• Title/Summary/Keyword: Twisted installation

Search Result 12, Processing Time 0.022 seconds

Seismic Response Control Performance Evaluation of Twisted Irregular Building by TMD Distributed Application (TMD 분산 설치에 따른 Twisted 비정형 건축물의 지진응답 제어 성능 평가)

  • Yoo, Sang-Ho;Park, Kwang-Seob;Kim, Hyun-Su;Kang, Joo-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.24 no.3
    • /
    • pp.61-68
    • /
    • 2024
  • High-rise buildings are equipped with TMD (Tuned Mass Damper), a vibration control device that ensure the stability and usability of the building. In this study, the seismic response control performance was evaluated by selecting the design variables of the TMD based on the installation location of the twisted irregular building. To this end, we selected analysis models of 60, 80, and 100 floors with a twist angle of 1 degree per floor, and performed time history analysis by applying historical seismic loads and resonant harmonic loads. The total mass ratio of TMDs was set to 1.0%, and the distributed installation locations of TMDs were selected through mode analysis. The analysis results showed that the top-floor displacement responses of all analysis models increased, but the maximum story drift ratio decreased. In order to secure the seismic response control performance by distributed installation of TMDs in twisted irregular buildings, it is judged that the mass ratio distribution of TMDs will act as a key variable.

Comparison of the Effects of Straight and Twisted Heat Trace Installations Based on Three-dimensional Unsteady Heat Transfer (열선의 직선시공과 감기시공의 동파방지 효과 비교를 위한 3차원 비정상 수치해석)

  • Choi, Myoung-Young;Jeon, Byoung-Jin;Choi, Hyoung-Gwon
    • Fire Science and Engineering
    • /
    • v.30 no.1
    • /
    • pp.49-56
    • /
    • 2016
  • This paper numerically examines, straight and twisted electrical heat trace installations for their anti-freezing effects on water inside a pipe. The unsteady incompressible Navier-Stokes equations coupled with an energy equation were solved to compare the two installation methods. The heat conduction of the pipe with a heat source interacts with the natural convection of the water, and the conjugate heat transfer was considered using a commercial code (ANSYS-FLUENT) based on a SIMPLE-type algorithm. Numerical experiments, were done to investigate the isotherms and the vector fields in the water region to extract the evolutions of the minimum and maximum temperatures of the water inside the pipe. There was no substantial difference in the anti-freezing effects between the straight and twisted. Therefore, the straight installation is recommended after considering the damage and short circuit behavior of the electrical heat trace.

Polarimetric fiber-optic current sensor system using a twisted fiber sensing coil (비틀린 광섬유 센서코일을 이용한 편광분석형 광섬유 전류센서)

  • 송민호;김기혁
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.2
    • /
    • pp.135-141
    • /
    • 2004
  • We developed a polarimetric fiber-optic current sensor system for protective relaying usage. A fiber sensing coil that consisted of a length of twisted fiber and a FRM (Faraday rotator mirror) was used in order to suppress the linear birefringence effect. From the experiments with various sensing coil configurations and environmental conditions, the proposed current sensor system showed feasibility of suppressing environmental noises, and the obtained measurement stability was less than $\pm$3% at rated primary current.

Displacement Response Analysis of Twisted Irregular Buildings According to TMD (TMD 적용에 따른 Twisted 비정형 건축물의 변위 응답 분석)

  • Yoo, Sang-Ho;Kim, Hyun-Su;Kang, Joo-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.24 no.1
    • /
    • pp.89-98
    • /
    • 2024
  • In this study, we investigated the dynamic characteristics of three irregular building models to analyze the effectiveness of displacement response control with Tuned Mass Damper (TMD) installation in twisted irregular buildings. The three irregular models were developed with a fixed angle of twist per story at one degree, subjected to three historical seismic loads and resonant harmonic loads. By designing TMDs with linear and dashpot attributes, we varied the total mass ratio of the installed TMDs from 0.00625% to 1.0%, encompassing a total of 10 values. Two TMDs were installed at the center of the top story of the analysis model in both X and Y directions to evaluate displacement response control performance based on TMD installation. Our findings suggest that the top displacement response control performance was most effective when a 1.0% TMD was installed at the top layer of the analysis model.

A Study on the Spacer Installation Method for 2-Conductor Bundle Transmission Lines (2도체 송전선로의 스페이서 취부방식 연구)

  • Min, Byeong-Wook;Kim, Woo-Kyum;Choi, Han-Yeol;Park, Kee-Yong;Kim, Won-Jin;Park, Jae-Ung
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.333-334
    • /
    • 2008
  • Overhead transmission lines are classified by the number of sub conductors per phase. Korean transmission lines use two, four, or six-conductor bundle. Bundle of conductors must have spacers or spacer dampers which keep the proper distance between sub conductors. They can prevent conductors from being vibrated or twisted due to the wind. As for the two-conductor bundle, alternating current flow generates absorption force between sub conductors which may cause a collision of sub conductors. To prevent sub conductors from being vibrated, twisted, and collided, spacer or spacer damper installation method is designed considering vibration characteristics of sub conductors. We have spacer installation method for four or six-conductor bundle lines. However, we don't have it for two-conductor bundle ones. So we have installed spacers at regular intervals in two-conductor bundle lines, and it caused rigid body oscillation of conductors due to the wind which made a flashover between conductors. This paper introduces a vibration characteristic analysis of two-conductor bundle and proposes a spacer installation method for two-conductor bundle lines.

