• Title/Summary/Keyword: TM-S

Search Result 1,203, Processing Time 0.032 seconds

A Study on Generation and Operation of Dynamic Pattern at Micro-stereolithography using $DMD^{TM}$ ($DMD^{TM}$를 이용한 마이크로 광 조형 시스템에서 다이나믹 패턴 생성 및 구동에 관한 연구)

  • Kim H.S.;Choi J.W.;Ha Y.M.;Kwon B.H.;Won M.H.;Lee S.H.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1214-1218
    • /
    • 2005
  • As demands for precision parts are increased, existing methods to fabricate them such as MEMS, LIGA technology have the technical limitations like high precision, high functionality and ultra miniaturization. A micro-stereolithography technology based on $DMD^{TM}$(Digital Micromirror Device) can meet these demands. In this technology, STL file is the standard format as the same of conventional rapid prototyping system, and 3D part is fabricated by stacking layers that are sliced as 2D section from STL file. Whereas in conventional method, the resin surface is cured as scanning laser beam spot according to the section shape, but in this research, we use integral process which enables to cure the resin surface at one time. In this paper, we deal with the dynamic pattern generation and $DMD^{TM}$ operation to fabricate micro structures. Firstly, we address effective slicing method of STL file, conversion to bitmap, and dynamic pattern generation. Secondly, we suggest $DMD^{TM}$ operation and optimal support manufacturing for $DMD^{TM}$ mounting. Thirdly, we examine the problems on continuous stacking layers, and their improvements in software aspects.

  • PDF

A STUDY ON THE SHEAR BOND STRENGTHS AND MICROLEAKAGES OF THREE BONDING AGENTS ON DENTIN (상아질 접착제의 전단결합강도와 미세누출에 관한 연구)

  • Kim, Jeong-Ho;Cho, Young-Gon;Moon, Joo-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.2
    • /
    • pp.680-692
    • /
    • 1997
  • New bonding agent systems have been supplied which operators can simply apply to conditioned tooth surfaces. The purpose of this study was to evaluate the shear bond strengths and the microleakages of three bonding agents and composite resins to dentin. Seventy-five extracted human maxillary and mandibular molar teeth were used in this study. For the shear bond strength test, the entire occlusal dentin surfaces of thirty teeth were exposed with Diamond Wheel Saw and smoothed with Lapping and Polishing Machine (South Bay Technology Co., U.S.A). For the microleakage test, Class V cavities were prepared in the buccal surfaces of fourtyfive teeth. They were randomly assigned into 3 groups according to dentin bonding agents ($Scotchbond^{TM}$ Multi-Purpose plus, ONE-$STEP^{TM}$ and Prime & $Bond^{TM}$)and composite resins (Z-100, $Aelitefil^{TM}$ and TPH $Spectrum^{TM}$) to be used. Bonding agents and composite resins were bonded to exposed dentin surfaces of the tooth crown and to Class V cavities on the buccal surfaces respectively according to manufacturer's directions. The shear bond strengths were measured by universal testing machine($U^{TM}$ AGS-100, Japan). In addition, the degree of micro leakage at the occlusal and gingival margin was examined by 2 % methylene blue and stereomicroscope(Olymous SZH 10, Japan). The results were as follows: 1. The shear bond strength to dentin was the highest value in SBMP-Plus group($16.68{\pm}7.38$ MPa) and the lowest value in Prime & Bond group($11.61{\pm}5.82$ MPa), but there was no significant difference of shear bond strength among three groups. 2. The degree of microleakage at both occlusal and gingival margin was showed the lowest in SBMP-Plus group and the highest in ONE-STEP group. 3. At both occlusal and gingival margin, there was significant difference of microleakage between SBMP-Plus and ONE-STEP/ Prime & Bond groups(p<0.05), but no significant difference of microleakage between ONE-STEP and Prime & Bond group(p>0.05).

