• 제목/요약/키워드: Waste Factors

검색결과 752건 처리시간 0.025초

비정형 공정부산물 In-Situ 감마선 측정 정확도 향상을 위한 효율교정 모델 최적화 방법 개발 (Development of an Efficiency Calibration Model Optimization Method for Improving In-Situ Gamma-Ray Measurement for Non-Standard NORM Residues)

  • 최우철;전태훈;송정호;김광표
    • 방사선산업학회지
    • /
    • 제17권4호
    • /
    • pp.471-479
    • /
    • 2023
  • In In-situ radioactivity measurement techniques, efficiency calibration models use predefined models to simulate a sample's geometry and radioactivity distribution. However, simplified efficiency calibration models lead to uncertainties in the efficiency curves, which in turn affect the radioactivity concentration results. This study aims to develop an efficiency calibration optimization methodology to improve the accuracy of in-situ gamma radiation measurements for byproducts from industrial facilities. To accomplish the objective, a drive mechanism for rotational measurement of an byproduct simulator and a sample was constructed. Using ISOCS, an efficiency calibration model of the designed object was generated. Then, the sensitivity analysis of the efficiency calibration model was performed, and the efficiency curve of the efficiency calibration model was optimized using the sensitivity analysis results. Finally, the radiation concentration of the simulated subject was estimated, compared, and evaluated with the designed certification value. For the sensitivity assessment of the influencing factors of the efficiency calibration model, the ISOCS Uncertainty Estimator was used for the horizontal and vertical size and density of the measured object. The standard deviation of the measurement efficiency as a function of the longitudinal size and density of the efficiency calibration model decreased with increasing energy region. When using the optimized efficiency calibration model, the measurement efficiency using IUE was improved compared to the measurement efficiency using ISOCS at the energy of 228Ac (911 keV) for the nuclide under analysis. Using the ISOCS efficiency calibration method, the difference between the measured radiation concentration and the design value for each simulated subject measurement direction was 4.1% (1% to 10%) on average. The difference between the estimated radioactivity concentration and the design value was 3.6% (1~8%) on average when using the ISOCS IUE efficiency calibration method, which was closer to the design value than the efficiency calibration method using ISOCS. In other words, the estimated radioactivity concentration using the optimized efficiency curve was similar to the designed radioactivity concentration. The results of this study can be utilized as the main basis for the development of regulatory technologies for the treatment and disposal of waste generated during the operation, maintenance, and facility replacement of domestic byproduct generation facilities.

The volcanic aspect on determining Site of nuclear power plant in Indonesia: Gap analysis between standard and regulations

  • Widjanarko;Budi Santoso;Rismiyanto;Kurnia Anzhar;Joko Waluyo;Gustini H. Sayid;Khusnul Khotimah;Nicholas Bertony Saputra;Agus Teguh Pranoto;Hadi Suntoko;Siti Alimah;Sriyana;Roni Cahya Ciputra;Alfitri Meliana
    • Nuclear Engineering and Technology
    • /
    • 제56권7호
    • /
    • pp.2875-2880
    • /
    • 2024
  • The development of nuclear power plants is in three phases. The first phase is a consideration before the decision on the NPP construction program is approved, the second phase is the preparatory work for making contracts and preparing for the construction of NPP after the NPP construction policy is approved, and the third phase is contracting, licensing and building the first NPP. As a volcanically active country, Indonesia contains over 130 active volcanoes that are part of the Pacific Ring of Fire. The volcanic aspect is one of the safety factors considered while deciding the location of an NPP. Research on the potential of natural external risks to the determination of nuclear power plants in Indonesia, including the volcanic aspect, has been conducted based on the safety reference or safety guide of the IAEA and the Nuclear Energy Regulatory Body (BAPETEN) Regulation. Due to technological advancements, safety needs have evolved so the existing Indonesia National Standard (SNI) must be updated to comply with BAPETEN regulations. The substance in SNI 18-2034-1990 relating to volcanic features seems less relevant in actual conditions, given that more complete and exact criteria for determining a site guarantee the safety and health of residents and surrounding the environment site. The study intends to conduct a gap analysis of volcanic issues in SNI and volcanic regulations. The method used is identification requirements for volcanic aspects in SNI 18-2034-1990 about Determining Site of Nuclear Reactor Guidance with BAPETEN Chairman Regulation (BCR) number 4 of 2018 about Nuclear Installation Site Evaluation Safety Provisions and BCR number 5 of 2015 about Evaluation of Nuclear Installation Sites for Volcanic Aspects, and analysis uses a qualitative method of inductive techniques. The outcome of this research applies to suggesting a revision of SNI number 18-2034-1990, especially the volcanic aspect.

