• Title/Summary/Keyword: a chamber

Search Result 6,531, Processing Time 0.038 seconds

Laboratory-scale fruiting body formation of Pleurotus ostreatus using the petri dish culture (느타리의 기내 자실체 형성 및 그 유도조건에 관한 연구)

  • Joh, Joong-Ho;Chu, Kyo-Sun;Kim, Beom-Gi;Kong, Won-Sik;Yoo, Young-Bok;Lee, Seung-Jae;Cho, Bong-Gum;Lee, Chang-Soo
    • Journal of Mushroom
    • /
    • v.2 no.1
    • /
    • pp.15-20
    • /
    • 2004
  • Pleurotus ostreatus, the oyster mushroom, is one of the most widely cultivated and important edible mushrooms in the world. In order to study the developmental process of P. ostreatus and its regulatory mechanism, a new culturing method needs to be established for inducing the fruiting body and sporulation in the laboratory. In this study, we have examined whether the fruiting body of P. ostreatus can be formed on the plastic petri dish which are commonly used for cell culture in the laboratory. The strain was cultured on $60{\times}15mm$ plastic petri dish with potato dextrose agar media at $28^{\circ}C$ for mycelial growth and then at $18^{\circ}C$ for the formation of primordia and fruiting bodies within plant growth chamber. The development of primordia into fruiting bodies was achieved on cultured dishes under air ventilation. At the primordia stage, the normal formation of fruiting body was blocked by sealing the plastic dish with parafilm. The periods requiring for the formation of primordia and fruiting bodies were examined on the dish culture. About 96% and 76% of cultured samples formed primordia and fruiting bodies under the optimal conditions during ten weeks of culture, respectively. These culturing periods, however, were changed by the mechanical injury treatment to mycelia. As other factors affecting the fruiting body formation, the effects of light and cold shock have been tested. No fruiting formation was observed on the cultured dishes under the dark. The cold shock treatment by storing cultured dishes for one day at $4^{\circ}C$ did not have any significant effects in the fruiting body formation. Spores of fruiting bodies acquired from the petri dishes could be germinated on culture media at $28^{\circ}C$. These results suggest that the fruiting bodies of P. ostreatus can be formed on the experimental petri dish and this dish-culturing method is useful for understanding of the developmental process of P. ostreatus in the laboratory. Furthermore, the dish-culturing method is able to shorten the life cycle of P. ostreatus without requiring large area and expensive device.

  • PDF

Study of Environmental Stability of the East Sea by Foraminiferal Distribution (유공충을 이용한 동해의 환경 안정성 연구)

  • Shin, Im-Chul;Yi, Hi-Il
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.3 no.4
    • /
    • pp.234-248
    • /
    • 1998
  • Seven box cores from the disposal areas located in the southern part of the East Sea (Stations Band B') and in the offshore to the east of Pusan (Stations J and J'), and from their surrounding areas (Stations J2, J6 and H) were collected to investigate the effect of dumped wastes on the foraminiferal assemblages. The species diversity indices [S, H(S), E] of foraminifera and the total number of foraminifera show significant differences between the ocean waste disposal areas and their adjacent areas. Ocean waste disposal areas located in southern part of the East Sea (Stations Band B') show not only smaller number of foraminifera species but also lower values of coarse fraction content in the sediment and the number of benthic and planktonic foraminifera than the surrounding areas. Another ocean disposal area located offshore Pusan (Station J') contains abnormally greater number of planktonic (approximately 300 000 individuals/lO g dried sediment) and benthic (approximately 300, 000 individuals/10 g dried sediment) foraminifera compared to those of the adjacent areas. The waste dumped at Station J' probably acts as a nutrient causing the greater number of foraminifera. Station J shows low species diversity indices [S, H(S)]. The number of benthic foraminifera decreases from the surface to the downcore at Station J, which indicates that Station J is under stress. However, Stations J', J2 and J6 are under stable conditions as evidenced by the greater species diversity indices [S, H(S)] compared to other stations. No foraminifera were found with biological disease or abnormal chambers, which commonly occur in extremely stressed environment, in both the ocean disposal and adjacent areas. The organic matter decay of the wastes dumped in the study areas has not made the bottom water corrosive.

