• Title/Summary/Keyword: Tear film

Search Result 60, Processing Time 0.027 seconds

Comparison of tear film break-up time and high order aberration according to soft contact lens material (소프트콘택트렌즈 재질에 따른 눈물막 파괴시간과 고위수차의 비교)

  • Kim, Bong-Hwan;Han, Sun-Hee;Kim, Hak-Jun;Bae, Sang-A;Son, Yu-Jin;Kim, Ji-Hyun;KIm, Hyun-Ji
    • Journal of Korean Clinical Health Science
    • /
    • v.7 no.1
    • /
    • pp.1232-1237
    • /
    • 2019
  • Purpose. In this study, two types of soft contact lenses with different materials were selected to compare the time of tear film destruction and high order aberrations before and after wearing. Methods. Thirty patients (60 eyes) in their 20s were included in this study. Two lenses with different materials, Group 4 (Etafilcon A) and Group 5 (Narafilcon A) were selected. Using aberration analyzer and keratometry, high-order aberration and tear film test (NIF-BUT, NIAvg-BUT) were performed before and after wearing. Results. When comparing the higher aberrations of the Etafilcon A and Narafilcon A lenses, the higher aberrations of the Narafilcon A lens were higher overall. For the initial tear film break-up time (NIF-BUT) after wearing, the Etafilcon A lens was reduced by 4.0 seconds and the Narafilcon A lens increased by 0.6 seconds. For the mean tear film break-up time (NIAvg-BUT) after wearing, the Etafilcon A lens decreased by 2.4 seconds and the Narafilcon A lens increased by 1.7 seconds. Conclusions. NIF-BUT and NIAvg-BUT of Narafilcon A lens were increased. The lens with relatively low water content and higher oxygen permeability than the lens with high water content has relatively less tear evaporation, which means that the time of destruction of the tear film is increased.

The Effect of Circle Contact Lens on the Stability of Tear Film (써클콘택트렌즈가 눈물막 안정성에 미치는 영향)

  • Lee, Sehee;Hyung, Sung Min;Koh, Seung Hwan;Park, Mijung;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.2
    • /
    • pp.125-131
    • /
    • 2015
  • Purpose: The effect of pigmentation in circle contact lens on lens wearers' tear film stability was investigated in this study. Methods: Non-invasive tear film break-up times of 54 normal eyes before and after lens wearing in twenties and the portion of first tear breakup were measured. The frontal and back surface roughness of circle contact lens was further observed with a scanning electron microscope. The clear lens which was made of hilafilcon B and circle contact lenses which were made of hilafilcon B, polymacon and copolymer of HEMA NVP were tested. Results: Non-invasive tear film breakup time was significantly reduced compared with it before lens wearing. In some case, statistically significant difference in tear film breakup time was also observed between circle contact lenses. The tear file break-up was usually early started in lower than upper portion, and in temporal than nasal portion although there was variation in the lens material. The tear film break-up of circle contact lenses made of hilafilcon B was more commonly observed in peripheral portion(pigmented area) compared with clear contact lens made of same material. Conclusions: The present study revealed that the stability of tear film was affected by wearing circle contact lens and the result seems to be used as the basis for the problem solving that can occur due to the pigmentation when wearing circle contact lens.

The Difference in Tear Film Stability between Normal and Dry Eyes by Wearing Clear and Circle Contact Lenses made of the Same Materials (동일 재질의 투명 및 써클콘택트렌즈 착용 시 정상안과 건성안의 눈물막 안정성 차이)

