• Title/Summary/Keyword: V-line

Search Result 2,153, Processing Time 0.039 seconds

Flashover Characteristics of Damaged Insulator Strings for Live-line works in 765kV T/L (765kv 송전선로 활선작업을 위한 불량애자 발생 유형별 전기적 섬락특성 분석)

  • Lee, H.K.;Shon, H.K.;Park, M.Y.;Park, I.P.;Kim, H.J.
    • Proceedings of the KIEE Conference
    • /
    • 2005.05b
    • /
    • pp.31-34
    • /
    • 2005
  • The 765kV transmission line will be maintained by live-line works for efficient operation, In order to maintain the 765kV transmission lines safely by live-line works, lineman have to know flashover characteristics of the insulator strings with damaged insulators. This paper suggests flashover characteristics of the 765kV insulator strings from experimental test results directly.

  • PDF

Magnetic Field Reduction Characteristics of Hot-Line Worker's Shielding Wear for 765kV Double Circuit Transmission Line (765kV 2회선 송전선 활선 작업자의 차폐복 자계저감 특성검토)

  • Min, Suk-Won;Park, Jun-Hyeong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.9
    • /
    • pp.1632-1637
    • /
    • 2007
  • This paper analyses current densities induced inside human body of lineman for 765kV transmission line when he wears a protective cloth or not. Applying the boundary element method, we calculate current densities induced in organs inside a worker in case he was located at 15[cm], 30[cm], 50[cm], and 100[cm] far from a prefabricated jumper. As results of study, we find a maximum current density induced in all organs may be higher than $10[mA/m^2]$ if he does not wear protective clothes. We also know high permeability materials can lower current density more than high conductivity materials.

Development of Live-line Insulator Tester and Its Application to 154kV Power Lines - Part 1 : Tester Development (활선애자점검기의 개발 및 154kV 선로에의 적용 - 제1부 : 점검기 개발)

  • Lee, Jae-Kyung;Park, Joon-Young;Cho, Byung-Hak;Oh, Ki-Yong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.1
    • /
    • pp.83-88
    • /
    • 2010
  • A new live-line insulator tester was developed to detect faulty insulators in 154kV power transmission lines. This paper is the first part of the two-part paper and deals with its tester development. The developed tester has the following characteristics. First, it automates parts of the insulator inspection process by using a sensor and an actuator, and secondly, it sustains its weight by itself, not by a lineman. Finally, it measures the insulation resistance of an insulator together with its distribution voltage to provide more information for its analysis and diagnosis. These leads to the improvement of its operation efficiency, measurement reliability and usability. Its effectiveness was validated by live-line field tests in actual power lines.

A study on the transmission system realization using residential power line carrier (전등선 반송방식 통신시스템 실현에 관한 연구)

  • Kim, In-Soo;Oh, Won-Rock;Kim, Kwan-Ho;Oh, Sang-Ki
    • Proceedings of the KIEE Conference
    • /
    • 1989.07a
    • /
    • pp.707-711
    • /
    • 1989
  • This system exchange half-duplex serial data at 1200 baud by FSK modulating a carrier frequency at 200KHz over the 110V A.C. power line. Transmitter output voltage to A.C. line is 4V p-p and line sensitivity is selected 2.54mV because CISPR Noise limitation is $66dB{\mu}V$ at 150 ${\sim}$ 500KHz. The designed and realized system has abtained system margin of 58 dB and probability of error, Pe = $1.78{\times}10^{-7}$ was obtained

  • PDF

A Type Test of 154 kV Transmission Line Arrester for improvement of lightning performance (내뢰성 향상을 위한 154 kV 송전선용 피뢰기의 성능 시험)

  • Kwak, J.S.;Kang, Y.W.;Woo, J.W.;Shim, E.B.;Kim, Y.S.
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.454-456
    • /
    • 2003
  • This paper describes a type test results of 154 kV transmission line arrester with external gap. The test was carried on surge arrester unit and line arrester with external gap, respectively. Withstand voltage test demonstrate the voltage withstand capability of the line arrester with external series gap under the dry and wet conditions. In insulation coordination test external series gap shall be discharged every time when lightning impulse voltage with the steepness of more than 1500 $kV/{\mu}s$ are applied under the wet condition.

  • PDF

ON MINIMAL SURFACES WITH GAUSSIAN CURVATURE OF BIANCHI SURFACE TYPE

  • Min, Sung-Hong
    • Journal of the Chungcheong Mathematical Society
    • /
    • v.34 no.4
    • /
    • pp.379-385
    • /
    • 2021
  • We consider the local uniqueness of a catenoid under the condition for the Gaussian curvature analogous to Bianchi surfaces. More precisely, if a nonplanar minimal surface in ℝ3 has the Gaussian curvature $K={\frac{1}{(U(u)+V(v))^2}}$ for any functions U(u) and V (v) with respect to a line of curvature coordinate system (u, v), then it is part of a catenoid. To do this, we use the relation between a conformal line of curvature coordinate system and a Chebyshev coordinate system.

