• 제목/요약/키워드: Unit heating

검색결과 497건 처리시간 0.031초

다원기술 상호보완식 태양열 난방기술 - 저원가 고효율 규모화 태양열 난방 방안 - (A Study on Solar Heating System Technology Combining Multiple Technology with Mutual-Complementary Method - Low-cost, high efficiency, large-scale use of solar heating system -)

  • 남보현
    • 한국태양에너지학회 논문집
    • /
    • 제28권6호
    • /
    • pp.15-23
    • /
    • 2008
  • The article deals with system technology of a new solar heating system which systematically combines exiting solar collector technology, auxiliary electrical water heating, floor heating system and well insulated construction method and its application of this system to apartment house heating system in the cold region, and also analyzed performance of the new system in terms of technical and economic feasibility. Results shows that energy efficiency approaches up to 50% of the energy consumption of local construction from 1980 to 1981. The implementation of "DQ technology" to floor heating system achieved from 79% to 85% of the energy-saving benefits comparing to other housing units which were supplied by the local district heating plant.

3차원 전열해석 및 생애비용 분석을 통한 커튼월 앵커링 유닛의 단열성능 향상 방안 평가 (Insulation Performance Evaluation of the Curtain Wall Anchoring Unit by 3D Heat Transfer Simulation and Life Cycle Cost Analysis)

  • 강승희;송승영
    • 한국태양에너지학회 논문집
    • /
    • 제23권4호
    • /
    • pp.63-70
    • /
    • 2003
  • It is very important to improve the insulation performance of curtain wall anchoring unit since it is composed of materials with high thermal conductivity, such as aluminium, steel and so on. This study aims to evaluate the heating energy performance and economical efficiency of various alternatives which are different in position and material of insulation. As results, alternative of inserting the urethane washer & pad and coating the anchoring unit with urethane foam can improve the heating energy performance and L.C.C(Life Cycle Cost) by 6.33% and 0.95%, respectively, as compared with the existing case.

A Study on the Supply Process of Unit Modular Housing through a Comparison of Cases

  • Kim, Kyoon-Tai;Jun, Young-Hun;Kim, Tae-Yeong
    • 국제학술발표논문집
    • /
    • The 6th International Conference on Construction Engineering and Project Management
    • /
    • pp.411-414
    • /
    • 2015
  • The purpose of this study is to conduct a comparative analysis between Korea and the United States of the supply process of unit modular housing at both the factory production phase and the transportation and lifting phase, as part of an attempt to invigorate the unit modular housing market in Korea. Unlike the practice in the United States, one of Korea's unique characteristics is that the floor is constructed with reinforced concrete and hot water heating system. To do this, the wet method in Korea is used that includes concrete placement, curing and constructing hot water floor heating system at the factory production phase, which results in a longer production time and also requires the lifting of heavier loads. In the United States, interior and exterior finishing works of modular housing are performed by different companies, and the distance between the unit module factory and the construction site is quite far. This kind of dualized production structure may cause confusion when it comes to schedule management, procurement management, and stock management. Moreover, problems caused by external environmental factors such as wind and rainfall were reported in the course of long-distance transportation. The results of this case comparison are expected to provide fundamental data that will reduce the amount of trial and error in the unit module production, transportation and lifting work in Korea, which has a comparatively small number of unit modular housing cases.

  • PDF

지열원 멀티 열펌프 시스템의 시설원예 적용 난방성능 특성 실증 연구 (Heating Performance of a Ground Source Multi-Heat Pump for a Greenhouse)

  • 강신형;최종민;문제명;권형진
    • 설비공학논문집
    • /
    • 제22권6호
    • /
    • pp.337-344
    • /
    • 2010
  • Good plant-growth conditions can be achieved by means of using greenhouses. One of the main issues in greenhouse cultivation is energy savings through the development of high efficient heating and cooling system. GSHPs are one of the recommended systems to cope with this pending need. The aim of this study is to investigate the heating performance of ground source multi-heat pump system installed in a greenhouse under part load conditions. Daily average heating COP of the heat pump unit was very high by at least 7.4, because of relatively large condenser, evaporator, and mass flow rate through ground loop heat exchanger. However, the system COP, overall heating coefficient of the performance of the system with heat pump unit and GLHX, decreased drastically due to relatively large power consumption of circulating pump under part load condition. It is suggested that the technology to enhance the performance of the ground source multi-heat pump system for a greenhouse under part load conditions should be developed.

