• 제목/요약/키워드: Steel transmission tower

검색결과 54건 처리시간 0.026초

Wind tunnel tests on wind loads acting on steel tubular transmission towers under skewed wind

  • YANG, Fengli;NIU, Huawei
    • Wind and Structures
    • /
    • 제35권2호
    • /
    • pp.93-108
    • /
    • 2022
  • Steel tubular towers are commonly used in UHV and long crossing transmission lines. By considering effects of the model scale, the solidity ratio and the ratio of the mean width to the mean height, wind tunnel tests under different wind speeds on twenty tubular steel tower body models and twenty-six tubular steel cross-arm models were completed. Drag coefficients and shielding factors of the experimental tower body models and cross-arm models in wind directional axis for typical skewed angles were obtained. The influence of the lift forces on the skewed wind load factors of tubular steel tower bodies was evaluated. The skewed wind load factors, the wind load distribution factors in transversal and longitudinal direction were calculated for the tubular tower body models and cross-arm models, respectively. Fitting expressions for the skewed wind load factors of tubular steel bodies and cross-arms were determined through nonlinear fitting analysis. Parameters for skewed wind loads determined by wind tunnel tests were compared with the regulations in applicable standards. Suggestions on the drag coefficients, the skewed wind load factors and the wind load distribution factors were proposed for tubular steel transmission towers.

Development of the Corrosion Deterioration Inspection Tool for Transmission Tower Members

  • Woo, Sangkyun;Chu, Inyeop;Youn, Byongdon;Kim, Kijung
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제2권2호
    • /
    • pp.293-298
    • /
    • 2016
  • Recently, interests for maintenance of transmission tower are increasing to extend life of structures and reduce maintenance cost. However, existing classical diagnosis method of corrosion deteriorated degree on the transmission tower steel members, visual inspection, has a problem that error often due to difference of inspector's individual knowledge and experience. In order to solve the problem, this study carried out to develop the corrosion deterioration inspection tool for transmission tower steel members. This tool is composed of camera equipment and computer-aided diagnosis system. We standardized the photographing method by camera equipment to obtain suitable pictures for image processing. Diagnosis system was designed to evaluate automatically degree of corrosion deterioration for member of transmission tower on the basis of the RGB color image processing techniques. It is anticipated that developed the corrosion deterioration inspection tool will be very helpful in decision of optimal maintenance time for transmission tower corrosion.

긴급복구용 자주조립식 철주 절연암 개발 (Development of Arm Insulator for Self-Build Based Emergency Tower)

  • 민병욱;위화복;박재웅;이철호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.107-108
    • /
    • 2007
  • Overhead transmission lines are completely exposed to the environment. This causes faults in transmission lines due to natural environmental conditions. In some cases, transmission towers are damaged by typhoons and snow, as well as sleet on the transmission lines. It takes a lot of time to repair the damaged towers. For emergency restoration purposes, steel poles are installed to temporarily supply power. Before 2003, emergency restoration steel poles were made of angled steel, which required a large number of beams, bolts, etc. In addition, the foundation of the steel pole and ground wire was constructed using excavation and burial methods, therefore it required a lot of manpower and time to construct temporary transmission lines. In September 2003, typhoon Maemi, whose maximum wind speed was 60m/s, hit Korea. 'Maemi' destroyed transmission lines in the Busan and Geojea area, causing long blackouts. To reduce the recovery time to the damaged transmission lines, self-build based emergency towers were developed. self-build based emergency towers reduced recovery time from 24 hours to 4 hours or less. However, the self-build based emergency tower had no arms, so the temporary transmission lines could only be constructed without curves in line routes. In this paper, solving these self-build based emergency tower limitations, using insulated arms(designed for use with the self-build based emergency tower), shall be explained.