  • PDF

Effects of Barley Straw Management Practices on Greenhouse Gases(GHGs) Emission During Rice Cultivation in Rice-barley Double Cropping System (벼보리 이모작 재배에서 보리짚 처리 방법이 벼재배시 온실가스 배출에 미치는 영향)

  • Ko, Jee-Yeon;Lee, Jae-Saeng;Jung, Ki-yul;Choi, Young-Dae;Ramos, Edwin P;Yun, Eul-Soo;Kang, Hwang-Won;Park, Seong-Tae
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.41 no.1
    • /
    • pp.65-73
    • /
    • 2008
  • Because main barley straw management is changing these days from off-fields to burning that may relate to air quality concerning the global warming, this study was conducted to investigate the effects of barley-straw management practices on greenhouse gas emissions during rice cultivation in rice-barley double cropping system. The treatments were barley straw burning, off-field usage of barley straw and incorporation of barley straw in paddy fields. Laboratory experiment showed that burning of barley straw at the rate of $4.5Mg\;ha^{-1}$ emitted GHGs in the amounts of 4,607, 19.5, and $0.9kg\;ha^{-1}$ of $CO_2$, $CH_4$, and $N_2O$, respectively. During the rice cultivation of the rice-barley double cropping system, the highest GHG emission by evaluated close-static chamber method was observed from the soil incorporation of barley straw with 387 and $1.0kg\;ha^{-1}$ of $CH_4$ and $N_2O$, respectively. The GHGs emissions from the barley straw burning and off-field usage treatments were 233 and $160kg\;ha^{-1}$ for $CH_4$ and 0.80 and $0.79kg\;ha^{-1}$ for $N_2O$, respectively. The barley straw burning treatment showed the greatest GHGs emission among barley straw management practices in rice-barley double cropping system when considering GHGs emissions both during burning and from paddy fields during the cropping seasons. As a result, the GHGs emissions recorded in the barley straw incorporation to soil and off-field usage treatments were 22.4 and 66.8%, respectively, less than sum of GHGs emissions from the burning of barley straw and from paddy fields during rice cultivation.

Clinic Analysis of Heart Surgery -110 cases- (심장수술 110례 임상고찰)

  • Chang, Hoon;Shin, Sung-Aia;No, Joong-Kee;Rho, Jun-Ryang
    • Journal of Chest Surgery
    • /
    • v.34 no.8
    • /
    • pp.597-603
    • /
    • 2001
  • Background: The purpose of writing this article is to get better clinical results and further clinical improvement based on subject to 110 cases of cardiac surgery which were performed and clinically analyzed. Material and Method: Since January 1995, the patent ductus arteriosus surgery had started in our hospital. In February 1999, an open heart surgery had started and up to September 2000, total of 110 cases were performed as of double ligation of patent ductus arteriosus(10 cases) and open heart surgery(100 cases). Result: Among the patients, Korean-Chines was 74(67.3%) and Han-Chinese was 35(31.8%). Congenital heart disease was 95 cases and acquired valvular heart disease was 15 cases. 83 cases of acyanotic congenital heart disease consisted of ventricular septal defect(VSD) with associated anomaly(45 cases), atrial septal defect(ASD) with associated anomaly(20 cases), patent ductus arteriosus(PDA) with associated anomaly(11 cases), cogenital aortic stenosis(5 cases), double chamber right ventrical(1 case) and Ebstein's anomaly(1 case). Among the 12 cases of cyanotic congenital heart disease, 11 cases of tetralogy of Fallot underwent total correction. Among the 15 cases of acquired valvular heart disease, valvular replacement(7 cases), double valve replacement (3 cases), mitral valve replacement(3 cases) and aortic valve replacement(1 case) were performed. And 8 cases of valvuloplasty were performed by using of commissurotomy, chordal plasty, plasty of papillary muscle, ring type annuloplasty, repair of leaflet. Conclusion: on cogenital heart disease, short term results of surgery for acyanotic cogenital heart disease was good. Among the cyanotic congenital heart disease, tetralogy of Fallot showed a little difference of recovery according to the surgery method so that further follow up observation was needed for long term result. On acquired valvular heart disease, especially, in terms of short term result of valvuloplasty, was relatively good, but further follow up observation was also needed for long term result. There wasn's any operative mortality.

