• 제목/요약/키워드: Shifted Power Functions

검색결과 11건 처리시간 0.026초

압입시험에서 하중제하곡선의 강성율에 관한 고찰 (A Study on the Unloading Stiffness of Instrumented Indentation Tests)

  • 이병섭;이호진;이봉상
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2003년도 추계학술대회논문집
    • /
    • pp.168-171
    • /
    • 2003
  • Instrumented indentation tests have been used for estimating material properties. In order to analyze deformation characteristics with various factors, the unloading stiffness should be properly determined from the elastic behaviour. In general, the unloading stiffness is obtained from shifted power functions fitting to indentation unloading curves. But, the functions give often a poor representation of actual data. In this study, control conditions for fitting unloading curves by shifted power functions were investigated. The current efforts may provide useful information about unloading process and valid unloading stiffness.

  • PDF

계장화 압입 시험에서 하중 제거 곡선의 강성률에 관한 고찰 (A Study on the Unloading Stiffness of Instrumented Indentation Tests)

  • 이병섭;이호진;이봉상
    • 소성∙가공
    • /
    • 제13권1호
    • /
    • pp.21-26
    • /
    • 2004
  • Instrumented indentation tests have been used for estimating material properties. In order to analyze deformation characteristics with various factors, the unloading stiffness should be properly determined from the elastic behavior. The unloading stiffness is generally obtained from the shifted power functions fitting with the experimental unloading data. However, the functions often give rise to a poor representation of actual data, and also the unloading stiffness is governed by unloading condition. In this study, both numerical and experimental conditions to obtain proper unloading stiffness were investigated. The result showed that the amount of unloading ratio and hold time played an important role in fitting the unloading curves. The current efforts can successfully provide the unloading stiffness for indentation material properties.

Digital Active Load Sharing Control of Paralleled Phase-Shifted Full-Bridge Converters

  • Seong, Hyun-Wook;Cho, Je-Hyung;Moon, Gun-Woo;Youn, Myung-Joong
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2010년도 하계학술대회 논문집
    • /
    • pp.129-130
    • /
    • 2010
  • For the high power demand and N+1 redundancy, this paper presents the digital load share (LS) controller design and the implementation of paralleled phase-shifted full-bridge converters (PSFBC) used in distributed power systems. By adopting the digital control strategy, separately used ICs for PSFBC and LS control functions in analog systems can be merged into a cost-effective digital controller. To compensate and stabilize both PSFBC and LS loops with the direct digital design approaches, small-signal model of the system is derived in discrete-time domain. The steady-state and dynamic load sharing performances are also investigated. Experimental results from two 1.2 kW paralleled PSFBC modules are shown to verify the proposed work.

  • PDF

TURBULENCE STATISTICS FROM SPECTRAL LINE OBSERVATIONS

  • LAZARIAN A.
    • 천문학회지
    • /
    • 제37권5호
    • /
    • pp.563-570
    • /
    • 2004
  • Turbulence is a crucial component of dynamics of astrophysical fluids dynamics, including those of ISM, clusters of galaxies and circumstellar regions. Doppler shifted spectral lines provide a unique source of information on turbulent velocities. We discuss Velocity-Channel Analysis (VCA) and its offspring Velocity Coordinate Spectrum (VCS) that are based on the analytical description of the spectral line statistics. Those techniques are well suited for studies of supersonic turbulence. We stress that a great advantage of VCS is that it does not necessary require good spatial resolution. Addressing the studies of mildly supersonic and subsonic turbulence we discuss the criterion that allows to determine whether Velocity Centroids are dominated by density or velocity. We briefly discuss ways of going beyond power spectra by using of higher order correlations as well as genus analysis. We outline the relation between Spectral Correlation Functions and the statistics available through VCA and VCS.

위성통신안테나 추적제어를 위한 DSP 기반의 협대역신호 전력 검출기 (DSP based Narrow-Band Signal Power Detector for Tracking Control of Satellite Antenna)

  • 김원호
    • 융합신호처리학회논문지
    • /
    • 제7권4호
    • /
    • pp.184-188
    • /
    • 2006
  • 본 논문은 협대역의 위성통신 수신신호 전력을 측정하여 이동형 위성통신 안테나를 추적제어하기 위한 DSP 기반의 협대역 위성통신 신호전력 검출기를 제안한다. 기존의 아날로그 검출방식에 의한 협대역 위성통신 신호전력 검출기는 위성 전파경로 상에서 발생되는 반송파의 중심주파수 천이로 인해 고정된 아날로그 필터대역을 통과하여 검출되는 신호 전력의 오차가 심하고 전송 신호의 대역폭 가변에 따른 아날로그 필터의 대역폭을 변경하기가 용이하지 않다. 따라서 이러한 반송파 주파수 천이에 영향 받지 않고 가변 하는 신호 대역폭에 대응하는 필터를 실시간으로 프로그래머블하게 지원하기 위하여 DSP 기반의 협대역 디지털 위성통신 신호전력 검출기를 제안하였다. 제안된 협대역 위성통신 신호전력 검출 알고리즘은 FFT를 이용하여 주파수 천이된 협대역 위성통신 신호의 주파수를 탐색하고 프로그래머블한 디지털 필터를 선택하여 필터링한 다음, 일정구간 주기로 신호전력을 계산하여 12비트 해상도로 출력하는 기능을 가진다. TMS320C5402 DSP 칩을 기반으로 설계 제작된 신호전력 검출기의 실제 시험을 통하여 제시된 요구기능과 규격을 만족하면서 동작함을 검증하였고 실용성을 확인하였다.