  • Lee, Sehee;Park, Mijung;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.1
    • /
    • pp.11-21
    • /
    • 2016
  • Purpose: The aim of this study was to analyze the difference in tear film stability according to the wearing time when wearing clear and circle soft contact lens(circle lens) made of same material. Methods: The clear and circle contact lenses of hilafilcon B and nelfilcon A materials were respectively applied on the subjects classified as normal and dry eyes depending on their tear volume, and their tear film stability was investigated by measuring the non-invasive tear film break-up times, lens centration and the first appearing area of tear breakup after 30 mins and 6 hrs of lens wearing. Results: Non-invasive tear film breakup time significantly reduced with increase of the wearing time for normal and dry eyes when wearing clear and circle contact lenses. The starting ratio of tear film break-up was higher at the peripheral area of clear and circle lenses in all two different materials, and higher at the peripheral area of dry eyes than normal eyes. Starting ratio of tear film break-up was higher at the peripheral area of nelfilcon A lenses compared with hilafilcon B lenses, however, its change with the increase of wearing time showed a different aspect. The number of tear film break-up per unit area when wearing circle lenses of nelfilcon A increased at the central area with the wearing time while its number was higher at the peripheral area when wearing circle lenses of hilafilcon B. The centration of clear lenses made of two materials was closer to pupil compared to circle lenses with the increase of wearing time, however, a larger decentration was shown in dry eyes compared with normal eyes. Conclusions: The research revealed that an effect on tear film stability may be changed by clear lenses as well as circle lenses with coloring process according to the increase of wearing time, and the factors affecting on tear film stability may also vary depending on lens materials. Thus, the appropriate lenses should be selected by the consideration of lens material as well as coloring method/dyes according to the wearers' habit such as daily wearing time and wearing period when trying to wear clear and circle lenses.

The Difference of Tear Break-Up Time by the Fitting States of Soft Contact Lens in Normal and Dry Eyes (정상안과 건성안에서 소프트렌즈 피팅 상태에 따른 비침입성 눈물막 파괴 시간의 차이)

  • Jung, Da I;Lee, Heum Sook;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.4
    • /
    • pp.339-346
    • /
    • 2010
  • Purpose: The study was performed to compare the difference of non-invasive tear break-up time (NIBUT) with alignment or steep fitting of soft contact lens in normal and dry eyes. Methods: Total 40 eyes (aged 20~30 years) were classified to the normal (n=20) or dry eye group (n=20) by the diagnosis methods for dry eyes and worn soft contact lens (polymacon material) with alignment or steep fitting. NIBUTs of lens wearers were separately measured at the points of before wearing, immediately after wearing and after stabilization of tear film. Results: With alignment fitting, averaged NIBUT in the dry eye group after stabilization of tear film was not significantly different from that of the normal eye group. However, averaged NIBUTs in the normal and dry eyes had significant difference when measured immediately after lens wearing. However, the number of eyes having NIBUT less than 4.0 second was 30% higher compared to the number of normal eyes with steep fitting when measured immediately after wearing. Some shorten NIBUT in dry eyes with steep fitting was also shown after stabilization of tear film. Conclusions: These results suggest that wearing soft contact lens in dry eyes differently affect tear film compared to normal eyes. Thus, dry eyes need more advertent fitting for contact lens wearing because of unstable tear film.

Study on the Physical Property of Stretch Film for Wrapping of Roughage (조사료 래핑용 스트레치 필름의 물리적 특성에 관한 연구)

  • 이성현;장유섭;박원규;최광재;김종근
    • Journal of Animal Environmental Science
    • /
    • v.5 no.2
    • /
    • pp.79-86
    • /
    • 1999
  • Recently more dairy farmers are interested in the utilization of stretch film for wrapping silage material. Most of stretch film are imported from abroad and one domestic product was developed, but its quality has not yet been tested. Therefore this study was executed to offer basic data on this material to the farmers. Measured items were tensile load, extension ratio, and tear propagation strength of stretch films. Comparisons were made among the white color of domestic product(Kw), and white(Fw), black (Fb) and green color(Fg) of foreign products. The result were summarized as follows: 1. Tensile loads of lengthwise direction in stretch films were 557.4, 377.4, 282.6 and 398.4kgf/$\textrm{cm}^2$ in Kw, Fw, Fb and Fg, respectively, and tensile loads of width direction were 415.9, 418.1, 360.2 and 433.0kgf/$\textrm{cm}^2$ in Kw, Fw, Fb and Fg, respectively. 2. Extension ratios of lengthwise direction were 650, 462.5, 512.5% and 537.5% in Kw, Fw, Fb and Fg, respectively, Extension ratios of width direction were 930, 962.5, 950 and 1,000% in Kw, Fw, Fb and Fg, respectively. 3 Tear propagation strength of lengthwise direction 187.9, 148.9, 157.3 and 142.8kgf/cm, and tear propagation strength of width direction were 141.4, 129.8, 140.4 and 106.6kgf/cm in Kw, Fw, Fb and Fg, respectively. 4. In the light transmittance, there was no difference between white and green color stretch film, but it was very low in black one. Therefore, it is thought that research on quality of roll bale silage treated with each stretch film would be needed.

