• 제목/요약/키워드: Stage efficiency

Search Result 2,432, Processing Time 0.031 seconds

Ku-Band Three-Stack CMOS Power Amplifier to Enhance Output Power and Efficiency (출력 전력 및 효율 개선을 위한 3-스택 구조의 Ku 대역 CMOS 전력 증폭기)

  • Yang, Junhyuk;Jang, Seonhye;Jung, Hayeon;Joo, Taehwan;Park, Changkun
    • Journal of IKEEE
    • /
    • v.25 no.1
    • /
    • pp.133-138
    • /
    • 2021
  • We propose a Ku-band three-stack CMOS power amplifier to enhance the output power and efficiency. To minimize the dc power consumption, the driver stage is designed using common-source structure. To obtain high output power and utilize a voltage combining method, the power stage is designed using stack structure. To verify the proposed power amplifier structure, we design a Ku-band power amplifier using 65-nm RFCMOS process which provide nine metal layers. The P1dB, power-added efficiency, and gain are higher than 20 dBm, 23 dB, and 25%, respectively, while the operating frequency is 14 GHz-16 GHz.

Improvement of Rapid Sand Filtration to Two Stage Dual Media Filtration System in Water Treatment Plant (정수처리장 사여과지의 이단이중여과재 시스템으로의 개량)

  • Woo, Dal-Sik;Kim, Jooneon;Hwang, Byung-Gi;Chae, Su-Kweon;Jo, Kwanhyung
    • Journal of Environmental Science International
    • /
    • v.23 no.4
    • /
    • pp.737-742
    • /
    • 2014
  • This study aimed for evaluating the applicability of the two stage dual media filtration system in field water treatment plant. The field plant of two stage and dual media filtration system was operated for 2 months. Average iron concentrations of the settled water, existing filtered water and second stage filtered water was 0.041 mg/L, 0.007 mg/L and 0.005 mg/L, respectively. Removal efficiency of iron concentration in the second stage is appropriately 35% more than in existing filtered water. Also removal efficiency of residual chlorine in the dual media filtration system is relatively 42.3% more than in existing filtered water due to adsorption of activated carbon, but the removal of ammonia nitrogen by adsorption is insufficient. Average concentrations of THM and chloroform in the settled water are 0.033 mg/L, 0.026 mg/L, respectively and in existing filtered water are 0.023 mg/L and 0.023 mg/L. Average concentrations of THM and chloroform in the dual media filtration system are 0.008 mg/L and 0.013 mg/L. Therefore removal efficiency of THM concentration in second stage is more than 66.4% in existing filtrated water. Also removal efficiency of chloroform in the dual media filtration system is more than 50.0% in existing filtered water because of the adsorption of activated carbon. In this case backwashing period in dual stage system is 4~5 days, but in existing filtration system is 1~2 days.

A two-stage Kalman filter for the identification of structural parameters with unknown loads

  • He, Jia;Zhang, Xiaoxiong;Feng, Zhouquan;Chen, Zhengqing;Cao, Zhang
    • Smart Structures and Systems
    • /
    • v.26 no.6
    • /
    • pp.693-701
    • /
    • 2020
  • The conventional Kalman Filter (KF) provides a promising way for structural state estimation. However, the physical parameters of structural systems or models should be available for the estimation. Moreover, it is not applicable when the loadings applied to the structures are unknown. To circumvent the aforementioned limitations, a two-stage KF with unknown input approach is proposed for the simultaneous identification of structural parameters and unknown loadings. In stage 1, a modified observation equation is employed. The structural state vector is estimated by KF on the basis of structural parameters identified at the previous time-step. Then, the unknown input is identified by Least Squares Estimation (LSE). In stage 2, based on the concept of sensitivity matrix, the structural parameters are updated at the current time-step by using the estimated structural states obtained from stage 1. The effectiveness of the proposed approach is numerically validated via a five-story shearing model under random and earthquake excitations. Shaking table tests on a five-story structure are also employed to demonstrate the performance of the proposed approach. It is demonstrated from numerical and experimental results that the proposed approach can be used for the identification of parameters of structure and the external force applied to it with acceptable accuracy.