  • PDF

모서리 경계조건을 만족하는 접지된 2개의 유전체층 위의 도체띠 격자구조에 의한 TM 산란의 해 (Solution of TM Scattering by a Conductive Strip Grating Over the Grounded Two Dielectric Layers with Edge Boundary Condition)

  • 윤의중
    • 한국항행학회논문지
    • /
    • 제17권4호
    • /
    • pp.429-434
    • /
    • 2013
  • 본 논문에서는 모서리 경계조건을 만족하는 접지된 2개의 유전체층 위의 완전도체띠 격자구조에 의한 TM(Transverse Magnetic) 산란 문제를 수치해석 방법인 FGMM (Fourier Galerkin Moment Method)를 이용하여 해석하였다. TM 산란에 대하여 도체띠에 유도되는 표면 전류밀도는 스트립 양 끝에서 매우 큰 값이 예측되므로, 이때 도체띠에 유도되는 표면 전류밀도는 1종 Chebyshev 다항식과 적절한 모서리 경계조건을 만족하는 함수의 곱의 급수로 전개하였다. 전반적으로, 접지평면 위에 유전체층의 비유전율의 값이 증가하면, 반사전력의 급변점에 대한 스트립 폭은 더 큰 값으로 이동하였다. 수치결과들은 기존 논문들과 비교하여 급속한 수렴해와 좋은 일치를 보였다.

비교쇼핑 에이전트의 설계와 구현 (Design and Implementation of a Comparative Shopping Agent for E-Commerce)

  • 최무진;황진열
    • 경영정보학연구
    • /
    • 제7권1호
    • /
    • pp.97-113
    • /
    • 2005
  • 본 논문은 B2C 온라인 인터넷 쇼핑을 돕기 위한 비교쇼핑 에이전트를 설계하고 이를 구현하는데 목적을 두고 있다. 오프라인 상점에서 상품을 구매할 때 구매자가 판매원에게 제품의 제조사, 모델, 기능 또는 가격대를 설명하면 판매원이 해당 상품들을 보여주거나 카탈로그를 보여준다. 구매자는 상품의 기능이나 디자인을 비교하면서 적절한 상품군을 정한 후 가격을 비교한 다음에 가장 싼 곳에서 상품을 구입한다. 본 논문이 소개할 비교쇼핑 에이전트 ${\ulcorner}$PriceMeter${\lrcorner}$는 이러한 구매 행동에 최대한 부합 되도록 설계하였다. 구매자가 원하는 제조사, 가격, 기능 등을 선택한 후 검색하면 해당되는 상품들의 설명과 가격 정보들을 이 비교쇼핑 에이전트가 취합하여 보여준다. 마음에 드는 상품들을 카탈로그 양식으로 비교해서 볼 수도 있고, 프린트 양식으로 출력할 수도 있다. 특정 상품을 클릭하면 해당 상품을 판매하는 쇼핑몰들의 정보와 판매 가격을 함께 보여주며, 구매 아이콘을 클릭하면 쇼핑몰의 해당 상품 페이지로 이동할 수 있도록 하고 있다. B2C 전자상거래에 있어 비교쇼핑 에이전트의 구현과 확산은 구매자에게 더 많은 정보와 권한을 제공함으로써 소비자 중심의 유통경제를 한 걸음 앞당길 수 있다. 특정 상품에 대한 가격과 상세 정보를 일목요연하게 제공받는 구매자들은 보다 현명한 구매를 할 수 있으며, 거래과정에서 판매자(생산자)와 구매자의 협상력이 구매자에게로 옮겨질 수 있다. 본 논문이 제시한 비교쇼핑에이전트는 소비자 중심의 사이버 유통시대를 촉진하는데 일익을 담당하는데 그 의의가 있다.