  • PDF

Effect of Catalyst and Reactive Toughening Aid on the Fractography of Carbon/BMI ($\pm$45。)2s Matrix (촉매와 반응성 내충격성 증진제의 Carbon/BMI ($\pm$45。)2s 매트릭스의 파단특성에 영향)

  • 김준형
    • The Korean Journal of Rheology
    • /
    • v.3 no.1
    • /
    • pp.30-37
    • /
    • 1991
  • 제 2세대 bismaleimide의 일종인 Boots Technochemie 사의 Compimide 800을 매트 릭스 수지로 선정하여 여기에 촉매(DABCO 0.2wt%) 및 반응성 내충격성 증진제(TM 120; 15. 30, 60 part)를 첨가하여 Carbon/BMI 적층판($\pm$ 45。)2s를 만들어 인장 시험을 하여 in-plane shear하에서의 파단특성을 조사하였다, 이경우에 전단 탄성율을 망목상구조의 특성 에 의해 좌우되고 전단강도는 파단면의 형태와 밀접합 관계가 있다. TM 120을 30 part 첨 가한 경우의 전단강도가 가장 우수하였다

  • PDF

SHEAR BOND STRENGTH OF SELF-ETCHING ADHESIVES TO TOOTH ENAMEL WITH ADDITIONAL ETCHING (부가적 산부식 시간에 따른 자가 산부식 접착제의 법랑질 전단결합강도)

  • Lee, Hyung-Sook;Kim, Sung-Ki;Lee, Dong-Soo;Kim, Shin;Jeong, Tae-Sung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.36 no.4
    • /
    • pp.514-521
    • /
    • 2009
  • The aim of this study was to evaluate the bonding ability of two self etch systems to human primary and permanent enamel and the effect of additional acid etching time. Exfoliated, caries free human primary molar(n=65) and permanent molar extracted (n=65) were used. prepared enamel specimens were randomly divided into 2 test groups and a control group. The control group(n=10) were treated with 35% phosphoric acid gel and Scotchbond Multi-purpose adhesive. Experimental groups(self-etching systems) were subdivided into 6 groups(each n=10) according to additional etching time(0s, 5s, 10s, 15s, 20s, 30s). The result were as follows : 1) The shear bond strengths of the self-etching adhesives(Clearfil SE Bond, Adper Prompt L-pop) without additional etching were lower than control group(Scotch Bond Multipurpose). 2) Between the same self-etch adhesive groups, additional etched groups showed higher shear bond strength 3) There was no significant difference between primary and permanent enamel. In conclusion, bond strength of self-etch adhesives to enamel could be increased with additional etching.

  • PDF

Skin Whitening Effects of Angelica koreana and Cnidium monnieri Extracts (강활과 벌사상자 추출물의 피부 미백효과)

  • Cho, Wan Goo;Kim, Cheong Tack
    • Journal of Digital Convergence
    • /
    • v.12 no.4
    • /
    • pp.419-425
    • /
    • 2014
  • The objective of this study is to estimate the inhibition of skin melanin formation by extract of Angelica koreana and Cnidium monnieri and the possibility of functional cosmetic materials through anti-irritation and stability test. The extract used in this experiment is White-$AK^{TM}$ and the INCI name is Osthole. The main component of White-$AK^{TM}$ was identified as coumarin and EC50 value was 2.7ppm by mouse melanoma B 16 cell test. White-$AK^{TM}$ showed inhibitory effects 100 times lower concentration than arbutin. The main mechanism for skin whitening effect thought to be inhibition of tyrosinase-related gene expression. The basic essence formulation of White-$AK^{TM}$ 5% solution applied to the skin showed the effect of relieving skin irritation. White-$AK^{TM}$ in an opaque container, under UV conditions for 4 weeks, and showed close to 100% recovery and 97% recovery under $50^{\circ}C$ for 4 weeks. Therefore, it is thought that White-$AK^{TM}$ which helps skin whitening, relieving skin irritation and stable in UV condition is able to be used as the functional component in the cosmetic formulation.

Dyeability and Colorfastness of Knitted Fabrics with Natural Dye PinuxTM (Part II) -Improvement of Colorfastness Using Cationizing Agent and Smectite-

