DOI QR코드

DOI QR Code

Assessment of Left Ventricular Function with Single Breath-Hold Magnetic Resonance Cine Imaging in Patients with Arrhythmia

  • Bak, So Hyeon (Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine) ;
  • Kim, Sung Mok (Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine) ;
  • Park, Sung-Ji (Cardiovascular Imaging Center, Heart Vascular Stroke Institute, Samsung Medical Center, Sungkyunkwan University School of Medicine) ;
  • Kim, Min-Ji (Biostatistics and Clinical Epidemiology Center, Samsung Medical Center) ;
  • Choe, Yeon Hyeon (Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine)
  • Received : 2017.01.05
  • Accepted : 2017.03.16
  • Published : 2017.03.30

Abstract

Purpose: To evaluate quantification results of single breath-hold (SBH) magnetic resonance (MR) cine imaging compared to results of conventional multiple breath-hold (MBH) technique for left ventricular (LV) function in patients with cardiac arrhythmia. Materials and Methods: MR images of patients with arrhythmia who underwent MBH and SBH cine imaging at the same time on a 1.5T MR scanner were retrospectively reviewed. Both SBH and MBH cine imaging were performed with balanced steady state free precession. SBH scans were acquired using temporal parallel acquisition technique (TPAT). Fifty patients ($65.4{\pm}12.3years$, 72% men) were included. End-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), ejection fraction (EF), myocardial mass, and LV regional wall motion were evaluated. Results: EF, myocardial mass, and regional wall motion were not significantly different between SBH and MBH acquisition techniques (all P-values > 0.05). EDV, ESV, and SV were significant difference between the two techniques. These parameters for SBH cine imaging with TPAT tended to lower than those in MBH. EF and myocardial mass of SBH cine imaging with TPAT showed good correlation with values of MBH cine imaging in Passing-Bablok regression charts and Bland-Altman plots. However, SBH imaging required significantly shorter acquisition time than MBH cine imaging ($15{\pm}7sec$ vs. $293{\pm}104sec$, P < 0.001). Conclusion: SBH cine imaging with TPAT permits shorter acquisition time with assessment results of global and regional LV function comparable to those with MBH cine imaging in patients with arrhythmia.