Design of an electrostatic 2-axis MEMS stage with large area platform (대면적 플랫폼을 갖는 정전형 2 축 MEMS 스테이지의 설계)

  • 정일진;전종업;백경록;박규열
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.373-378
    • /
    • 2004
  • Recently the electrostatic 2-axis MEMS stages have been fabricated for the purpose of an application to PSD (Probebased Storage Device). However, most of them have low area efficiency, which is undesirable as data storage devices, since all of the components (springs, comb electrodes, anchors, platform, etc.) are placed in-plane. In this paper, we present a novel structure of electrostatic 2-axis MEMS stage that is characterized by having large area platform. For large area efficiency, the actuator part consisting of mainly comb electrodes and springs is placed right below the platform. In this article, the structures and operational principle of the MEMS stages are described, followed by design procedure, structural and modal analysis using FEM(Finite Element Method). The area efficiency of the MEMS stage was designed to be about 55%, that is very large compared with conventional ones having a few percentage.

  • PDF

Asymmetric Saturated 3-Stage Doherty Power Amplifier Using Envelope Tracking Technique for Improved Efficiency (효율 향상을 위해 포락선 추적 기술을 이용한 비대칭 포화 3-Stage 도허터 전력 증폭기)

  • Kim, Il-Du;Jee, Seung-Hoon;Moon, Jung-Hwan;Son, Jung-Hwan;Kim, Jung-Joon;Kim, Bum-Man
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.8
    • /
    • pp.813-822
    • /
    • 2009
  • We have investigated operation of a 1:2:2 asymmetric 3-stage Doherty PA(Power Amplifier) and implemented using the Freescale's 4 W, 10 W PEP LDMOSFETS at 1 GHz. By employing the three peak efficiency characteristics, compared to the two peak N-way Doherty PA, the asymmetric 3-stage Doherty can overcome the serious efficiency degradation along the backed-off output power region and maximize the average efficiency for the modulation signal. To maximize the efficiency characteristic, the inverse class F PA has been designed as carrier and peaking amplifiers. Furthermore, to extract the proper load modulation operation, the adaptive gate bias control signal has been applied to the two peaking PAs based on the envelope tracking technique. For the 802.16e Mobile WiMAX(World Interoperability for Microwave Access) signal with 8.5 dB PAPR(Peak to Average Power Ratio), the proposed Doherty PA has shown 55.46 % of high efficiency at an average output power of 36.85 dBm while maintaining the -37.23 dB of excellent RCE(Relative Constellation Error) characteristic. This is the first time demonstration of applying the saturated PA and adaptive gate bias control technique to the asymmetric 3-stage Doherty PA for the highly efficient transmitter of the base-station application.

An Analysis of Quality Efficiency of Loan Consultants in a Bank using Shannon's Entropy and PCA-DEA Model (Entropy와 PCA-DEA 모형을 이용한 은행 대출상담사의 서비스 품질 효율성 분석)

  • Choi, Jang Ki;Kim, Kyeongtaek;Suh, Jae Joon
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.40 no.3
    • /
    • pp.7-17
    • /
    • 2017
  • Loan consultants assist clients with loan application processing and loan decisions. Their duties may include contacting people to ask if they want a loan, meeting with loan applicants and explaining different loan options. We studied the efficiency of service quality of loan consultants contracted to a bank in Korea. They do not work as a team, but do work independently. Since he/she is not an employee of the bank, the consultant is paid solely in proportion to how much he/she sell loans. In this study, a consultant is considered as a decision making unit (DMU) in the DEA (Data Envelopment Analysis) model. We use a principal component analysis-data envelopment analysis (PCA-DEA) model integrated with Shannon's Entropy to evaluate quality efficiency of the consultants. We adopt a three-stage process to calculate the efficiency of service quality of the consultants. In the first stage, we use PCA to obtain 6 synthetic indicators, including 4 input indicators and 2 output indicators, from survey results in which questionnaire items are constructed on the basis of SERVQUAL model. In the second stage, 3 DEA models allowing negative values are used to calculate the relative efficiency of each DMU. In the third stage, the weight of each result is calculated on the basis of Shannon's Entropy theory, and then we generate a comprehensive efficiency score using it. An example illustrates the proposed process of evaluating the relative quality efficiency of the loan consultants and how to use the efficiency to improve the service quality of the consultants.