  • Jung, Jong Sun;Song, Kyung Hun
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.36 no.12
    • /
    • pp.1310-1317
    • /
    • 2012
  • This study examines the possibilities to improve natural dyestuff's (Pinux$^{TM}$) dyeability and colorfastness for C/R (Cotton/Rayon (40/60)) and W/T (Wool/Tencel (10/90)) knitted fabrics in cationizing and smectiting for pre-treatment, simultaneous-treatment and post-treatment process sequences; as well as various other treatment methods. The sample dyeability showed the strongest K/S value in the order of smectite (S) < cationization + smectite (C+S) < cationization (C); however, the K/S value showed a low level in the simultaneoustreatment method of smectite. Colorfastness to washing improved in the order of C < C+S < S, and after the smectite post-treatment process, C/R improved from Grade 1 to Grade 4 and W/T improved from Grade 1-2 to Grade 4. Colorfastness to perspiration generally improved in the same order as the colorfastness to washing and after the smectite post-treatment process C/R, W/T sample's acidic and alkaline colorfastness to perspiration improved greatly. As for the colorfastness to rubbing, the addition of smectite in the simultaneous-treatment and post-treatment processes resulted in improved wet-colorfastness; however, smectite showed less effect on the colorfastness to light compared to other colorfastness ratings.

Difference in Rotation Pattern of Toric Soft Contact Lenses with Different Axis Stabilization Design (축 안정화 디자인이 상이한 토릭소프트콘택트렌즈의 회전 양상 차이)

  • Park, So Hyun;Kim, Dong Yeon;Choi, Joo Hee;Byun, Hyun Young;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.2
    • /
    • pp.133-140
    • /
    • 2015
  • Purpose: It was investigated whether two different stabilization designs of toric contact lenses changed the rotational axis and degree of toric lenses according to body posture and gaze direction in the present study. Methods: Toric soft contact lenses with Lo-Torque$^{TM}$ design and ASD design (accelerated stabilized design) were fitted on 52 eyes aged in 20s-30s. Then, rotational degree was measured at the five gaze directions including front gaze and the lying position. Results: When gazing the front and vertical directions in the upright posture, lens was much rotated to nasal side for the Lo-Torque$^{TM}$ design and temporal side for the ASD design. When gazing horizontal direction, both design lenses were rotated against to the gaze direction. Rotation degree was the smallest at superior direction gaze and the largest at nasal gaze. In case of the rotation degree less than $5^{\circ}$, Lo-Torque$^{TM}$ design was more frequent when gazing front and vertical directions, and ASD design was more frequent when gazing horizontal direction. In addition, the lens with Lo-Torque$^{TM}$ design was lesser rotation degree than with ASD design immediately after lying. On the other hand, the lens with ASD design was lesser rotation degree than with Lo-Torque$^{TM}$ design 1 minute later after lying. Conclusions: This study confirmed that axis rotation of the lens induced by gaze direction and posture was different according to axis stabilization design during wearing toric soft contact lens.

Simulation and Control of the Molten Carbonate System using Aspen $Dynamics^{TM}$ and ACM (Aspen $Dynamics^{TM}$와 ACM을 이용한 용융탄산염 연료전지 시스템의 모사 및 제어)

  • Jeon, Kyoung Yein;Kwak, Ha Yeon;Kyung, Ji Hyun;Yoo, Ahrim;Lee, Tae Won;Lee, Gi Pung;Moon, Kil Ho;Yang, Dae Ryook
    • Korean Chemical Engineering Research
    • /
    • v.49 no.4
    • /
    • pp.423-431
    • /
    • 2011
  • Recentincreasing awareness of the environmental damage caused by the $CO_2$ emission of fossil fuelsstimulated the interest in alternative and renewable sources of energy. Fuel cell is a representative example of hydrogen energy utilization. In this study, Molten Carbonate Fuel Cell system is simulated by using $Aspen^{TM}$. Stack model is consisted of equilibrium reaction equations using $ACM^{TM}$(Aspen Custom Modeler). Balance of process of fuel cell system is developed in Aspen $Plus^{TM}$ and simulated at steady-state. Analysis of performance of the system is carried out by using sensitivity analysis tool with main operating parameters such as current density, S/C ratio, and fuel utilization and recycle ratio.In Aspen $Dynamics^{TM}$, dynamics of MCFC system is simulated with PID control loops. From the simulation, we proposed operation range which generated maximum power and efficiency in MCFC power plant.

