• Title/Summary/Keyword: Technology Subject

Search Result 2,876, Processing Time 0.028 seconds

Assessment of Anion Generation on the Isolated Trees at Summer (여름철 단일수목의 음이온 발생에 관한 평가)

  • Kim, Jeong-Ho;Seo, Yu-Hwan;Joo, Chang-Hun;Yoon, Yong-Han
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.42 no.4
    • /
    • pp.1-9
    • /
    • 2014
  • This research aims to analyze changes in anion according to locations through changes in the measuring point centering on a single tree. The subject tree was the Zelkova serrata which is most widely used as a landscape tree, and the measurement was conducted for a total of 3 days with summer solstice as the basic date. In consideration of the solar altitude and the location of the Zelkova serrata, a total of 4 measurement points - $T_a$ at the opposite direction of the shadow, $T_b$ in the center of the tree $T_c$ in the center of the shadow, and $T_d$ at the end of the shadow - were established. The mean temperature of the measurement days was the highest at $T_a$ with $28.4^{\circ}C$ and was the lowest at $T_c$, in the center of the shadow with $27.9^{\circ}C$. The relative humidity was the lowest with 42.5% at $T_a$ where the temperature was the highest. The amount of insolation was the highest at $T_a$ with $1,024.6W/m^2$, followed by $T_d(701.48W/m^2$), $T_c$($215.63W/m^2$), and $T_b(227.75W/m^2)$, and the anion was the highest at $T_a$ with $654ea/cm^3$, followed by $T_d$, $T_c$, and $T_b$, with $639.4ea/cm^3$, $615.3ea/cm^3$, $612.3ea/cm^3$, respectively. The results of the correlation analysis proved that anion correlated with the temperature, the amount of insolation, and the relative humidity on the significant level. Of these, the temperature and the amount of insolation had the positive correlation with the correlation coefficients of .687 and .332, respectively, and the significance probability of .000, and .037, respectively. The relative humidity was found to have negative correlation. Its correlation coefficient and the significance probability were -.557, and .000, respectively.

Packaging Technology for the Optical Fiber Bragg Grating Multiplexed Sensors (광섬유 브래그 격자 다중화 센서 패키징 기술에 관한 연구)

  • Lee, Sang Mae
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.24 no.4
    • /
    • pp.23-29
    • /
    • 2017
  • The packaged optical fiber Bragg grating sensors which were networked by multiplexing the Bragg grating sensors with WDM technology were investigated in application for the structural health monitoring of the marine trestle structure transporting the ship. The optical fiber Bragg grating sensor was packaged in a cylindrical shape made of aluminum tubes. Furthermore, after the packaged optical fiber sensor was inserted in polymeric tube, the epoxy was filled inside the tube so that the sensor has resistance and durability against sea water. The packaged optical fiber sensor component was investigated under 0.2 MPa of hydraulic pressure and was found to be robust. The number and location of Bragg gratings attached at the trestle were determined where the trestle was subject to high displacement obtained by the finite element simulation. Strain of the part in the trestle being subjected to the maximum load was analyzed to be ${\sim}1000{\mu}{\varepsilon}$ and thus shift in Bragg wavelength of the sensor caused by the maximum load of the trestle was found to be ~1,200 pm. According to results of the finite element analysis, the Bragg wavelength spacings of the sensors were determined to have 3~5 nm without overlapping of grating wavelengths between sensors when the trestle was under loads and thus 50 of the grating sensors with each module consisting of 5 sensors could be networked within 150 nm optical window at 1550 nm wavelength of the Bragg wavelength interrogator. Shifts in Bragg wavelength of the 5 packaged optical fiber sensors attached at the mock trestle unit were well interrogated by the grating interrogator which used the optical fiber loop mirror, and the maximum strain rate was measured to be about $235.650{\mu}{\varepsilon}$. The modelling result of the sensor packaging and networking was in good agreements with experimental result each other.

