl Alcohol Copolymer Blends : 9. Phase. Behavior (폴리(4-비닐피리딘)/비닐아세테이트-비닐알코올 공중합체 블렌드 :2. 상 거동)

  • Lee, Joon-Youl;Choi, Dong-Hoon;Lee, Hyeok
    • Polymer(Korea)
    • /
    • v.25 no.5
    • /
    • pp.649-656
    • /
    • 2001
  • Miscibility of poly(4-vinylpyridine) (P4VP) blends with poly(vinyl acetate-co-vinyl alcohol) (VAc-VAL copolymers) was investigated as a function of comonomer composition of VAc-VAL copolymers. Differential scanning calorimetry (DSC) and thermo-optical microscopic (TOM) analysis confirmed that P4VP is miscible with VAc-VAL copolymers containing more than 30 mole% VAL. Fourier transform inflated (FT-IR) spectroscopic analysis revealed that the strong intermolecular hydrongen bonding interaction between the vinylpyridine and VAL hydroxyl group was formed. Theoretical phase diagram was constructed by the calculation using the Association model, a thermodynamic model for hydrogen-bonded polymer blend systems developed by Coleman et al. The calculated theoretical binodal phase diagrams were in good agreement with the experimentally determined cloud point curves.

  • PDF

Radiation dose Assesment according to the Adaptive Statistical Iterative Reconstruction Technique of Cardiac Computed Tomography(CT) (심장 CT 검사시 ASIR 적용에 따른 선량 평가)

  • Jang, Hyun-Cheol;Kim, Hyun-Ju;Cho, Jae-Hwan
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.5
    • /
    • pp.252-259
    • /
    • 2011
  • To identify the effects of the application of the adaptive statistical iterative reconstruction (ASIR) technique in combination with the other two factors of body mass Index (BMI) and tube potential on radiation dose in cardiac CT. The patient receiving operation the cardiac CT examination was divided four groups into according to kVp.[A group(n=20), Non-ASIR, BMI < 25, 100 kVp; B group(n=20), Non-ASIR, BMI > 25, 120 kVp; C group(n=20), 40% ASIR BMI < 25, 100 kVp; D group(n=20), 40% ASIR, BMI > 25, 120 kVp] After setting up the region of interest in the main artery central part and right coronary artery and left anterior descending artery, the CT number was measured and an average and standard deviation were analyzed. There were A group and the difference which the image noise notes statistically between C. And A group was high so that the noise could note than C group (group A, 494 ${\pm}$ 32 HU; group C, 482 ${\pm}$ 48 HU: P<0.05) In addition, there were B group and the difference noted statistically between D. And B group was high so that the noise could note than D group (group B, 510 ${\pm}$ 45 HU; group D, 480 ${\pm}$ 82 HU: P<0.05). In the qualitative analysis of an image, there was no difference (p>0.05) which a group, B group, C group, and D as to average, A group 4.13${\pm}$0.2, B group 4.18${\pm}$0.1, and C group 4.1${\pm}$0.2 and D group note statistically altogether with 4.15${\pm}$0.1 as a result of making the clinical evaluation according to the coronary artery segments. And the inappropriate image was shown to the diagnosis in all groups. As to the radiation dose, a group 8.6${\pm}$0.9 and B group 14.9${\pm}$0.4 and C group 5.8${\pm}$0.5 and D group are 10.1${\pm}$0.6 mSv.

Selective Chemical Wet Etching of Si0.8Ge0.2/Si Multilayer

  • Kil, Yeon-Ho;Yang, Jong-Han;Kang, Sukil;Jeong, Tae Soo;Kim, Taek Sung;Shim, Kyu-Hwan
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.13 no.6
    • /
    • pp.668-675
    • /
    • 2013
  • We investigate the effect of the ageing time and etching time on the etching rate of SiGe mixed etching solution, namely 1 vp HF (6%), 2 vp $H_2O_2$ (30%) and 3 vp $CH_3COOH$ (99.8%). For this etching solution, we found that the etch rate of SiGe layer is saturated after the ageing time of 72 hours, and the selectivity of $Si_{0.8}Ge_{0.2}$ layer and Si layer is 20:1 at ageing time of 72 hours. The collapse was appeared at the etching time of 9min with etching solution of after saturation ageing time.