漢江 水質保全 行政에 관한 硏究 (A Study on the Administration for the Han River Water Quality Control)

  • Kim, Kwang Hyop
    • 한국환경보건학회지
    • /
    • 제10권2호
    • /
    • pp.9-40
    • /
    • 1984
  • This thesis purports to overview the diverse administrative and organizational factors and plannings developed by the government organizations, municipal or otherwise, to tackle the Han River water pollution issues in the past years. This thesis also looks into the ever-worsening Han River water pollution problems, in particular, in terms of the various government plans ostensibly designed to reduce the pollution level but with little success. Also dealt with are the efficiencies with which the laws and decrees on water pollution the administrative organizations put to use in the prosecution of the diverse antiwater pollution projects involving the Han River basin. From the early 1960's up to the 1970's the government had concentrated on the growth-oriented economic policy with the result that little attention had been paid to the water pollution and other environmental issues that are bound to arise from the massive economic growth. Belatedly, the five-year Hah River Development Project was initiated in 1982 with emphasis on reducing the water pollution level at Hah River to the minimum. The following are the gists of the thesis and recommendations for the future antiwater pollution plans by the administrative organizations: 1. Documents to date indicate that the irrigation projects along the Han River area had been the main focus of attention during the Yi Dynasty and under the Japanese rule of the country. 2. Despite that the water pollution issue became the subject of many debates among the academic and research institutions in the 1960's and in the 1970's, the administrative organizations in charge of the Han River water quality control failed to come up with a concrete plan for the river's water quality control. 3. Nevertheless, the water pollution of the Han River area in fact began in the 1950's, with the unprecedented concentration into Seoul of population and the industrial facilities on a larger scale, in particular, enforced by the government's strong growthoriented policy in its Economic Development plans in the 1960's. 4. Starting in the 1960's, the Han River water pollution level dramatically increased, but the government was reluctant to promulgate or put into effect strong measures to curb the many factors contributing to the river water pollution, thus worsening the environmental issues along the Han River basin. 5. The environmental protection law and other laws and decrees relating to the antiwater and air pollution issues that were subsequently put into effect underwent so many changes that efficient anti-water pollution policies could not be effected for the Han River basin. The frequent organizational reshuffle within the administrative units concerned with environmental problems has resulted in the undue waste in personnel management and finance. 6. The administration on the environmental protection could not be efficiently carried out due to the organizational overlapping. Under the existing law, frequent organizational frictions and inefficiency are bound to occur among the central government offices themselves, as well as between the central government and the Seoul city administration, and among the city's administrative offices over the conservation of the Han River basin and over the river's anti-water pollution issue. 7. In the planning and prosecution of the Han River project, political influences from the president down to the lower-level politicious appear to have been involved. These political influences in the past had certainly had negative influence on the project, nevertheless, it appears that in the recent years, these political influences are not all that negative in view of the fact that they serve as a positive contributing factor in developing a better water quality control project along the Han River basin. The following are a few recommendations based on the data from the thesis: First, officials in charge of the Han River water quality control should pay attention to a careful screening of the opinions and recommendations from the academic circles and from the public should be made so that the government could better grasp the core issues in the environmental problems that require preventive and other necessary measures. Second, vigorous redistribution policies of population and industrial facilities away from the Seoul area should be pursued. Third, the government should refrain from revising or revamping too frequently the laws and decrees on the anti-water pollution, which is feared to cause undue inconveniences in the environmental administration. Fourth, a large-scale streamlining should be made to the existing administrative organization in an effort to do away with the inter- and intra-organizational friction. It is recommended that a secretariat for the Hah River basis conservation be established. Fifth, High-level administrative officials, with a thorough knowledge and vision on the Han River water quality control, should be prepared to better deal with the budgeting and personnel management for the Han River water pollution control not only at the control government, but also at the Seoul city municipal government levels. Environmental issues should be kept distinct from political issues. Environmental issues should not serve as a window-dressing for sheer political purposes. Sixth, the Hah River proiect should also include, along with the main Han River basin, those areas covering North Han River, South Han River, and the tributaries to the main river basin. The 'Han River Basin Water Quality Control Board' should be established immediately as a means of strengthening the current Han River basin water quality control policy. Seventh, in drawing up the Han River proiect, the administrative officials should be aware that Han River basin is a life line for those people in the region, providing them with not only a sheer physical space, but with a psychological living space for their everyday life.