  • PDF

Effects of Different Day / Night Temperature Regimes on Growth and Clove Development in Cool-type Garlic (Allium sativum L.) (한지형 마늘의 생육 및 인편 발달에 미치는 주야간 온도의 영향)

  • Oh, Soonja;Moon, Kyung Hwan;Koh, Seok Chan
    • Horticultural Science & Technology
    • /
    • v.35 no.1
    • /
    • pp.1-10
    • /
    • 2017
  • We investigated growth, clove development, and photosystem II activity in garlic (Allium sativum L.) grown under different day/night temperature regimes using Soil-Plant-Atmosphere - Research (SPAR) chambers to determine the optimum cultivation temperature and to assess the impact of temperature stress on garlic. In the early stages of growth, plant growth increased markedly with temperature. At harvest time, however, the pseudostem diameter decreased significantly under a relatively low day/night temperature range ($14/10-17/12^{\circ}C$), suggesting that these temperature conditions favor regular bulb growth. At harvest time, the bulb diameter and height were great at $14/10-23/18^{\circ}C$, whereas the bulb fresh weight and number of cloves per bulb were greatest at $17/12-20/15^{\circ}C$. However, the number of regularly developed cloves per bulb was highest at the relatively low temperature range of $14/10-17/12^{\circ}C$, as were the clove length and fresh weight. The photochemical efficiency ($F_v/F_m$) and potential photochemical efficiency ($F_v/F_o$) of photosystem II in the leaves of garlic plants were higher at $14/10-20/15^{\circ}C$ and lower at temperatures below $14/10^{\circ}C$ or above $20/15^{\circ}C$, implying that the $14/10-20/15^{\circ}C$ temperature range is favorable, whereas temperatures outside this range are stressful for garlic growth. Furthermore, at temperatures above $20/15^{\circ}C$, secondary growth of garlic, defined as lateral bud differentiation into secondary plants, continuous growth of the cloves of the primary plants, or the growth of bulbil buds into secondary plants, was enhanced. Therefore, to achieve commercial production of fresh scapes and bulbs of garlic, it may be better to grow garlic at relatively low temperature ranges of $14/10-17/12^{\circ}C$.

Geochemical Studies of the Trace Element of the Basalt in the Kilauea, Hawaii (킬라우에아 현무암의 미량원소에 대한 지구화학적 연구)

  • Park, Byeong-Jun;Jang, Yun-Deuk;Kwon, Suk-Bom;Kim, Jeong-Jin
    • Economic and Environmental Geology
    • /
    • v.40 no.5
    • /
    • pp.675-689
    • /
    • 2007
  • Kilauea volcano's summit area was formed by continuous ind/or sporadic eruption activities for several hundreds years. In this study, we mainly focused on the trace elements characteristics through systematic sample rocks erupted from 1790 to September of 1982. Under the microscope it can be observed some main minerals such as olivine, clinopyroxene. and plagioclase with minor opaque minerals including Cr-spinel and ilmenite. Zr, V, Y, Ti elements show incompatible activities with MgO while Ni, Cr, Co elements show highly compatible properties. Elements like as Ba, Rb, Th, Sr, Nd are highly incompatible to show positive trends with $K_2O$. In the REE diagram LREE is more enriched than HREE suggesting typical Oceanic Island Basalt(OIB) type. It can be suggested that Sr have an effect on the fractionation of plagioclase from the kink in the $K_2O$ variation diagram. Y/Ho ratio diagram shows there was no fluids effect in the historical Kilauea volcano but Zr/Hf ratio diagram shows a significant difference between Kilauea lavas and PuuOo lavas. There are distinctive changes of trace element contents showing in particular abrupt changes of temporal variations between 1924 and 1954. Moreover, PuuOo lavas which had been erupted since 1983 follow these decreasing trends of trace element variation. Therefore, it is strongly suggested that these abrupt changes of trace elements trends result from the huge collapse geological event which formed Halemaumau crater in 1924 causing contamination effects of crustal contents into magma chamber and from the changes of parental magma composition injected into Kilauea volcano's summit magma reservoir.