Quantitative and Qualitative Evaluation according to Radiation Dose Conditions when using MAR function in Implant examination from Cone Beam CT (ConeBeam CT로 임플란트 검사 시 MAR 기능 유무와 선량조건에 따른 정량적 및 정성적 평가)

  • Hyun-Jun, Ahn;Sang-Hyun, Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.7
    • /
    • pp.905-917
    • /
    • 2022
  • This study was conducted to evaluate the use of the MAR function and the image quality of the image when examining with each radiation dose. A simple Periapical phantom was made to set up an implant, and images were obtained and analyzed according to the presence or absence of MAR function for each radiation dose using CBCT equipment. In this study, MEAN, SNR, and CNR values were obtained using the Image J program, and through statistical analysis, images were the most quantitative and suitable values when the Abutment of Implant was 100 kVp and 8 mA, and when the Center of Implant and Apex of Implant were 100 kVp and 9 mA. As a result, it was confirmed that if the radiation dose increased, the Pixel Value, SNR, and CNR values of the image rose up so that the quality of the image improved, and using the MAR function reduced artifacts.

An Assessment on Cu-Equivalent Image of Digital Intraoral Radiography (디지털구내방사선사진의 구리당량화상에 대한 평가)

  • KIM JAE-DUK
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.29 no.1
    • /
    • pp.33-42
    • /
    • 1999
  • Geometrically standardized dental radiographs were taken. We prepared Digital Cu-Equivalent Image Analyzing System for quantitative assessment of mandible bone. Images of radiographs were digitized by means of Quick scanner and personal Mcquintosh computer. NIH image as software was used for analyzing images. A stepwedge composed of 10 steps of 0.1mm copper foil in thickness was used for reference material. This study evaluated the effects of step numbers of copper wedge adopted for calculating equation. kVp and exposure time on the coefficient of determination(r²)of the equation for conversion to Cu-equivalent image and the coefficient of variation and Cu-Eq value(mm) measured at each copper step and alveolar bone of the mandible. The results were as follows: 1. The coefficients of determination(r²) of 10 conversion equations ranged from 0.9996 to 0.9973(mean=0.9988) under 70kVp and 0.16 sec. exposure. The equation showed the highest r was Y=4.75614612-0.06300524x +0.00032367x² -0.00000060x³. 2. The value of r² became lower when the equation was calculated from the copper stepwedge including 1.0mm step. In case of including 0mm step for calculation. the value of r showed variability. 3. The coefficient of variation showed 0.11, 0.20 respectively at each copper step of 0.2, 0.1mm in thickness. Those of the other steps to 0.9 mm ranged from 0.06 to 0.09 in mean value. 4. The mean Cu-Eq value of alveolar bone was 0.14±0.02mm under optimal exposure. The values were lower than the mean under the exposures over 0.20sec. in 60kVp and over 0.16sec. in 70kVp. 5. Under the exposure condition of 60kVp 0.16sec.. the coefficient of variation showed 0.03. 0.05 respectively at each copper-step of 0.3, 0.2mm in thickness. The value of r² showed over 0.9991 from both 9 and 10 steps of copper. The Cu-Eq value and the coefficient of variation was 0.14±0.01mm and 0.07 at alveolar bone respectively. In summary. A clinical application of this system seemed to be useful for assessment of quantitative assessment of alveolar provided high coefficient of determination is obtained by the modified adoption of copper step numbers and the low coefficient of variation for the range of Cu-Equivalent value of alveolar bone from optimal kVp and exposure time for each x-ray machine.

