• 제목/요약/키워드: Sensor Sensitivity

검색결과 1,892건 처리시간 0.029초

VERTICAL OZONE DENSITY PROFILING BY UV RADIOMETER ONBOARD KSR-III

  • Hwang Seung-Hyun;Kim Jhoon;Lee Soo-Jin;Kim Kwang-Soo;Ji Ki-Man;Shin Myung-Ho;Chung Eui-Seung
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 2004년도 한국우주과학회보 제13권2호
    • /
    • pp.372-375
    • /
    • 2004
  • The UV radiometer payload was launched successfully from the west coastal area of Korea Peninsula aboard KSR-III on 28, Nov 2002. KSR-III was the Korean third generation sounding rocket and was developed as intermediate step to larger space launch vehicle with liquid propulsion engine system. UV radiometer onboard KSR-III consists of UV and visible band optical phototubes to measure the direct solar attenuation during rocket ascending phase. For UV detection, 4 channel of sensors were installed in electronics payload section and each channel has 255, 290, 310nm center wavelengths, respectively. 450nm channel was used as reference for correction of the rocket attitude during the flight. Transmission characteristics of all channels were calibrated precisely prior to the flight test at the Optical Lab. in KARI (Korea Aerospace Research Institute). During a total of 231s flight time, the onboard data telemetered to the ground station in real time. The ozone column density was calculated by this telemetry raw data. From the calculated column density, the vertical ozone profile over Korea Peninsula was obtained with sensor calibration data. Our results had reasonable agreements compared with various observations such as ground Umkhr measurement at Yonsei site, ozonesonde at Pohang site, and satellite measurements of HALOE and POAM. The sensitivity analysis of retrieval algorithm for parameters was performed and it was provided that significant error sources of the retrieval algorithm.

  • PDF

상용 보호열판법 열전도율 측정장비를 사용한 열유속법의 열전도율 값 보정에 대한 실험적 연구 (Experimental Study on Correction of Thermal Conductivity Obtained by Heat Flow Method using Commercial Guarded Hot Plate Method Apparatus)

  • 이진성;김경수;김유일;우석민;윤승진
    • 한국해양공학회지
    • /
    • 제29권2호
    • /
    • pp.169-174
    • /
    • 2015
  • This paper addresses experimental methodologies to measure the temperature-dependent thermal conductivity of the insulation materials popularly used for LNG cargo containment systems. The measurement techniques considered in this paper are the guarded hot plate (GHP) method and heat flow method (HFM). The former is based on the power supplied to the hot plate to keep the temperature constant, and the latter is based on a direct heat flux measurement. In order to improve the accuracy of the HFM, the thermal conductivity obtained by GHP was cross-compared with the HFM results, and a calibration factor was derived. It was found that the thermal conductivities measured by the two methods corresponded well under room temperature, but the deviation tended to slightly increase as the temperature decreased. Because of the easy installation and operability of HFM, it can be used to measure thermal conductivity in a large scale mock-up test or unit insulation panel test, where the GHP method is difficult to apply.

154[KV] 가공송전선로 아래에서 전장분포의 측정과 분석 (Measurement and Analysis of Electric Filed Distributions under 154[kV] Overhead Tranamission Lines)

  • 이복희;이정기;안창환;이경옥;박동화;곽희로;송진호
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제11권1호
    • /
    • pp.92-98
    • /
    • 1997
  • 본 노문에서는 154[kv] 가공송전선로의 주변에서 발생하는 극저주파 영역(ELF)의 전장의 측정·분석한 결과에 대해서 기술하였다. 상용주파수와같은 저주파 성분의 검출을 3차원 평행평판형 전장센서를 제작하였으며, IEEE에서 추천하는 실험방법을 적용하여 교정실험을 수행한 바 제작된 전계측정장치의 수파수 대력은 7[Hz]에서 2.7[MHz]이고, 응답 감도는 0.0094[mV/V/m]이었다. 154[kv] 2회선 가공송전선로 아래에서 전장의 실측실험을 수행하고, 그 결과를 분석하였다. 가공송전선 아래에서 의전장의 분포는 주변의 금속 물체 때문에 비대칭 형상을 나타내었으며, 그리고 최대 전계의 세기는 3[kV/m]이하이었다. 본 연구에서의 측정 결과는 관련 여러 국제기관의 제한·권고치를 만족시키고 있다.

