• 제목/요약/키워드: Solar Module Temperature

검색결과 233건 처리시간 0.022초

결정질과 비정질 PV모듈의 자연광 스펙트럼에 따른 Isc의 변화 (Transition of Isc according to Natural Solar Spectrum on c-Si and a-Si PV Module)

  • 공지현;지양근;강기환;유권종;안형근;한득영
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.86-91
    • /
    • 2009
  • In this paper, we analyze the Transition of Isc by natural solar spectrum of c-Si and a-Si PV module. Commonly, performance of photovoltaic (PV) module is estimated under the standard test condition (STC). That is, solar irradiance $1kW/m^2$, solar spectrum distribution: AM1 5G, module temperature $25^{\circ}C$ This means it rarely meets actual outdoor conditions. The solar spectrum always changes. So it is rare to fit the standard solar spectrum AM1 5G defined in ASTM G173-03 or IEC 60904-3. Thus spectral response of PV module is different depending on the material. so we estimated the variation of Isc at every minutes by comparing c-Si PV module with a-si PV module for outdoor conditions.

  • PDF

사각튜브부착형 흡열판을 적용한 Unglazed PVT 복합모듈의 열적 전기적 성능분석 (The Experimental Performance of Rectangular Tube Absorber PV/Thermal Combined Collector Module)

  • 정선옥;천진아;김진희;김준태;조인수;남승백
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 추계학술발표대회 논문집
    • /
    • pp.87-92
    • /
    • 2011
  • The heat from PV modules should be removed for better electrical performance, and can be converted into useful thermal energy. A photovoltaic-thermal(PVT)module is a combination of PV module with a solar thermal collector which forms one device that converts solar radiation into electricity and heat simultaneously. The performance of the PV/Thermal combined collector module is directly influenced by solar radiation that also has an effect on PV module temperature. It is also has believe that the energy performance of PV/T collector is related to absorber design as well as PV module temperature. The existing study has been paid to the PV/Thermal combined collector module with circle tube absorbers. The aim of this study is to analyze the experimental performance of the PV/Thermal combined collector rectangular tube absorbers according to solar radiation. The experimental result show that the average thermal and electrical efficiencies of the PVT collector were 43% and14.81% respectively. Solar radiation is one of the most influential factors to determine the energy performance of PVT collector, but from a certain level of solar radiation the PVT collector receives on, its efficiencies began to decrease.

  • PDF

태양전지 모듈의 구성 요소가 PID 발생에 미치는 영향 (The Effect of PID Generation by Components of the PV Module)

  • 김한별;정태희;강기환;장효식
    • 한국전기전자재료학회논문지
    • /
    • 제26권10호
    • /
    • pp.760-765
    • /
    • 2013
  • PID (potential induced degradation) of PV module is the degradation of module due to the high potential difference between the front surface of solar cells and ground when PV modules operate under high humidity and temperature conditions. PID is generally derived from the positive sodium ions in front glass that are accumulated on P-type solar cells. Therefore, some papers for the electrical characteristic of only front components as glass, EVA sheet, solar cell under PID generation condition were revealed. In this paper, we analyzed the different outputs of module with PID by considering the all parts of module including the back side elements such as glass, back sheet. Mini modules with one solar cell were fabricated with the various parts on front and back sided of module. To generate PID of module in a short time, the all modules were applied.1,000 V in $85^{\circ}C$, 85% RH. The outputs, dark IV curves and EL images of all modules before and after experiments were also measured to confirm the main components of module for PID generation. From the measured results, the outputs of all modules with front glass were remarkably reduced and the performances of modules with back and front glass were greatly deteriorated. We suggest that the obtained data could be used to reduce the PID phenomenon of diverse modules such as conventional module and BIPV (building integrated photovoltaic) module.