  • PDF

비선형인자를 고려한 345kV 송전철탑의 유한요소해석 (Finite Element Analysis of 345kV Transmission Tower considering Nonlinear Factors)

  • 김종민;장진원;박종섭;강영종
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2008년도 정기 학술대회
    • /
    • pp.337-340
    • /
    • 2008
  • There were two transmission tower collapses due to Typhoon 'Maemi' in 2003. The reason that a collapse was happened was excessive wind load. One was buckled in the leg part and the other was buckled in the middle bracing part. To investigate a steel transmission tower failure mechanism, 2nd order nonlinear analysis should be performed. Considering the effect of initial imperfection and theresidual stress of angle section during nonlinear analysis, this study can estimate the ultimate strength and the ultimate behavior of the transmission tower.

  • PDF

초기결함과 잔류응력을 고려한 345kV 송전철탑의 비선형해석 (Nonlinear Analysis of 345kV Transmission Tower Considering Initial Imperfection and Residual Stress)

  • 장진원;김승준;박종섭;강영종
    • 한국방재학회:학술대회논문집
    • /
    • 한국방재학회 2008년도 정기총회 및 학술발표대회
    • /
    • pp.283-286
    • /
    • 2008
  • There were two transmission tower collapses due to Typhoon 'Maemi' in 2003. The reason that a collapse was happened was excessive wind load. One was buckled in the leg part and the other was buckled in the middle bracing part. To investigate a steel transmission tower failure mechanism, 2nd order nonlinear analysis should be performed. Considering the effect of initial imperfection and theresidual stress of angle section during nonlinear analysis, this study can estimate the ultimate strength and the ultimate behavior of the transmission tower.

  • PDF

절연암 적용 컴팩트 철탑 개발 (Development of Compact Towers with Insulation Arm in Korea)

  • Lee, Won-kyo;Yun, Cheol-Hee
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제4권2호
    • /
    • pp.63-66
    • /
    • 2018
  • Lattice towers and tubular steel poles have been commonly used for electrical power transmission in Korea as well as the other countries. They are durable, structurally stable, simple and can easily be constructed in limited spaces. However, residents are opposed to construct transmission lattice towers in their areas because they are not visually attractive, and electrical field occur at the transmission lines. Underground transmissions have been used instead of the traditional towers to resolve these problems, however they are not cost effective to construct and run. Therefore, we have developed compact towers that are more attractive, well blend into the surrounding environment and much more economical than underground transmissions. This paper shows the design of a compact towers with insulation arm, in order to reduce the height of tower and the separation between phases. The compact tower can be installed in a narrow right-of-way. Insulation arms are easily applied to lattice and steel tubular towers instead of steel arms. Compact towers with insulation arm are also considered as a solution to have public acceptance or to create a familiar atmosphere among towers and people. Compact tower compared with a conventional tower, insulation arms reduces the width and height of the tower by 20% and 15% respectively.

철탑 사각골조의 풍력 계수 산정에 관한 실험적 연구 (An Experimental Study on the Estimate of Wind Force Coefficient of Transmission Tower Rectangular Frame)

  • 신구용;임재섭;황규석;길용식
    • 한국강구조학회 논문집
    • /
    • 제23권1호
    • /
    • pp.73-81
    • /
    • 2011
  • 골조로 구성된 철탑의 풍력계수는 구성부재의 단면형상, 충실율 등에 의해 변하며 풍향각에 의해서도 여러 가지 특성이 나타난다. 본 연구에서는 이러한 철탑골조에 대하여 충실율과 풍향각을 변화시키면서 풍동실험을 수행하여 철탑골조에 작용하는 풍력특성을 평가한다. 실험은 먼저 철탑을 구성하고 있는 부재의 특성을 파악하기 위한 기본형상 부재에 대한 실험을 수행하였다. 그리고 철탑 사각골조는 2D와 3D 형태로 기본형에 철탑부재를 추가하는 방법과, 부재크기를 증가시키는 방법으로 충실율을 변화시킨 모형을 제작하였으며, 2D 형상은 풍향각을 0도에서 90도까지, 3D 형상은 풍향각을 0도에서 45도까지 변화시키면서 풍동실험을 수행하였다. 본 연구의 결과인 철탑 사각골조의 풍력계수 특성은 향후 철탑 풍하중 설계의 기초자료로 사용될 것이다.