Why A Multimedia Approach to English Education\ulcorner

  • Keem, Sung-uk
    • Proceedings of the KSPS conference
    • /
    • 1997.07a
    • /
    • pp.176-178
    • /
    • 1997
  • To make a long story short I made up my mind to experiment with a multimedia approach to my classroom presentations two years ago because my ways of giving instructions bored the pants off me as well as my students. My favorite ways used to be sometimes referred to as classical or traditional ones, heavily dependent on the three elements: teacher's mouth, books, and chalk. Some call it the 'MBC method'. To top it off, I tried audio-visuals such as tape recorders, cassette players, VTR, pictures, and you name it, that could help improve my teaching method. And yet I have been unhappy about the results by a trial and error approach. I was determined to look for a better way that would ensure my satisfaction in the first place. What really turned me on was a multimedia CD ROM title, ELLIS (English Language Learning Instructional Systems) developed by Dr. Frank Otto. This is an integrated system of learning English based on advanced computer technology. Inspired by the utility and potential of such a multimedia system for regular classroom or lab instructions, I designed a simple but practical multimedia language learning laboratory in 1994 for the first time in Korea(perhaps for the first time in the world). It was high time that the conventional type of language laboratory(audio-passive) at Hahnnam be replaced because of wear and tear. Prior to this development, in 1991, I put a first CALL(Computer Assisted Language Learning) laboratory equipped with 35 personal computers(286), where students were encouraged to practise English typing, word processing and study English grammar, English vocabulary, and English composition. The first multimedia language learning laboratory was composed of 1) a multimedia personal computer(486DX2 then, now 586), 2) VGA multipliers that enable simultaneous viewing of the screen at control of the instructor, 3) an amplifIer, 4) loud speakers, 5)student monitors, 6) student tables to seat three students(a monitor for two students is more realistic, though), 7) student chairs, 8) an instructor table, and 9) cables. It was augmented later with an Internet hookup. The beauty of this type of multimedia language learning laboratory is the economy of furnishing and maintaining it. There is no need of darkening the facilities, which is a must when an LCD/beam projector is preferred in the laboratory. It is headset free, which proved to make students exasperated when worn more than- twenty minutes. In the previous semester I taught three different subjects: Freshman English Lab, English Phonetics, and Listening Comprehension Intermediate. I used CD ROM titles like ELLIS, Master Pronunciation, English Tripple Play Plus, English Arcade, Living Books, Q-Steps, English Discoveries, Compton's Encyclopedia. On the other hand, I managed to put all teaching materials into PowerPoint, where letters, photo, graphic, animation, audio, and video files are orderly stored in terms of slides. It takes time for me to prepare my teaching materials via PowerPoint, but it is a wonderful tool for the sake of presentations. And it is worth trying as long as I can entertain my students in such a way. Once everything is put into the computer, I feel relaxed and a bit excited watching my students enjoy my presentations. It appears to be great fun for students because they have never experienced this type of instruction. This is how I freed myself from having to manipulate a cassette tape player, VTR, and write on the board. The student monitors in front of them seem to help them concentrate on what they see, combined with what they hear. All I have to do is to simply click a mouse to give presentations and explanations, when necessary. I use a remote mouse, which prevents me from sitting at the instructor table. Instead, I can walk around in the room and enjoy freer interactions with students. Using this instrument, I can also have my students participate in the presentation. In particular, I invite my students to manipulate the computer using the remote mouse from the student's seat not from the instructor's seat. Every student appears to be fascinated with my multimedia approach to English teaching because of its unique nature as a new teaching tool as we face the 21st century. They all agree that the multimedia way is an interesting and fascinating way of learning to satisfy their needs. Above all, it helps lighten their drudgery in the classroom. They feel other subjects taught by other teachers should be treated in the same fashion. A multimedia approach to education is impossible without the advent of hi-tech computers, of which multi functions are integrated into a unified system, i.e., a personal computer. If you have computer-phobia, make quick friends with it; the sooner, the better. It can be a wonderful assistant to you. It is the Internet that I pay close attention to in conjunction with the multimedia approach to English education. Via e-mail system, I encourage my students to write to me in English. I encourage them to enjoy chatting with people all over the world. I also encourage them to visit the sites where they offer study courses in English conversation, vocabulary, idiomatic expressions, reading, and writing. I help them search any subject they want to via World Wide Web. Some day in the near future it will be the hub of learning for everybody. It will eventually free students from books, teachers, libraries, classrooms, and boredom. I will keep exploring better ways to give satisfying instructions to my students who deserve my entertainment.