  • PDF

옥천천 (만) 유역 하천과 만입부의 수환경 평가 (An Evaluation of Aquatic Environment in the Okchon Stream-Embayment Watershed, Korea)

  • 김동섭;이혜근;맹승진;황순진;신재기
    • 생태와환경
    • /
    • 제36권2호통권103호
    • /
    • pp.181-190
    • /
    • 2003
  • 옥천천(만)유역을 대상으로 2002년 5월부터 9월까지 총 6회 수환경을 조사하였다. 환경 요인은 하천과 구간에 따라 차이가 컸고, 유수환경과 정수환경에서 더욱 현저하여 대비가 되었다. 수중 영양염은 상류 하천에서 비교적 저농도이었으나, 하수처리수 유입 후부터 고농도로 전환되어 점오염원 영향이 절대적이었다. 특히, 유역에서 SRP와 $NH_4$의 분포는 다른 영양염에 비해 매우 뚜렷하였고, 하수처리수의 영향을 평가함에 있어 가장 중요한 인자가 될 수 있었다. 하수처리수의 유입직 후 정점에서 SRP의 평균 농도는 919.3${\mu}g$ P/l로써 유역에서 가장 영향력이 컸고, P농도에 의해 수중 영양염 비율이 조절됨을 알 수 있었다. 하수처리수의 지속적 공급은 하류의 만입부에서 chl-a 증가를 유도하는 결정적인 요인으로 볼 수 있었다. 남조류가 대발생한 시기에 만입부에서chl-a 농도는 234.5${\sim}$l,692.2 ${\mu}g$/1범위이었고, 8월에 최대 현존량은 ml당 $1.0{\times}10^6$ 세포를 훨씬 초과하여 담수적조 수준보다 200배 이상이었다. 이러한 결과는 다른 환경요인에서 잘 반영되었고, 그 중에서 AFDM/TSS 비는 100%로써 조류에 의한 수질오염이 극심함을 잘 반영하였다. 따라서, 하수처리수에 포함된 P와 N 저감이 선행되어야 하천 수환경 개선 뿐만 아니라 저수지 수질관리에 효과가 있을 것으로 본다.

방사선사의 병원감염관리에 대한 연구 (A Study on Hospital Infection Management of Radiological Technologist)