  • PDF

Method Development of Location Point Control For Freeform Metal Panel Installation - Focused on the Application of LH JinJu New Office- (비정형 금속패널 설치를 위한 지점 제어 공법 개발 -LH 진주 신사옥 적용을 중심으로-)

  • Kim, Sung-Jin;Kim, Chung-Shik;Ryu, Han-Guk
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.05a
    • /
    • pp.258-259
    • /
    • 2013
  • Recently, architectural design has been changing from formal design to freeform design due to the digitalization of construction industry. Especially, the formal design has been accepted as a design trend recently and applied many times as a design concept in the architectural design competitions such as turn-key. However, various deflects such as water leak and cracks have been occurred because the traditional construction methods had been applied without any revision or adaptation of the formal construction method for the freeform building construction. Therefore this research proposes location point control method for freeform metal panel installation which is focused on the application of LH JinJu new office.

  • PDF

Experimental Study of the Flat & Twisted Rudder Characteristics Using Rudder Dynamometer in LCT (LCT에서 방향타 동력계를 이용한 평판 및 비틀림 방향타 특성의 실험적 연구)

  • Ahn, Jong-Woo;Paik, Bu-Geun;Park, Young-Ha;Seol, Han-Shin
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.58 no.6
    • /
    • pp.391-399
    • /
    • 2021
  • In order to investigate force and cavitation characteristics for the flat & twisted rudders in the Large Cavitation Tunnel (LCT), the rudder dynamometer was designed and manufactured. The measuring capacities of lift, drag and moment are ±1000 N, ±2000 N, and ±150 N-m, respectively. The present dynamometer uses the actuator with a harmonic drive to control the rudder angle without backlash. As the target ship is a military ship with twin shaft, each dynamometer was installed above the port & starboard rudders. After the installation of the model ship with all appendages, the model test composed of rudder force measurement and cavitation observation was conducted for the existing flat rudder & the designed twisted rudder. While the flat rudder showed the big difference of lift & moment between port & starboard, the twisted rudder presented a similar trend. The cavitation of the twisted rudder showed better characteristics than that of the flat rudder. Another set of model tests were conducted to investigate rudder performance by the change of the design propeller. There was little difference in rudder performance for the design propellers with slight geometric change. Through the model test, the characteristics of the flat & twisted rudders were grasped. On the basis of the present study, it is thought that the rudder with better performance would be developed.

Polarimetric Fiber-optic Current Transformer using a Spun Fiber (스펀 광섬유를 이용한 편광 분석형 광섬유 전류센서)

  • Park, Hyong-Jun;Kim, Hyun-Jin;Song, Min-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.1
    • /
    • pp.73-78
    • /
    • 2008
  • A polarimetric fiber-optic CT has been developed by using a sensing coil made of a length of sun fiber. A Faraday rotator mirror is attached to the end of the sensor coil to double the sensitivity and to suppress the residual linear birefringence effect. From the current measurements, the linear error no more than ${\pm}2[%]$ was obtained. The output of spun fiber sensor coil was compared with those of the twisted- and the flint glass fiber's, and it fumed out to almost 50 times, 2 times more sensitive, respectively.

The Expressive Characteristics of Fashion Installation in Henrik Vibskov Collection (헨릭 빕스코브 컬렉션에 나타난 패션 인스톨레이션의 표현 특성)

  • Ko, Hyunzin
    • Journal of the Korean Society of Costume
    • /
    • v.65 no.6
    • /
    • pp.133-147
    • /
    • 2015
  • The aim of this study is to review the creative fashion installation of Henrik Vibskov, Danish designer. Its intention is to contribute useful information for more innovative fashion presentation. As a research method, document and case study were performed and his collections from 2004 F/W to 2016 S/S were analyzed. In fashion installation, the designer puts objects in meaningful spaces in order to convey a certain message, to make an integrated artwork, and to interact with spectator. It has been used in fashion exhibitions, as well as in the set design of fashion performance and fashion show. The results were as follows. Henrik Vibskov's fashion installation has three features, which are 1)conceptual theme approach that communicates a twisted and metaphoric message, with a poetic and interesting show title, 2) surrealistic scenography that plays with fragmentation of the human body, clustering of plastic and symbolic objects, innovative color transformations, and visual trickery between figures and the background, and 3) setting for multisensory performance that makes spectators interact by making artistic objects and surroundings, which stimulates the five senses. Henrik Vibskov's fashion installation can exist as an independent artwork, and not just as a supporting piece for a fashion show. It has both artistic and fashionable values, and can be an effective fashion presentation communicating his conceptual fashion themes.

Stabilization of Fiber-optic Current Sensor Using a Faraday Rotator Mirror (Faraday 반사경을 이용한 광섬유형 전류센서의 안정화)

  • 김기혁;송민호
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.6
    • /
    • pp.72-76
    • /
    • 2003
  • We developed a polarimetric fiber-optic current sensor using a length of twisted fiber and a Faraday rotator mirror which was used to suppress the linear birefringence effect. A gold coated mirror was also used as the sensor coil reflector, and the results were compared with the case of FRM. From the experimental results, it is clear that the FRM greatly enhances the stability of the fiber optic current sensor output..