A Study on the Visual Interpretation of the Clothing Image as Clothing m Form and Dot Space Variation. (의복형태와 물방울무늬 공간변화에 따른 이미지의 시각적 평가)

  • 문삼련;이경희
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.18 no.1
    • /
    • pp.3-14
    • /
    • 1994
  • This study is intended to identify the clothing mage as clothing form and dot space variation. This study consists of pre-experiment for setting the space between dot which shows the difference of the image and main experiment and also is made of factorial design for two variables-clothing form(H-line, A-line, V-line, X-line) dot (dot 1.0, dot 2.2, dot 3.4, dot 5.8) Qestionaire consists of 21 semantic differential scale expressing clothing form and .dot. Data is obtained from 50 female students maforing clothing and textile. The results of this study are as follows. 1) The image by the clothing form and the space dot variation is composed 5 factors' attention, activity, attraction, maturity, boldness. 2) The image by variation in clothing form dot has significant differences in attractive and attention factors, especially shows remarkable differences in attention. By choosing narrow space dot for attentive image, broden space dot for attractive image, you would be able to create the image you want. 3) The image by variation in dot clothing form has almost signific and differences in all factors, especially shows remarkable differences in activity. By choosing A-line for active image, V-line for mature and fashionable image, X-line for attractive, pretty and delicate mage, you would be able to create the image you want. 4) The interaction effect between clothing form and space dot was in attraction and maturity factor, V-line, X-line, dot 3.4 and dot 5.8 intensify attractive image, V-line and dot 1.0 mature image, X-line and dot 5.8 young image.

  • PDF

A Practical Application Study on the Transmission Line Design S/W using Optimal PowerLINE - A Case Study on the 500kV Transmission Line Design in Myanmar Project - (송전선로 설계지원 프로그램의 활용에 대한 적용성 연구 - Optimal PowerLINE을 이용한 미얀마 500kV 송전선로 종단설계를 중심으로 -)

  • Yoon, Young-Soon;Kim, Tai-Young;Park, Chan-Hyeong;Cho, Su-Young;Park, Byeong-Won;Lee, Hee-Sun
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.542-544
    • /
    • 2005
  • Recently, the principal processes of T/L design tend to computerize and therefore integrated T/L design system has been developed. Since, it makes the automatic selection of T/L route, tower position and optimum design possible, computerized design method is applied all over the world. KEPCO introduced Optimal PowerLINE for T/L design in Myanmar 500kV project that is as a part of overseas project. And as a result of that work, effective and economical design was carried out. This paper presents the comparative analysis between Previous method and Optimal PowerLINE method for investigating practical application to Myanmar 500kV T/L design.

  • PDF

Low Voltage Swing BUS Driver and Interface Analysis for Low Power Consumption (전력소모 감소를 위한 저 전압 BUS 구동과 인터페이스 분석)

  • Lee Ho-Seok;Kim Lee-Sup
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.36C no.7
    • /
    • pp.10-16
    • /
    • 1999
  • This paper describes a low voltage swing bus driver using FCSR(Feedback Control Swing voltage Reduction) which can control bus swing voltage within a few hundred of mV. It is proposed to reduce power consumption in On-chip interface, especially for MDL(Merged DRAM Logic) architecture wihich has wide and large capacitance bus. FCSR operates on differential signal dual-line bus and on precharged bus with block controlling fuction. We modeled driver and bus to scale driver size automatically when bus environment is variant. We also modeled coupling capacitance noise(crosstalk) of neighborhood lines which operate on odd mode with parallel current source to analysis crosstalk effect in the victim-line according as voltage transition in the aggressor-line and environment in the victim-line. We built a test chip which was designed to swing 600mV in bus, shows 70Mhz operation at 3.3V, using Hyundai 0.8um CMOS technology. FCSR operate with 250Mhz at 3.3V by Hspice simulation.

  • PDF

Site Evaluation and Application of the On-line and Off-line Test for the 13[kV] Class Hydropower Generator Stator Windings (13[kV]급 수력발전기 고정자 권선의 운전 및 정지 중 진단시험 현장적용 평가 및 분석)

  • Chang, Jeong-Ho;Lee, Dong-Keun;Lee, Heung-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.11
    • /
    • pp.73-82
    • /
    • 2011
  • The solid insulation system of stator windings in high voltage rotational machines is usually aging in accordance with long time operation. The partial discharge test have been known to check whether insulation deterioration exist or not, and the PD test can effectively diagnose a solid insulation condition regardless of during operation(on-line) or not(off-line). The on-line PD measurement have proven to be a successful technique in monitoring stator insulation condition nowadays. This paper describes the characteristics of comparing the on-line PD measurement data using PDMS-HG(Partial Discharge Monitoring System for Hydro-electric Generator) installed in field with the off-line diagnosis measurement data(insulation resistance, winding resistance, PI, ${\Delta}tan{\delta}$ and PD) on hydro generator(13[kV]) stator windings. These results make good use of managing rotational machines through evaluating the solid insulation condition of stator windings.