  • 정봉재
    • 한국방사선학회논문지
    • /
    • 제12권6호
    • /
    • pp.727-735
    • /
    • 2018
  • 본 연구는 경남지역에 근무하는 방사선사를 대상으로 병원감염관리에 대한 특성과 인지도 및 수행도를 분석하여 병원근무 시 감염관리에 대한 올바른 인식과 수행 능력을 향상하고, 병원감염관리의 개선 및 방사선사의 감염관리 교육을 위한 기초자료를 얻고자 실시하였다. 연구에 사용한 도구는 설문지로 2018년 04월01일부터 04월30일까지 경남에 소재하는 의료기관에 근무하는 방사선사를 대상으로 설문지 총400부를 배부하여 연구에 적합한 320부를 SPSS 18.0 통계 프로그램을 이용하여 분석하였다. 병원감염관리에 대한 요인으로는 병원감염에 관한 특성 5문항과 병원감염관리에 대한 인지도와 수행도로 손위생관리, 개인위생 및 의복관리, 의료기구 및 소모품관리, 청소 및 폐기물관리, 검사실 및 환경관리 등, 총60문항으로 분석하였다. 인구사회학적특성으로 성별, 결혼, 연령, 학력, 근무기관, 근무경력, 근무부서를 기준으로 기술통계, t-test, ANOVA, 상관관계 및 회귀분석을 하였다. 병원감염관리에 대한 인지도는 $4.19{\pm}.60$점으로 높게 나타났으며, 수행도에서도 $4.22{\pm}.52$점으로 높게 나타나 병원감염관리에 대한 인지도와 수행도에서 경남지역 방사선사들의 병원감염관리 수준은 높은 것으로 분석되었다. 병원감염관리에 대한 방사선사의 인지도 및 수행도는 유의한 상관관계가 있는 것으로 나타났으며, 인지요인이 수행도에 미치는 영향에 대한 다중회귀분석에서는 66.1%의 설명력과 함께 유의한 양의 영향력을 미치고 있음을 알 수 있었다. 의료기관 다양한 부서에서 근무하는 방사선사의 병원감염관리에 대한 인식을 높이기 위해서는 지속적인 감염관리교육과 더불어 병원업무 환경개선을 통한 수행능력을 향상시켜야 하며, 병원감염관리 및 예방교육에 적극적으로 참여하여 병원감염관리 업무에 대한 전문성 확보와 함께 중추적인 역할을 수행하여야 할 것으로 판단된다.

인천국제공항 식재기반 구조 및 토양특성 연구 (A Study on the Structure Characteristics of Planting Ground in Incheon International Airport, Korea)

  • 이승원;한봉호;이경재;곽정인;염정헌
    • 한국조경학회지
    • /
    • 제43권3호
    • /
    • pp.77-91
    • /
    • 2015
  • 본 연구는 대규모 매립지에 조성된 인천국제공항을 대상으로 수목 식재기반에 대한 구조적, 이화학적 특성을 파악함으로써 합리적인 토양관리 방향을 제시하고자 하였다. 세부 연구 대상지는 국제업무단지, 여객터미널, 공항지원단지, 자유무역지역, 진입도로 등 5개소이었다. 인천국제공항 수목생육 기반에 대한 토양 구조분석결과 표토로부터 80cm 이내에 경반층 또는 이질층의 토양층위가 존재하는 조사구는 총 27개소 중 9개소이었으며, 성토재료로 자갈 매립(4개소), 준설토와 혼합된 재료 매립(2개소), 점토가 다량 포함되어 투수가 불량한 성토 재료 사용(3개소), 폐골재를 매립한 경우(1개소) 등이었다. 토양의 물리적 특성으로 토양경도는 성토층 평균 $11.5kg/cm^2$이었고, 토성은 모래함량이 많은 사토, 사양토, 양질사토 등이었다. 화학적 특성으로서 토양산도는 성토층 평균 pH 6.7이었으며, 유기물함량은 0.7%, 전기전도도(EC)는 0.0dS/m, 교환성양이온함량은 $Ca^{2+}$ 3.4cmol/kg, $Mg^{2+}$ 1.5coml/kg, $K^+$ 0.3cmol/kg, $Na^+$ 1.0cmol/kg, 교환성양이온치환용량(CEC)은 11.0cmol/kg이었다. 성토층의 절대적 평균치는 대부분 조경설계기준을 만족하였으나 매립지토양특성상 층위별 조사구별 편차를 반영할 수 없는 한계가 있어 성토층위별로 분석한 교환성양이온별 염기포화도(BSP)는 소성토지역 $Ca^{2+}$ 29.9%, $Mg^{2+}$ 13.3%, $K^+$ 3.7%, 중성토지역 $Ca^{2+}$ 33.3%, $Mg^{2+}$ 17.0%, $K^+$ 2.7%, 대성토지역 $Ca^{2+}$ 32.6%, $Mg^{2+}$ 12.2%, $K^+$ 1.9%이었다. 교환성나트륨백분율(ESP)은 소성토지역 16.4%, 중성토지역 7.5%, 대성토지역 4.7%이었고, 나트륨흡착비(SAR)는 소성토지역 0.8, 중성토지역 0.3, 대성토지역 0.2이었다. 성토재료의 불균질과 불량, 준설토의 교란, 답압에 의한 높은 토양경도와 지중의 경반층형성, 낮은 유효토심 등의 물리적 요인과 높은 pH, 염기밸런스 불균형, 낮은 유기물, 유효인산 등은 식물생육에 영향을 주는 것으로 분석되었다.