Microvascular autologous submandibular gland transplantation in severe cases of keratoconjunctivitis sicca

  • Su, Jia-Zeng;Cai, Zhi-Gang;Yu, Guang-Yan
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.37
    • /
    • pp.5.1-5.4
    • /
    • 2015
  • Dry eye syndrome is a relatively common disease of the tears and ocular surfaces that results in discomfort, visual disturbance, and tear film instability with possible damage to the ocular surfaces. Microvascular submandibular gland (SMG) transfer offers a surgical alternative for a permanent autologous substitution of tears using the basal secretion of a transplanted SMG. Long-term follow-up reveals that this technique is a lasting and effective solution for patients with severe dry eye syndrome. The uncomfortable symptoms were relieved, and the frequency of use of pharmaceutical tear substitutes was reduced. Objective examination showed significant improvement in tear film and some features of ocular surface such as breakup time of tear film and corneal staining. Patients may suffer from obstruction of Wharton's duct or epiphora after surgery. Activation of secretion-related receptors could improve the early hypofunction of the denervated SMG and prevent the duct obstruction. Reduction surgery, partial SMG transplantation, uses of atropine gel or Botulinum toxin A could be the choices of treatment for epiphora.

A Study on the Confidence of Dry Eye Diagnosis Methods (건성안 검사 방법의 신뢰도에 대한 연구)

  • Lee, Byeong Jun;Hong, Jae Hyeon;Jung, Dai;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.1
    • /
    • pp.15-20
    • /
    • 2008
  • Purpose: To study on the confidence of dry eye diagnosis methods which need to prescribe contact lens. Methods: Non-invasive tear film break-up time (NIBUT) and tear film break-up time (TBUT) were measured in forty healthy subjects in their 20s, and then the subjects were classified into normal eye and dry eye. The results of McMonnies questionnaire, tear prism height measurement, Hardtack test, blink rate measurement and Schirmer test were compared with the results of NIBUT and TBUT. Results: The results of NIBUT and TBUT were as follows; 20 subjects had normal eyes, 10 subjects had dry eyes in both NIBUT and TBUT, and 10 subjects showed different results. In McMonnies questionnaire, the score of normal eye group averaged 8.2 and that of dry eye group averaged 18.5, which showed statistically significant difference. Furthermore, 100% of normal eye group classified by the results of NIBUT and TBUT corresponded with the result of McMonnies questionnaire and 90% of dry eye group showed the correspondence. Tear prism height of normal eye group averaged 0.32 mm and that of dry eye group averaged 0.23 mm, which were significantly different. Hardtack test, blink rate measurement and Schirmer test without local anesthesia showed no statistically significant difference between normal eye group and dry eye group. Conclusions: On dry eye diagnosis methods, the results of McMonnies questionnaire and tear prism height measurement had close correlation with the results of NIBUT and TBUT.

  • PDF

The differences of tear film for young Korean of a day indoor space (실내 공간 내에서 한국인 청년의 하루 중 눈물층 변화)

  • Oh, Hyun Jin;Lee, Ji-Young
    • Journal of Digital Convergence
    • /
    • v.10 no.11
    • /
    • pp.535-540
    • /
    • 2012
  • This study is to research the differences of tear film for young people in of a day in a restricted indoor space. The subjects are 58 eyes volunteers for twice preliminary inspection and tear test of a day. 58 healthy individuals with no eye disease, no body disease, orthophoria, corrective visual acuity more than 0.8, binocular spherical equivalence difference over 0.50 diopter, the flattest corneal curvature in horizontal meridian and the steepest corneal curvature in vertical meridian were tested. The uncorrective visual acuity, refractive error, corneal curvature, schirmer test and tear break up test were performed in the morning and afternoon. Schirmer test were $16.0{\pm}7.0mm$ in the morning and $14.1{\pm}7.1mm$ in the afternoon. TBUT were $11.3{\pm}0.6$ sec in the morning and $12.1{\pm}0.9$ sec in the afternoon. They have no significant differences.

