• 제목/요약/키워드: Self-Corrosion

Search Result 112, Processing Time 0.024 seconds

Self-healing Coatings for an Anti-corrosion Barrier in Damaged Parts

  • Cho, Soo Hyoun
    • Corrosion Science and Technology
    • /
    • v.8 no.6
    • /
    • pp.223-226
    • /
    • 2009
  • Polymer coatings are commonly applied to metal substrates to prevent corrosion in aggressive environments such as high humidity and under salt water. Once the polymer coating has been breached, for example due to cracking or scratches, it loses its effectiveness, and corrosion can rapidly propagate across the substrate. The self-healing system we will describe prevents corrosion by healing the damage through a healing reaction triggered by the actual damage event. This self-healing coating solution can be easily applied to most substrate materials, and our dual-capsule healing system provides a general approach to be compatible with most common polymer matrices. Specifically, we expect an excellent anti-corrosion property of the self-healing coatings in damaged parts coated on galvanized metal substrates.

A Study on Anti-Corrosion Effect of Powder Self Water Proof Admixture Mixed Corrosion Inhibitor for Reinforcing Steel (철근부식억제형 구체방수재의 방청효과에 관한 연구)

  • 신도철;손형호;김원화
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.10a
    • /
    • pp.409-414
    • /
    • 2002
  • This study is intended to develop the self water proof admixture for durability concrete by anti-corrosion inhibitor. Chloride induced corrosion of reinforcement is one of the main factor which cause the deterioration of concrete structure. When the substitute anti-corrosion agents for a part of self waterproofing agent, the corrosion-proof increases for the increased water proofing capacity. And proper self waterproofing agent by cement weight in concrete was generally positive effect to concrete compressive strength, slump, freezing and thawing resistance. Also, permeability and absorption show a straight decrease when self waterproofing agent is added.

  • PDF

A Basic Study on the Self-Corrosion Inhibition Function Identification of VA/E/MMA-Modified Mortar with Nitrite-Type Hydrocalumite (칼루마이트 및 VA/E/MMA 분말수지 병용 PMM의 자기방청기능 규명을 위한 기초적 연구)

  • Hong, Sun-Hee;Kim, Wan-Ki
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.11a
    • /
    • pp.253-254
    • /
    • 2011
  • The purpose of this study is to investigate chloride ion adsoption property of cement mortar using nitrite type hydrocalumite(calumite) with self-corrosion inhibition function. Superior corrosion inhibition function of the VA/E/MMA-modified mortars with calumite was ascertained from accelerated corrosion test in the previous study. In this study, VA/E/MMA-modified mortars with calumite were prepared with calumite contents of 0, 5, 10% and polymer-binder ratio of 0, 10%, and tested for chloride ion adsorption to make it clear how calumite gives self-corrosion inhibition function to cement mortar. As a result, chloride ion adsorption property of VA/E/MMA-modified mortars with calumite was improved by increasing calumite contents compared to unmodified mortar regardless of using VA/E/MMA terpolymer powder or not.

  • PDF

Critical Influence of Rivet Head Height on Corrosion Performance of CFRP/Aluminum Self-Piercing Riveted Joints

  • Karim, Md Abdul;Bae, Jin-Hee;Kam, Dong-Hyuck;Kim, Cheolhee;Park, Yeong-Do
    • Corrosion Science and Technology
    • /
    • v.18 no.3
    • /
    • pp.92-101
    • /
    • 2019
  • This study investigates how rivet head height affects the corrosion performance of carbon fiber reinforced plastic (CFRP) to aluminum alloy self-piercing riveted joints. Specimens with two different head heights were prepared. A rivet head protruding out of the top CFRP laminate forms the proud head height while a rivet head penetrating into the top CFRP generates the flush head height. The salt spray test evaluated corrosion performance. The flush head joints suffered from severe corrosion on the rivet head. Thus, the tensile shear load of flush head joints was substantially reduced. Electrochemical corrosion tests investigated the corrosion mechanisms. The deeper indentation of the flush head height damaged the CFRP around the rivet head. The exposure of damaged fibers from the matrix increased the cathodic potential of local CFRP. The increased potential of damaged CFRP accelerated the galvanic corrosion of the rivet head. After the rivet head coating material corroded, a strong galvanic couple was formed between the rivet head base metal (boron steel) and the damaged CFRP, further accelerating the flush rivet head corrosion. The results of this study suggest that rivet head flushness should be avoided to enhance the corrosion performance of CFRP to aluminum alloy self-piercing riveted joints.

