• Title/Summary/Keyword: Supply Side

Search Result 703, Processing Time 0.026 seconds

Economic Evaluation Algorithm of Energy Storage System using the Secondary Battery (이차전지를 이용한 전기저장장치(BESS)의 경제성 평가 알고리즘)

  • Song, Seok-Hwan;Kim, Byung-Ki;Oh, Seung-Teak;Lee, Kye-Ho;Rho, Daeseok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.6
    • /
    • pp.3813-3820
    • /
    • 2014
  • Recently, with the increase in electrical consumption and the unbalanced power demand and supply, the power reserve rate is becoming smaller and the reliability of the power supply is deteriorating. Under this circumstance, a Battery Energy Storage System (BESS) is considered to be an essential countermeasure for demand side management. On the other hand, an economic evaluation is a critical issue for the introduction of a power system because the cost of BESS is quite high. Therefore, this paper presents economic evaluation method for utility use by considering the best mix method and successive approximation method, and an economic evaluation method for customer use by considering the peak shaving function based on the real time price. From a case study on a model power system and educational customer, it was confirmed that the proposed method is a practical tool for the economic analysis of BESS.

Change of Clinical Effect upon Use of Glutamine to Critically Ill Patients over Age 60 Receiving TPN (정맥영양 투여 받는 60세 이상 중환자에서 glutamine 사용에 따른 임상 효과의 변화)

  • Lee, Hye Seung;Kim, Sungtae;Min, Young Sil;Sohn, Uy Dong
    • Korean Journal of Clinical Pharmacy
    • /
    • v.24 no.1
    • /
    • pp.9-14
    • /
    • 2014
  • Background: It is known to reduce the mortality when glutamine is supplied to patients during the surgery or in intensive care unit through intravenous nutrition supply. The purpose of this study is to establish the appropriate basis for use of glutamine and guidelines of nutrition supply for critically ill patients in the hospital by examining the clinical effects of administration of glutamine with subjects of elderly critically ill patients receiving intravenous nutrition in one hospital in Korea. Method: Among elderly patients with age of 60 or more hospitalized in Yeuido St. Mary's Hospital from August 2012 to July 2013, those who stayed in the intensive care unit for more than a week and received TPN (Total Parenteral Nutrition) for more than 3 days during staying in the intensive care unit were classified to a test group using glutamine and a control group without glutamine. Duration of use of mechanical ventilator, duration of hospitalization, occurrence of infectious disease and death were compared between two groups. We would like to identify the clinical test figures affected by the use of glutamine by examining changes in SCr, Total Protein, Albumin, AST, ALT, TB, DB and GFR at the time of admission and discharge. Results: At the time of admission to intensive care unit, gender, physical measurement information and clinical test figures did not show any significant difference between 72 subjects in a test group and 24 subjects in a control group. Thus, two groups began in the same condition. There were no significant difference in duration of hospitalization, duration of intensive care unit, use of mechanical ventilator, occurrence of infectious disease and death. As the results of statistical analysis of the average changes of clinical test figures at the time of admission and discharge of intensive care unit, SCr and GFR were significantly changed in the test group. GFR was significantly changed in a control group. As the result of analysis of the clinical test figures at the time of discharge with reflection of average changes after clinical test figures were corrected at the time of admission of intensive care unit, TB and GFR were significantly increased in a test group compared with those in a control group. Other clinical test figures were not significantly changed. Conclusion: If glutamine is administered to critically ill patients over age 60 receiving TPN and careful monitoring for total bilirubin is made in the future, it is expected to give the positive effect on renal function andminimize the side effect of arise in total bilirubin.

