Abstract
This research aims to analyze changes in anion according to locations through changes in the measuring point centering on a single tree. The subject tree was the Zelkova serrata which is most widely used as a landscape tree, and the measurement was conducted for a total of 3 days with summer solstice as the basic date. In consideration of the solar altitude and the location of the Zelkova serrata, a total of 4 measurement points - $T_a$ at the opposite direction of the shadow, $T_b$ in the center of the tree $T_c$ in the center of the shadow, and $T_d$ at the end of the shadow - were established. The mean temperature of the measurement days was the highest at $T_a$ with $28.4^{\circ}C$ and was the lowest at $T_c$, in the center of the shadow with $27.9^{\circ}C$. The relative humidity was the lowest with 42.5% at $T_a$ where the temperature was the highest. The amount of insolation was the highest at $T_a$ with $1,024.6W/m^2$, followed by $T_d(701.48W/m^2$), $T_c$($215.63W/m^2$), and $T_b(227.75W/m^2)$, and the anion was the highest at $T_a$ with $654ea/cm^3$, followed by $T_d$, $T_c$, and $T_b$, with $639.4ea/cm^3$, $615.3ea/cm^3$, $612.3ea/cm^3$, respectively. The results of the correlation analysis proved that anion correlated with the temperature, the amount of insolation, and the relative humidity on the significant level. Of these, the temperature and the amount of insolation had the positive correlation with the correlation coefficients of .687 and .332, respectively, and the significance probability of .000, and .037, respectively. The relative humidity was found to have negative correlation. Its correlation coefficient and the significance probability were -.557, and .000, respectively.
본 연구는 단일수목 중심으로 측정지점의 변화를 통해 위치에 따른 음이온 변화를 분석하고자 하였다. 연구대상지는 건국대학교 글로컬캠퍼스 내에 위치한 느티나무를 선정하여 하지를 기준으로 총 3일간 측정을 실시하였으며, 그림자가 형성되는 반대 방향에 위치한 $T_a$지점과 수목의 중앙에 위치시킨 $T_b$지점, 그림자 중앙에 위치시킨 $T_c$지점, 그림자 끝 지점에 위치시킨 $T_d$지점으로 총 4개소로 구분하여 측정하였다. 측정일 간 평균기온은 $T_a$지점이 $28.4^{\circ}C$로 가장 높았으며, 그림자 중앙에 위치시킨 $T_c$지점이 가장 낮은 $27.9^{\circ}C$로 나타났다. 상대습도는 기온이 가장 높았던 $T_a$지점에서 가장 낮은 42.5%를 기록하였다. 일사량의 경우 $T_a$지점에서 $1,024.6W/m^2$로 가장 높았으며, $T_d$지점($701.48W/m^2$) > $T_c$지점($215.63W/m^2$) > $T_b$지점($227.75W/m^2$) 순으로 조사되었고, 음이온 측정결과, $T_a$지점에서 가장 높은 $654ea/cm^3$로 측정되었으며, $T_d$지점 > $T_c$지점 > $T_b$지점 순으로 각각 $639.4ea/cm^3$, $615.3ea/cm^3$, $612.3ea/cm^3$로 나타났다. 상관성 분석결과, 음이온은 세 가지 기상요소, 기온, 일사량, 상대습도와 상관성이 검증되었다. 기온과 일사량의 경우 정의 상관성을 보이고, 각각 .687과 .332의 상관계수를 보였으며, 유의확률은 .000, .037로 나타났다. 또한 상대습도는 부의 상관관계로 상관계수와 유의확률이 각각 -.557, .000으로 분석되었다.