5kW급 투광형 박막 BIPV시스템의 실증연구 (Case Study on 5kWp Transparent Thin-Film BIPV System)

  • 안영섭;김성태;이성진;송종화;황상근;윤종호
    • 한국태양에너지학회 논문집
    • /
    • 제30권4호
    • /
    • pp.29-35
    • /
    • 2010
  • This study has been carried out empirical research on Transparent Thin-film BIPV modules, BIPV modules installed on the exterior of the building are applied a laminated module 1kWp, double-glazing module 3kWp and triple-glazing module 1kWp. Applied to the total capacity of BIPV modules are 5kWp. In this study, design and construction process of BIPV systems is presented. In addition, through monitoring of the BIPV system, the temperature and the power characteristics of each module were analyzed. During the measurement period, the module temperature measurement results, the maximum surface temperature of $51.5^{\circ}C$ triple-glazing BIPV module showed the highest, followed by double-glazing BIPV module $49.1^{\circ}C$, $44.7^{\circ}C$ laminated modules, respectively. Power output results, the daily average double-layer modules showed 4.10kWh/day, triple-glazing module 1.57kWh, respectively 1.81kWh laminated modules. In particular, the power efficiency of triple-glazing BIPV module was lower than the power efficiency of the laminated BIPV module. This phenomenon is considered to be affected by the module temperature. In the future, BIPV modules in this study the relationship between module temperature and power characteristics plans to identify.

단일 모듈 반사경을 이용한 태양열 집열 시스템의 설계, 제작 및 온도측정 시험연구 (Design, Fabrication and temperature measuring experiments of solar collecting system using a single module reflectors)

  • 양병수;양우;서태일;손창우
    • Design & Manufacturing
    • /
    • 제13권1호
    • /
    • pp.19-24
    • /
    • 2019
  • Currently, the world is paying keen attention to the production of renewable energy along with environmental issues, and the share of renewable energy in the world is rising above that of nuclear power. Especially when Korea, which is heavily dependent on foreign countries, needs to reconsider its national competitiveness due to the recent high oil prices, the government's energy policy is to develop and use renewable energy that replaces fossil fuels. In particular, solar energy, the most actively studied and commercialized field of renewable energy, is the main research for solar energy and is commercialized and used. However, the efficiency of solar energy has already reached saturation. Studies are also focusing on increasing the reflectivity of solar energy to increase efficiency. Therefore, this paper proposes a solar collection system that can utilize solar energy rather than solar energy. The proposed solar heat collection system uses solar tracking systems to effectively collect solar energy, particularly those that can be easily produced using single-modular reflectors and have price competitiveness. In addition, temperature measurement experiments with temperature measuring sensors were conducted to ensure reliability in order to verify the results interpreted.

Solar Simulator의 시험조건에 따른 태양전지모듈의 전기적 특성 분석 (Electrical Properties of Photovoltaic Modules with test condition of Solar Simulator)

  • 강기환;박지홍;유권종;박이준;안형근;한득영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1775-1777
    • /
    • 2005
  • In this paper, maximum output of three different temperature conditions of the photovoltaic modules have been tested and compared to obtain the optimum conditions for the maximum power operation. Temperatures of the cell and module have been set to $20^{\circ}C$, $25^{\circ}C$ and $30^{circ}C$ under the constant light intensity of 1kW/$m^2$. 125${\times}$125mm 36 single crystal solar cells having 80 [W] each have been serially connected in the module. From the results, maximum output deviation of 4.67% has been obtained under the ceil temperature of $20^{\circ}C$ and module temperature of $30^{\circ}C$ while minimum deviation of 0.41${\sim}$0.92% has been measured under the same temperatures of cell and module. Therefore it has been found that the temperature of both cell and module should be fixed to $25^{\circ}C$ to obtain stable data unless the temperature coefficient should be compensated for the testing sample.

  • PDF

태양전지 모듈의 효율개선을 위한 지열교환 장치 개발 (Development of geothermal exchanger for efficiency improvement of solar cell module)

  • 이제훈;오훈;김준성;김도웅;박왈서
    • 한국산학기술학회논문지
    • /
    • 제16권4호
    • /
    • pp.2966-2970
    • /
    • 2015
  • 최근 태양광발전은 정부의 재생에너지 지원책에 의해 널리 보급되고 있다. 하지만 발전효율은 태양전지 모듈이 일정온도보다 높게 유지될 때 떨어진다. 따라서 일정온도 이하로 유지하는 것이 필요하다. 본 논문에서는 태양전지 모듈의 효율을 개선하기 위해서 지열교환장치를 개발하였다. 지열교환장치는 태양전지의 열 흡수판과 열전도판 그리고 방열기로 구성된다. 태양전지 모듈의 열은 지열교환 장치에 의해 땅속으로 방열한다. 결과적으로, 지열교환장치는 태양전지모듈의 발전량을 증가시키며, 실험결과는 발생전력이 약 36% 증가함을 보여 주고 있다.