The Function or Urban River and Sustainable Regional Development : The Case of Kumho River (도시하천과 지속가능한 지역 발전 : 금호강을 중심으로)

  • Choi, Byung-Doo
    • Journal of the Korean association of regional geographers
    • /
    • v.10 no.4
    • /
    • pp.757-774
    • /
    • 2004
  • This paper is to reclassify systematically the functions of urban river: that is, water supply, land management, transportation and energy source as social and economic function; formation of geomorphic surface, water-side landscape, community constitution and boundary and separation between regions as spatial function; and drainage of waste water, purification, habitation, and weather regulation as ecological function. On the basis of this reclassification, it can be argued that the socio-economic functions (eg. water supply) of the river among the functions of the river have been strongly mobilized in the process of modernization, while the spatial function and ecological function of urban river have been ignored. The Kumho river which flows through Daegu and the adjacent area has made a great contribution to the modem development process of the river basin area, but as a result of a selective development of a specific function of the river, that is the social and economic function, it now suffers from the lack of instream flow and is deprived of its original functions with the water pollution and degradation. Moreover the Daegu region seems no longer possible to develop on the dependence of the river. In order to overcome this kind of social and environmental crisis, this paper is to suggest both some principles and main evaluating indicators to restore the original and comprehensive functions of the river, and important measures to make the co-evolution of the city and the river possible.

  • PDF

An analysis on Flicker Phenomenon of a Fluorescent lights for the commercial operating EMU (영업운행 전동차 객실형광등의 플리커(Flicker) 현상에 관한 분석 연구)

  • Ha, Jong-Eun;Han, Seon-Ho;Park, Jae-Hong;Lee, Dae-Won
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.1240-1246
    • /
    • 2006
  • Generally, there are two types of main factors to affect output power quality of a auxiliary power supply an EMU(electric multiple unit). One is a voltage flicker by amplitude modulation of short time and air compressors. The other is repetitive motion of large capacity motor such as air compressors, HVAC unit etc. in main factors. This paper compared two kinds of fluorescent lamp, 32W (after remodeling interior) and 40W(before remodeling interior) and measured the light output varying input power(AC220V) for a flicker phenomenon related power supply of lamps in EMU. Also, we analyzed a flicker considering EMU operating time and density in order to grasp main factors of a load change to cause a voltage change. As a results of test, a 40W fluorescent lamp was more insensitive with 20.26% degree an eye recognition degree sides about changes of the input power and lower with 19.9% voltage side generating flicker compare with fluorescent lamp 32W. Also, we confirmed the fact which the fluorescent lamp flicker was generated by varying fluorescent lamp output voltage when the commercial EMU was in high driving density and at the busy time. Additionally, we confirmed the frequency band which an EMU passenger could feel sensitively blinking of a fluorescent lamp was visually $8Hz{\sim}15Hz$.

  • PDF

Study of Failure Examples for Emission Gas Control System in Gasoline Engine (가솔린 엔진 배출가스 제어장치에 대한 고장사례 고찰)

  • Lee, Il Kwon;Lee, Jong Ho;Lee, Young Suk;Youm, Kwang Wook;han, Jae Oh;Lim, Ha young
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.6
    • /
    • pp.37-42
    • /
    • 2016
  • The purpose of this paper is to study for the emission gas control of passenger car. The first example, the PCSV never open when operating condition, but it opened by causing malfunction because of trouble. As a result, the purge gas entered into surge tank, a mount of fuel was displayed with excessive supply on tester. Therefore, it certified the bad-condition of the engine when idling by decreasing of fuel injection quantity from engine ECU. The second example, the hose activating a EGR valve didn't supply the vacuum pressure because of assembling the other part. Thus, it knew the bad-condition of engine that the EGR valve would not work normally by leaking with the other port. The third example, as the rear oxygen sensor of two sensor were fault-installing by changing the sensor of other a car it could not detect of oxygen quantity. Finally, it found the phenomenon of abruptly decreasing vehicle speed when braking a car. Therefore, the system including with emission control has to drastically manage by maximizing condition to role decreasing the emission gas.

