• Title/Summary/Keyword: WH

Search Result 857, Processing Time 0.028 seconds

A Detail Survey of Horizontal Global Radiation and Hours of Bright Sunshine for the Installation of Solar Photovoltaic System in Korea (국내 태양광시스템 설치를 위한 수평면 전일사량과 일조시간 정밀조사)

  • Jo, Dok-Ki;Yun, Chang-Yeol;Kim, Kwang-Deuk;Kang, Young-Heack
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.3
    • /
    • pp.48-56
    • /
    • 2011
  • Since the horizontal global radiation and hours of bright sunshine are a main factor for designing photovoltaic system, it is necessary to evaluate its characteristics all over the country. The work presented here are the investigation of horizontal global radiation and hours of bright sunshine in Korea. The data utilized in the investigation consist of horizontal global radiation and hours of bright sunshine collected for 28years(1982.12~2009.12) at measuring stations across the country. The analysis shows that the annual-average daily horizontal global radiation is3.61kWh/m2 and the annual-average daily hours of bright sunshineis 5.1 Hrs in Korea. We also constructed the contour map of hours of horizontal global radiation and hours of bright sunshine in Korea by interpolating actually measured data across the country.

The analysis of the renewable energy supply ratio for the school building applied PV system (PV 시스템이 설치된 대학건물의 전력 생산에 따른 신재생에너지 공급비율 분석)

  • Kang, Su-Hyun;Lee, Yong-Ho;Hwang, Jung-Ha;Cho, Young-Hum
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.2
    • /
    • pp.50-57
    • /
    • 2012
  • Recently the renewable energy has been used widely and the importance of renewable sources is bigger than before. And the government enforced a law to the public buildings to install the renewable energy facilities. The capacity of facilities was 5% of total construction cost until April 13, 2011. Since then, the government changed the law from 5% of total construction cost to 10% of predicted energy usage for the resonable use of the renewable energy facilities. In this study, the comparative analysis is conducted according to the law to the building installed PV system through the Energy Plus simulation. And the method for improving renewable energy supply ratio was analyzed using existing PV array. Adjusting the PV array angle is the best way to generate more electric power without additional fee. When applying the month optimum angle, 3,600kWh of electric power are more generated compared to the existing angle.

A Study on the Generator Operation by the Electronic Consumption During the Summer in a Complex Building Cluster (복합시설의 하절기 전력사용량에 따른 발전기 가동현황 분석)

  • Kwon, Han-Sol;Kong, Dong-Seok;Kwak, Ro-Yeul;Huh, Jung-Ho
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.11a
    • /
    • pp.126-131
    • /
    • 2008
  • The large buildings in Korea usually use the generators to control the peak load of electronic consumption during the summer. It is necessary that these generators emit carbon dioxide, since they use gas or gasoline for their fuel. This study is to analyze the data of electronic consumption and operation of the generators at COEX, one of the representative complex building clusters in Korea, and to compare to the amount of carbon dioxide emitted per 1kWh from the domestic power plant by analogizing the frequency of using the generator during the summer and the amount of fuel consumption by the capacity of the generator and estimating the amount of carbon dioxide emitted from the generator.

  • PDF

Fuzzy optimization for the removal of uranium from mine water using batch electrocoagulation: A case study