Effects of the Block Distance of Collecting Plate and Particle Size on the particle Deposition Efficiency in the Two-Stage Electrostatic Precipitator (2단식 전기집진기의 집진판 블록간격 및 입자크기가 입자의 부착효율에 미치는 영향)

  • 박청연
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.2
    • /
    • pp.165-178
    • /
    • 2000
  • In this study the effects of block distance have been investigated on the particle deposition efficiency in the collecting cell of two-stage electrostatic precipitator by numerical analysis. Particle trajectories have been changed by the electrostatic and inertial force of particle with the inlet velocity electrostatic number and particle diameter. The total deposition efficiency has a minimum value by the interaction between the effect of particle inertial force and electrostatic force in the collecting cell. The increase of block distance makes the total deposition efficiency decrease under the range of the particle size which has the minimum deposition efficiency. However beyond the range of particle size which has minimum deposition efficiency total deposition efficiency has no trend with the variation of block distance.

  • PDF

Efficiency of Production of Cloned Embryos by Nuclear Transplantation with Nuclear Donor Embryos of Different Cell-stages in Rabbits (토끼에서 공핵수정란의 발달단계에 따른 복제수정란의 생산 효율)

  • 이효종;윤희준;강태영;최상용;조성근;박충생
    • Journal of Veterinary Clinics
    • /
    • v.13 no.2
    • /
    • pp.149-152
    • /
    • 1996
  • This study was carried out to evaluate the efficiency of production of cloned embryos by nuclear translatation (NT) when using 4-cell to compact morula stage embryos as nuclear donor. In micromanitulation and electrofusion of blastomeres from 4-cell to morula stage embryos, the successful injection rate was higher with late stage blastomeres, on the contrary the fusion rate was lower. The in vitro developmental rate of NT embryos was not significantly different between cell-stages of donor blastomeres. Although the overall rate of production of cloned embryos with 4-cell. 8-cell, early and late morula stage embryos was 14.0, 18.0, 15.3 and 14.1%, respectively, the mean number of blastocysts produced with a donor embryo was the most (4.51) with the compact morulae. Therefore, it can be suggested that the embryos at thelate stage is more beneficial for the mulciple production of cloned embryos, If the late stage blastomeres have maintained their totipotency to produce intact offspring.

  • PDF

Analyzing the Influence Factors on Efficiency of Public Libraries in Metropolitan Cities by DEA and Tobit Model (DEA와 Tobit 모형을 이용한 대도시 공공도서관의 효율성 영향요인 분석)

  • Lee, Sang-Su;Han, Ha-Neul
    • Journal of Information Management
    • /
    • v.41 no.2
    • /
    • pp.111-131
    • /
    • 2010
  • This paper examines the levels and influence factors on efficiency of public libraries in metropolitan cities. For this purpose, In the first stage, the efficiency score analysis of 129 sample public libraries has been undertaken. In the second stage, the efficiency scores obtained from the first stage are regressed on environmental factors. The result of this study shows that : (1) main source of technical inefficiency is pure technical inefficiency rather than scale inefficiency; (2) it is positive effect environmental factors on the efficiency that the population, the dummy variable of capital area.

A High Efficiency Two-stage Inverter for Photovoltaic Grid-connected Generation Systems

  • Liu, Jiang;Cheng, Shanmei;Shen, Anwen
    • Journal of Power Electronics
    • /
    • v.17 no.1
    • /
    • pp.200-211
    • /
    • 2017
  • Conventional boost-full-bridge and boost-hybrid-bridge two-stage inverters are widely applied in order to adapt to the wide dc input voltage range of photovoltaic arrays. However, the efficiency of the conventional topology is not fully optimized because additional switching losses are generated in the voltage conversion so that the input voltage rises and then falls. Moreover, the electrolytic capacitors in a dc-link lead to a larger volume combined with increases in both weight and cost. This paper proposes a higher efficiency inverter with time-sharing synchronous modulation. The energy transmission paths, wheeling branches and switching losses for the high-frequency switches are optimized so that the overall efficiency is greatly improved. In this paper, a contrastive analysis of the component losses for the conventional and proposed inverter topologies is carried out in MATLAB. Finally, the high-efficiency under different switching frequencies and different input voltages is verified by a 3 kW prototype.