  • PDF

The Effect of Home economic education teaching plans for students in academic and those in vocational high schools' 'Preparation for Successful aging' in the 'Family life in old age' unit -A comparative study between practical problem-teaching lesson plans and instructor-led teaching and learning plans- (인문계와 가사.실업 전문계 고등학생의 '성공적인 노후생활 준비교육'을 위한 가정과 수업의 적용과 효과 -실천적 문제 중심 수업과 강의식 수업을 중심으로-)

  • Lee, Jong-Hui;Cho, Byung-Eun
    • Journal of Korean Home Economics Education Association
    • /
    • v.23 no.4
    • /
    • pp.105-124
    • /
    • 2011
  • To achieve this objective, practical problem-teaching lesson plans and instructor-led teaching and learning plans were developed and integrated into the Technology Home Economics, and Human Development curricula at both academic and vocational high schools. The impact of these plans was examined, as were connections between the teaching methods and types of schools. As part of this study, a survey was conducted on 1,263 students in 46 classes at 6 randomly selected high schools: 4 academic and 2 vocational. A total of 9 teachers conducted classes for both experimental and comparative groups between October 2009 and November 2010. Pre- and post-tests were used to study the impact of the lessons on the experimental and comparative groups. In terms of data analysis and statistics processing, this study implemented mean and standard deviations, t-test, and analysis of covariance using the SPSS 12.0 program. The results of this study are as follows. The practical problem-teaching lessons produced more positive results in the students than the instructor-led lessons, in terms of their image of the elderly, their level of knowledge about them, their understanding of their need for welfare services, and preparation for Successful aging. When comparing the results by type of school, the experimental groups at academic high schools appeared to have a more positive image and better understanding of the elderly and their need for welfare services, and were better prepared for Successful aging than during their previous lessons. They also showed an increase in independence from their children in aging. As for the comparative groups, students at academic high schools showed an increase in preparation for Successful aging compared to the previous lessons. Finally, as for future research on preparation for aging in high schools, more schools should include this subject in their regular curriculum for Technology Home Economics, Human Development and Home Economics in order to generalize the results, and they need to evaluate the content. Additionally, this study suggests that new high school curricula should include lessons on preparation for aging so that students can deal successfully with our aging society.

  • PDF

The Comparison of Glomerular Filteration Rate by Kidney Depth in Dynamic kidney Scan (동적신장검사에서 신장깊이에 따른 사구체여과율 비교)

  • Hwang, Ju-Won;Lim, Young-Hyen;Yun, Jong-Jun;Lee, Hwa-Jin;Lee, Mu-Seok;Jung, Ji-Uk;Park, Se-Yun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.73-77
    • /
    • 2014
  • Purpose Find out about the significance of the GFR values calculated by the kidney depth is measured by comparing the values obtained for kidney depth was measured GFR in the CT image kidney depth and is calculated by Tonnesen law in $^{99m}Tc$-DTPA dynamic kidney scan with each applies. Materials and Methods Among patients with normal value (75~120 mL/min) computed GFR conducted of dynamic renal scan to visit from February 2013 to February 2014 and donor GFR values in patients with normal value. The mean age was 46.9 years with 14 men 13 females. We used abdomen CT image which checked before conducting dynamic Kidney scan for measuring the depth of kidney. We only used CT image that contains renal hilum and measured outermost front of the kidney from the skin surface (a) and the final surface (b) caculated the average depth of [(a + b) / 2] respectively. Using the same ROI in order to limit the change in GFR values by the other additional element was set before and after the depth value was excluded from the GFR falls kidney disease. Results Using Tonnesen law the average value was caculated 5.94 cm from the right kidney 5.90 cm from the left kidney. It was 6.83 cm, 8.71 cm in the left kidney and the right kidney average value of the depth measured on the basis of the CT image. The respective increase in left kidney 0.93 cm and right kidney 2.77 cm calculated on the basis of CT image actually measured values. GFR was calculated as the average depth of the subject calculated by the method Tonnesen $83.3{\pm}9.79mL/min$. $98.6{\pm}14.07mL/min$ GFR was applied to calculate the average depth of the subjects using the CT image, is the difference appears 15.26 mL/min was increased after seting up depth value, P value was less than 0.01 which is significant. Conclusion The difference between GFR before-after setting up depth value cause that the different of depth value. Is a measured depth of the extension value of the calculated estimates Whereas Tonnesen kidney depth method is to use in calculating the value of GFR in a typical dynamic elongation test depth derived using the CT image depth. Is thought to be able to calculate more accurately the GFR value by the distance to the center of kidney more accurately measured in the skin thereby.