Vis/NIR 초분광 분석을 이용한 고춧가루 색도 간이 측정법 개발 (A Simple Method for Evaluation of Pepper Powder Color Using Vis/NIR Hyperspectral System)

  • 한고은;이훈수;강진호;최은아;오세정;이용직;조병관;강병철
    • 원예과학기술지
    • /
    • 제33권3호
    • /
    • pp.403-408
    • /
    • 2015
  • 색도는 고추의 품질을 결정하는 중요한 요인으로, 색도 측정을 위해 high-performance liquid chromatography(HPLC), thin layer chromatography(TLC), ASTA-20 방법 등이 활용되고 있다. 특히 ASTA-20 방법은 간단하고 정확하게 다수의 시료에 대한 색도 분석을 수행할 수 있다는 장점 덕분에 주로 사용된다. 하지만 전처리 과정에 시간이 많이 소요되고 아세톤과 같은 폐시약이 발생한다. 따라서 본 연구에서는 ASTA-20 방법을 대체하기 위하여 Vis/NIR 초분광 분석법을 활용한 빠른 색도 분석법을 개발하고자 하였다. ASTA-20 방법과 Vis/NIR 초분광 분석법의 상관관계를 분석하기 위하여 총 488점 고춧가루의 색도를 두 가지 방법으로 측정하였다. 이후 무작위로 선발한 366개의 시료를 이용하여 Vis/NIR 초분광 분석법으로 측정한 값으로부터 ASTA 값을 예측하는 부분최소자승법(PLS) 모델을 확립하였다. 모델 개발에 활용하지 않은 122개 시료의 ASTA 값을 PLS 모델을 이용하여 예측하고, ASTA-20 방법으로 측정한 값과 비교해본 결과, 매우 유의성 있는 상관관계($R^2=0.88$)를 나타내 Vis/NIR 초분광 분석법의 신뢰도를 확인할 수 있었다. 따라서 본 연구에서 개발한 간편하고 빠른 ASTA 값 측정 방법은 전처리 단계를 요구하지 않고, 30분 이내에 100개 시료에 대한 분석을 수행할 수 있어 다수의 고춧가루 색도를 빠르게 측정하는데 유용하게 사용될 것으로 기대한다.

