• Title/Summary/Keyword: Small Generator

Search Result 691, Processing Time 0.033 seconds

Design of Robust $H^{\infty}$ Controller for Water Level Control of Steam Generator (증기발생기 수위 제어를 위한 견실$H^{\infty}$ 제어기 설계)

  • 서성환;조희수박홍배
    • Proceedings of the IEEK Conference
    • /
    • 1998.06a
    • /
    • pp.223-226
    • /
    • 1998
  • The control objective of steam generator water level in the secondary circuit of a nuclear power plant is to regulate the water level at the desired set point. The dynamics of steam generators is non-linear in nature. The task of modelling such plant is very difficult and especially so when plant operating conditions change frequently. In these reasons, conventional PI gains over all pover range will not work efficiently and a manual control is generally used in low power operation. Therefore the robust H$\infty$ controller design method should be required. In this paper, we design the robust H$\infty$ controller for water level control of steam generator using a mixed H$\infty$ optimization with model-matching method. Firstly we choose the desired model that has good disturbance rejection performance. Secondly we design a stabilizing controller to keep the model-matching error small and also provide sufficiently large stability margin against additive perturbations of the nominal plant.

  • PDF

Determination of Co-generator Model Parameters (자가용 발전기 모델 정수 결정)

  • Kim, D.J.;Kim, H.M.;Chun, Y.H.;Kim, J.W.;Jeon, J.H.;Kook, K.S.
    • Proceedings of the KIEE Conference
    • /
    • 2001.05a
    • /
    • pp.236-240
    • /
    • 2001
  • This paper presents the derivation of model parameters against a comparatively small industrial power plant, and validates its model parameters using the stored data measured at the time of on-site generator characteristic testing. Dynamic models such as generator, excitation system, and turbine/governor are mainly dealt in this paper. For the purpose of validation of derived model parameters, the measured results are compared with simulation results. Those of the comparisons between measured results and simulation results show good match.

  • PDF

Design and Characteristic Analysis of Slotless-type Linear Generator with Halbach Array (Halbach 영구자석 배열의 공심형 선형발전기의 설계 및 특성 해석)

  • Jeong, Su-Kwon;Han, Kwang-Gyu;Ahn, Ho-Jin;Jang, Ki-Bong;Kim, Gyu-Tak
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.856-857
    • /
    • 2008
  • Wave power generation as an environmentally -friendly energy has received the attention. In this paper, therefore, the tubular type Permanent Magnet Linear Synchronous Generator (PMLSG) is proposed for wave power generation. The characteristics of tubular type PMLSG are investigated by analysis using a Finite Element Analysis (FEA). Moreover, the operating performance of generator under no-load and load with variable resistance is examined. And Taguchi method is applied for considering tolerance in manufacture. The results of FEA show that proposed tubular type PMLSG is a useful solution for small-scale wave power generation.

  • PDF

A Study on the Modeling and Design of Single Phase Induction Generators

  • Kim Cherl-Jin;Lee Kwan-Yong
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.5B no.4
    • /
    • pp.331-336
    • /
    • 2005
  • With increasing emphasis on non-conventional energy systems and autonomous power generation, development of improved and appropriate generating systems has recently taken on greater significance. This paper describes the performance analysis of a single phase self-excited induction generator (SEIG), suitable for autonomous/standby power systems. The system is also appropriate for wind energy systems and small portable systems. Both windings of the induction machine, the main and the auxiliary, are utilized. One winding will be devoted to the supply excitation current only, by being connected to the excitation capacitor, while the load is connected across the other winding. As the design of excitation, the minimum of self-excited capacitor connected auxiliary winding is determined as the suitable value using a circuit equation of auxiliary winding. For the steady state analysis, the equivalent circuit of the single-phase induction generators is used as a basis for modeling using the double-revolving field theory. The validity of the designed generator system is confirmed by experimental and computed results.

A Study on Stable Operating for Buan S/S Byunsan D/L (2728 02) Power Distribution Area Connected with Wind Power Generator (부안 S/S 변산 D/L(2728 02) 공급구역을 대상으로 한 풍력발전시스템 계통연계 시 보호협조 방안)

  • Jang, Mi-Hye;Shin, Baek-Sik;Song, Weon-Jin;Kim, Yeong-Min;Kim, Dong-Yong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.508-509
    • /
    • 2008
  • A creation of large and small scale wind farm was considered to proper already, as according to real Jeonbuk Saemangeum project. A grow larger to be construction of the new and renewable energy thema park as well as creation possibility of large scale wind farm afterward. Therefore, in this paper was proposed a counterplan on D/L protection cooperation of Buan S/S Byunsan D/L (2728 02) power distribution line in case of connected with wind power generator.

