DOI QR코드

DOI QR Code

Evaluation Standard of Cost-Effectiveness Analysis for Renew of Architectural Equipment in Public Building

공공건물 건축설비 갱신 계획시 비용-효율분석 평가기준에 관한 연구

  • Jung, Soon-Sung (Department of Architectural Engineering, TongMyong University)
  • 정순성 (동명대학교 건축공학과)
  • Received : 2013.05.07
  • Accepted : 2013.05.27
  • Published : 2013.08.31

Abstract

The purpose of this study is to suggest the evaluation standard of cost-effectiveness analysis for renew of architectural equipment in public building. Evaluation items of cost-effectiveness analysis for renew of architectural equipment in public building were used life cycle cost, energy consumption(ton of oil equivalent), green house gas emissions(ton of carbon dioxide) and maximum power demand. Life cycle cost is the process of making an economic assessment of an item, area, system, or facility by considering all significant costs of ownership over an economic life, expressed in terms of equivalent costs. The essence of life cycle costing is the analysis of equivalent costs of various alternative proposals. The social concern with green house gas and maximum power demand of architectural equipment field has been growing for the last several years.

Keywords

References

  1. Y. H. Kim, S. S. Kim, S. I. Kim and S. G. Kim, 1994, "Engineering Economics", Cheongmungak Publishing Co., Seoul, p. 345.
  2. M. Y. Park and M. J. Kim, 1995, "A Study on the Economics of HVAC equipment by Life Cycle Costing in Deluxe Hotel", Journal of the Architectural Institute of Korea, Vol. 11, No. 9, pp. 155-164.
  3. I. G. Lee, H. W. Kang, Y. M. Won and Y. S. Kim, 2011, "Economics Evaluation for Heating and Cooling System by Using Gas Energy and Geothermal Energy Base on LCC Analysis", Journal of the Architectural Institute of Korea, Vol. 27, No. 10, pp. 161-168.
  4. J. K. Kim, K. S. Chung, Y. I. Kim, 2012, "Comparison Study of Air-conditioning Systems using LCC Analysis", Transactions of the Korea Society of Geothermal Energy Engineers, Vol. 8, No. 2, pp. 12-18.
  5. K. H. Lee, J. H. Park, J. W. Jin, K. R. Kwon and K. H. Choi, 2012, "Economic analysis of jeju offshore pilot run wind farm by sensitivity analysis", Journal of the Korea Society for Power System Engineering, Vol. 16, No. 5, pp.13-19. https://doi.org/10.9726/kspse.2012.16.5.013
  6. S. U. Kim and S. H. Kim, 2011, "A Study on the Energy Consumption Analysis and Improvement of Busan City Public Building", Journal of the Korean Solar Energy Society, Vol. 31, No. 1, pp. 115-120. https://doi.org/10.7836/kses.2011.31.1.115
  7. J. S. Jang and S. W. Ji, 2011, "Evaluation of Energy Transfer Efficiency of Pneumatic Driving Apparatus", Journal of the Korea Society for Power System Engineering, Vol. 15, No. 6, pp.95-100. https://doi.org/10.9726/kspse.2011.15.6.095
  8. G. J. Jung, 2008, "Estimation on the Carbon Tax Influence of the Construction Cost and the Running Energy Cost in the Apartment Building", Journal of the Regional Association of Architectural Institute of Korea, Vol. 10, No. 2, pp. 231-238.
  9. S. S. Jung, 1999, A Study on the Development of Life Cycle Costing Influence Diagram for Decision Analysis of HVAC system, Dong-A University, Busan, Korea.