Keywords

References

  1. Rokey R, Wendt RE, Johnston DL. Monitoring of acutely ill patients during nuclear magnetic resonance imaging: use of a time-varying filter electrocardiographic gating device to reduce gradient artifacts. Magn Reson Med 1988;6:240-245 https://doi.org/10.1002/mrm.1910060213
  2. Juergens KU, Fischbach R. Left ventricular function studied with MDCT. Eur Radiol 2006;16:342-357 https://doi.org/10.1007/s00330-005-2888-5
  3. Bak SH, Ko SM, Jeon HJ, Yang HS, Hwang HK, Song MG. Assessment of global left ventricular function with dualsource computed tomography in patients with valvular heart disease. Acta Radiol 2012;53:270-277 https://doi.org/10.1258/ar.2011.110247
  4. Niendorf T, Sodickson DK. Highly accelerated cardiovascular MR imaging using many channel technology: concepts and clinical applications. Eur Radiol 2008;18:87-102 https://doi.org/10.1007/s00330-007-0692-0
  5. Wintersperger BJ, Reeder SB, Nikolaou K, et al. Cardiac CINE MR imaging with a 32-channel cardiac coil and parallel imaging: impact of acceleration factors on image quality and volumetric accuracy. J Magn Reson Imaging 2006;23:222-227 https://doi.org/10.1002/jmri.20484
  6. Cawley PJ, Maki JH, Otto CM. Cardiovascular magnetic resonance imaging for valvular heart disease: technique and validation. Circulation 2009;119:468-478 https://doi.org/10.1161/CIRCULATIONAHA.107.742486
  7. Nassenstein K, Eberle H, Maderwald S, et al. Single breathhold magnetic resonance cine imaging for fast assessment of global and regional left ventricular function in clinical routine. Eur Radiol 2010;20:2341-2347 https://doi.org/10.1007/s00330-010-1827-2
  8. Vincenti G, Monney P, Chaptinel J, et al. Compressed sensing single-breath-hold CMR for fast quantification of LV function, volumes, and mass. JACC Cardiovasc Imaging 2014;7:882-892 https://doi.org/10.1016/j.jcmg.2014.04.016
  9. Saremi F, Grizzard JD, Kim RJ. Optimizing cardiac MR imaging: practical remedies for artifacts. Radiographics 2008;28:1161-1187 https://doi.org/10.1148/rg.284065718
  10. Pruessmann KP, Weiger M, Scheidegger MB, Boesiger P. SENSE: sensitivity encoding for fast MRI. Magn Reson Med 1999;42:952-962 https://doi.org/10.1002/(SICI)1522-2594(199911)42:5<952::AID-MRM16>3.0.CO;2-S
  11. Bassett EC, Kholmovski EG, Wilson BD, et al. Evaluation of highly accelerated real-time cardiac cine MRI in tachycardia. NMR Biomed 2014;27:175-182 https://doi.org/10.1002/nbm.3049
  12. Cerqueira MD, Weissman NJ, Dilsizian V, et al. Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart. A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association. Circulation 2002;105:539-542 https://doi.org/10.1161/hc0402.102975
  13. Nucifora G, Muser D, Masci PG, et al. Prevalence and prognostic value of concealed structural abnormalities in patients with apparently idiopathic ventricular arrhythmias of left versus right ventricular origin: a magnetic resonance imaging study. Circ Arrhythm Electrophysiol 2014;7:456-462 https://doi.org/10.1161/CIRCEP.113.001172
  14. Kozerke S, Plein S. Accelerated CMR using zonal, parallel and prior knowledge driven imaging methods. J Cardiovasc Magn Reson 2008;10:29 https://doi.org/10.1186/1532-429X-10-29
  15. Theisen D, Sandner TA, Bamberg F, et al. High-resolution cine MRI with TGRAPPA for fast assessment of left ventricular function at 3 Tesla. Eur J Radiol 2013;82:e219-224 https://doi.org/10.1016/j.ejrad.2012.12.019
  16. Wintersperger BJ, Sincleair S, Runge VM, et al. Dual breath-hold magnetic resonance cine evaluation of global and regional cardiac function. Eur Radiol 2007;17:73-80
  17. Duarte R, Fernandez-Perez G, Bettencourt N, et al. Assessment of left ventricular diastolic function with cardiovascular MRI: what radiologists should know. Diagn Interv Radiol 2012;18:446-453
  18. Feng L, Srichai MB, Lim RP, et al. Highly accelerated realtime cardiac cine MRI using k-t SPARSE-SENSE. Magn Reson Med 2013;70:64-74 https://doi.org/10.1002/mrm.24440
  19. Niendorf T, Sodickson DK. Parallel imaging in cardiovascular MRI: methods and applications. NMR Biomed 2006;19:325-341 https://doi.org/10.1002/nbm.1051
  20. Chandler AG, Pinder RJ, Netsch T, et al. Correction of misaligned slices in multi-slice cardiovascular magnetic resonance using slice-to-volume registration. J Cardiovasc Magn Reson 2008;10:13 https://doi.org/10.1186/1532-429X-10-13
  21. Breuer FA, Kellman P, Griswold MA, Jakob PM. Dynamic autocalibrated parallel imaging using temporal GRAPPA (TGRAPPA). Magn Reson Med 2005;53:981-985 https://doi.org/10.1002/mrm.20430
  22. Nael K, Ruehm SG, Michaely HJ, et al. High spatialresolution CE-MRA of the carotid circulation with parallel imaging: comparison of image quality between 2 different acceleration factors at 3.0 Tesla. Invest Radiol 2006;41:391-399 https://doi.org/10.1097/01.rli.0000197978.88991.17
  23. Heilmaier C, Nassenstein K, Nielles-Vallespin S, Zuehlsdorff S, Hunold P, Barkhausen J. Assessment of left ventricular function with single breath-hold highly accelerated cine MRI combined with guide-point modeling. Eur J Radiol 2010;74:492-499 https://doi.org/10.1016/j.ejrad.2009.03.028
  24. Eberle HC, Nassenstein K, Jensen CJ, et al. Rapid MR assessment of left ventricular systolic function after acute myocardial infarction using single breath-hold cine imaging with the temporal parallel acquisition technique (TPAT) and 4D guide-point modelling analysis of left ventricular function. Eur Radiol 2010;20:73-80 https://doi.org/10.1007/s00330-009-1522-3
  25. Hunold P, Maderwald S, Ladd ME, Jellus V, Barkhausen J. Parallel acquisition techniques in cardiac cine magnetic resonance imaging using TrueFISP sequences: comparison of image quality and artifacts. J Magn Reson Imaging 2004;20:506-511 https://doi.org/10.1002/jmri.20125

Cited by

  1. Biases in the Assessment of Left Ventricular Function by Compressed Sensing Cardiovascular Cine MRI vol.23, pp.2, 2019, https://doi.org/10.13104/imri.2019.23.2.114