  • PDF

도로터널 조명시설의 설계기준

  • 지철근;이진우
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제11권1호
    • /
    • pp.14-23
    • /
    • 1997
  • 본 논문에서는 154[㎸] 가공송전손로의 주변에서 발생하는 극저주파 영역(ELF)의 전장의 측정 분석한 결과에 대해서 기술하였다. 상용주파수와 같은 저주파 성분의 검출을 위한 3차원 평행평판형 전장센서를 제작하였으며, IEEE에서 추천하는 실험방법을 적용하여 교정실험을 수행한 바 제작된 전계측정장치의 주파수 대역은 7[Hz]에서 2.7[MHz]이고, 응답 감도는 0.094[mV/V/m]이었다. 154[㎸] 2회선 가공송전선로 아래에서 전장의 실측 실험을 수행하고, 그 결과를 분석하였다, 가공송전선 아래에서의 전장의 분포는 주변의 금속 물체 때문에 비대칭 형상을 나타내었으며 그리고 최대 전계의 세기는 3[㎸/m]이하이었다. 본 연구에서는 측정 결과는 관련 여러 국제기관의 제한 권고치를 만족시키고 있다.

  • PDF

Co계 아몰퍼스리본을 이용하여 제작한 마안더패턴의 고주파 임피던스특성 (High Frequency Impedance of Meander Pattern Fabricated by Co-base Amorphous Ribbon)

  • 신광호;박경일;사공건;송재연;김영학
    • 한국자기학회지
    • /
    • 제13권4호
    • /
    • pp.160-164
    • /
    • 2003
  • 연자성이 우수한 Co계 아몰퍼스리본을 리소그래피와 에칭을 통하여 미안더타입(meande, type)의 미소패턴으로 가공하고 표피효과가 현저하게 나타나는 300 KHz∼l ㎓의 주파수영역에서 고주파임피던스, 저항, 인덕턴스에 미치는 외부자기장의 영향을 조사하였다. 제작한 아몰퍼스리본의 미안더패턴은 자기장중 열처리를 통하여 폭방향으로 자기용이축이 유도되어 있었으며 패턴의 길이방향으로 인가된 외부자기장에 대하여 민감한 임피던스의 변화를 나타내었다. 임피던스는 약 13 Oe부근의 인가자기장에서 최대값을 나타내었으며 50 MHz에서 11 Oe의 인가 자기장에 대하여 약 210%의 임피던스 변화율을 나타내었다.

[NiFe/NiFeCuMo/NiFe]/FeMn 다층박막의 교환결합력과 보자력에 관한 특성 연구 (Exchange Bias Field and Coercivity of [NiFe/NiFeCuMo/NiFe]/FeMn Multilayers)

  • 최종구;이상석
    • 한국자기학회지
    • /
    • 제21권4호
    • /
    • pp.132-135
    • /
    • 2011
  • 초연자성을 갖는 코네틱(NiFeCuMo) 박막을 NiFe 박막 사이에 삽입한 삼층박막 위에 반강자성체 FeMn을 증착한 다층박막에서 NiFe와 NiFeCuMo 박막의 두께에 따른 교환결합력과 보자력에 관한 특성을 조사하였다. 특히 NiFeCuMo 박막의 두께가 1 nm일 때 NiFe 박막 사이에 삽입한 삼층박막 위에 반강자성체 FeMn을 증착한 다층박막의 교환결합력은 최댓값을 나타내었다. 고정층과 자유층에 각각 NiFeCuMo 박막을 삽입하여 초연자성의 바이오센서용 거대자기저항-스핀밸브(giant magnetoresistive-spin valves; GMR-SV) 소자를 개발할 수 있는 가능성을 보여주었다.

수열합성법으로 합성된 산화구리 나노막대의 일산화질소 가스 감지 특성 (Nitrogen Monoxide Gas Sensing Properties of CuO Nanorods Synthesized by a Hydrothermal Method)

  • 박수정;김효진;김도진
    • 한국재료학회지
    • /
    • 제24권1호
    • /
    • pp.19-24
    • /
    • 2014
  • We report the nitrogen monoxide (NO) gas sensing properties of p-type CuO-nanorod-based gas sensors. We synthesized the p-type CuO nanorods with breadth of about 30 nm and length of about 330 nm by a hydrothermal method using an as-deposited CuO seed layer prepared on a $Si/SiO_2$ substrate by the sputtering method. We fabricated polycrystalline CuO nanorod arrays at $80^{\circ}C$ under the hydrothermal condition of 1:1 morality ratio between copper nitrate trihydrate [$Cu(NO_2)_2{\cdot}3H_2O$] and hexamethylenetetramine ($C_6H_{12}N_4$). Structural characterizations revealed that we prepared the pure CuO nanorod array of a monoclinic crystalline structure without any obvious formation of secondary phase. It was found from the gas sensing measurements that the p-type CuO nanorod gas sensors exhibited a maximum sensitivity to NO gas in dry air at an operating temperature as low as $200^{\circ}C$. We also found that these CuO nanorod gas sensors showed reversible and reliable electrical response to NO gas at a range of operating temperatures. These results would indicate some potential applications of the p-type semiconductor CuO nanorods as promising sensing materials for gas sensors, including various types of p-n junction gas sensors.