가선작업 하중을 고려한 765kV 강관철탑 설계 (765kV Steel Tubular Tower Design On Considering Stringing Load)

  • 정태호;김신철;윤영순;신태우;이안근;김광열
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.935-937
    • /
    • 1998
  • The stringing load was added to tower design that consider the active load in 765kV transmission line construction. The nominal auxiliary members of steell tubular tower arm were altered into stress members by means of three dimensional design analysis method. 765kV transmission line construction also use self-standing tower that does not install temporary wire which support the section tower placed between drum field and engine field when stringing process.

  • PDF

환경조화형 철탑 개발 (Development of Eco-friendly Electric Transmission Towers in KEPCO)

  • Lee, Won-kyo;Mun, Sung-Duk;Shin, Kooyong
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제5권3호
    • /
    • pp.135-140
    • /
    • 2019
  • Lattice towers and tubular steel poles have been commonly used for electrical power transmission in Korea. They are durable, structurally stable, simple and can easily be constructed in limited spaces. However, residents are opposed to construct transmission lattice towers in their areas because they are not visually attractive, and electrical field occur at the transmission lines. Underground transmissions have been used instead of the traditional towers to resolve these problems, however they are not cost effective to construct and run. Therefore, we have developed eco-friendly towers that are more attractive, well blending into the surrounding environment, and much more economical than underground transmissions. There are four categories of the eco-friendly electric transmission towers about design aspects. Firstly, there is decoration type such as tree tower and ensemble tower. Tree tower looks like actual trees with leaves and branches so it blends into surroundings. Ensemble towers were designed after pair of crane birds. Those towers have decoration features and art works. Structural examination and manufacturing this type would be very similar to the conventional transmission towers. Secondly, there is arm design type such as traditional tower. Design features are added to the existing towers. As partial design can be adoptable on these types, it can easily meet height regulations and attach to conventional lattice towers and tubular steel poles. Also, these towers are more economical than others. Third category is multipurpose type such as Sail Tower. These towers have simple pole or tubular structure with features which can be used as information message board, public relations and much more. This type will face greater wind pressure because of the area of the board, also visibility must take into consideration. Lastly, there is moulding type such as arc pylon. It is different shape to the conventional towers - lattice towers and tubular steel poles. Dramatic design changes have been adapted - from a hard and static tower to a soft and curved tower. These towers will well stand out in the field. However, structural examination and manufacturing this type would be difficult and costly. Also certain towers of this type would require scaffolding or false work to construct, which will result in limitations of the construction area. This paper shows KEPCO 154 kV Sail tower in detail. KEPCO 154 kV Sail tower that is included in fabrication of sample tower and tower testing has developed and the results are presented in this paper. We hope that sail tower is also considered as a solution to have public acceptance or to create a familiar atmosphere among towers and people in coastal area.

부재 내력과 접합부 내력을 고려한 송전강관철탑의 극한하중 도출에 관한 연구 (A Study on the Ultimate Load of Electric Transmission Tower Considering Member Strength and Joint Strength)

  • 김우범;전범준;서용표
    • 한국강구조학회 논문집
    • /
    • 제22권5호
    • /
    • pp.435-443
    • /
    • 2010
  • 현행 송전강관철탑의 경우 허용응력 설계개념을 도입한 철탑설계기준을 적용하여 설계, 제작되고 있다. 이 철탑설계기준의 압축재의 설계 강도 결정은 압축재의 허용좌굴응력에 의하여 결정되고 있으나 이는 접합부의 내력을 고려치 않은 값이다. 부재가 압축좌굴내력에 도달하기 전에 접합부의 변형으로 인하여 국부변형에 의한 접합부 파괴가 발생할 수 있다. 따라서 본 연구에서는 접합부의 보강형태별로 접합부내력을 산출하고 이를 데이터베이스화한 후 지난 연구에서 도출한 등가비선형해석기법의 부재내력과의 상호 비교를 통하여 부재파괴와 접합부파괴의 선행 여부를 판별할 수 있는 실용적인 평가 및 설계 기법을 제시하였다.