North Korean Housing Planning Trend through Analysis on North Korean Architectural Media (북한 건축 전문매체 분석을 통한 살림집 계획 동향)

  • Choi, Sang-Hee
    • Land and Housing Review
    • /
    • v.8 no.4
    • /
    • pp.223-232
    • /
    • 2017
  • The purpose of this study is to identify the supply status and planning trend of North Korean housing through analysis on the North Korean architecture specialized media data. The flat composition is changing and the living room is becoming the center of the houses. Also, in the urban areas, the standard apartment type is four apartments in a row and the plan form is getting diversified into circle type, Y type, and irregular type. On the other hand, in the rural areas, two houses in a row and single house are typical and the change in planning scale and space structure are not substantial. Since the 2000s, design changes have been made to emphasize the third dimensional structure of buildings such as the elliptical houses and L-shaped houses. Furthermore, 8~10 households are located on one floor which leads to the tendency of the building enlargement. In terms of house size, a square concept was introduced to replace the initial 2~3 room concept and the basic module of the room planning the 3 room house based on $3m{\times}3m$. However, there seems to be no standard house size, and the house size may differ depending on the social classandregion. In the early 1980s, when there was focus on the apartment complex construction, the high-rise apartment buildings of 30~40 floors was planned. However, during the Pyongyang redevelopment project, apartments of more or less than 10 floors were built and row-houses of more or less than 4 floors were built. In terms of the complex scale, a lot of small complexes of around 300 households are emerging after 2010. The construction projects are mainly limited to specific regions such as Pyongyang and Samjiyeon, and also limited to specific classes such as the workers and soldiers initially and the scientists lately. In addition, living boundary composition and ancillary facilities for sufficient green area ratio securement and the people of North Korea are maintained consistently. In recent years, the specialized floor planning such as solar house and the house for the disabled people, framework houses for redevelopment business, and multi-storied house construction technology are also emerging.

A Basic Study on Feasibility Analysis for Solar Energy Facility using Standard Broiler House Roof (표준육계사의 지붕을 활용한 태양에너지 설비 타당성 분석에 관한 기초 연구)

  • Kim, Jin-Hyun;Jung, Sung-Jin;Kim, Tae-Wook;Choi, Jun-Hak;Ha, Yu-Shin
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.4
    • /
    • pp.57-65
    • /
    • 2014
  • In order to reduce greenhouse gas emissions in recent agricultural energy and increase the energy self-sufficiency rate of each farmer, it is extremely important to expand the supply of solar energy using unused space of agricultural facilities, roof. This study surveyed and analyzed the environmental and administrative factors such as problems according to the structure, azimuth and latitude of broiler houses and stability of standard broiler houses required to use broiler house roof based on the poultry houses in Sangju-si. The results can be summarized as follows: 55.6% of the solar energy facilities of according to the classification of arable lands of broiler houses were available, and 31.7% of them were available by classifying according to the azimuth. However, 20.6% of them were available in the survey considering all the arable land and azimuth. In the roof inclination of the broiler houses, from 20 to $25^{\circ}$ was the most common, 30 broiler houses. The broiler houses with the roof inclination more than $20^{\circ}$ accounted for 63% of the total. It was considered that the inclination was generally proper. In the structural safety, only 3 broiler houses that were constructed as a standard broiler house were available. In practice, all but one broiler house was inappropriate to expand the solar energy project using roof. The solar thermal facility weighed $63.6kg/m^2$ in total: the frame and solar thermal collector weighed $27.8kg/m^2$ and $35.8kg/m^2$, respectively. The standard broiler house required to be internally reinforced. This study suggested a plan for internal reinforcement and a feasible plan because there were problems with structural safety when installing solar thermal and photovoltaic systems.

A Case Study on the District Standard Planning Applied to Single-Detached House Area of Eomsa District Dooma-Myun Nonsan in Chungnam Province (충남 논산 두마면 엄사지구 단독주택지에 적용된 지구단위계획실태조사연구)