  • PDF

Usefulness of Application of Tube Voltage Changes to Reduce Patient Dose during Abdominal CT Follow up (반복적인 복부 컴퓨터단층촬영 시행 시 환자선량 감소를 위한 관전압 변화 적용의 유용성)

  • Yoon, Joon;Kim, HyeonJu
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.3
    • /
    • pp.293-299
    • /
    • 2021
  • In order to reduce the irresistible radiation exposure of patients who perform periodic examinations using a CT among various scan parameters a method to reduce patient dose was investigated through changes in the tube voltage close to X-ray penetrating power. As a result of the experiment 100 kVp was applied instead of 120 kVp which is commonly used in clinical practice and CTDI decreased by about 41% during scan. In addition the degree of change in image quality was measured as 1046.1±3.7 HU for CT value and 71.4±7.9 for Pixel value and statistical analysis showed no significant difference (0.05

A Study on the Detection Ability of Minute Lesions in X-ray Using the Molybdenum Target (Molybdenum 저지극을 이용한 X-ray의 미세병소 검출능력에 관한 연구)

  • Yang, Da-Rae;Dong, Kyung-Rae;Park, Yong-Soon;Ji, Youn-Sang;Kim, Young-Keun;Kim, Chang-Bok
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.1
    • /
    • pp.43-48
    • /
    • 2010
  • Beam quality is determined according to Xray tube's target material. In a range of between 22 kVp and 28 kVp, molybdenum target generates the characteristics energy between the average 17.9 kVp and 19.5 kVp, which produces the high contrast image of the breast. In this study, we used the Mo/Mo combination breast device and ALVIM TRM phantom and measured the detection ability of the minute lesion in the breast imaging throughout analyzing ROC curves. Assuming that an average subject thickness of the breast is 40 mm, the detection ability was not dependent on the kVp changes in a while dependent on both the mAs and thickness change. We can assure that it is not needed to increase the kVp for the imaging of breast which thickness is within the mean range of 40 mm.

Experimental Infection for the Neutralization of White Spot Syndrome Virus (WSSV) in Wild Captured Sand Shrimp, Crangon affinis (자연산 자주새우(Crangon affinis)에서 흰반점바이러스(WSSV)의 neutralization을 위한 인위감염(experimental infection))

  • Gong, Soo-Jung;Kim, Yeong-Jin;Choi, Mi-Ran;Kim, Sung-Koo
    • Journal of Life Science
    • /
    • v.20 no.9
    • /
    • pp.1294-1298
    • /
    • 2010
  • White spot syndrome virus (WSSV) is one of the most virulent viral agents threatening the penaeid shrimp culture industry. This study was carried out to evaluate the susceptibility of the sand shrimp, Crangon affinis, to WSSV as an alternative experimental model. WSSV caused 100% mortality in C. affinis within 7 days after experimental infection by immersion. Based on challenge studies, it was confirmed that C. affinis could be a potential host in WSSV transmission. Also, the neutralization of WSSV was carried out using an antiserum raised against recombinant envelop protein rVP466 to evaluate the WSSV infection mechanism. A constant amount of WSSV (at $1{\times}10^4$ diluted stocks) was incubated with various amounts of antiserum and then mixed to 20 l reservoir for the immersion challenge of C. affinis for neutralization. At 5 days post challenge, the shrimp in the positive control immersed in the immersion reservoir containing WSSV stock showed 100% mortality. The shrimps challenged with the 3 different mixtures of WSSV and rVP466 antiserum (1:0.1, 1:0.5 and 1:1) showed 100%, 68.8% and 68.8% mortality at 14 days post challenge, respectively. These results indicated that the antiserum raised against rVP466 could block WSSV infection in C. affinis. Therefore, this study confirmed that C. affinis can be naturally infected by WSSV as another potential host and that C. affinis can be used as an alternative experimental animal instead of penaeid shrimps.