  • PDF

$H_\infty$Control Synthesis for Robust Control of a Turbo-Generator (터-빈 발전기의 견실성 제어를 위한$H_\infty$제어 시스템 설계)

  • Chung, Dae-Won;Kim, Kern-Joong
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.5
    • /
    • pp.622-628
    • /
    • 1999
  • This paper presented to design a robust turbo-generator control system using {{{{ { H}_{$\infty$ } }}}} control synthesis for improving small-signal stability. Application study of{{{{ { H}_{$\infty$ } }}}} control synthesis is more appropriate in this system since a turbo-generator system is usually operated under circumstance of unmeasurable modelling uncertainty and external disturbance. The{{{{ { H}_{$\infty$ } }}}} control theory was briefly reviewed for good understanding and the reasonable approach. The design results are simulated for a case study and to check the system performance in comparison with currently operating Lead/Lag filtered PSS performance.

  • PDF

Power System Stabilizer Design of a Turbo-Generator using LQG/LTR Control Synthesis (LQG/LTR에 의한 터-빈 발전기의 PSS 說計)

  • Chung, Dae-Won;Kim, Kern-Joong
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.8
    • /
    • pp.965-971
    • /
    • 1999
  • This paper presented to design the power system stabilizer(PSS) for a turbo-generator system using LQG/LTR control synthesis for improving small-signal stability. Application study of LGG/LTR control synthesis is more appropriate in this system since a turbo-generator system is usually operated under circumstance of unmeasurable uncertainties and external disturbance. The LQG/LTR control theory was briefly reviewed for good understanding and the reasonable design approach. The design results are simulated for a case study and to check the system performance in comparison with currently operating lead-lag filtered PSS performance.

  • PDF

Effective Algorithm in Steady-State Analysis for Variable-Speed and Constant-Speed Wind Turbine Coupled Three-Phase Self-Excited Induction Generator

  • Ahmed, Tarek;Nishida, Katsumi;Nakaoka, Mutsuo
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.3B no.3
    • /
    • pp.139-146
    • /
    • 2003
  • In this paper, the steady-state operating performance analysis for the three-phase squirrel cage rotor self-excited induction generator (SEIG) driven by a variable-speed prime mover (VSPM) in addition to a constant-speed prime mover (CSPM) is presented on the basis of an effective algorithm based on its frequency-domain equivalent circuit. The operating characteristics of the three-phase SEIG coupled by a VSPM and/or a CSPM are evaluated on line processing under the condition of the electrical passive load parameters variations with simple and efficient computation processing procedure in unregulated voltage control loop scheme. A three-phase SEIG prototype setup with a VSPM as well as a CSPM is implemented for the small-scale clean renewable and alternative energy utilizations. The experimental operating characteristic results are illustrated and give good agreements with the simulation ones.

Vibration Monitoring of a 1kW Small Wind Turbine Generator (1kW소형 풍력발전기의 진동 모니터링)

  • Kim, Seock-Hyun;Nam, Y.S.;Yoo, N.S.;Kim, Yun-Ho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.308-311
    • /
    • 2006
  • A vibration monitoring is performed on a 1kW class stand alone wind turbine(W/T). When a W/T model is developed, general performance under various wind condition should be verified to introduce the product in the market. Especially, vibration characteristics within operating speed range are very important in the aspect of structural stability as well as generator's electrical efficiency. This paper examines the vibration performance of a home made 1kW W/T Various data of the W/T model are acquired in real time using a remote vibration monitoring system installed in Daekwanryung test site. Vibration stability of the W/T structure is diagnosed based upon the data and the result is used to estimate the applicability of the W/T model.

  • PDF

Design on Pipeline Architecture for the Low and Column Address Generator of 2D DCT/IDCT (2D DCT/IDCT의 행, 열 주소생성기를 위한 파이프라인 구조 설계)

  • 노진수;박종태;문규성;성해경;이강현
    • Proceedings of the Korea Multimedia Society Conference
    • /
    • 2003.05b
    • /
    • pp.14-18
    • /
    • 2003
  • This paper presents the pipeline architecture for the low and column address generator of 2D DCT/IDCT(Discrete Cosine Transform/Inverse Discrete Cosine Transform). For the real time process of image data, it is required that high speed operation and small size hardware In the proposed architecture, the area of hardware is reduced by using the DA(distributed arithmetic) method and applying the concepts of pipeline on the parallel architecture. As a results, the designed pipeline of the low and column address generator for 2D DCT/IDCT architecture is implemented with an efficiency and high speed compared as the non-pipeline architecture. And the operation speed is improved about 50% up. The design for the proposed pipeline architecture of DCT/IDCT is coded using VHDL.

  • PDF