• Title/Summary/Keyword: Smoke production rate

Search Result 57, Processing Time 0.031 seconds

Study on the combustion performance's classification system for large scale fire tests (실대화재시험의 화재성능 등급분류에 관한 연구)

  • Park, Kye-Won;Im, Hong-Soon;Jeong, Jae-Gun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.99-104
    • /
    • 2008
  • The combustion properties of sandwich panels were tested and analyzed according to ISO 13784-1(Room Corner Test for Sandwich panel building systems) test method for the purpose of establishing the classification of reaction to fire performance. Several variables including heat release rate, smoke production rate, FIGRA, SMOGRA, and so on, were analyzed for specific four materials about sandwich panel systems on each 5 times, totally 20 times. Finally, elements for Classification system were suggested and evaluations for those elements were made.

  • PDF

Applying to ISO 13784-1 fire tests for analyzing the combustion properties of sandwich panel systems (샌드위치 패널 연소특성 분석을 위한 실대규모 화재시험(ISO 13784-1) 적용)

  • Im, Hong-Soon;Park, Kye-Won;Jung, Jae-Gun;Lee, Gil-Yong;Kim, Jeong-Uk;Jeong, Jeong-Ho;Lee, Woo-Seok;Kim, Woon-Hyung
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.112-116
    • /
    • 2008
  • The combustion properties of sandwich panels were tested according to ISO 13784-1(Room Corner Test for Sandwich panel building systems) method to supplement ISO 9705 Room corner test, and analyzed comparatively. Several variables including heat release rate, smoke production rate, FIGRA, SMOGRA, thermal configuration, visual check lists and so on, were analyzed for four materials on sandwich panel systems. Finally, Fire performances of test results on each material by ISO 13784-1 are categorized by applying to the classification system of both EN 13501-1 and Eurefic research program

  • PDF

North Korea Cement Industry in Satellite Imagery (위성사진으로 본 북한의 시멘트 산업)

  • Baek, Chul-Seoung;Seo, Jun-Hyung;Cho, Jin-Sang;Ahn, Ji-Whan;Cho, Kye-Hong
    • Ceramist
    • /
    • v.22 no.2
    • /
    • pp.198-214
    • /
    • 2019
  • The possibility of economic exchange with North Korea is increasing, but there is still a shortage of information of cement industry, which occupies the largest proportion of North Korean construction material industry. Therefore, this study researched the status of cement production facility management using satellite photographs of 16 cement factories in North Korea, and examined the operating status of North Korean cement industry by observing smoke discharged from the chimneys of the cement production facilities. When the satellite photographs were analyzed, it was observed that the monthly stack fog ratio of the North Korean cement factories was 55% in 2016, 60% in 2017 and nearly 65% in 2018. This demonstrates that the average operating ratio has been increasing continuously. However, the operation rate of the five major cement factories reaches the limit, actual cement production is estimated to have maintained the previous level or small increased.

Experiments on the Behavior of Underground Utility Cable in Fire (지하구 케이블의 연소특성 실험)

  • 박승민;김운형;윤명오
    • Fire Science and Engineering
    • /
    • v.16 no.2
    • /
    • pp.75-80
    • /
    • 2002
  • In this paper, some experiments of a heat release rate and toxicity for underground utility 22.9kv cable in fire was conducted and analysed applying plume equation and smoke chamber test separately, A 22.9 ㎸ power cable is selected for testing heat release in ISO 9705 geometry and toxicity production is measured with NES 713 (British-Naval Engineering Standard)test. In test results, Cable heat release reached about 60 ㎾ above 1.2 m from heptane pan and CO generated lethal concentration under 30 min. exposure condition.

A Experimental Study on the Fire Hazard Analysis For Communication Cable in Buildings (건축물내 통신용 케이블의 화재위험성 분석에 관한 실험연구)

  • Hong, Sung-Ho;Choi, Moon-Soo
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.6
    • /
    • pp.20-25
    • /
    • 2011
  • This study presents on the fire hazard analysis of communication cable in buildings. In order to analyze fire hazards for communication cable IEC 60332-1, UL 94 and cone calorimeter test are conducted. The number of cable used to experiment is 10 communication cable which are generally applied to data communication in buildings. The results show that 9 cables do meet the performance requirement of IEC 60332-1 and 8 cables are V-0 classification. IEC 60332-1 and UL 94 test are inadequate for fire hazard classification. The various parameters obtained by cone calorimeter test such as HRR, peak HRR, smoke production rate and so on. Also it is able to evaluate multiply fire hazard for communication cable with cone calorimeter test results.

Study on application of recycled insulation-panel with fire-safety performance (화재성능이 확보된 재생 폐자원 단열재의 활용 연구)

  • Park, Kye-Won;Jeong, Jae-Gun;Kim, Hak-Yong
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.10a
    • /
    • pp.167-170
    • /
    • 2010
  • This study is aiming at analyzing correlation between flashover's time and maximum smoke production rate's time on sandwich panel specimens. For this analysis, KS F ISO 137481-1 has been performed for 23 kinds of sandwich panels which mainly consist of EPS, PIR, PUR, Glass wool and so on. KS F ISO 13784-1 represents real scale reaction-to-fire test and focuses on measuring flashover phenomenon rather than other tests as like ISO 5660-1 and SBI.