  • Kim, Joon-Yeoul;Choi, Hyo-Seung
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.3 no.3
    • /
    • pp.47-55
    • /
    • 2001
  • For several years by discussion and research, the designing plan and detail plans of year 2000 has been unified. By this result the District Standard Planning as well as the following existing town to control all sorts of living surrounding problems and to make a delightful arranged town are the purpose, which is carrying out all over the country. It is true that the expectation was high to the District Standard Planning. Because of this plan it could use and control the District special quality. Such as, it could rise the ability of beautiful sight and make a advisable town. But in this study the first preceding subject is a problem by the constructing work that the restriction and the standard application has been strong. So the District Standard Planning had many problems. And also by the problems here, as a immoderate volition and stiffen about the operation, the system and equipment lack about the environment improving work, problems with areas by the exciting plannings, the attitude of the executive agency that can't accept the inhabitants will. From these backgrounds we thought the research has not to be standardize in only newtown concept, but has to breath with the exciting towns and the rural areas that the District Planning has been applied. And to revive the special quality of the area and local government by a positive and logical research. Consequently in this study, we researched about the problems of architectures that had issues with the District Standard Planning of architectural part of operation guide which has been assisted form Single-Detached House in Eomsa District Dooma-Myun Nonsan which is located in Chungnam province.

  • PDF

A Multiplex Housing Energy Conservation Strategy through Combining Insulation Standard Based Green Roof Systems and Passive Design Elements

  • Son, Hyeongmin;Park, Dong Yoon;Chang, Seongju
    • KIEAE Journal
    • /
    • v.14 no.1
    • /
    • pp.31-38
    • /
    • 2014
  • Recently, the coverage of urban forests has been rapidly decreasing as the cities are created and expanding. Consequently, there arise urban problems such as heat island effect, urban flooding, urban desertification and so on. In this context, green roof systems is considered to be an efficient alternative to deal with these problems. However, it is difficult to apply green roof to new buildings since the majority of the buildings in cities are already constructed and the demand for new building constructions is not high enough. Therefore, it should be considered to apply green roof system to existing buildings for resolving various problems. This study evaluates heating and cooling energy consumption based on the combination of passive design factors such as wall, roof, window insulation in addition to a green roof system applied to an existing house by using an energy simulation program. Total 8 potential improvement cases are developed. Each case is applied to the same house with different insulation standard for simulations. Through the analysis of the simulated cases with the chosen test house, it is confirmed that heating energy consumption decreases as improvement cases are applied, but cooling energy consumption is relatively not much affected by each improvement case. In addition, when each improvement case is applied to already highly insulated house, the effect of thermal energy improvement decreases while the same improvement that is applied to the case with low insulated house tends to yield higher improvement rate.

The Actual State and Evaluation of Artificial Lighting on Coffee Houses Using Study Place around University (학습공간으로 이용되는 대학주변 커피전문점의 조명 실태 및 평가)

  • Choe, Sol-ji;Choi, Yoon-Jung
    • KIEAE Journal
    • /
    • v.11 no.6
    • /
    • pp.53-62
    • /
    • 2011
  • This study aimed at suggesting improvement of lighting environment of the coffee house using study place. To this end, a series of field investigation was conducted in four possible target coffee houses around university. The field measurement included measurement of general illuminance and tabletop illuminance, observing illumination condition, and status of artificial lighting. Also, on-site questionnaire survey was administrated to 80 users of field measurement targets about using characteristics of coffee house and user's subjective response on light environment. The results are summarized as follows: (1) According to questionnaire survey, most of users checked 'learning (study and reading)' in 'purpose of coffee house using', and 'slightly dark' was checked most in each subjective response (brightness on general space and on tabletop at daytime/night); (2) as results of measurements on general illuminance and on tabletop illuminance during daytime, only one coffee house was suitable for standard; (3) as results of measurements on illuminance during night, all target coffee houses were not met the standard; (4) as results of uniformity ratios, almost uniformities of general illuminance were not met the standard except one case. The common problems of lighting environment of coffee house were analyzed as lack of daylight illumination e.g. having low amount of sunshine from skylight, un-uniformity of insolation by floor plan and absence of window blind, and un-uniformity of artificial luminous intensity e.g. lack of the number or brightness of artificial lighting, using the indirect lighting, using only local lighting, and non-uniform arrangement of artificial lighting.

