• Title/Summary/Keyword: UPS Function

Search Result 115, Processing Time 0.032 seconds

Power Factor Correction of Single-phase Boost Converter for Low-cost Type UPS Configuration (저 가격형 UPS를 구성하기 위한 단상 부스트 컨버터의 고 역률 제어)

  • Park, Jong-Chan;Shon, Jin-Geun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.62 no.3
    • /
    • pp.145-150
    • /
    • 2013
  • A novel AC to DC PWM converters with unity input power factor are proposed to overcome the above shortcoming. The main function of these converters is to shape the input line current to force it exactly in phase with the input AC voltage. Therefore, the input power factor can be improved to near unity and the input current harmonics can be eliminated. In this paper, half-bridge converter with two active switches and two diodes are utilized for low-cost type UPS configuration. By having only two semiconductors in the current path at any time, losses can be reduced over the conventional boost topology. Also, this converter provides controllable dc-link voltage, high power factor, and low cost type converter by simple power circuits. Simulation results show that the proposed half-bridge converter/inverter control technique can be applied to single-phase low-cost type UPS systems successfully.

Grid connected 3-phase inverter with photovoltaic generation, battery charger/discharger, and UPS function (태양광 발전-충방전기능-UPS 기능을 갖는 계통 연계형 15kW급 3상 인버터)

  • Kwon, Jungmin
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.50.1-50.1
    • /
    • 2011
  • 전력수요가 적을 때 잉여전력을 저장하고 전력수요가 많은 시간대나 전기료가 비싼 시간대에 저장된 전력을 사용함으로서 전력의 활용 효율을 높이고, 전력공급 시스템을 안정화하기 위해 에너지저장시스템의 연구가 최근에 활발히 진행되고 있다. 또한 공장, 산업용빌딩이나 병원 등 고르고 안정적인 전력의 수요는 늘어나고 있으며, 화석 연료 고갈 문제로 인한 신재생에너지 발전의 중요성도 대두되고 있다. 본 논문에서는 무정전 전원장치, 태양광발전시스템, 에너지 저장 시스템을 모두 통합하였다. 제안한 시스템은 3상 인버터, 부스트 컨버터, 양방향 컨버터, 사이리스터 스위치로 구성된다. 인버터는 계통과 연계되거나 UPS 동작 시 AC 전력을 만든다. 부스트 컨버터는 태양광 패널과 연결되어 MPPT 제어를 수행한다. 양방향 컨버터는 잉여전력을 배터리에 저장을 하고, 전력이 부족할 시에는 배터리의 전력을 방전한다. 사이리스터 스위치는 정전 시 계통과 부하를 끊어주는 역할을 한다. 본 논문에서는 15kW급 시스템으로 구현하여 검증하였다.

  • PDF

Evaluation of Abdominal Wall Function after TRAM Breast Reconstruction: A Prospective Study in 375 Consecutive Cases (횡복직근피판술을 이용한 유방재건 후 복벽의 운동능력에 관한 전향적 연구)

  • Kang, Byeong Su;Eom, Jin Sub;Lee, Taik Jong
    • Archives of Plastic Surgery
    • /
    • v.34 no.4
    • /
    • pp.436-440
    • /
    • 2007
  • Purpose: TRAM flap surgery has settled down as a common method for breast reconstruction after mastectomy. We investigated how TRAM flap surgery influences on the patients' physical movement capability by observing their capability of sit-ups as well as exercises they usually enjoy. Methods: A total of consecutive 375 patients were investigated who had breast reconstruction with unilateral pedicled TRAM flap surgery at Asan Medical Center from July 2001 to August 2005. The patients were asked to sit up right before the surgery and do it again 6 months later and 1 year later. 221 patients were followed up 6 month after the surgery. And 132 patients were followed up 1 year after the surgery. In addition, 155 patients who used to exercise before the surgery were also asked to show us the change in their physical movement capability one year after their surgery. Results: 139 patients showed decrease in the counted number of sit-ups, 48 increase, and 34 showed no change between 6 months in the first group of 221 patients. Among the second group of 132 patients, 64 showed decrease, 39 increase, and 29 no change a year later. There was a statistical significant decrease in the number of sit-ups between pre-operation and six months later and between pre-operation and one year later. According to the research on the exercise that 155 patients participated, 3 of them showed improvement in athletic ability, 7 showed decrease, while the rest, 145 patients, showed no change at all. Conclusion: Considering no difference in usual exercise ability, some patients' increase in the number of sit-ups and the effect of anticancer treatment, we found that the loss of abdominal wall function on this research is not too serious to exclude TRAM flap surgery in the field of breast reconstruction