MRAS Based Sensorless Control of a Series-Connected Five-Phase Two-Motor Drive System

  • Khan, M. Rizwan;Iqbal, Atif
    • Journal of Electrical Engineering and Technology
    • /
    • 제3권2호
    • /
    • pp.224-234
    • /
    • 2008
  • Multi-phase machines can be used in variable speed drives. Their applications include electric ship propulsion, 'more-electric aircraft' and traction applications, electric vehicles, and hybrid electric vehicles. Multi-phase machines enable independent control of a few numbers of machines that are connected in series in a particular manner with their supply being fed from a single voltage source inverter(VSI). The idea was first implemented for a five-phase series-connected two-motor drive system, but is now applicable to any number of phases more than or equal to five-phase. The number of series-connected machines is a function of the phase number of VSI. Theoretical and simulation studies have already been reported for number of multi-phase multi-motor drive configurations of series-connection type. Variable speed induction motor drives without mechanical speed sensors at the motor shaft have the attractions of low cost and high reliability. To replace the sensor, information concerning the rotor speed is extracted from measured stator currents and voltages at motor terminals. Open-loop estimators or closed-loop observers are used for this purpose. They differ with respect to accuracy, robustness, and sensitivity against model parameter variations. This paper analyses operation of an MRAS estimator based sensorless control of a vector controlled series-connected two-motor five-phase drive system with current control in the stationary reference frame. Results, obtained with fixed-voltage, fixed-frequency supply, and hysteresis current control are presented for various operating conditions on the basis of simulation results. The purpose of this paper is to report the first ever simulation results on a sensorless control of a five-phase two-motor series-connected drive system. The operating principle is given followed by a description of the sensorless technique.

마이크로 프로세서 기반 Lock-In-Amp를 이용한 텍스타일 직물전극의 체온 측정에 관한 연구 (A Study on Body Temperature Measurement of Woven Textile Electrode Using Lock-In-Amp based on Microprocessor)

  • 이강휘;이성수;이정환;송하영
    • 전기학회논문지
    • /
    • 제66권7호
    • /
    • pp.1141-1148
    • /
    • 2017
  • Generally, a thermistor made by sintering a metal oxide is widely used to measure the ambient temperature. This thermistor is widely used not only for industrial use but also for medical use because of its excellent sensitivity, durability, temperature change characteristics and low cost. In particular, the normal body temperature is 36.9 degrees relative to the armpit temperature, and it is most closely related to the circulating blood flow. Previous studies have shown that body temperature changes during biomechanical changes and body temperature changes by anomalous signs or illnesses. Therefore, in this study, we propose a Lock-In-Amp design to detect minute temperature changes of clothing and thermistor wired by a preacher as a method to regularly measure body temperature in daily life. Especially, it is designed to measure the minute resistance change of the thermistor according to body temperature change even in a low-cost microprocessor environment by using a micro-processor-based Lock-In-Amp, and a jacquard and the thermistor is arranged so as to be close to the side, so that the reference body temperature can be easily measured. The temperature was measured and stored in real time using short-range wireless communication for non - restraint temperature monitoring. A baby vest was made to verify its performance through temperature experiments for infants. The measurement of infant body temperature through the existing skin sensor or thermometer has limitations in monitoring infant body temperature for a long time without restriction. However, it can be overcome by using the embroidery fabric based micro temperature monitoring wireless monitoring device proposed in this study.

지하매설 가스관의 부식 및 결함 탐지를 위한 비파괴 누설 탐상시스템 개발에 관한 연구 (Research on MFL PIG Design for caustic and defect the Inspection of Underground Gas Pipeline)

  • 박상호;박관수
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 춘계합동학술대회 논문집
    • /
    • pp.11-20
    • /
    • 2002
  • 본 논문에서는 3차원 형태의 결함을 가진 지하매설 가스관에서 누설자속(magnetic flux leakage, MFL) 탐상법을 사용한 결함 검출에 관하여 연구하였다. 영구자석과 요크로 구성된 자기 시스템을 유한요소법을 사용하여 해석하고 동작점을 설정하였다. 가스관이 충분히 포화되지 않은 경우에는 측정이 곤란하며, 과대포화된 경우에는 결함에 의한 누설자속의 변화량이 적어서 측정이 곤란하므로 적정한 값을 설정하여야 하므로 자기 시스템의 동작점은 결합이 있을 때 누설자속 증가율이 최대가 되도록 설정하여야 한다. 본 논문에서는 3차원 비선형 유한요소법을 사용하여, 가스관에 결함이 있는 경우 결함의 크기, 깊이에 따른 결함신호를 예측하여 그 결과 가스관 포화상태의 적절여부, 홀 센서 range 및 resolution의 적정도 등을 연구하였다. 또한 홀 센서의 민감도 향상을 위하여 back-yoke를 사용하여 측정신호를 향상시키는 방법을 제안하였다.

  • PDF