Evaluation of Tear Film Lipid Layer Thickness Measurements Obtained Using an Ocular Surface Interferometer in Nasolacrimal Duct Obstruction Patients

  • Lee, Sang Min;Chung, Sok Joong;Lew, Helen
    • Korean Journal of Ophthalmology
    • /
    • v.32 no.6
    • /
    • pp.445-450
    • /
    • 2018
  • Purpose: To compare the tear film lipid layer thickness (LLT) between patients with incomplete nasolacrimal duct obstruction (NLDO) and normal controls and to analyze the changes in tear film LLT and blinking pattern after silicone tube intubation in NLDO patients. Methods: We reviewed the medical records of 68 eyes in 52 incomplete NLDO patients who underwent silicone tube intubation from January 2017 to July 2017. The LLT, blinking pattern, and Meibomian gland image were measured with the LipiView II ocular surface interferometer. The Meibomian gland drop-out ratio was measured using the polygon selection tool in the Image J program. Tear meniscus height, which is the other lacrimal indicator, was assessed with spectral-domain optical coherence tomography. Results: Tear meniscus height was significantly decreased after silicone tube intubation (p < 0.01). Preoperative minimum, maximum, and average LLT values were $62.4{\pm}24.0$, $86.7{\pm}17.9$, and $71.7{\pm}23.3nm$, respectively. Significant changes in the minimum, maximum, and average LLT ($74.8{\pm}23.6$, $98.8{\pm}11.0$, and $91.6{\pm}16.1nm$, respectively) were observed after silicone tube intubation (p < 0.001, p = 0.001, and p < 0.001). The partial blinking/total blinking ratio in 20 seconds and the Meibomian gland drop-out ratio showed no significant change after silicone tube intubation. Conclusions: Overall, the LLT was increased after silicone tube intubation. Silicone tube intubation may be helpful in maintaining LLT with a normalized of amount of tears.

The effect of synovium graft on conjunctiva in rabbit model of dry eye

  • Park, Keungjin;Nam, Kyungmin;Jang, Min;Lee, Won-Jae;Jeong, Seong Mok;Bae, Seulgi;Kwon, Young-Sam;Ku, Sae-Kwang;Yun, Sungho
    • Journal of Animal Reproduction and Biotechnology
    • /
    • v.36 no.1
    • /
    • pp.59-68
    • /
    • 2021
  • This study was performed to identify the effect of synovium graft on conjunctiva in rabbits after dry eye induction. Six New Zealand White rabbits were used as dry eye models. Both eyes were divided to two groups as control and synovium graft group. The synovium graft was performed in fourth week after dry eye modeling. Quantitative change of tears through Schirmer tear test (STT), qualitative change of tear film through tear film break up time (TFBUT), and damage of cornea through fluorescein staining were observed for 10 weeks at intervals of two weeks. Histological examination was performed to evaluate cornea and conjunctiva at tenth week. In both groups, STT and TFBUT were significantly decreased in 4 weeks after modeling compared to 0 weeks (p < 0.05) . After synovium graft, there were increases in STT value at 4 weeks and TFBUT at 4 and 6 weeks in graft group (p < 0.05). Corneal fluorescein staining showed no significant difference between the two groups. In histopathological examination, grafted synovium was detected as round to ovoid ingression folds, well attached to grafted regions with 0.11 ± 0.04 mm2 (range, 0.05-0.16 mm2). These results indicated that the synovium graft on the conjunctiva had an effect on the qualitative and quantitative improvement of the tear film even though there was no histological change.