Changes in Quality Characteristics of Venison Jerky Manufactured under Different Dry Time during Storage (건조시간을 달리하여 제조한 사슴고기 육포의 저장 중 품질 특성 변화)

  • Kim Il-Suk;Jin Sang-Keun;Park Ki-Hoon;Kim Dong-Hoon;Hah Kyung-Hee;Park Seok-Tae;Kwuak Kyung-Rak;Park Jung-Kwon;Kang Yang-Su
    • Food Science of Animal Resources
    • /
    • v.26 no.2
    • /
    • pp.166-174
    • /
    • 2006
  • To determine the proper processing and storage conditions, physico-chemical, microbial and sensory properties of venison jerky under different dry times were measured during storage at $30^{\circ}C$ for 28 days. Samples were dried for 3 hr (T1), 4 hr (T2) and 5 hr (T3) at $75^{\circ}C$ in the smoke chamber, respectively. The pH of T1 was slightly lower than those of T2 and T3 as storage time increased. As dry and storage time increased, TBARS of T2 and T3 were significantly higher (p<0.05) than that of T1. In meat color, $L^*$ values of T3 showed slightly higher than those of T1 and T2, while at values were not clearly tendency by the passage of storage time. $b^*$ values of T2 and T3 were higher than that of T1. The water activity were significantly lower (p<0.05) in ,the order of T3$log_{10}$ CFU/g until 28 days and its number were accepted by sensory evaluation. In conclusions, T2 and T3 showed slightly high overall acceptability and lipid oxidative stability compared to T1 conditions. These results indicated that longer dry time ($4{\sim}5 hr$) of venison jerky would be better characteristics as compared to shorter dry time (3 hr) with increased storage time at $30^{\circ}C$.

The Effect of Cutting Positions and Temperature on the Rooting of Bitter Gourd (여주 삽목 시 삽수절단 위치와 온도조건이 발근에 미치는 영향)

  • Lee, Hee Ju;Lee, Sang Gyu;Kim, Sung Kyeom;Choi, Chang Sun;Kim, Sang Beom
    • Journal of Bio-Environment Control
    • /
    • v.25 no.3
    • /
    • pp.162-167
    • /
    • 2016
  • This study was carried out to investigate proper stem cutting position and air temperature to regenerate roots from cuttings of bitter gourd. 'NS454' (NS) and 'Dragon' (DR) cultivars were tested and the cutting position was cut at the 3rd node in the stem (treatment I) and cut at the central part (stem segment) between 3rd leaf and 4th leaf in the stem (treatment II). The air temperature was maintained at 18, 23, 28 and $35^{\circ}C$ in the growth chambers, respectively. The photosynthetic photon flux at the ground of a chamber was maintained in approximately $150-200{\mu}mol\;m^{-2}s^{-1}$ during the 16-hour photoperiod. The relative humidity in the chambers was maintained over 85%. After 10 days of cuttings, regardless of cutting position, DR and NS cultivars showed 100% the survival rate in the $18^{\circ}C$ or $23^{\circ}C$ treatments, however, most of plants $18^{\circ}C$ treatment had not rooting. In the $28^{\circ}C$ treatment, regardless of cutting position, DR and NS cultivars showed 100% of the rooting rate. In the $23^{\circ}C$ treatment, for DR cultivar, the node cutting showed 90% of rooting rate and the stem segment cutting showed 40% rooting rate. For NS cultivar, the node cutting showed 50% of rooting rate and the stem segment cutting showed 40% rooting rate. DR and NS cultivars have high rooting rate, while the rooting rate remarkably decreased in the $35^{\circ}C$ treatment. For DR cultivar, the stem segment cutting showed 5.3 of the highest rooting number and the node cutting showed 2.7 rooting number in the $28^{\circ}C$ treatment. NS cultivar was not significantly different the rooting regardless of cutting position. The results suggested that cutting at the stem segment cutting of bitter gourd is an effective cutting method for increasing survival rate and the air temperature should be maintained at $28^{\circ}C$.