LCC 기법을 이용한 영구임대아파트 난방방식 리모델링에 대한 경제성분석 -유지관리비용을 중심으로- (The Economic Analysis on the Heating System Remodeling by the Life Cycle Costing in Permanent Rental Apartment)

  • 박민용;장승재
    • 한국주거학회논문집
    • /
    • 제15권1호
    • /
    • pp.33-40
    • /
    • 2004
  • Considering the present development situation of rental apartment since 1982, the supply of rental housing for low-income dwellers has contributed a amount of quantities, but has been deficient qualities in housing policy. To propose the device of remodeling for low-income dwellers in deteriorated apartment, this study investigated the energy consumption of central heating system and the characteristics of maintenance cost in permanent rental apartment. The results of evaluation of alternative heating systems by Life Cycle Costing in permanent rental apartment were as follows; From Life Cycle 15∼20 years by Present Worth Method, the economic heating system of remodeling is central heating system (heat source: B-C oil), unit heating system(natural gas), central heating system(natural gas) in order.

고등학교 기숙사 주거시설에 대한 사용자 만족도 - 개인공간 단위실을 중심으로 - (Users' Satisfaction on the Dormitory of High School in Jeonju City)

  • 안진숙;최병숙
    • 한국주거학회논문집
    • /
    • 제18권6호
    • /
    • pp.93-101
    • /
    • 2007
  • This study was to find out users' satisfaction on the dormitory of high school in Jeonju City and to propose it's physical environmental improvement directions. This was performed by a questionnaire survey method, and the questionnaire was designed by researchers considering relative literatures. Data were collected from 200 students, who had been dwelling 4 high school dormitories in Jeonju City. By analyzing those data, findings were as follows: 1) Users of students were satisfied the whole of their dormitory; facilities, spaces, and living. 2) They were highly concerned about a library and a personal unit space in their dormitory. 3) They needed their personal unit space to be designed bedroom+bathroom type with 2 persons' sharing and be equipped one story bed and desk furniture. Also, they needed improvement on heating & cooling, small space and indoor air quality of unit space. 4) The users' satisfaction on unit space were 2.88, and their satisfaction of the technical factor was 2.71 that was the lowest score in them. And The functional factor was highly effected their satisfaction. 5) The space utility and the space size of functional factor, the soundproof, the heating/ventilation and the indoor quality of technical factor, and the privacy of behavior factor were highly correlative to their satisfaction of unit space.

대구광역시 단독주택의 에너지 및 온실가스 배출원단위 작성에 관한 연구 (A Study on the Energy Consumption and Greenhouse Gas Emission of the Detached Houses in Daegu)

  • 김유란;윤혜경;김주영;전규엽;홍원화
    • 한국주거학회논문집
    • /
    • 제22권2호
    • /
    • pp.35-42
    • /
    • 2011
  • In the energy consumption of buildings in Korea, the housing sector accounts for 53% of a total energy consumption. Although the researches of energy consumption on the new detached houses and apartment houses have been conducted numerous times, the researches of energy consumption characteristics on the existing detached houses are lack of studies. Thus in this study, the actual condition of energy consumption characteristics on the existing detached houses in Daegu city was examined, and then energy consumption unit and green house gas emission unit was compiled to present a fundamental data for an effective way of reducing energy consumption and greenhouse gas emission in the buildings. The results showed that the energy consumption for heating in the existing detached house was greater than other energy consumption and the heating energy sources were city gas and fuel oil. As the fuel oil consumption got larger, the energy consumption unit and greenhouse gas emission unit became bigger. Based on these results, it will be able to develop a plan for reducing energy and greenhouse gas emission in the existing detached houses in the future.