일부 농촌지역의 결핵 치료 환자에 대한 실태 조사에 관한 연구

  • 이재희
    • 대한간호학회지
    • /
    • 제1권1호
    • /
    • pp.85-94
    • /
    • 1970
  • This is a study of 21 tuberculosis patients receiving medical treatment at the Public Health Center in Kyongi Do, Pu Chun Gun and at the General Hospital. The results cover the findings of the period from May, 1969 to November 1970. The information obtained is based on personal interviews with the patients, and symptomatic diagnosis made from observations. The following statistics when not equalling 100% contain only the responses of the two extremes in each case. The findings of the research are as follows: 1. 52.3% of the patients in the study are males and 47.7% are females. 28.6% of the subjects are between 20 and 29 years of age and an equal percent are between 30 and 39 years. 2. 47.5% of the subjects had graduated from primary school, while only 4.8% had graduated from high school. 3. 57.1% of the patients said they had no religions beliefs, while 4.8% professed to being Buddhists or believing in superstition. 4. 47.3% of the people said they were unemployed, while 4.8% classified themselves as labourers. 5. In response to how tuberculosis was first detected in their respective cases, 52.6% became aware of their disease through X-ray results, while 4.8% were discovered to have tuberculosis when being treated for other diseases at the hospital. 6. When asked how many of the patients knew anything about their disease when treated, 57.1% knew nothing about tuberculosis when they received treatment, while 42.9% had some knowledge of the disease. 7. Of those who knew something about tuberculosis, 61.9% learned about from doctors and nurses, while 4.8% learned from other people. 8. 57.1% of the patients knew that tuberculosis is a communicable disease, while 42.9% did not know. 9. 52.4% of the patients did not know the cause of tuberculosis while 4.9% believed the disease was caused by a curse. 10. When asked about the extent of treatment, 52.4% responded that they had undergone continuous treatment, while 4.8% had not received treatment. 11.The reasons given for not continuing treatment were the following: economic factors 55.6%; side reactions to the treatment, lack of knowledge of how to get treatment, of the need for treatment, or of the positive effects of treatment 11.1%. 12. 61.9% of the subjects usually took the medical treatment at home, 9.5% took it in the mountains or at the beach. 13. 42.9% of the patients received drugs for treatment at the local public health center, while 4.8% received them at the hospital 14. 33.3% of the patients received P.A.S+I.N.H.+S.M. for treatment of tuberculosis, while 4.8% received P.A.S.+S.M.. and some secondary drug. 15. Of the patients who took some extra medicine for tuberculosis, 38.1% took a Chinese drug, while 9.5% took herb medicine. 16. 38.1% of the patients had continued treatment for three years, 4.8% had interrupted the treatment. 17. When asked about the development of the disease after treatment, the patients gave the following information: after one month, 90.5% thought the treatment helped, while 9.5% weren't sure; after one year, 55.6% thought it was good, while 5.5% thought it was not; after three years, 63.6% had a very bad condition. while 4.8% didn't know. 18. 61.9% of the patients were unconcerned about covering their mouths when they coughed, while 38.1% covered their mouths. 19. 57.2% were unconcerned they spit, while 23.8% spit into a waste basket. 20. 66.7% were unconcerned about sterilizing tableware, while 9.5% handled it separately. 21. 66.7% were unconcerned about ventilating their room, while 9.5% ventilated the room twice a week.

  • PDF

생활하수가 유입된 산지하천(대천천)의 유기물 및 무기영양염의 동태 (Dynamics of Organic Matter and Inorganic Nutrients in a Over-enriched Mountain Stream due to Anthropogenic Loading)