  • Choi, Angelo Earvin Sy;Futalan, Cybelle Concepcion Morales;Yee, Jurng-Jae
    • Nuclear Engineering and Technology
    • /
    • v.52 no.7
    • /
    • pp.1471-1480
    • /
    • 2020
  • This research presents a case study on the remediation of a radioactive waste (uranium: U) utilizing a multi-objective fuzzy optimization in an electrocoagulation process for the iron-stainless steel and aluminum-stainless steel anode/cathode systems. The incorporation of the cumulative uncertainty of result, operational cost and energy consumption are essential key elements in determining the feasibility of the developed model equations in satisfying specific maximum contaminant level (MCL) required by stringent environmental regulations worldwide. Pareto-optimal solutions showed that the iron system (0 ㎍/L U: 492 USD/g-U) outperformed the aluminum system (96 ㎍/L U: 747 USD/g-U) in terms of the retained uranium concentration and energy consumption. Thus, the iron system was further carried out in a multi-objective analysis due to its feasibility in satisfying various uranium standard regulatory limits. Based on the 30 ㎍/L MCL, the decision-making process via fuzzy logic showed an overall satisfaction of 6.1% at a treatment time and current density of 101.6 min and 59.9 mA/㎠, respectively. The fuzzy optimal solution reveals the following: uranium concentration - 5 ㎍/L, cumulative uncertainty - 25 ㎍/L, energy consumption - 461.7 kWh/g-U and operational cost based on electricity cost in the United States - 60.0 USD/g-U, South Korea - 55.4 USD/g-U and Finland - 78.5 USD/g-U.

Removal of Toxic Organic Compound using Electro-Fenton Reaction (Electro-Fenton 반응을 이용한 유독성 유기화합물 처리)

  • Park, Sang Won
    • Journal of Environmental Science International
    • /
    • v.13 no.6
    • /
    • pp.551-560
    • /
    • 2004
  • The feasibility and efficiency of the hydrogen peroxide produced by an electrolysis cell reactor was investigated, From regulating voltages for the given reaction time, the concentration of the hydrogen peroxide was gradually increased with increasing voltages. Optimal voltage range was found to be 10~15 V. The concentration of hydrogen peroxide was much higher with oxygen gas than without oxygen gas in the cathodic chamber. But there was a little difference in the generating rate of hydrogen peroxide regardless of the presence of nitrogen gas. Under given conditions, the maximum value of ICE(Instantaneous Current Efficiency) was about 38%, and then current density was 74 $mA/\textrm{cm}^2.$ The specific energy consumption was $0.694[kWh/kg-H_2O_2].$ Since Esp (Specific Energy Consumption)was very little value, It did not demand high energy in this system. Using the hydrogen peroxide gained in the experiment, Fenton's reaction was conducted and the removal of nitrobenzene, 3-chlorophenol and dye wastewater was studied. This results were very similar to the Fenton's reaction by using commercial hydrogen peroxide.

Adjustment of load correlation coefficient for advanced load management (부하관리 개선을 위한 부하 상관계수 산정에 관한 연구)

  • Park, Chang-Ho;Cho, Seong-Soo;Kim, Gi-Hyun;Im, Jin-Soon;Kim, Du-Bong;Kim, Jae-Chul
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1267-1269
    • /
    • 1999
  • This paper studies on arrangement of load correlation coefficient for advanced load management. To accurate load correlation coefficient, we used two real factors, electrical energy(kWh) and peak load current of pole transformers, acquired by measuring instrument. Out of several correlation equations, we find that the quadratic equation is the most accurate to express peak load current and working electrical energy. If the data is located in the outside of ${\pm}3{\sigma}$ it is discarded. For load management, we rearranged load correlation coefficient considering +2${\sigma}$ at load correlation equation. Comparing conventional load correlation coefficient with rearranged one, we can get the result of error reduced and it is adjacent to the actual data. It will be used peak load forecasting from working electrical energy and we are able to prevent from the damaging of pole transformer due to overload.

  • PDF

Atmospheric Chemistry of Mercury in the Polar Regions and its Environmental Implications (극지환경 수은의 대기화학과 환경학적 의미)

  • Schroeder, WH;Kim, Min-Young;Hong, Sung-Min;Shon, Zang-Ho;Kim, Ki-Hyun
    • Journal of the Korean earth science society
    • /
    • v.24 no.5
    • /
    • pp.420-427
    • /
    • 2003
  • The results of recent studies indicate that atmospheric distribution of Hg in the arctic environment is unique enough to show strong depletion during spring followed by notable increases during summer. The observations of this abnormal trend contrast quite sharply with what had been recognized as Hg geochemical behavior in air over the past decades. Using the long-term measurement data of Hg obtained from both the Arctic and Korea, we attempted to provide valuable insights into the unique mercury depletion phenomenon (MDP) in the polar regions of the globe.