  • PDF

The Analysis of Blood Glucose Level Difference According to the Exact Use of Blood Glucose Measurement Test Strips in $^{18}F$-FDG Wholebody PET ($^{18}F$-FDG를 이용한 전신 PET 검사에서 혈당 측정 검사지의 정확한 사용에 따른 혈당 수치의 차이 분석)

  • Park, Soon-Ki;Lee, Nam-Ki;NamGung, Chang-Kyung;Jung, Woo-Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.100-103
    • /
    • 2010
  • Purpose: $^{18}F$-FDG wholebody PET is to evaluate the tumor using glucose metabolism. The blood glucose level is important factor that affects on a result of examination. High glucose levels may interfere with tumor targeting due to competitive inhibition of FDG uptake by D-glucose. The blood glucose level measurement test strips used in the blood glucose measurement are classified into the capillary blood measurement test strips and general purpose measurement test strips that can measure the venous blood and capillary blood altogether depends on cases. The purpose of the study was to compare the blood glucose measurements between simultaneously obtained capillary and venous blood samples using the capillary blood measurement test strips, general purpose measurement test strips. Materials and Methods: A total of 46 subjects (32 males, 14 females) with a mean age of $57.3{\pm}12.3$ years were enrolled. The blood glucose estimation was performed with a Optium Xceed Glucometer (Abbott). Simultaneous capillary and venous blood samples were obtained from each subject. The blood glucose levels were measured using the capillary blood measurement test strips and general purpose measurement test strips. The capillary and venous measurements were compared using a pared t-test. Results: The mean capillary and venous glucose values using the general purpose measurement test strips were $95.2{\pm}12.4$ mg/dL and $104.1{\pm}14.4$ mg/dL, giving a statistically significant difference (p<0.001) between the mean values for the capillary and venous glucose samples (9.0 mg/dL; 95% confidence interval (CI) -11.2 to -6.7). The mean capillary and venous glucose values using the capillary blood measurement test strips were $91.5{\pm}13.6$ mg/dL and $108.6{\pm}16.2$ mg/dL, giving a statistically significant difference (p<0.001) between the mean values for the capillary and venous glucose samples (16.6 mg/dL; 95% CI -20.2 to -13.0). Conclusion: When measuring the blood glucose level before $^{18}F$-FDG PET examination, since the incorrect blood glucose level can be measured, it should note to measure the blood glucose level of the venous blood by the capillary blood measurement test strips. Therefore the measurement variation can be reduced to fulfill the standardized measurement procedure with the suitable measurement test strips, the preparation of the PET examination will be able to be clearly confirmed. In addition, the standardized procedure of the following measurement on the area which is same at all times the blood area in the blood glucose measurement among a capillary or a vein will be needed.

  • PDF

Utility Evaluation of Two-point Calibration Curve applied for TSH, FT4 Tests (TSH, FT4 검사의 Two-point Calibration Curve 적용의 유용성 평가)