산업용 임베디드 시스템 플랫폼 개발 (Development of Industrial Embedded System Platform)

  • 김대남;김교선
    • 전자공학회논문지CI
    • /
    • 제47권5호
    • /
    • pp.50-60
    • /
    • 2010
  • 지난 반세기 동안 컴퓨터 시스템의 발전으로 개인용 컴퓨터와 소프트웨어 산업은 유래 없는 호황을 누렸다. 21세기에 들어서는 이러한 흐름이 모바일 기기로 점차 이동하면서 임베디드 시스템 시장이 폭발적으로 증가하였다. 휴대전화, 내비게이션 시스템, PMP 등의 휴대용 멀티미디어 기기들은 시장에 쏟아져 나온 반면에 대부분의 산업용 제어시스템은 여전히 단순제어 시스템에 의존하여 제품이 개발되고 있다. 실제로 이를 첨단 하드웨어와 소프트웨어의 기술로 전환하려고 해도 그 수요가 모바일 시장에 비해 낮아 부품수급이 어렵고 가격이 상승하는 문제를 안고 있으며 기술개발 시 발생하는 많은 비용과 인력은 기업 입장에서는 투자 부담이 될 수밖에 없다. 그러나 미래 고객들에게 제품에 대한 기업 이미지를 끌어올리기 위해서는 고성능 시스템의 하드웨어와 소프트웨어 플랫폼 개발이 반드시 필요하다. 본 논문에서는 이러한 문제점들을 해결하기 위해서 네트워크 임베디드 시스템의 최적화된 하드웨어 플랫폼과 소프트웨어 플랫폼을 개발하였다. 개발된 플랫폼은 멀티미디어 기능을 추가하여 고급형 제품을 위한 플랫폼으로 제작하였다. 멀티미디어 기능을 구현하기 위해서 텔레칩스 사의 멀티미디어 프로세서인 TCC8300을 기반으로 개발하였으며 프로세서 내부의 다양한 병렬하드웨어 기능을 이용함으로써 회로상의 부품의 수를 최소화 하고 성능 향상과 더불어 전력소모량을 최소화하였다. 그리고 소프트웨어의 기술비용(로열티)을 없애기 위해서 오픈소스 기반의 운영체제인 임베디드 리눅스와 오픈소스 기반의 그래픽 라이브러리인 TinyX와 GTK+를 이용하여 GUI(Graphic User Interface)를 구현하였다. 또한 개발된 플랫폼을 이용하여 여러 가지 방식의 YUV2RGB 프레임 변환 실험 및 측정을 통해서 성능 및 프레임별 변환 시에 소모되는 전력량을 계산하였고 플랫폼의 각 부분별 동작에 대한 전력소모량 측정을 통해서 플랫폼 구성 시 필요한 전력과 성능을 예측할 수 있도록 하였다. 응용제품을 개발할 때 주어진 기능 및 성능 그리고 저전력 등의 사양이 구현 가능한지 분석하고 절충할 때 사용할 수 있는 모델식을 개발하였고 이를 활용하여 직접 제작해 봄으로써 신뢰성을 입증하였다. 이 때, 하드웨어 부품들은 휴대폰 생산 시에 사용되는 부품들을 사용함으로써 저가의 부품을 안정적으로 수급하여 대량생산을 용이하게 하였다.

한국농촌지도사업(韓國農村指導事業)의 변동(變動) (Changes in Agricultural Extension Services in Korea)