Estimation of Human Carcinogenic Potency (HCP) of Carcinogens in Risk Assessment and Management. (위해성 평가 및 관리에 있어서 발암물질의 인체발암능력 평가)

  • 이병무;김대영;김세기;김근종
    • Environmental Mutagens and Carcinogens
    • /
    • v.19 no.1
    • /
    • pp.39-45
    • /
    • 1999
  • Human Carcinogenic Potency (HCP) can be estimated based on human daily exposure dose to carcinogen (Dh), body weight (Wh), 10% tumorigenic dose (TD10), and slope factor at TD10 (Q10) from 2-yr bioassay data. This approach is more relevant to humans generally exposed to low doses of carcinogens and can reduce more of extrapolation errors from high dose in animal experiments to low dose in humans than HERP (human exposure dose/rodent potency dose) proposed by Ames et al. (Science, 236, 271-280, 1987). TD50 and HERP have been routinely used to compare rodent carcinogenic potency and human carcinogenic potency, but those approaches have had limitations in extrapolation of high dose to low dose in humans. The advantages of HCP are to estimate human exposure dose (Dh) by human monitoring instead of environmental monitoring, to consider slope factor (Q10) which reflects the tendency of curve at low dose, and to use TD10 which represents much lower dose thant TD50 or HERP. HCP will be a useful parameter for the estimation of human carcinogenic potency in risk assessment and management of carcinogens.

Heating Energy Consumption Analysis of the Apartment Applied District Heating System (지역난방 공동주택의 단지별 난방사용량 분석 연구)

  • Park, Sun-Hyo;Lee, Hyun-Jung;Kwon, Kyung-Woo;Lee, Byung-Seok;Kim, Yang-Sub
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.293-298
    • /
    • 2012
  • The purpose of this study is performance validation of district heating apartments about heating energy consumption and analysis of energy consumption by unit characteristics. The heating energy consumption of the existing apartments was analyzed and the analyzed results will be used for energy saving technology development and policy making. The heating energy consumption data about total 78 apartment complexes, 56,910 units in Gangnam-Gu, Seoul, Korea were investigated from October, 2010 to April 2011. The analysis results are as follows; The mean heating energy consumption is 98[kWh/m2]. The energy consumption of Apgujung-Dong, Daechi-Dong is higher than that of mean valuse. The energy consumption deviation by deterioration, unit area, core type and regional group is very high. Specially, building deterioration casts a long shadow.

  • PDF

A Study on Learning to Write English Interrogative Sentences

  • Choi, Kyunghee
    • English Language & Literature Teaching
    • /
    • v.18 no.2
    • /
    • pp.21-44
    • /
    • 2012
  • This paper aims to discuss the effects of learning how to write English interrogative sentences. 122 students who participated in the study learned basic structural components of English questions and practiced writing questions by inversing the subject and the verb in a given declarative sentence. The participants were divided into two groups: Group 1 which was given a brief explanation of interrogative structures and practices, and Group 2 which was given the same explanation and practices in addition to an assignment for which they had to make one or two comprehension questions based on reading a passage. For the pre-tests and the post-tests, they took a TOEIC reading test with 40 questions and a structure test with 25 questions. The results of the tests show that both groups improved significantly in the two post-tests, benefiting from this learning method. However, the additional treatment for Group 2 did not seem to be highly effective. In the questionnaire survey, the participants think that the method of learning English questions has helped them better understand English grammar as well as interrogative structures. The participants were also divided into three different levels: high, intermediate, and low. The intermediate level group students benefited most from learning writing questions as the results of the post-test of the 25-questions test and the final exam of the course show.

  • PDF