• Title/Summary/Keyword: acquisition time

Search Result 2,020, Processing Time 0.026 seconds

A new algorithm for fast acquisition for direct-sequence spread-spectrum systems (직접시퀀스 확산대역 시스템의 빠른 포착을 위한 새로운 알고리듬)

  • 이명환;이재홍
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.32A no.7
    • /
    • pp.8-15
    • /
    • 1995
  • We have proposed a new fast serial serch algorithm and a receiver for direct-sequence spead-spectrum acquisition systems and analyzed its perfoemance. This algorithm achieves faster acquisition by more than two times that of existing algorithm. We have derived equations of the mean acquistion time by using moment generating function and direct approach, and presented numerical results.

  • PDF

Development of Data Acquisition System for Strain Gauge Sensor (스트레인게이지 센서용 데이터획득시스템의 개발)

  • Cho, Si-Hyeong;Park, Chan-Won
    • Journal of Industrial Technology
    • /
    • v.30 no.A
    • /
    • pp.89-93
    • /
    • 2010
  • This research suggested a development of a Data Acquisition System for strain gauge sensor which enables the usage of portable device in the various engineering field that includes, a strain indicator which is frequently used in civil and mechanical engineering, and a GUI function of data acquisition device. The developed system can record 16 channels of strain gauges at a time and its resolution is over 16 bits which can be used effectively in the actual field.

  • PDF

대학도서관 자료처리 원가계산에 관한 연구

  • 이경호;심의순
    • Journal of Korean Library and Information Science Society
    • /
    • v.10
    • /
    • pp.157-191
    • /
    • 1983
  • The purpose of the study is to build a general cost a counting model for university libraries, to clarify the possible areas of its a n.0, pplication by employing job cost accounting and process cost accounting methods. System analysis is performed as to the fields of acquisition, processing (cataloging & classification), and book shelving system. The existing operation processes and time required for each operation of these three systems are analyzed, from which detailed system flowcharts were drawn and job descriptions and the content of job were identified. The results of the study can be summarized as follows: (1) The processing time of one book in each systems: Oriental books. a. Acquisition system. the time required the time required in case of job cost case of job cost accounting after purchasing, 8 min. 21 sec. the time required in case of process cost accounting 15 min. 7 sec. b. Processing system. the time required for non-duplicate, 34 min. 40 sec. the time required for duplicate, 8 min. 49 sec. the time required for purchasing of more than the time required two copies at a time. 4 min. 44 sec. c. Book shelving system. the time required. 1 min. 43 sec. Western books. a. Acquisition system the required in case of job cost accounting, 9 min. 1 sec. the time required in case of process cost accounting. 15 min. 7 sec. b. Processing system. the time required for non-duplicate, 32 min. 58 sec. the time required for duplicate, 9 min. 26 sec. the time required for purchasing of more than two copies at a time. 5 min. 33 sec. c. Book shelving system. the time required. 1 min. 43 sec. (2) Total sum of processing time and processing cost per book. Oriental books (including material cost) the time required. cost. a. non-duplicate, 51 min. 30 sec. 2, 791 won b. duplicate, 25 min. 39 sec. 1, 580 won c. purchasing of more than two copies as a time, 21 min. 34 sec. 1, 368 won Western books(including material cost) a. non-duplicate, 49 min. 48 sec. 3, 189 won b. duplicate, 26 min. 16 sec. 1, 846 won c. purchasing of more than two copies at a time. 22 min. 23 sec. 1, 388 won

  • PDF

A Study on the Optimal Image Acquisition Time of 18F- Flutemetamol using List Mode (LIST mode를 이용한 18F-Flutemetamol 의 최적 영상획득 시간에 관한 연구)