KS C 8562 평가를 통한 CIGS 태양광모듈의 출력 거동 분석 (Current-Voltage Measurement Behavior of the CIGS Solar Module through the Evaluation of KS C 8562 Standard)

  • 김경수
    • Current Photovoltaic Research
    • /
    • 제12권2호
    • /
    • pp.41-47
    • /
    • 2024
  • CIGS solar cells are thin film solar cells that have excellent light absorption coefficient and can be manufactured with high efficiency through the use of low materials. In Korea, they must pass KS certification for home and commercial installation. KS C 8562 is a standard for evaluating the durability of CIGS and thin film amorphous silicon solar modules and deals with contents such as light, temperature, humidity, and mechanical durability. Unlike general crystalline silicon solar modules, the CIGS solar module has a different behavior of output change through these environmental tests, so if it shows 90% or more of the rated output suggested by the manufacturer after the final test, it is judged to be a suitable product. In this paper, the output before and after individual tests was measured through the test method of KS C 8562 to observe the output change and to discover the vulnerabilities of the CIGS solar module when exposed to various environments. Through this, it was confirmed that humidity exposure was the most vulnerable and that it had output recovery characteristics for light (visible light and ultraviolet rays). This study attempted to present the output behavior characteristics and data of the CIGS module at the time when the high efficiency thin film photovoltaic module market is expected to be created in the future.

염전 병행 태양광 발전 시스템 타당성 검토를 위한 기초연구 (Feasibility Study of Salt Farm and Solar Power Paraell System)

  • 강성현;김봉석;김근호;박종성;김덕성;임철현
    • Current Photovoltaic Research
    • /
    • 제9권1호
    • /
    • pp.17-21
    • /
    • 2021
  • In this study, the effect of water level and temperature on the power generation was investigated in a water tank with an aquavoltaic PV module to perform feasibility research for the development of salt farm aquavoltaic system. The silicon solar cell attached to the bottom of each water tank is a 1-cell mini module, and the underwater effects of the crystal phase (19.0~19.9% of single- & 17.9~19.9% of poly-crystalline) of the PV module were investigated, and power generation characteristics for water level (0~10 cm) and temperature (10~40℃) were analyzed. The deterioration coefficients according to the water level and temperature of each single- and poly-crystalline module were investigated at very similar levels such as, -2.01 %/cm and -2.02 %/cm, -0.50 %/℃ and -0.48 %/℃, respectively. Therefore, in salt farm aquavoltaic system, water levels need to maintain as low as possible, and heat-induced degradation is similar to those shown in general land, and no factors have been found to be affected by the underwater environment depending on the determination.

다양한 환경조건에서 태양전지모듈의 PID회복특성 (PID Recovery Characteristics of Photovoltaic Modules in Various Environmental Conditions)

  • 이은석;정태희;고석환;주영철;장효식;강기환
    • 한국태양에너지학회 논문집
    • /
    • 제35권5호
    • /
    • pp.57-65
    • /
    • 2015
  • The Potential Induced Degradation(PID) in PV module mainly affected by various performance conditions such as a potential difference between solar cell and frame, ambient temperature and relative humidity. The positive charges as sodium ions in front glass reach solar cell in module by a potential difference and are accumulated in the solar cell. The ions accelerate the recombination of generation electrons within solar cell under illumination, which reduces the entire output of module. Recently, it was generally known that PID generation is suppressed by controlling the thickness of SiNx AR coating layer on solar cell or using Sodium-free glass and high resistivity encapsulant. However, recovery effects for module with PID are required, because those methods permanently prevent generating PID of module. PID recovery method that voltage reversely applies between solar cell and frame contract to PID generation begins to receive attention. In this paper, PID recovery tests by using voltage under various outdoor conditions as humidity, temperature, voltage are conducted to effectively mitigate PID in module. We confirm that this recovery method perfectly eliminates PID of solar cell according to repeative PID generation and recovery as well as the applied voltage of three factors mainly affect PID recovery.