  • Park, Hye-Mi;Yoo, Seon-Hee;Lee, Seon-Ho;Kim, Nyun-Ok
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.75-79
    • /
    • 2016
  • Purpose The ASAN Medical Center, Nuclear Medicine performs TSH (Thyroid stimulating hormone) and FT4 (Free Thyroxine) tests 8 times per day. Accordingly, 70 ~ 80 kit tubes are consumed every day for the measurements and the time consumed for reagent dispensing averages over 170 seconds, where the TAT (turnaround time) may be effected when the number of test samples is larger than expected. Therefore, the following test was conducted with the purpose to reduce the number of kit tubes consumed, and reduce the time for reagent dispensing. Materials and Methods The test is based on applying the same reagent for tests where the number of samples is 30 or less. The test for TSH was conducted 9 times from July $1^{st}$ 2015 to July $10^{th}$ 2015. The test for FT4 was conducted 4 times from June $18^{th}$ 2015 to June $22^{nd}$, 2015. Standard Solution No.2 (0.153 uU/mL) and No.5 (4.96 uU/mL) was selected as the two-point standards for the TSH test, and Standard Solution No.3 (0.777 ng/dL) and No.4 (2.044 ng/dL) was selected as the two-point standards for the FT4 test. 38 test samples were subject to correlation analysis. Results For TSH, the result of the normal test shows ranges of 0.20 ~ 0.37 uU/mL for Control1, 0.53 ~ 0.71 uU/mL for Control2, and 6.77 ~ 7.94uU/mL for Control3, while the result of two-point calibration curve test shows ranges of 0.18 ~ 0.27 uU/mL for Control1, 0.53 ~ 0.71 uU/mL for Control2, and 7.30 ~ 8.52 uU/mL for Control3. For FT4, the result of the normal test shows ranges of 0.85 ~ 0.94 ng/dL for Control1 and 4.23 ~ 4.57 ng/dL for Control2, while the result of two-point calibration curve test shows ranges of 0.61 ~ 0.75 ng/dL for Control1 and 3.88 ~ 5.71 ng/dL for Control2. For TSH, the CV% of the normal test for Control1, Control2 and Control3 are 10.5, 3.3 and 3.6 respectively, while the CV% of the two-point calibration curve test for Control1 and Control1 are 12.4, 8.2 and 5.1 respectively. The result shows an outstanding correlation of TSH: y = 0.9985x - 0.0459 $R^2=0.9986$. For FT4, the CV% of the normal test for Control1 and Control2 are 0.70 and 0.71 respectively, while the CV% of the two-point calibration curve test for Control1 and Control1 are 8.7 and 16.2 respectively. The result shows an outstanding correlation of FT4: y = 1.2674x - 0.1133 $R^2=0.9824$. Conclusion The two-point calibration curve can be efficiently applied for TSH in cases where the number of test samples is not large, since the number of samples to be re-tested increases when the result is abnormal from the calibration curve. The two-point calibration curve test should not be applied for FT4 where the results do not consistently comply with the quality assessment range. Depending on how the two-point calibration curve is applied, up to 5 test tubes can be conserved per test, and the reduced time for reagent dispensing is anticipated to have a positive effect on the TAT (turnaround time).

  • PDF

Method to Reduce the Activity Loss and Pain when Injecting 18F-Florbetaben (18F-Florbetaben 주사 시 Activity 손실과 통증 감소를 위한 방법)

  • Kwon, Hyeong Jin;Choi, Jin Wook;Lee, Hyeong Jin;Woo, Jae Ryong;Kim, Yoo Kyeong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.42-45
    • /
    • 2016
  • Purpose Neuracep is used to other diagnostic evaluations of the brain to estimate beta-amyloid neuritic plaque density in adult patients with cognitive impairment and inspected cognitive impairment. $^{18}F-Florbetaben$ specially has moderate lipophilicity and property of the added ethanol. It is the subject of interest of the patient pain and residual activity after injecting. Our study is effective injection method of the radiopharmaceutical and patient care. So it is for the highest quality image. Materials and Methods Patients were targeted 70 subjects, it was injected mean $259{\pm}74MBq$ to the patients ($^{18}F-FDG$: 20 subjects, $^{18}F-FP-CIT$: 20 subjects, $^{18}F-Florbetaben$: 30 subjects). After injection (reflusing 2 times, reflusing 3 times) using a 3-way set, it measured the residual activity. When injecting $^{18}F-Florbetaben$, we evaluated the effective injection methods(3-way set method and heparin cap method). The average residual activity after the injection was compared using a statistical analysis of SPSS 12.0(ANOVA, t-test analysis). Also, elemental analysis was performed on $^{18}F-Florbetaben$ by GC (Gas Chromatography). Results When reflusing 2 times measured residual activity as follows ($^{18}F-FDG$: 1.48 MBq, $^{18}F-FP-CIT$: 7.4 MBq, $^{18}F-Florbetaben$: 32.6 MBq). And when reflusing 3 times measured residual activity as follows ($^{18}F-FDG$: 1.85 MBq, $^{18}F-FP-CIT$: 3.7 MBq, $^{18}F-Florbetaben$: 36.3 MBq). There was a significant difference when reflusing 2 times(P < 0.05) and reflusing 3 times (P < 0.05). But when reflusing 3 times, there was no significant difference relation FDG and FP-CIT (P > 0.05). $^{18}F-Florbetaben$ Residual activity according to the injection method was a significant difference (P < 0.05). GC analysis results were measured ethanol: 207665 ppm and acceton: 377.4 ppm. Conclusion $^{18}F-Florbetaben$ was high residual activity compared to FDG and FP-CIT. Heparin cap method was effective when $^{18}F-Florbetaben$ was injected. $^{18}F-Florbetaben's$ ethanol component analysis was highly measured. So it is recommended that inject to 6 sec/ml or more in order to reduce the pain.