방수·방근시트와 옥상녹화 박스유닛 시스템의 일체화를 위한 전자기 유도가열 융착 고정구의 부착성능 (Adhesion Performance of Electromagnetic Induction Heating Pixture for the Integration with a Waterproof & Root Barrier Sheet and a Roof Green Unit System)

  • 오창원
    • 한국건축시공학회지
    • /
    • 제18권5호
    • /
    • pp.463-469
    • /
    • 2018
  • 기존의 다층으로 구성되어 시공성이 낮은 옥상녹화 공법의 개선을 위해 개발한 방수 방근 시트 일체화 옥상녹화박스 유닛공법의 일체화를 위해 사용하는 전자기 유도가열방식의 금속 고정구와 콘 형상 고정구의 부착성능을 평가하기 위해 엔지니어링 PE, TPO, PVC 시트 등 3종류의 시트에 가열온도에 따른 부착성능 및 동일한 시험체로 냉열반복 후 부착성능을 측정하였다, 그 결과는 엔지니어링 PE시트에 부착한 고정구의 부착성능이 가장 우수하게 나타났으며, 금속고정구는 가열온도가 올라갈수록, 콘 형상 고정구는 가열온도가 낮을수록 우수한 부착성능을 보여주었고, 냉열 반복 후 부착시험 결과는 상온 부착시험 결과와 동일하게 나타났다. 기존의 양면 부틸테이프 고정방식의 콘 형상 고정구는 낮은 부착하중과 냉열반복에 의한 뚜렷한 성능저하가 발생하는데 비하여 전자기 유도가열방식의 고정구는 우수한 성능을 유지하였다.

Variations in the hysteretic behavior of LRBs as a function of applied loading

  • Ozdemir, Gokhan;Bayhan, Beyhan;Gulkan, Polat
    • Structural Engineering and Mechanics
    • /
    • 제67권1호
    • /
    • pp.69-78
    • /
    • 2018
  • The study presented herein focused on the change in hysteretic force-deformation behavior of lead rubber bearings (LRBs). The material model used to idealize response of LRBs under cyclic motion is capable of representing the gradual attrition in strength of isolator unit on account of lead core heating. To identify the effect of loading history on the hysteretic response of LRBs, a typical isolator unit is subjected to cyclic motions with different velocity, amplitude and number of cycles. Furthermore, performance of an LRB isolated single degree of freedom system is studied under different seismic input levels. Finally, the significance of lead core heating effect on LRBs is discussed by considering the current design approach for base isolated structures. Results of this study show that the response of an LRB is governed strongly by the amplitude and number of cycles of the motion and the considered seismicity level.

PIV 유동 계측을 통한 천장형 실내기의 최적 제어 설계 (Optimal Flow Control of Ceiling Type Indoor Unit by PIV Measurements)

  • 성재용;안광협;이기섭;최호선;이인섭
    • 대한기계학회논문집B
    • /
    • 제27권8호
    • /
    • pp.1042-1050
    • /
    • 2003
  • A heating flow discharged from a 4-way ceiling type indoor unit has been investigated to determine the design parameters for the optimal flow control. The flow was measured by a PIV(particle image velocimetry) system and an experimental model of 1/10 scale with a transparent room was devised by satisfying the Archimedes number. This similarity is generally used in cases where the forced convection has similar magnitude of the natural convection. To optimize the heating flow, several vane angles and vane control algorithms of cross and right angle controls were considered. Regarding the vane angle, experimental results show that 30$^{\circ}$is an optimal angle to avoid re-suction flows without significant increase in flow noise. Temperature distribution measured in the environmental chamber ensures the increased thermal comfort when compared to the case, 60$^{\circ}$angle. At the optimal angle, applying open/close control gives rise to more uniform distribution of the heating flow than without control. Especially, the cross-control seems to be satisfactory for thermal comfort.