Hybrid Energy Storage System with Emergency Power Function of Standardization Technology (비상전원 기능을 갖는 하이브리드 에너지저장시스템 표준화 기술)

  • Hong, Kyungjin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.2
    • /
    • pp.187-192
    • /
    • 2019
  • Hybrid power storage system with emergency power function for demand management and power outage minimizes the investment cost in the building of buildings and factories requiring emergency power generation facilities, We propose a new business model by developing technology that can secure economical efficiency by reducing power cost at all times. Normally, system power is supplied to load through STS (Static Transfer Switch), and PCS is connected to system in parallel to perform demand management. In order to efficiently operate the electric power through demand forecasting, the EMS issues a charge / discharge command to the ESS as a PMS (Power Management System), and the PMS transmits the command to the PCS controller to operate the system. During the power outage, the STS is rapidly disengaged from the system, and the PCS becomes an independent power supply and can supply constant voltage / constant frequency power to the load side. Therefore, it is possible to secure reliability through verification of actual system linkage and independent operation performance of hybrid ESS, By enabling low-carbon green growth technology to operate in conjunction with an efficient grid, it is possible to improve irregular power quality and contribute to peak load by generating renewable energy through ESS linkage. In addition, the ESS is replacing the frequency follow-up reserve, which is currently under the charge of coal-fired power generation, and thus it is anticipated that the operation cost of the LNG generator with high fuel cost can be reduced.

Study on the Analysis of Spatial Structure in Jeju Island Focusing on Parking Status (주차실태를 중심으로 한 제주도 공간구조 분석 연구)

  • Hwang, Kyung-Soo;Yang, Jeong-Cheol;Jo, Hang-Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.2
    • /
    • pp.667-675
    • /
    • 2021
  • The purpose of this study is as follows: First, to analyze the spatial structure of Jeju by analyzing the rate of parking demand and supply; Second, to determine the parking service imbalance between regions; and third, to elucidate the causes of this spatial structural parking service imbalance and provide effective measures. Due to the rapid population and tourism growth, Jeju is suffering from traffic congestion and serious parking problems. For this, the ways to efficiently utilize the existing parking spaces were identified through spatial structure analysis based on the parking demand and supply in the Jeju area. As short-term policy, the following changes were proposed: switching to small-scale eup or myeon blocks of parking space, use of shared parking system, and repairing side streets in residential areas. As mid-to-long-term policy, it is linked to other means of transportation as follows: parking demand management policy through modal share by reorganizing public transportation routes or expanding traffic facilities; securing park-and-ride lots; and different parking pricing for different time periods. To implement these policies, each area of the public sector, private sector, and private-public partnership should develop the bond of sympathy by areas and participants.

Water Physiology of Panax ginseng. 1. Habitat observation. cultural experience, weather factors and characteristics of root and leaf (인삼의 수분생리 1. 자생지관찰.재배 경험.기상요인과 근 및 엽의 특성)

  • Park, Hoon
    • Journal of Ginseng Research
    • /
    • v.4 no.2
    • /
    • pp.197-221
    • /
    • 1980
  • Habitat observation, cultural experience of old and present plantation, weather factors in relation to crop stand and water physiology of root and leaf were reviewed. According to habitat observation ginseng plants love water but plate wit talus well grow at drained place with high moisture content in air and soil while ginseng plants were not found in dry or wet place. According to cultivation experience ginseng plants require abundant water in nursery and main field but most old planters believe that ginseng plaints are draught-loving thus require little water. The experience that rain especially in summer i.e unfavorable might be due to mechanical damage of leaves arid leaf disease infection, or severe leaf fall which is caused by high air temperature and coinsided with rain. According to crop stand observation in relation to weather factors abunsant water increased each root weight but decreased total yield indicating tile increase of missing root rate. Rain in summer was unfavorable too. Though rain in June was favorable for high yield general experience that cloudy day and rain were unfavorable might be due to low light intensity under shade. Present leading planters also do loot consider the importance of water in main field. Water content is higher in top than in root and highest in central portion of root and in stem of top. For seedling the heavier the weight of root is tile higher the water content while it reveries from two years old. Water potential of intact root appeared to be -2.89 bar suggesting high sensitivity to water environment. Under water stress water content severly decreased only in leaf. Water content of leaf appeared to be 78% for optimum, below 72% for functional damage and 68% for perm anent wilting. Transpiration or curs Principally through stomata in lower side of leaf thus contribution of upper side transpiration decreased with the increase of intensity. Transpiration is greater in the leaves grown under high light intensity. Thus water content is lower with high light inte nsity under field condition indicating that light is probable cause of water stress in field. Transpiration reached maximum at 10K1ut The decrease of transpiration at higher temperature seems to be due to the decrease of stomata aperture caused by water stress. Severe decrease of photosynthesis under water stress seems to be principally due to functional damage which is not caused by high temperature and Partly due to poor CO2 supply. Water potential of leaf appeared to be -16.8 bar suggesting weakness in draught tolerance. Ginseng leaves absorb water under high humidity. Water free space of leaf disc is %mailer than that of soybean leaf and water uptake appears to be more than two steps.

  • PDF

A Study on the Hood Performance Improvement of Pickling Tank using CFD (전산유체역학을 이용한 산세조 후드 성능 개선에 관한 연구)

  • Jung, Yu-Jin;Park, Ki-Woo;Shon, Byung-Hyun;Jung, Jong-Hyeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.1
    • /
    • pp.593-601
    • /
    • 2014
  • In this study, we investigated the methods of improving the capturing ability of acid fume by assessing the performance of slot-type external hood installed on both sides of an open surface tank for acid washing process. A field survey and the results of computational fluid dynamics revealed that capturing performance of existing hoods is very poor. To solve such problem, 'push-pull hood' that pushes from one side of an open surface tank and pulls on the other side was suggested. The initial prediction was that if a push-pull hood is used, the acid fume of an acid-washing tank surface could be moved towards the hood through the push flow. However, this study has confirmed that if the push flow velocity becomes too high, it could spread to other areas due to flooding from the hood. Therefore, if the push air supply is maintained at around 25 $m^3/min$(push 10 m/s), proper control flow is formed on the surface of a tank and acid fume that stayed at the upper part of the tank is smoothly captured toward the hood, significantly enhancing the capturing performance.

A Study on the Characteristics Assessment and Fabrication of Distribution Board according to KEMC Standards (KEMC 규정에 의한 분전반의 제작 및 특성 평가에 관한 연구)

  • Lee, Byung-Seol;Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.31 no.3
    • /
    • pp.63-72
    • /
    • 2017
  • This study fabricated a low-voltage 10 circuit distribution board based on the KEMC (Korea Electrical Manufacturers Cooperative) 2102-610 standard and performed a characteristics assessment of the developed 10 circuit distribution board to secure product stability. The developed 10 circuit distribution board is designed to have the characteristics of insulation materials, as well as resistance to corrosion ultraviolet radiation and mechanical impact. The developed distribution board is fabricated to have an appropriate protection class of enclosure, electric shock prevention and protection circuits, switchgear and its components, internal electrical circuits and connectors, external conduct terminal, insulation characteristics, temperature rise test, heat resistance, etc. The developed 10 circuit distribution board consists of a single phase circuit and 3-phase circuits. It is possible to measure in real time the leakage current generated from the load distribution line by installing a sensor module at the load side of each of the branched switchgears. In addition, it is possible to increase a circuit according to the use and purpose of the load and to also manage and check the load in real time. Temperature rise tests were performed on the developed 10 circuit distribution board at 18 places including the inlet connection, main circuit and distribution circuit bus bars and bus bar supports, etc. The highest temperature of $65.3^{\circ}C$ was measured at the R-Phase of the connection of the MCCB power supply for the branch circuit bus bar and a temperature rise of $61.6^{\circ}C$ was measured at the T-Phase of the load side. When applying thermal stress to an MCCB for 6 hours at $180^{\circ}C$ using a heat resistant experimental device, it was found that the actuator lever was transformed and moved in the tripped state.