  • PDF

A Study on the Influence of Conflict on the Performance and Validity of Organization (갈등이 조직성과 및 조직 유효성에 미치는 영향에 대한 연구)

  • 기호익
    • The Journal of Information Technology
    • /
    • v.1 no.2
    • /
    • pp.81-102
    • /
    • 1998
  • It is common description that modern society is In the era of limitless competition. In order to challenge the change of economy and its management at home and abroad, organization should be changed anew, and in this case, there accompanies conflict or trouble whether the subject of change wants it or not. Therefore, according to change, we should concern with settlement of small troubles as well as big ones, and by managing the conflict or trouble productively and originally, it should be utilized as new fatality and chance to develop something in organization. In the system organized by people, there exist various conflicts in accordance with the target and want of the system, therefore giving no freedom to each Individual member of the system, and this is an unavoidable tate in consideration of the modem society where the survival of mankind and human systems should be guaranteed. Therefore, it determines the coordinates of success of any of organizations to manage conflict or trouble well, and so, when decreasing or increasing conflicts so that the organization exerts its full influence, it is note worthy that conflict itself should be rationally and efficiently managed. In a view point of the theory of organization and its behavior, relating job satisfaction with the performance and validity of organization, the influence of individual conflict is so great on the rate of job transfer within an organization or nonattendance, even on the productivity of the organization. So, the manager to cope with conflict within an organization should devise following three plans to manage conflict for job satisfaction and conflict settlement. In conclusion, it is suggested that in order to manage conflict within an organization well, some plans to control conflict should be well utilized while giving more efforts to improving management of individual conflict, job satisfaction, validity of organization, productivity, etc and all the members of organization should remember that the Issue of conflict within an organization be recognized ad an opportunity of new development and a way to settle a trouble within an organization, and a direction of conflict management should be suggested so that new innovation ca be created.

  • PDF

A Study of Factors Affecting Measurement of Kidney Size in Ultrasonography (초음파로 신장의 크기 측정 시 미치는 영향에 관한 연구)

  • Yoon, Seok-Hwan;Kim, Yun-Min;Choi, Jun-Gu
    • Journal of radiological science and technology
    • /
    • v.31 no.2
    • /
    • pp.161-169
    • /
    • 2008
  • Since measuring the size of kidney with sonography becomes an important index for diagnosis, treatment, and prognostic prediction in kidney disease, the accurate measurement and evaluation on this are clinically very important. Accordingly, the purpose of this study was to increase reproducibility and objectivity in measuring the size of kidney by enumerating factors that have an impact for measurement. It targeted 44 adults in Korea at the age of 21-27. It measured in order for both kidneys to be seen most largely while changing a subject-examiner's position in a state of fasting for 8 hours and a transducer's approaching direction. It compared a size of kidney by measuring, respectively, with the same method in 30 minutes and in 1 hour after drinking water in 700-1,000cc. In case of the lateral approach scan in decubitus position, the average length of the kidney both to the right and the left and the deviation of measurement to be the largest. In NPO(None Per Oral) state, the average length in the right kidney was 10.19cm, and the average length in the left kidney was 10.33cm. In 60 minutes after taking moisture, the average length in the right kidney was 10.94cm, and the average length in the left kidney was 11.13cm. In comparing the average length of the kidney in NPO state and its average length in 60 minutes after taking moisture, the size swelled by 7.3% for the length in the right kidney and by 7.7% in the left, thereby having been indicated to be statistically significant(P<0.003). The measurement in a size of kidney by using ultrasound may be measured differently depending on a patient's state of taking moisture and a transducer's approaching direction. It is thought that when the measurement in a size of kidney is especially important clinically, the intake and intake time in moisture need to be considered and that measuring with the posterior approach in prone position is a good method aiming to increase reproducibility in measuring length of the kidney.

  • PDF