  • 후지타야스키;이용환;김성수
    • 농촌지도와개발
    • /
    • 제7권1호
    • /
    • pp.155-166
    • /
    • 2000
  • 1994년 가을 한국을 방문하였을 때 놀란 것 온 도시 근교에 숲과 같이 세워진 고층 아파트 단지와 그 수요의 배경이 된 서울, 수원을 비롯한 수도권의 인구 집중이었다. 이러한 인구 집중을 가져온 것은 바로 제2차, 3차 산업의 발달이었다. 그 이후 6년만인 2000년 3월에 다시 농촌과 농촌지도사업의 변화 동향을 살펴보기 위하여 농가 방문, 도 농업기술원 및 시 ${\cdot}$ 군농업 기술센터를 방문하면서 더욱 진전된 아파트군과 도시 근교의 비닐 하우스 단지였으며, 이는 한국이 지속적인 경제 발전을 하고 있다는 한 증거였다. 한국은 1997년에 내습한 통화위기로 IMF의 구제 금융을 받게 되었고, 이로 인하여 한국 경제는 IMF의 관리하에 있었으나 1년만에 회복의 기미를 보이기 시작하였으며, 1999에는 GDP 성장률이 10.7%에 달하였다. 한국 정부는 이 시기에 구조개혁을 단행하여 금융, 기업, 노동, 공공의 각 부분에 개혁을 단행하였다. 특히 정부로서는 정부 조직을 개편하여 지방화, 행정 조직 인원의 삭감, 농업 예산의 축소하는 방향으로 나아갔고 공기업을 민영화하여 농업 단체의 통합, 각종 규제를 철폐하였다. 중앙 정부의 권력이 지방으로 많이 이양되어 시장, 군수 등의 권한이 크게 늘어났다. 농촌지도사업도 IMF 관리하의 정부 조직 개편 및 규제 완화의 대상이 되었다. 지금까지 중앙 정부 소속이었던 농촌지도 사업이 지방화의 영향으로 시 ${\cdot}$ 군으로 이관되었다. 이것에 동반하여 농촌지도소 수의 축소(64%), 지도 직원의 감원(24%), 사업 예산의 감소 등으로 나타났다. 이러한 개편 과정에서 농촌지도사업의 기본적인 방향을 정하는 것은 중앙의 농촌진흥청이 맡고 인사와 기술 개발, 지원은 도농업기술원, 사업운영 책임은 시 ${\cdot}$ 군에서 맡는 체제로 개편되었다. 시 ${\cdot}$ 군 단계의 농촌지도사업은 담당 기구가 농촌지도소에서 농업기술센터로 그 명칭이 변경되었고, 설치권자가 군수로 되었으며, 그 기능에 기술 개발 업무가 더해졌으며, 농촌지도사 및 생활지도사의 수가 크게 감소되었다. 최근에 한국의 농촌 및 농촌지도사업을 관찰한 결과, 이러한 중앙, 도 시 군의 지도 기능 분담이 그렇게 잘 인식되어 있는 것만은 아닌 면도 있는 것으로 보였다. 이러한 구조 개선을 계기로 해서 농촌의 현실을 반영한 실효성 있는 농촌진흥에 기여할 수 있는 농촌지도사업으로 재출발한다는 의의를 살릴 수 있도록 농촌진흥청은 농업기술센터의 동태를 철저하게 살피고 이와 관련한 도농업기술원의 대응을 파악하여 이를 기초로 기능을 발휘하도록 만들어야 할 것이다. 국가에서 이관된 현지의 농촌지도 거점인 농업기술센터에 관하여 농촌지도소가 개칭되어 농업기술센터가 되었고 조직적인 면에서도 기술개발과가 설치되었다. 이는 현지에서의 기술 개발이 가능하게 된 점과 현지에서 원하는 과제를 신속하게 대응하여 도와 국가의 시험연구 과제로 삼을 수 있게 된 것은 시험 연구 사업에서 크게 평가받을 만한 발전이라 할 것이다. 그러나, 농촌지도 직원이 다른 행정 업무도 겸무하여 될 경우 영농 환경을 좋게 하는 직접적인 행정에 관한 업무에서는 겸무하므로서 농가도 편리해지고, 보급지도의 효과도 촉진되는 경우가 있으나 검사, 취체 업무는 반드시 피해야 할 일이다. 동일인이 이것을 담당하게 되면 농가에게 안심감을 잃어버리고 보급 효과는 기대할 수 없게 될 것이다. 한국의 농촌지도사업의 보급 내용은 농업자재의 절약, 첨단농업기술의 개발, 이를 기반으로 수출농업의 촉진과 생산성 향상, 시장에 강한 농업의 구축 등에 힘을 쏟고 있는 것으로 보였다. 그러나 이러한 농업의 추구는 약탈농업을 추구하는 등 지속적 농업이 되지 않을 가능성이 높아지게 된다. 앞으로 지속적인 농업에 관하여 보다 더 많은 관심을 기울여야 할 것이다. 선진농가들은 기술이나 경영 혁신을 위하여 연구 개발을 위한 정보의 수집과 연구회의 필요성을 크게 강조하고 있었다. 그러나 이러한 선진 농가 이외에 소규모의 농업소득이 낮은 농가도 있었다. 이러한 농가에게는 농업경영에 대한 방향 설정과 추진 방법에 대한 적절한 상담 상대가 없는 것으로 보였다. 이러한 농가들에 대한 시의적절한 정보의 전달, 자력으로 기술과 경영 방책을 만들어내는 힘을 길러주는 지도가 필요하다. 이를 위한 방책으로 그룹의 육성과 가입 촉진이 유효할 것이다. 따라서 한국에 있어서 농촌지도 방법은 크게 두 가지 대상을 의식하여 대 선진농가의 경우에 는 상담 기능, 대 소규모 농가의 청우에는 전달 ${\cdot}$ 교육 기능의 발휘에 있을 것이다. 상담 기능은 정보의 제공과 과도하지 않은 방책을 선택 할 수 있도록 지도 조언하는 것이, 전달 ${\cdot}$ 교육 기능은 과제해결 과정을 체득하게 하는 것이다. 이를 위하여 인터넷의 활용 방법, e-메일에 의한 정보교환 시스템화 등의 연구가 진행되고 있다. 인원의 감소나 겸무화의 진행에 따라 이러한 업무의 수행이 쉬운 것은 아니라고 생각되고, 일 대 일의 지도는 어려울 것이나 집단 지도로는 가능한 측면도 있을 것으로 사료된다.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF