• Title/Summary/Keyword: Storage coefficient

Search Result 470, Processing Time 0.021 seconds

The Effects of Aprotinin Addition and Plastic Tube Usage for Glucagon Test Results (Glucagon 검사시 Aprotinin 첨가와 Plastic tube 사용이 미치는 영향)

  • Cho, Youn-Kyo;Choi, Sam-Kyu;Seo, So-Yeon;Shin, Yong-Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.117-120
    • /
    • 2011
  • Purpose: There are 3 warnings for Glucagon tests. First, EDTA tubes that already contain Aprotinin must be used for plasma collection. Second, for freezer storage of centrifuged plasma, glass tubes must be used. Last, glass tubes must be used for testing procedure. So we compared the glucagon results of next 3 situation to those of control group. First, We compared to results by tubes without Aprotinin and with aprotinin. Second, we compared to results by tubes(plastic vs glass) for plasma storage. Third, we compared to results by tubes(plastic vs glass) for testing. We tried to evaluate the results of the 3 different condition. Materials and Methods: 40 healthy adults were studied with normal results on the general medical check up and laboratory tests. We compared the results of 3 different condition belows: Blood were collected in EDTA tube containing aprotinin and plasma was stored in the glass tube for 3 days in a freezer and results were obtained by tests in the glass tubes. Results from EDTA plasma without aprotinin, results from platic tubes for freezer stroage, results from plastic tube when testing. Simple linear regression analysis and paired t-test using SPSS were done for statistical analysis. Commercial glucagon kit(RIA-method)which made by Siemens company were used. Results: Correlation coefficient between results of EDTA tubes with Aprotinin vs without Aprotinin was r=0.783 (p=0.064). Result of specimen in plastic tubes stored 3 days in a freezer showed lower value compared to those in glass tube(r=0.979, p=0.005). Also, results of testing in plastic tubes showed lower values than those testing in glass tubes. (r=0.754, p<0.001). Conclusion: It is recommended for glucagon determination to use EDTA tube with Aprotinin which is a inhibitor of protein breakdown enzyme. Results of plastic tube when storage and testing showed lower value than those of glass tubes, so it is recommended to store and test in glass tubes.

  • PDF

Study on the Dissolution of Sandstones in Gyeongsang Basin and the Calculation of Their Dissolution Coefficients under CO2 Injection Condition (이산화탄소 지중 주입에 의한 경상분지 사암의 용해반응 규명 및 용해 반응상수값 계산)

  • Kang, Hyunmin;Baek, Kyoungbae;Wang, Sookyun;Park, Jinyoung;Lee, Minhee
    • Economic and Environmental Geology
    • /
    • v.45 no.6
    • /
    • pp.661-672
    • /
    • 2012
  • Lab scale experiments to investigate the dissolution reaction among supercritical $CO_2$-sandstone-groundwater by using sandstones from Gyeongsang basin were performed. High pressurized cell system (100 bar and $50^{\circ}C$) was designed to create supercritical $CO_2$ in the cell, simulating the sub-surface $CO_2$ storage site. The first-order dissolution coefficient ($k_d$) of the sandstone was calculated by measuring the change of the weight of thin section or the concentration of ions dissolved in groundwater at the reaction time intervals. For 30 days of the supercritical $CO_2$-sandstone-groundwater reaction, physical properties of sandstone cores in Gyeongsang basin were measured to investigate the effect of supercritical $CO_2$ on the sandstone. The weight change of sandstone cores was also measured to calculate the dissolution coefficient and the dissolution time of 1 g per unit area (1 $cm^2$) of each sandstone was quantitatively predicted. For the experiment using thin sections, mass of $Ca^{2+}$ and $Na^+$ dissolved in groundwater increased, suggesting that plagioclase and calcite of the sandstone would be significantly dissolved when it contacts with supercritical $CO_2$ and groundwater at $CO_2$ sequestration sites. 0.66% of the original thin sec-tion mass for the sandstone were dissolved after 30 days reaction. The average porosity for C sandstones was 8.183% and it increased to 8.789% after 30 days of the reaction. The average dry density, seismic velocity, and 1-D compression strength of sandstones decreased and these results were dependent on the porosity increase by the dissolution during the reaction. By using the first-order dissolution coefficient, the average time to dissolve 1 g of B and C sandstones per unit area (1 $cm^2$) was calculated as 1,532 years and 329 years, respectively. From results, it was investigated that the physical property change of sandstones at Gyeongsang basin would rapidly occur when the supercritical $CO_2$ was injected into $CO_2$ sequestration sites.

A Study on the Analysis of Shipment Structure of Hallabong Tangor in Korea (한라봉의 출하구조 분석)

  • Ko, Seong-Bo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.7
    • /
    • pp.670-676
    • /
    • 2017
  • The purpose of this study is to analyze the shipbuilding structure of Hallabong Tangorover ten-day and monthly intervals, to determine whether the shipment control can stabilize and increase the income of Hallabong Tangor farmers by estimating and analyzing the price flexibility function of Hallabong, and to derive the policy implication. Looking at the overall market, the 1% increase in shipment volume indicates that the coefficient of price flexibility varies with time. The largest decline is in late December and early January. The dummy variable indicating the year in which the quality drops somewhat is statistically significant from March to May, and the average of them is -0.337%. This implies a greater importance for quality control and shipment control when quality is worse than good quality. The price flexibility, which indicates price changes due to 1% increase in monthly shipment volume of Hallabong Tangor, varies with time. The coefficient of price flexibility was the highest at -0.46 in December, but prices fell slightly due to quality improvement and the increase in special demand of New Year's demand, which was -0.33% in January, -0.261% in February, -0.307% in March, and -0.318% in April. Since then, the amount of storage has been gradually exhausted, and the price flexibility has fallen slightly to -0.243% in May and -0.236% in June. DUM02, which represents the year when more than 7 days after the New Year holidays are in February is from February to June (+). This indicates that the price decrease due to increase in volume is less than that in January when the New Year is in February. This indicates a greater necessity for shipment control when New Year holidays are in January.

Development of the Efficiency-Evaluation Model for the Mechanism of CO2 Sequestration in a Deep Saline Aquifer (심부 대염수층 CO2 격리 메커니즘에 관한 효율성 평가 모델 개발)

  • Kim, Jung-Gyun;Lee, Young-Soo;Lee, Jeong-Hwan
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.6
    • /
    • pp.55-66
    • /
    • 2012
  • The practical way to minimize the greenhouse gas is to reduce the emission of carbon dioxide. For this reason, CCS(Carbon Capture and Storage) technology, which could reduce carbon dioxide emission, has risen as a realistic alternative in recent years. In addition, the researcher is recently working into ways of applying CCS technologies with deep saline aquifer. In this study, the evaluation model on the feasibility of $CO_2$ sequestration in the deep saline aquifer using ANN(Artificial Neural Network) was developed. In order to develop the efficiency-evaluation model, basic model was created in the deep saline aquifer and sensitivity analysis was performed for the aquifer characteristics by utilizing the commercial simulator of GEM. Based on the sensitivity analysis, the factors and ranges affecting $CO_2$ sequestration in the deep saline aquifer were chosen. The result from ANN training scenario were confirmed $CO_2$ sequestration by solubility trapping and residual trapping mechanism. The result from ANN model evaluation indicated there is the increase of correlation coefficient up to 0.99. It has been confirmed that the developed model can be utilized in feasibility of $CO_2$ sequestration at deep saline aquifer.

Parameter estimations to improve urban planning area runoff prediction accuracy using Stormwater Management Model (SWMM) (SWMM을 이용한 도시계획지역 유출량 예측 정확도 향상을 위한 매개변수 산정)

  • Koo, Young Min;Seo, Dongil
    • Journal of Korea Water Resources Association
    • /
    • v.50 no.5
    • /
    • pp.303-313
    • /
    • 2017
  • In environmental impact assessments for large urban development projects, the Korean government requires analysis of stormwater runoff before, during and after the projects. Though hydrological models are widely used to analyze and prepare for surface runoff during storm events, accuracy of the predicted results have been in question due to limited amount of field data for model calibrations. Intensive field measurements have been made for storm events between July 2015 and July 2016 at a sub-basin of the Gwanpyung-cheon, Daejeon, Republic of Korea using an automatic monitoring system and also additional manual measurements. Continuous precipitation and surface runoff data used for utilization of SWMM model to predict surface runoff during storm events with improved accuracy. The optimal values for Manning's roughness coefficient and values for depression storage were estimated for pervious and impervious surfaces using three representative infiltration methods; the Curve Number Methods, the Horton's Method and the Green-Ampt Methods. The results of the research is expected to be used more efficiently for urban development projects in Korea.

Inter-basin water transfer modeling from Seomjin river to Yeongsan river using SWAT (SWAT을 이용한 섬진강에서 영산강으로의 유역간 물이동 모델링)

  • Kim, Yong Won;Lee, Ji Wan;Woo, So Young;Kim, Seong Joon
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.1
    • /
    • pp.57-70
    • /
    • 2020
  • This study is to establish the situation of inter-basin transfer from Seomjin river basin to Yeongsan river basin using SWAT (Soil and Water Assessment Tool). Firstly, the SWAT modeling was conducted for each river basin. After, the inter-basin transfer was established using SWAT reservoir operating parameters WURESN (Water Use Reservoir Withdrawn) and inlet function from Juam dam of Seomjin river basin to Gwangju stream of Yeongsan river basin respectively. Each river basin was calibrated and validated using 13 years (2005~2017) data of Seomjin- Juam dam reservoir storage (JAD), release, transfer and Yeongsan-Mareuk (MR) stream gauge station. The results of root mean square error RMSE, Nash-Sutcliffe efficiency NSE, and determination coefficient R2 of JAD were 2.22 mm/day, 0.62 and 0.86 respectively. The RMSE, NSE, and R2 of MR were 1.38 mm/day, 0.69 and 0.84 respectively. To evaluate the downstream effects by the transferred water, the water levels of 2 multi-function weirs (SCW, JSW) in Yeongsan river basin and the Gokseong (GS) and Gurye (GR) stream gauge stations in Seomjin river basin were also calibrated. The RMSE, NSE, and R2 of SCW, JSW, GS and GR were 1.49~2.49 mm/day, 0.45~0.76, 0.81~0.90 respectively.

Study of the Lower Duration Curve Characteristic by Reservoir and Weir Couple-operating System in Geum River Basin (금강수계 댐과 보의 운영에 의한 하류 유황특성 연구)

  • Ahn, Jung-Min;Cha, Kee-Uk;Ryoo, Kyong-Sik;Lyu, Si-Wan
    • Journal of Korea Water Resources Association
    • /
    • v.44 no.4
    • /
    • pp.285-293
    • /
    • 2011
  • This study presents effects of downstream control point by coupled operation of dams and multi function weirs in the Geum River. Geum river basin that study area did authoritativeness high quality data to acquisition possibility. We applied the flow duration curve, flow regime coefficient, impounded flow index analysis to investigate the quantitative changes in natural flow regimes. In sphere that water supply is possible, this study applied believability that satisfy 95% at estimation year. Impounded flow index was calculated 0.292 by dam coupled operation and 0.297 by dam-weir coupled operation. The results indicate that the storage amount is increased by 29.7% as being added. Duration flow of downstream control point was improved because became coupled operation by regulation of dam and weir in the geum river.

A Study on the Thermo-mechanical Characteristics and Adhesion Reliability of Anisotropic Conductive Films Depend on the Curing Methods of Epoxy Resins (에폭시 레진의 경화방법에 따른 이방성 전도필름의 접합신뢰성 및 열적기계적 특성 변화)

  • Gil, Man-Seok;Seo, Kyoung-Won;Kim, Jae-Han;Lee, Jong-Won;Jang, Eun-Hee;Jeong, Do-Yeon;Kim, Su-Ja;Kim, Jeong-Soo
    • Polymer(Korea)
    • /
    • v.34 no.3
    • /
    • pp.191-197
    • /
    • 2010
  • To improve the curing method of anisotropic conductive film (ACF) at low temperature, it was studied to replace the thermal latent curing agent of imidazole compounds by the curing agent of cationically initiating type. Thermo-mechanical properties such as glass transition temperature, storage modulus, and coefficient of thermal expansion were investigated for the analysis of curing behavior. The reliability of ACF were observed in thermal cycle and high temperature-high humidity test. ACF using cationic initiator showed faster curing, lower CTE, and higher $T_g$ than the case of using imidazole curing agent, which is important for the high temperature stability. Furthermore, ACF using cationic initiator maintained a stable contact resistance in reliability test, although it was cured at low temperature and fast rate. With these results, it was confirmed that the curing method of epoxy had great effect on thermo-mechanical properties and reliability of ACF.

Practical Research for Quantitative Expression of Leakage Through Optical Gas Image (광학가스이미지에서 유출량의 정량표시 실험적 연구)

  • Park, Suri;Han, Sang-wook;Kim, Byung-jick
    • Journal of the Korean Institute of Gas
    • /
    • v.21 no.5
    • /
    • pp.16-26
    • /
    • 2017
  • In chemical industry plants, the raw material, intermediate and final products can leak from unstable joints of flanges and valves as well as cracks of storage tanks. From the safety and economic standpoints, it is very important to understand whether leaks or not and leakage rate. The OGI(optical gas image) technique can tell gas leakages, but cannot give the leakage rate. Some special OGI devices can show the kind of gas in different color concentration in different darkness. Therefore the research on quantification of OGI is necessary. In this research, we have developed the practical method to quantify OGI of methane leakage. To estimate 3-dimensional gas leakages distribution from 2-dimensional OGI, the Monte Carlo Probability technique was applied. First the number of points in the area of width(2.54 cm) and length(2.54 cm) in OGI was counted. Total no of each experiment was compared with the measured flow rate. The correlation average between total points and measured flow rate was found to be 0.980. Reversely we estimated the leakage rate of OGI by use of the correlation table. The results showed good agreement between the estimation value and the measured value.

Determination of Glucose Distribution of Potato Tuber Using Blood Glucose Meter and Its Application to Estimate Processing Quality (혈당측정기를 이용한 감자 괴경의 포도당 분포 분석과 이의 가공적성 평가에의 활용)

  • Kwon, Byoung-Hoon;Kim, Si Un;Lim, Soo Yeon;Namgung, Hyeju;Lee, Hong Jin
    • Horticultural Science & Technology
    • /
    • v.32 no.2
    • /
    • pp.171-177
    • /
    • 2014
  • In an effort to investigate special distribution of glucose content of potato tuber of a cultivar 'Superior' after harvest, a whole tuber was longitudinally cut into halves and cut-surface was divided into 11 regions. Approximate glucose concentration of each section was determined using a commercial blood glucose meter. Higher level of glucose was detected in the outer layers of tissue than inner part of tuber although there were lower coefficients of variation value, 37.4% and 34.1% among individual tubers and among defined sections, respectively. A positive correlation between the whole tuber and individual section was existed in glucose content, where the central pith tissue gave the highest coefficient (r = 0.921) and bud end tissue did the lowest (r = 0.544). Glucose content of the tubers stored for 4 months at $2.0^{\circ}C$ was 5.5 fold higher compared to the tubers kept in ambient temperature. The chip color of the former tubers was much brighter than those of the latter tubers. The result obtained in the present study suggests that the blood glucose meter can be used to a rapid and simple evaluation of glucose content and therein be applied to estimate the processing quality of potato tubers during postharvest handling.