The Analysis of Blood Glucose Level Difference According to the Exact Use of Blood Glucose Measurement Test Strips in $^{18}F$-FDG Wholebody PET

$^{18}F$-FDG를 이용한 전신 PET 검사에서 혈당 측정 검사지의 정확한 사용에 따른 혈당 수치의 차이 분석

  • Received : 2010.09.02
  • Accepted : 2010.09.16
  • Published : 2010.10.30

Abstract

Purpose: $^{18}F$-FDG wholebody PET is to evaluate the tumor using glucose metabolism. The blood glucose level is important factor that affects on a result of examination. High glucose levels may interfere with tumor targeting due to competitive inhibition of FDG uptake by D-glucose. The blood glucose level measurement test strips used in the blood glucose measurement are classified into the capillary blood measurement test strips and general purpose measurement test strips that can measure the venous blood and capillary blood altogether depends on cases. The purpose of the study was to compare the blood glucose measurements between simultaneously obtained capillary and venous blood samples using the capillary blood measurement test strips, general purpose measurement test strips. Materials and Methods: A total of 46 subjects (32 males, 14 females) with a mean age of $57.3{\pm}12.3$ years were enrolled. The blood glucose estimation was performed with a Optium Xceed Glucometer (Abbott). Simultaneous capillary and venous blood samples were obtained from each subject. The blood glucose levels were measured using the capillary blood measurement test strips and general purpose measurement test strips. The capillary and venous measurements were compared using a pared t-test. Results: The mean capillary and venous glucose values using the general purpose measurement test strips were $95.2{\pm}12.4$ mg/dL and $104.1{\pm}14.4$ mg/dL, giving a statistically significant difference (p<0.001) between the mean values for the capillary and venous glucose samples (9.0 mg/dL; 95% confidence interval (CI) -11.2 to -6.7). The mean capillary and venous glucose values using the capillary blood measurement test strips were $91.5{\pm}13.6$ mg/dL and $108.6{\pm}16.2$ mg/dL, giving a statistically significant difference (p<0.001) between the mean values for the capillary and venous glucose samples (16.6 mg/dL; 95% CI -20.2 to -13.0). Conclusion: When measuring the blood glucose level before $^{18}F$-FDG PET examination, since the incorrect blood glucose level can be measured, it should note to measure the blood glucose level of the venous blood by the capillary blood measurement test strips. Therefore the measurement variation can be reduced to fulfill the standardized measurement procedure with the suitable measurement test strips, the preparation of the PET examination will be able to be clearly confirmed. In addition, the standardized procedure of the following measurement on the area which is same at all times the blood area in the blood glucose measurement among a capillary or a vein will be needed.

$^{18}F$-FDG PET 검사는 포도당 대사를 이용하여 전신의 종양을 평가하는 검사로 전처치 과정에서 혈당 측정의 중요성이 매우 높다. 혈당 수치가 높은 상태에서 FDG를 투여하면 FDG와 혈중 포도당이 세포 내 흡수에 서로 경쟁하게 되고 종양으로의 FDG 섭취가 감소되어 정확한 검사가 되지 않을 가능성이 있다. 혈당 측정에 사용되는 혈당 측정 검사지는 경우에 따라 모세혈관혈 전용 측정 검사지와 모세혈관혈과 정맥혈을 모두 측정 가능한 범용 측정 검사지로 구분되어 있는데, 정확한 혈당 측정 검사지(스트립)의 사용에 따른 혈당 수치의 차이를 비교 분석 하였다. 연구 대상은 2010년 3월부터 4월까지 서울아산병원 핵의학과에서 $^{18}F$-FDG whole body PET 검사를 시행한 환자 중 46명(남자: 32명, 여자: 14명, 평균연령 $57.3{\pm}12.3$세) 을 연구의 대상으로 하였다. 실험기기는 Abbott사의 Optium Xceed혈당 측정기를 이용하였고, 모세혈관혈과 정맥혈을 모두 측정 가능한 범용 측정 검사지를 사용하여 동일 환자의 모세혈관혈과 정맥혈의 혈당 수치의 차이를 분석하였다. 또한, 모세혈관혈 전용 측정 검사지를 사용하여 동일 환자의 모세혈관혈과 정맥혈의 혈당 수치의 차이를 비교 분석하였다. 분석방법은 MINITAB 통계 프로그램을 이용하여 paired t-test 검정을 시행하였다. 모세혈관혈과 정맥혈을 모두 측정 가능한 범용 측정 검사지로 측정한 동일 환자의 모세혈관혈과 정맥혈의 혈당 수치는 각각$95.2{\pm}12.4$ mg/dL, $104.1{\pm}14.4$ mg/dL (t=8.0, p<0.001)로 통계적으로 유의한 차이가 있었다. 모세혈관혈 전용 측정 검사지로 측정한 동일 환자의 모세혈관혈과 정맥혈의 혈당 수치는 각각 $91.5{\pm}13.6$ mg/dL, $108.1{\pm}16.2$ mg/dL (t=9.2, p<0.001)로 통계적으로 유의한 차이가 있었다. 선행연구에 의하면 모세혈관혈과 정맥혈의 혈당 수치는 여러 가지 이유로 인해 차이가 있는 것으로 보고 되었고 본 연구의 결과도 유사한 차이를 확인하였다. $^{18}F$-FDG PET 검사 전에 혈당 수치를 측정할 때 모세혈관혈 전용 측정 검사지로 정맥혈의 혈당을 측정하는 것은 부정확한 혈당 수치를 측정할 수 있으므로 주의해야 할 것이다. 그러므로 적합한 측정 검사지와 규정된 측정절차를 이행하는 것이 측정 편차를 줄일 수 있어 PET 검사의 전처치를 보다 명확하게 확인할 수 있을 것이다. 또한, 혈당 측정 시에 혈액 채취 부위를 모세혈관 또는 정맥혈관 중에서 항상 동일한 부위에서 측정하는 등의 표준화 과정이 필요할 것이다.

Keywords