Research on the Visual Historical & Cultural Resources of Seongbuk-dong (서울 성북동 역사문화자원 주변경관의 시각적 특성연구)

  • Lee, Won-Ho;Kim, Jae-Ung
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.31 no.2
    • /
    • pp.118-127
    • /
    • 2013
  • In this study, Seongbuk-dong historical & cultural resources of the surrounding landscape were analyzed by the visual characteristics of the landscape adjective analysis. Research was investigate to the relationship between visual characteristics and preferences and Research in the following way. Selected historical and cultural resources in the surrounding area are located in Seongbuk-dong 30 slices the survey was conducted. Landscape preference factors to identify the scale of 16 adjectives and then factor analysis was conducted. Lastly, Analysis of variance and regression analysis were conducted in order to determine the impact of the last image factors on visual preferences. Firstly, The results can be summarized as follows. Officer for 30 pictures appear in Seongbuk-dong in the historical and cultural resources, and distributed around the target preference for the 16 adjectives analysis yielded an average result of overall preference were analyzed and that is a 3.72 average. In these photos, VP8, VP9, VP10, VP12, VP15; 4.5 points more than one order higher. The reason is limit of altitude by the Seoul landscape plan for the historical and cultural resources around. It also judged important reason that history and Culture are in harmony with the surrounding cultural property in the conservation area. Secondly, Important factors are factor 1(aesthetic factors), factor 2(cultural factors), factor 3(physical factors) and three factors could be identified. Results of the analysis of variance and regression analysis about factors for visual preference and image shows value of psychological factor is most significant to explain for nearby history &cultural resources of Seongbuk-dong of scenery around. As a result, the state can not view historical and cultural resources for analysis will be located in a residential area near the historical and cultural resources for aesthetic factors. Third, the negative side of the argument is a residential area which is not arranged surrounding landscape maintenance of historical and cultural resources has emerged. Historical and cultural resources in harmony with the phenomena of the physical, cultural, and aesthetic characteristics of the three areas is a positive factor in the high incidence. Factors from that are expressed in this study by analyzing multi-dimensional analysis to derive a factor to be considered important in the management of historical and cultural resources, landscape around is required.

Rotavirus P and G Genotypes Circulating in Kyungsangnamdo, Korea, during 2000~2001 (2000~2001년 경상남도에서 유행한 로타바이러스 유전자형)

  • So, Kyeung Jin;Lee, Mi Hyun;Ma, Sang Hyeok;Kim, Byung Chyeol;Yang, Jai Myung
    • Pediatric Infection and Vaccine
    • /
    • v.11 no.1
    • /
    • pp.59-72
    • /
    • 2004
  • Purpose : Rotaviruses are the major cause of gastroenteritis in infants and young children worldwide. It is important to get the epidemiologic data of rotavirus genotype for the application of rotavirus vaccine. So we tried to investigate the distribution of rotavirus genotypes with RT-PCR. Methods : A total of 120 rotavirus latex agglutinin test positive stool samples were collected continually from 120 children from Sep. 2000 to Apr. 2001. Rotavirus P(VP4), G (VP7) genotypes were determined by RT-PCR. Results : The genotype was identified in 116 stool samples of total 120 samples(96%). The incidence of G genotype was as follow; G1 17(14.2%), G2 74(61.7%), G4 1(0.8%), G9 1(0.8%). There were four cases of multiple genotypes; G1/G2, G1/G4, G1/G9, G8/G9 and genotype of G3, G8 were not found. Twenty three(19.2%) samples were nontypeable. The incidence of P was as follow; P[4] 77(64.2%), P[6] 22(18.3%), P4/P6 12(10%), P[4]/P[8] 1(0.8%) p[8] 1(0.8%). Seven(5.9%) samples were nontypeable. Conclusion : Various combinations of G and P genotypes were observed. Most rotavirus strains were P[4]G2 62(51.74%), followed by P[6]G2 7(5.8%), and P[6]G1 7(5.8%), P[4/P[6] G1 4(3%), P[4]/P[6]G2 4(3%), P[4]G1 3(2.5%), P[8]G2 1(0.8%), P[4]G4 1(0.8%) in Kyoungsangnamdo, Korea during 2000~2001.

  • PDF