  • Ryu, Chan-Ju
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.891-897
    • /
    • 2021
  • With the development of Amyloid PET Tracer, the accuracy of Alzheimer's diagnosis can be improved through the identification of beta-amyloid neurites. However, the long image acquisition time of 20 minutes can be difficult for the patient. PET/CT scans are sensitive to patient movement and may partially affect test results. In this study, we studied the proper image acquisition time without affecting the quantitative evaluation of the image through the list mode acquisition method according to the time of the distribution of radioactive drugs in the body. The list mode includes information about time compared to the existing frame mode, and it is easy to analyze data because it can reconstruct images about the time that researchers want. The research method obtained a reconstructed image by time using a list mode of 5min frame/bed, 10min frame/bed, 15min frame/bed, and 20min frame/bed to compare the difference between signal-to-pons take ratio (SNR) and lesion-to-pons uptake ratio (LPR) and the difference in reading time to obtain an appropriate image. As a result of quantitative analysis, when measuring in list mode, SUVmean values decreased in 6 regions of interest as the image acquisition time increased, but showed the largest difference in 5 min/bed images, followed by 10 min/bed and 15 min/bed. As a result, the difference in SUVmean values decreased. Therefore, it was found that SUVmean values at 15 min/bed did not differ enough to not affect image evaluation. There was no difference in LPR values. As a result of the qualitative analysis, there was no change in the reading findings according to the PET image acquisition time and there was no significant difference in the qualitative analysis score of the image reconstruction according to time. As a result of the study, there is no significant difference between 15 min/bed and 20 min/bed images during the 18F-flutemetamol PET/CT test, so it can be said that it is clinically useful to reduce the image acquisition time selectively using 15 min/bed via list mode depending on the patient's condition.

The Impact of Personality and Self-Identity on Online Information Acquisition and Information Transmission and SNS Usage (자아정체성과 성격이 SNS 이용, 온라인 정보취득과 정보전달에 미치는 영향에 관한 연구)

  • Kim, Jin-Young
    • Journal of Digital Convergence
    • /
    • v.15 no.11
    • /
    • pp.433-440
    • /
    • 2017
  • The present study explored the impact of personality and self-identity on online information acquisition, information transmission and the usage of SNSs. Participants were 180 students, SNS users, from a university in Korea. Among the participants, 171 students completed all surveys. As a results, personality traits such as openness, extraversion, agreeableness, neuroticism were positively related to the SNS usage and information behaviors. Social identity orientation was associated with time spent of SNS and the number of friends whereas collective identity orientation was related to information acquisition. As a result of multiple regression, time spent, openness, agreeableness, collective identity were significant predictors of information acquisition. The number of SNS in use, time spent of SNS, openness, neuroticism were predictors of information transmission. However, as the predictor of information transmission, neuroticism showed inverse relationship with information transmission.

Assessment of Left Ventricular Function with Single Breath-Hold Magnetic Resonance Cine Imaging in Patients with Arrhythmia

  • Bak, So Hyeon;Kim, Sung Mok;Park, Sung-Ji;Kim, Min-Ji;Choe, Yeon Hyeon
    • Investigative Magnetic Resonance Imaging
    • /
    • v.21 no.1
    • /
    • pp.20-27
    • /
    • 2017
  • Purpose: To evaluate quantification results of single breath-hold (SBH) magnetic resonance (MR) cine imaging compared to results of conventional multiple breath-hold (MBH) technique for left ventricular (LV) function in patients with cardiac arrhythmia. Materials and Methods: MR images of patients with arrhythmia who underwent MBH and SBH cine imaging at the same time on a 1.5T MR scanner were retrospectively reviewed. Both SBH and MBH cine imaging were performed with balanced steady state free precession. SBH scans were acquired using temporal parallel acquisition technique (TPAT). Fifty patients ($65.4{\pm}12.3years$, 72% men) were included. End-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), ejection fraction (EF), myocardial mass, and LV regional wall motion were evaluated. Results: EF, myocardial mass, and regional wall motion were not significantly different between SBH and MBH acquisition techniques (all P-values > 0.05). EDV, ESV, and SV were significant difference between the two techniques. These parameters for SBH cine imaging with TPAT tended to lower than those in MBH. EF and myocardial mass of SBH cine imaging with TPAT showed good correlation with values of MBH cine imaging in Passing-Bablok regression charts and Bland-Altman plots. However, SBH imaging required significantly shorter acquisition time than MBH cine imaging ($15{\pm}7sec$ vs. $293{\pm}104sec$, P < 0.001). Conclusion: SBH cine imaging with TPAT permits shorter acquisition time with assessment results of global and regional LV function comparable to those with MBH cine imaging in patients with arrhythmia.