Development of Uninterruptible Power Supply with Voltage Sag Restorer Function (순시전압강하 보상 기능을 가지는 무정전전원공급장치의 개발)

  • Park, Jong-Chan;Shon, Jin-Geun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.2
    • /
    • pp.95-101
    • /
    • 2014
  • In this paper, UPS, with a built-in instantaneous sag drop compensation features, was developed to improve performance. The improved UPS, using instantaneous moving average method, compensates by quickly measuring the voltage and series inverter of half-bridge type, using line-interactive method that links with the voltage of the battery and power source, was developed. In addition, by developing a parallel inverter that uses a high-efficiency PWM switching method, overall UPS system was enhanced. To verify the performance of the proposed algorithm, single-phase 5[kVA] UPS systems were designed and the experimental system was constructed. The low-cost type of Cortex-M3 module CPU STM32F103R8T6 (32[bit]) is attached and the switching time of mode transfer was set within 4 [ms]. THD of the linear load operates in less than 3[%], and the stability of the output voltage operates in approximately ${\pm}2[%]$ range. The superior performance of the operations was confirmed with the system set as above.

Controlling Work Function of Graphene by Chemical Doping

  • Lee, Ji-A
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.628-628
    • /
    • 2013
  • Graphene, a single layer of graphite, has raised extensive interest in a wide scientific community for its extraordinary thermal, mechanical, electrical and other properties [1,2]. However, because of zero-band gap of graphene, it is difficult to apply for electronic applications. To overcome this problem, chemical doping is one of way to opening grahene bandgap. According to experimental results, by changing doping concentration and doping time, it is possible to control work function of graphene. We can obtain results through raman spectroscopy, UPS, Sheet resistance. Moreover, electronic properties of doped graphene were studied by making field effect transistors. We were able to control the doping concentration, dirac point of graphene and work function of graphene by formng n-type, p-type doping materials. In this research, the chemicals of diazonium salts, viologen, etc. were used for extrinsic doping.

  • PDF

Design of Robust Double Digital Controller to Improve Performance for UPS Inverter (UPS 인버터의 성능 개선을 위한 강인한 2중 디지털 제어기의 설계)

  • 박지호;노태균;김춘삼;안인모;우정인
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.2
    • /
    • pp.116-127
    • /
    • 2003
  • In this paper, a new fully digital control method for UPS inverter, which is based on the double control loop such as the outer voltage control loop and inner current control loop, is proposed. In the proposed control system, overshoots and oscillations due to the computation time-delay are compensated by explicit incorporation of the time-delay in the current control loop transfer function. The inner current control loop is adopted by an Internal model controller The Internal model controller is designed to a second order deadbeat reference-to-output response which means that its response reaches the reference in two sampling time including computational time-delays. The outer voltage control loop employing P-Resonance controller is proposed. The resonance controller has an infinite gain at resonant frequency, and the resonant frequency is set to the fundamental frequency of the reference voltage in this paper. Thus the outer voltage control loop causes no steady state error as regard to both magnitude and phase. The effectiveness of the proposed control system has been verified by the simulation and experimental results respectively.