Carbon Fiber as Material for Radiation Fixation on Device : A comparative study with acrylic (고정기구 재질로써 탄소 섬유와 아크릴의 방사선량 감쇄 영향 비교)

  • Chie, Eui-Kyu;Park, Jang-Pil;Huh, Soon-Nyung;Hong, Se-Mie;Park, Suk-Won;Kim, In-Ah;Wu, Hong-Gyun;Kim, Jae-Sung;Kang, Wee-Saing;Kim, Il-Han;Ha, Sung-Whan;Park, Charn-Il
    • Journal of Radiation Protection and Research
    • /
    • v.30 no.1
    • /
    • pp.1-7
    • /
    • 2005
  • Radiation absorption parameters of carbon fiber panel were measured in comparison to acrylic panel. $30{\times}30cm$ sized 2mm thick carbon fiber panel and identical sized 6mm thick acrylic panel were placed in tray holder position and 0cm, 5cm, 10cm from surface of phantom. Radiation field size was $10{\times}10cm$. 50MU of 4MV photon was irradiated to the phantom with dose rate of 300MU/min. Source-to-phantom distance was 120cm. Radiation dose was measured with 0.6cc Farmer-type ionization chamber with 1cm build-up. Measurement was repeated thrice and normalization was done to the dose of the open field. Radiation transmission rate of carbon fiber panel is approximately 1% lower than acrylic panel of equivalent thickness. However, considering the strength of the material, transmission rate is higher for carbon fiber panel. Although carbon fiber panel increases the radiation dose when attached to the surface for about 2%, it normalizes the radiation dose to 97-99% of irradiated dose which could have been lowered to as much as 5-7.5% with acrylic panel. As carbon fiber panel is stronger than acrylic panel, radiation fixation device could be made thinner and thus lighter and furthermore, with increased radiation transmission. This in turn makes carbon fiber more ideal material for radiation fixation device over conventionally used acrylic.

Usefuless of Multi-functional Gastroduodenal Coil Catheter with Phantom (팬텀을 이용한 다기능 위.십이지장관 코일 카테타의 유용성 평가)

  • Lim, Jin-Oh;Kim, Tae-Hyung;Jung, Yang-Hwa;Choi, Won-Chan;Shin, Ji-Hoon;Song, Ho-Young
    • Journal of radiological science and technology
    • /
    • v.26 no.4
    • /
    • pp.21-26
    • /
    • 2003
  • To evaluate the newly designed gastroduodenal coil catheter:in-vitro test. The coil catheter that we made in our laboratory was 150 cm. The coil that is made of stainless steel wire was composed 1.3 mm inner diameter and this coil spring was covered with heat-shrinkable polyethylene tube. To measure the length under fluorocopy, 8 radiopaque marks were attached at 5 cm, 10 cm, 11 cm, 12 cm, 13 cm, 14 cm, 15 cm, 20 cm apart from distal end of the catheter and 6, 2, 1 pores were made at 7 cm, 13 cm, 19 cm apart from the distal end. Radio-opacity and the amount of injected contrast was investigated in formerly used 5 Fr. vessel catheter, which is possible in measuring length, and newly designed coil catheter. Film density was tested for radio-opacity with autodensitometer. For measuring the volume of injected salin, the catheter was located in the acryl box(26 cm, 3 cm, 16 cm) that divided into 4 chambers. After injection 50 cc of contrast with autoinjector, the contrast's quantity in each chamber was measured with and without over the guide wire. Radio-opacity was 0.51 in 5 Fr. vessel catheter, 0.31 in newly made catheter. The amount of injected contrast was measured. In case of 5 Fr. vessel catheter, the amount was 99.5% from the distal part, there was no difference between with and without the guide wire. Otherwise, using a coil catheter, the pacentage the ejected saline was 1.17%, 18.8%, 41.8%, 38.2% from the distal part with the guide wire, 19.5%, 32.6%, 27.7%, 20.3% without the guide wire. Compare with formerly established catheter, this new coil catheter is easy to measure the length thanks to easy confirming under fluoroscopy and excellent in injecting contrast. Therefore, newly designed gastrointestinal catheter seems to be useful in gastrointestinal intervention procedure.

  • PDF