  • PDF

Classification of Reaction-to-Fire's Performances on Sandwich Panel Systems by Applying to ISO 13784-1 Fire Tests (실대규모 화재시험(ISO 13784-1)을 적용한 샌드위치 패널 시스템의 연소성능 분류)

  • Park, Kye-Won;Im, Hong-Soon;Jeong, Jae-Gun;Lee, Gil-Yong;Kim, Jeong-Uk;Jeong, Jeong-Ho;Lee, Woo-Seok;Kim, Woon-Hyung
    • Fire Science and Engineering
    • /
    • v.23 no.2
    • /
    • pp.20-26
    • /
    • 2009
  • Reaction-to-Fire's performances such as combustion properties of sandwich panels were tested according to ISO 13784-1 (room corner test for sandwich panel building systems) method which is made for the purpose of supplementing ISO 9705 room corner test, and analyzed comparatively. Several variables including heat release rate, smoke production rate, FIGRA, SMOGRA, thermal configuration, visual check lists and so on, were analyzed for specific four materials on sandwich panel systems. Finally, Reaction-to-Fire's performances of test results on each material by ISO 13784-1 are categorized by applying to the classification systems of both EN 13501-1 and Eurefic Research Program.

Analysis on the Reaction-to-fire's Performance of Sandwich Panel Systems by using ISO 5660-1 and EN 13823 Fire Tests (중소형 화재시험(ISO 5660-1 및 EN 13823)을 이용한 샌드위치패널 연소성능 분석)

  • Park, Kye-Won;Im, Hong-Soon;Jeong, Jae-Gun;Kim, Woon-Hyung
    • Fire Science and Engineering
    • /
    • v.23 no.1
    • /
    • pp.33-39
    • /
    • 2009
  • In this study, the combustion properties, which are called the reaction-to-fire's performance, of sandwich panels were tested and analyzed according to both ISO 5660 (cone calorimeter method) and EN 13823 (SBI). Several variables including ignition time, mass loss, heat release rate, smoke production rate and $O_2$ density about four sandwich panels and four core materials (thermal insulation material) were evaluated. Combustion properties' similarity and difference of sandwich panels and core materials were compared by materials and test methods respectively. Finally test results were evaluated by Japanese standard building code, National Building code of Canada and EN 13501-1 as well.

Fire Tests for Representative Combustibles in Residential Facilities for the Development of Field Commander Training Content (현장지휘관 훈련 콘텐츠 개발을 위한 주거목적시설 대표 가연물 실물화재시험)

  • Moon, Min-Ho;Yang, So-Yeon;Han, Kuk-Il;Lee, Ji-Hee;Kim, Hyung-Jun
    • Fire Science and Engineering
    • /
    • v.34 no.2
    • /
    • pp.22-29
    • /
    • 2020
  • In this study, the fire patterns, heat emissions, and smoke generated by means of fire tests developed for representative combustibles in residential facilities were analyzed from among seven fire types. These combustibles were selected in a previous study to simulate real-world situations and professionalism required while dealing with these types of fires and develop the field commander training content. Consequently, the maximum heat dissipation was recorded as 728.6 kW, followed by the dissipation measured from the combination of a mattress and electric blanket, desk and chair, and TV and mattress. The total heat emission of sofas (226.2 MJ) and the combination of mattress and electric blanket (2,259.5 ㎡) was recorded. In this study, the scope of the tests was limited to the fire characteristics and characteristics of the combustibles, and it is expected that a simulation using various data acquisition methods and FDS would be performed and evaluated at a later stage.

A Study on Characteristic of Eco-friendly Propellant Using GUDN/BTATz (GUDN/BTATz를 적용한 친환경추진제 특성 연구)

  • Jeon, Su-a;Won, Jong-ung;Park, Sung-jun;Park, Jung-ho;Choi, Sunghan
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.24 no.4
    • /
    • pp.41-47
    • /
    • 2020
  • This study aims to develop eco-friendly propellant that reduce the generation of harmful gases such as HCl gas and increase the emmision of nitrogen gas emissions. For this purpose, GUDN(N-Guanylurea dinitramide) and BTATz(3,6-bis(1H-1,2,3,4-tetrazol-5-ylamino)-1,2,4,5-tetrazine), which are low carbon high nitrogen materials, were used instead of AP(Ammonium Perchlorate) and Al(Aluminium), which are gernerally used in solid propellant. The prepared propellants were analyzed for mechanical properties and combustion characteristics, performance and AGARD smoke classification. Compared with AP/Al propellant, GUDN/BTATz propellant tended to decrease mechanical and combustion rate. Also, as a result of the static test after the production of the 4-inch motor, the performance of combustion of the GUDN/BTATz propellant decreased, but it was confirmed that the secondary smoke was improved by reducing harmful gases such as HCl gas.