Constructing a Automatic Real-time Line-Scan Inspection System (실시간 자동 검사를 위한 라인 스캔 컴퓨터 비전 시스템의 연구)

  • Jang, Dong-Sik;Kim, Yong-Deok
    • IE interfaces
    • /
    • v.9 no.1
    • /
    • pp.73-82
    • /
    • 1996
  • The purpose of this research is to construct real-time image acquisition system for a line-scan inspection system as a computer vision system. To construct the line-scan inspection system, many problem arise. However, problems of image acquisitions using linear CCD are practically studied in this paper. These problems are concerned to proper lighting systems, relations with handling system, camera systems, and impacts due to the noise of environment. These problems are examined separately, and proper configurations for each case are suggested to construct the line-scan image acquisition system.

  • PDF

Implementation of a Labview Based Time-Frequency Domain Reflectometry Real Time System using the PXI Modules (PXI모듈을 이용한 랩뷰 기반 시간-주파수 영역 반사파 실시간 계측 시스템 구현)

  • Park, Tae-Geun;Kwak, Ki-Seok;Park, Jin-Bae;Yoon, Tae-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2006.04a
    • /
    • pp.336-338
    • /
    • 2006
  • One of the important topics concerning the safety of electrical and electronic system is the reliability of the wiring system. The Time-Frequency Domain Reflectometry(TFDR) is a state-of-the-art system for detection and estimation of the fault on a wiring/cable. The purpose of this paper is to implement a Labview based TFDR Real Time system though the instruments of PCI extensions for Instrumentation(PXI). The TFDR Real Time system consists of the five parts: Reference signal design, signal generation, signal acquisition, algorithm execution, results diplay part. In the signal generation and acquisition parts we adopt the Arbitrary Waveform Generator(AWG) and Digital Storage Oscilloscope(DSO) PXI modules which offer commonality, compatibility and easy integration at low cost. And execution of the PXI modules not only is controlled by the Labview programing but also the total system process is executed by the Labview application software.

  • PDF

Performance Analysis of UMB Signal Acquisition Algorithms According to Frame Interval and Bin Spacing in indoor Wireless Channels (실내 무선 환경에서 프레임 및 탐색 단위 구간에 따른 UWB 신호 동기 획득 알고리즘의 성능 분석)

  • Oh jong ok;Yang Suck chel;An Yo Shin
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.12C
    • /
    • pp.1623-1632
    • /
    • 2004
  • In this paper, we analyze the performance of linear search and bit reversal search algorithms based on the single-dwell serial search for rapid UWB (Ultra Wide Band) signal acquisition in typical indoor wireless channel environments. Simulation results according to bin spacing and frame interval in IEEE 802.15 Task Group 3a UWB indoor wireless channels show that bit reversal search algorithm achieves much smaller normalized mean acquisition time than linear search algorithm. In particular, it is found that the normalized mean acquisition time of the bit reversal search according to the range of searching termination interval closely matches the ideal case. In addition, we observe that the acquisition performance of bit reversal search algorithm becomes much better as bin spacing gets finer.

A DSP Evaluation System with variable Data Acquisition Buffer Architecture for Real Time Signal Processing (실시간 신호처리를 위한 가변구조 Data Acquisition Buffer의 구조를 갖는 DSP평가용 System.)

  • Ahn D. S.;Seo H. S.;Cha I. W.
    • The Journal of the Acoustical Society of Korea
    • /
    • v.8 no.5
    • /
    • pp.95-101
    • /
    • 1989
  • For developing new algorithms or dedicated hardware by using general purpose Digital Signal Processor chip, emulator H/W and simulator S/W are indispensible. But the most of DSP emulators have limitations on H/W flexibility according to their generalized architectures. In this paper, a DSP evaluation system for real time signal processing was developed using TMS 32020. The I/O buffers storing acquisition data of the system were designed to have variable length $(1\sim2048samp1es) &$ sampling frequency $l00\sim8KHz$.

  • PDF