A PCS Control Strategy for Hybrid ESS with Function of Emergency Power Supply (비상전원 기능을 갖는 하이브리드 ESS를 위한 PCS 제어전략)

  • Kim, Sang-Jin;Kwon, Min-Ho;Choi, Se-Wan;Paik, Seok-Min;Kim, Mi-Sung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.21 no.4
    • /
    • pp.302-311
    • /
    • 2016
  • This paper proposes a hybrid ESS that integrates an energy storage system (ESS) with an uninterruptible power supply (UPS). The hybrid ESS has a demand management and emergency power supply function while increasing the battery utilization of the UPS, which has just been used in a power failure. In addition to the critical load, the proposed system augments the capacity of emergency generation using an additional load, which has voltage and frequency-dependent characteristics to the grid side. The control algorithm of the AC-DC converter and bidirectional DC-DC converter is proposed for demand management and emergency power supply. Furthermore, seamless and autonomous transfer methods to alleviate the transient during mode transfer are proposed. To validate the proposed control scheme, experimental results from a 5 kW prototype are provided.

Output Filter and Controller designs for UPS Inverter with Single-Phase (단상 UPS 인버터의 출력필터와 제어기 설계)

  • Kim, Jae-Sig;Choi, Chang-Ho;Choi, Jae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.1064-1066
    • /
    • 2001
  • In this paper, the harmonic components generated by those two sources are analyzed separately based on the transfer function and shown as the closed form considering the switching frequency, speed of the control processor, gain of the controller, and the inductor and capacitor value of L-C filter. A design procedure is described with one flow chart and explained step by step.

  • PDF

Work Function Modification of Indium Tin Oxide Thin Films Sputtered on Silicon Substrate

  • Oh, Gyujin;Kim, Eun Kyu
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.351.2-351.2
    • /
    • 2014
  • Indium tin oxide (ITO) has a lot of variations of its properties because it is basically in an amorphous state. Therefore, the differences in composition ratio of ITO can result in alteration of electrical properties. Normally, ITO is considered as transparent conductive oxide (TCO), possessing excellent properties for the optical and electrical devices. Quantitatively, TCO has transparency over 80 percent within the range of 380nm to 780nm, which is visible light although its specific resistance is less than $10-3{\Omega}/cm$. Thus, the solar cell is the best example for which ITO has perfectly matching profile. In addition, when ITO is used as transparent conductive electrode, this material essentially has to have a proper work function with contact materials. For instance, heterojunction with intrinsic thin layer (HIT) solar cell could have both front ITO and backside ITO. Because each side of ITO films has different type of contact materials, p-type amorphous silicon and n-type amorphous silicon, work function of ITO has to be modified to transport carrier with low built-in potential and Schottky barrier, and approximately requires variation from 3 eV to 5 eV. In this study, we examine the change of work function for different sputtering conditions using ultraviolet photoelectron spectroscopy (UPS). Structure of ITO films was investigated by spectroscopic ellipsometry (SE) and scanning electron microscopy (SEM). Optical transmittance of the films was evaluated by using an ultraviolet-visible (UV-Vis) spectrophotometer

  • PDF

Internal Model Control of UPS Inverter using Resonance Model

  • Park J. H.;Kim D. W.;Kim J. K.;Lee H. W.;Noh T. K.;Woo J. I.
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.184-188
    • /
    • 2001
  • In this paper, a new fully digital control method for single-phase UPS inverter, which is based on the double control loop such as the outer voltage control loop and inner current control loop, is proposed. The inner current control loop is designed and implemented in the form of internal model control and takes the presence of computational time-delay into account. Therefore, this method provides an overshoot-free reference-to-output response. In the proposed scheme, the outer voltage control loop employing P controller with resonance model implemented by a DSP is introduced. The proposed resonance model has an infinite gain at resonant frequency, and it exhibits a function similar to an integrator for AC component. Thus the outer voltage control loop causes no steady state error as regard to both magnitude and phase. The effectiveness of the proposed control system has been demonstrated by the simulation and experimental results respectively.

  • PDF