  • 박정임;김영균;정미희;송미영;이상호;전태수;이근섭
    • 환경생물
    • /
    • 제24권3호
    • /
    • pp.230-239
    • /
    • 2006
  • 본 연구는 2002년 1월부터 2003년 5월까지 오염원이 비교적 단순한 산지하천에서의 무기 영양염 및 유기물 변동을 고찰하기 위해 낙동강 지류인 대천천의 상류에서 실시되었다. 조사지점은 인위적인 오염이 없는 DC1, 주위의 식당과 민가에서 생활하수가 유입되는 DC2, DC3, DC4그리고 부분적으로 수질이 자연 정화된 DC5이다. 전기전도도, 탁도, BOD는 하수의 유입으로 인하여 DC2에서 급격히 증가하였다가 DC5에서 다시 낮아졌다. 수층의 $NH_4^+$$PO_4^{3-}$농도는 갈수기인 겨울에 증가하는 경향이 보였으며, DC2에서 DC1에 비해 각각 150 배 및 37배가 증가하였다가 하류로 내려 갈수록 뚜렷하게 감소하였으며, $NO_3^-+NO_2^-$은 오염지역인 DC2, DC3, DC4와 DC5에서 청정지역인 DC1보다 약 2배 증가하였다. N/P비율은 DC1에서 가장 높았고, 하수 유입지역에서 감소하여 이들 지역에는 부영양화가 진행되고 있음을 알 수 있었다. 퇴적물 공극수의 $PO_4^{3-}$농도는 겨울과 봄에 증가하였으나, $NH_4^+$$NO_3^-+NO_2^-$의 농도는 계절 경향이 보이지 않았다. 퇴적물 공극수의 $NO_4^-,\;PO_4^{3-}$ 농도와 퇴적물의 유기물 함유량도 하수가 유입되는 DC2, DC3, DC4에서 유의하게 증가하였고, DC5에서 다소 감소하였다. 퇴적물 공극수의 $NO_3^-+NO_2^-$의 농도는 DC2에서보다 용존산소가 풍부한 DC5에서 오히려 증가하였다. 수층의 TOC와 DOC농도는 봄과 가을에 증가하였고, 하수가 유입되는 지역에서 높게 측정되었다. 조사지역이 산지하천의 상류에 위치하고 있으나 식당 및 민가에서 유입되는 생활하수는 하천의 상류를 부영양화 시켰으며, 하류로 내려오면서 유기물 및 무기 영양염의 농도가 감소하여 하천수가 자연적으로 정화되는 것이 관찰되었다.

난지도 지역의 대기수은 지화학 (Geochemistry of Total Gaseous Mercury in Nan-Ji-Do, Seoul, Korea)

  • 김민영;이강웅;신재영;김기현
    • 한국지구과학회지
    • /
    • 제21권5호
    • /
    • pp.611-622
    • /
    • 2000
  • 대규모 면오염원으로 간주되는 난지도지역을 중심으로 2000년 봄 기간중 대기-지표간 수은의 교환율을 측정하고, 측정자료를 기초로 수은의 교환현상을 분석하였다. 측정결과에 의하면 난지도지역은 대규모 면오염원으로 대량의 수은을 배출할 뿐아니라 동시에 대규모의 침적을 경험하는 것으로 나타났다. 일주기별로 농도, 농도구배, 플럭스의 절대치를 분석한 결과 대규모 배출과 침적은 오후시간대에 왕성하게 진행되는 것으로 나타났다. 그러나 이들의 발생빈도에 대한 분석결과는 배출이 새벽 또는 저녁에 빈번하게 발생하는데 비해, 침적은 주로 오후시간대에 집중된다는 것을 확인하였다. 풍향대별로 발생빈도와 교환율을 비교한 바에 따르면, 대규모 침적을 유도하는 외부배출원이 동쪽지역에 위치해 있다는 것을 추정할 수 있었다. 특정 풍향에서 침적이 집중된 점을 감안하여, 침적이 집중된 방향의 자료군과 배출이 지배적으로 발견된 전체자료를 이용하여 조건별 환경인자의 변화동향을 배출/침적비로 환산하여 비교하였다. 그 결과 대부분의 오염인자들의 농도는 외부여건에 따라 규칙적인 변화양상을 보여주었다. 상관분석의 결과는 이들의 거동이 교환현상의 수직적인 방향-침적 또는 배출-의영향을 민감하게 반영하는 것으로 나타났다. 요인분석의 결과는 배출시에 기온과 같은 요인에 의해 유도되는 부분이 그리고 침적시에는 기온, 오존, 비메탄계 탄화수소와 같이 외부인자의 영향을 반영하는 요인들이 복합적으로 중요하게 작용할 수 있다는 점을 시사하였다. 난지도지역을 중심으로 한 수은의 자료를 추정한 결과 연간규모로 약 6kg의 수은이 배출되는 것으로 나타났다.

  • PDF