THE EFFECTS OF THERMOCONDENSATION TECHNIQUE USING SYSTEM BTM ON THE PERIODONTIUM (System BTM를 이용한 열가압 충전시의 치주인대내에 미치는 영향)

  • Kim, Jae-Wook;Lee, Seung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.1
    • /
    • pp.366-378
    • /
    • 1998
  • Thermocondensation root canal filling technique have been used to fill accessary canals or to obtain homogeneous root caral fillings. But these thermocondensation technique inevitably produce heat in the canal which can be transmitted through the dentin and cementum and consequently damage periodontal ligamental cells and osteoblasts. In this study, System $B^{TM}$(Analytic technology, WA.D.S.A.) was used to evaluate the reaction of periodontal ligament tissue to "Continous Wave condensation technique" introduced by Buchanan, and the transmitted root surface temperature was measured according to measured root thicknesses. 12 Mandibular incisors of two adult dogs were used for the experiment. 6 controls were filled by lateral condensation technique with sealer.3 specimens were apically filled by Continuous Wave technique at $200^{\circ}C$ for 5 seconds and remaining 3 specimens were additionally backfilled using System $B^{TM}$(Analytic technology, WA.D.S.A.) was used to evaluate the reaction of periodontal ligament tissue to "Continous Wave condensation technique" introduced by Buchanan, and the transmitted root surface temperature was measured according to measured root thicknesses. 12 Mandibular incisors of two adult dogs were used for the experiment. 6 controls were filled by lateral condensation technique with sealer.3 specimens were apically filled by Continuous Wave technique at $200^{\circ}C$ for 5 seconds and remaining 3 specimens were additionally backfilled using System $B^{TM}$ at $100^{\circ}C$ for 20 seconds. Six weeks later, the dogs were sacrificed and the teeth stained with Hematoxylin and Eosin for histologic examination. 6 extracted human teeth were used to measure the transmitted temperature. After cutting off the crown, the canals were prepared and divided into 3 groups with root thickness of 1.5mm, 1.0mm, 0.5mm, 2 teeth in each group. Inside each root canal, System $B^{TM}$ was heated as with the temperature for the apically condensed and the back filled group, and the transmitted heat was measured on the external surface of the root. The temperature of System $B^{TM}$ heat spreader at $200^{\circ}C$ and $100^{\circ}C$ was also measured at root temperature. It can be concluded as follows: 1. In the thin area (200-$250{\mu}m$) of the root, root resorption could be seen even with heating at $200^{\circ}C$ for 5 seconds. 2. When the spreader was heated at $200^{\circ}C$ for 5 seconds and additionally at $100^{\circ}C$ for 20 seconds for backfill, all teeth showed root resorption regardless of their root thickness. 3. The transmitted external root surface temperature was higher as the root thickness decreased and as the heating time increased. In the thermocompaction technique using System $B^{TM}$, the spreader should be heated for the minimal time and used only in the apical area. The heated spreader shouldn't inserted to the binding point of the canal and backfilling should be done with other means of minimally heated gutta percha technique.

  • PDF

LymphanaxTM Enhances Lymphangiogenesis in an Artificial Human Skin Model, Skin-lymph-on-a-chip (스킨-림프-칩 상에서 LymphanaxTM 의 림프 형성 촉진능)

  • Phil June Park;Minseop Kim;Sieun Choi;Hyun Soo Kim;Seok Chung
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.50 no.2
    • /
    • pp.119-129
    • /
    • 2024
  • The cutaneous lymphatic system in humans plays a crucial role in draining interstitial fluid and activating the immune system. Environmental factors, such as ultraviolet light and natural aging, often affect structural changes of such lymphatic vessels, causing skin dysfunction. However, some limitations still exist because of no alternatives to animal testing. To better understand the skin lymphatic system, a biomimetic microfluidic platform, skin-lymph-on-a-chip, was fabricated to develop a novel in vitro skin lymphatic model of humans and to investigate the molecular and physiological changes involved in lymphangiogenesis, the formation of lymphatic vessels. Briefly, the platform involved co-culturing differentiated primary normal human epidermal keratinocytes (NHEKs) and dermal lymphatic endothelial cells (HDLECs) in vitro. Based on our system, LymphanaxTM, which is a condensed Panax ginseng root extract obtained through thermal conversion for 21 days, was applied to evaluate the lymphangiogenic effect, and the changes in molecular factors were analyzed using a deep-learning-based algorithm. LymphanaxTM promoted healthy lymphangiogenesis in skin-lymphon-a-chip and indirectly affected HDELCs as its components rarely penetrated differentiated NHEKs in the chip. Overall, this study provides a new perspective on LymphanaxTM and its effects using an innovative in vitro system.