A Historical Study on Railroad Station Buildig Design in Korea (한국철도시설물(韓國鐵道施設物) 디자인의 발전과정(發展過程)에 관(關)한 연구(硏究) -건축도면(建築圖面) 및 현존역사(現存驛舍)에 나타난 수법(手法)을 중심으로-)

  • Yoon, In-Suk
    • Journal of architectural history
    • /
    • v.7 no.3 s.16
    • /
    • pp.67-86
    • /
    • 1998
  • In this thesis, the Development of Station Buildigs Design during last a hundred years in Korea is analyzed. From the early time to today, several posts of Office of Korean National Railroads have controlled the Station Buildings Design by Standard Drawings. Sometimes, private architects joined in designing the Stations, that have the value as historic architecture. Under the Japanese imperialistic rule, Japanese Officer designed all of the stations ; that can be classified 1) wooden compromise style, 2) renaissance style, 3) northern European house style, 4) general station by standard drawing, 5) Korean house style. 6) modernism style. Especially, Korean house style was not planned to commemorate the old Korean Architecture, but to beguile the Japanese tourists' monotony of the journey in Korea. After the Independence, the Station Buildings are grouped into 1) international style, 2) modernism style with traditional details, 3) Station Complex Buildings. In the future, design of the Railroad Station Building needs to be diversified to satisfy tourists' emotion.

  • PDF

Evaluation Standard of Cost-Effectiveness Analysis for Renew of Architectural Equipment in Public Building (공공건물 건축설비 갱신 계획시 비용-효율분석 평가기준에 관한 연구)

  • Jung, Soon-Sung
    • Journal of Power System Engineering
    • /
    • v.17 no.4
    • /
    • pp.131-138
    • /
    • 2013
  • The purpose of this study is to suggest the evaluation standard of cost-effectiveness analysis for renew of architectural equipment in public building. Evaluation items of cost-effectiveness analysis for renew of architectural equipment in public building were used life cycle cost, energy consumption(ton of oil equivalent), green house gas emissions(ton of carbon dioxide) and maximum power demand. Life cycle cost is the process of making an economic assessment of an item, area, system, or facility by considering all significant costs of ownership over an economic life, expressed in terms of equivalent costs. The essence of life cycle costing is the analysis of equivalent costs of various alternative proposals. The social concern with green house gas and maximum power demand of architectural equipment field has been growing for the last several years.

Development of Plane Spatial Structure of Rural Housing for Environmental and Traditional Integrity (농촌주택의 전통환경보전형 평면공간구조 개발)

  • 박장혁;이신호
    • Proceedings of the Korean Society of Rural Planning Conference
    • /
    • 1998.03a
    • /
    • pp.35-40
    • /
    • 1998
  • The characteristics of traditional house and standard house of rural region were analyzed through survey and literature. The plane spatial structure of rural housing was presented unde]environmental integrity and traditional preservation.

  • PDF

Experimental and computational study of acoustic performance of the aircraft hush house (항공기 소음 저감시설의 음향 성능 관련 실험 및 예측에 관한 연구)

  • Jung, Hwan-Ik;Kim, Kwan-Ju;Park, Jin-Kyu;Kim, Sang-Hun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.754-757
    • /
    • 2005
  • Aircraft noise is the serious problem for inhabitants near an air force base. Noise by ground test of aircraft, however, can be minimized through test room construction. In this study, environmental effects of the noise by aircraft ground test were investigated by experiments under the standard act and by performance, prediction of the Hush house, constructed for the noise reduction.

  • PDF

A Study on the Structural Safety Analysis for Vinyl House at Wind Load (비닐하우스의 풍하중 구조안전성 검토에 관한 연구)

  • Paik, Shinwon
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.5
    • /
    • pp.72-77
    • /
    • 2019
  • Vinyl house consists of main rafter, lateral member, clamps and polyethylene film. Many vinyl houses are used to grow fruits, flowers and vegetables in the countryside. Due to climate change, vinyl houses are often destroyed by strong winds or typhoons in summer. Many farmers suffer great economic damage from the collapse of vinyl houses. So it is very important to build a safe vinyl house and find a method to withstand this heavy wind load. In this study, a structural analysis was performed on four types of vinyl houses(10-single-4, 10-single-6, 10-single-7, 10-single-10). In addition, axial force and flexural moment are obtained from the structural analysis of four types of vinyl house. For these four types of vinyl house, structural safety was reviewed by obtaining the combined stress ratio by the strength design method. This structural review showed that the specifications for the vinyl house proposed in the design are not safe. Especially, the result of structural analysis for four types of vinyl house showed that the vinyl house structure constructed as a standard was a very dangerous structure. Therefore, it is necessary to devise diverse methods in order to make vinyl houses structurally safe for heavy wind load in the future. Also a variety of manual development is needed to prevent the collapse of vinyl houses at heavy wind load.