Abstract

In order to reduce greenhouse gas emissions in recent agricultural energy and increase the energy self-sufficiency rate of each farmer, it is extremely important to expand the supply of solar energy using unused space of agricultural facilities, roof. This study surveyed and analyzed the environmental and administrative factors such as problems according to the structure, azimuth and latitude of broiler houses and stability of standard broiler houses required to use broiler house roof based on the poultry houses in Sangju-si. The results can be summarized as follows: 55.6% of the solar energy facilities of according to the classification of arable lands of broiler houses were available, and 31.7% of them were available by classifying according to the azimuth. However, 20.6% of them were available in the survey considering all the arable land and azimuth. In the roof inclination of the broiler houses, from 20 to $25^{\circ}$ was the most common, 30 broiler houses. The broiler houses with the roof inclination more than $20^{\circ}$ accounted for 63% of the total. It was considered that the inclination was generally proper. In the structural safety, only 3 broiler houses that were constructed as a standard broiler house were available. In practice, all but one broiler house was inappropriate to expand the solar energy project using roof. The solar thermal facility weighed $63.6kg/m^2$ in total: the frame and solar thermal collector weighed $27.8kg/m^2$ and $35.8kg/m^2$, respectively. The standard broiler house required to be internally reinforced. This study suggested a plan for internal reinforcement and a feasible plan because there were problems with structural safety when installing solar thermal and photovoltaic systems.

Keywords

References

  1. MOTIE, The Second Energy Master Plan, Ministry of Trade Industry & Energy, p. 43, 2014
  2. MKE, New and Renewable Energy Development-Use and Spread Promotion Statute Book, Ministry of Knowledge Economy, p. 78, 2012
  3. MOLEG, Agricultural Land Law-Article 29 Acting in Agricultural Promotion Areas Can. Enforcement Decree of the Agricultural Land Law, Ministry of Government Legislation, 2014
  4. MOLEG, Green Building Construction Support Act-Enforcement Decree of Green Building Construction Support Act, Ministry of Government Legislation, 2013
  5. KAMICO, Agricultural Machinery Yearbook Republic of Korea, Korea Agricultural Machinery Industry Cooperative & The Korean Society for Agricultural Machinery, p. 115, 2013
  6. MOLEG, Law on Planning and Utilization of the National Territory -Article 71 Enforcement Decree of Act on Planning and Utilization of the National Territory, Ministry of Government Legislation, pp. 34-35, 2014