Self-Corrosion Protection of Polymer Cementitious Materials Using Terpolymer Powders with a Nitrite-type Hydrocalumite (아질산형 hydrocalumite와 터폴리머 분말수지를 병용한 폴리머 시멘트계 재료의 자기방청기능)

  • Hong, Sun-Hee;Kim, Wan-Ki
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2010.05a
    • /
    • pp.73-76
    • /
    • 2010
  • This study deals with the properties of polymer-modified mortars with a nitrite-type hydrocalumite, which are effectively used as intelligent patch materials for deteriorated reinforced concrete structures. The calumite is a material that can adsorb the chloride ions (Cl-) causing the corrosion of reinforcing bars and liberate the nitrite ions (NO2-) inhibiting the corrosion in reinforced concrete, and can provide a self-corrosion inhibition function to the reinforced concrete. Polymer-modified mortars using hydrocalumite and terpolymer powders are prepared with various calumite contents and polymer-binder ratios, and tested for corrosion inhibition. Subsequently, regardless of the polymer-binder ratio, the replacement of ordinary portland cement with the calumite has a marked effect on the corrosion-inhibiting property of the polymer-modified mortars.

  • PDF

Effect of Bacteria on the Rebar Corrosion (철근 부식에 자기치유 박테리아가 미치는 영향)

  • Jang, Indong;Park, Jiyoon;Son, Dasom;Yi, Chongku
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.221-222
    • /
    • 2021
  • Bacterial self-healing concrete is known to improve the durability of concrete by preventing the propagation of microcracks. In the literature, bacteria prevent the corrosion of rebar by inhibiting water transfer through crack, but also can promote the corrosion by acting as an ion acceptor in the rust generation mechanism. Therefore in this study, the electrochemical analysis of bio-filmed rebar was conducted to explore the effects of the self-healing bacteria on the bare rebar without cement composite. As a result of the experiment contradicting trends for Ecorr and Icorr occurred and additional experiment will be conducted in various environments to collect data on the mechanism of corrosion of rebar by bacteria.

  • PDF

Effect of Fusing Treatment on Anti-Corrosion Characteristics of Ni-based Self-flux Alloy Coating (니켈기 자융성 합금 코팅의 방식특성에 미치는 후열처리의 영향)

  • Kim, Tae-Yong;Kim, Jae-Dong;Kim, Yeong-Sik
    • Journal of Power System Engineering
    • /
    • v.17 no.4
    • /
    • pp.79-85
    • /
    • 2013
  • This study aims at investigating the effect of a fusing treatments on anti-corrosion characteristics of Ni-based self-flux alloy coating. Ni-based coatings were fabricated by flame spray process on steel substrates, and fusing treatments were performed using a vacuum furnace at $800^{\circ}C$ $900^{\circ}C$, $1000^{\circ}C$ and $1100^{\circ}C$. After fusing treatments, corrosion tests were carried out using potentiostat/galvanostat at solution with pH 2 and pH 6. Corrosion potential(Ecorr) and corrosion current density(Icorr) could be analyzed from polarization curve. Fusing-treated coating at $1100^{\circ}C$ showed more favorable anti-corrosion characteristics than as-sprayed coating. Anticorrosive effect of fusing-treated coating at solution with pH 2 was relatively greater than at solution with pH 6. Fusing-treated coating at $1100^{\circ}C$ showed the most excellent anti-corrosion characteristics.

Polarization Characteristics of Heat-treated Ni-based Self-flux Alloy Coating in Alkaline Solution (후열처리한 니켈기 자융성 합금 코팅의 알칼리 용액에서의 분극특성)

  • Kim, Tea-Yong;Kim, Jea-Dong;Kim, Yeong-Sik
    • Journal of Power System Engineering
    • /
    • v.18 no.2
    • /
    • pp.37-42
    • /
    • 2014
  • The purpose of this paper is to investigate polarization characteristics of heat-treated Ni-based self-flux alloy coating in alkaline solution. Ni-based self-flux alloy powder was sprayed to a steel substrate using flame spray process, and heat treatments were performed in a vacuum furnace at $800^{\circ}C$, $900^{\circ}C$, $1000^{\circ}C$ and $1100^{\circ}C$. After heat treatments, corrosion tests were carried out using potentiostat/galvanostat at solution with pH 8 and pH 13. Corrosion potential(Ecorr) and corrosion current density(Icorr) could be analyzed from polarization curve. Anticorrosive effect of heat-treated coating at solution with pH 8 was relatively greater than at solution with pH 13. Heat-treated coating at $1100^{\circ}C$ showed the greatest anti-corrosion characteristics in alkaline solution.

Evaluation of Corrosion Resistance Properties by Applying Galvanostatic Nanoscale Current Density on Passive Metals

  • Na, Seung-Chan;Lee, Jeong-Ja;Yang, Won-Seog;Hwang, Woon-Suk
    • Corrosion Science and Technology
    • /
    • v.6 no.1
    • /
    • pp.7-11
    • /
    • 2007
  • In this study, new evaluation method for the stability and corrosion resistance properties of passive films has been suggested by means of observation of self-activation process in open-circuit state and galvanostatic nanoscale reduction test. The experiments were performed for air-formed oxide film in case of plain carbon steel, and for anodically passivated films formed in aqueous sulfuric acid solutions in case of titanium and 304 stainless steel. From these experimental results, we derived two parameters, $i_{0}$ and $q_{0}$, which characterize the self-activation process and the properties of passive film on a stainless steel surface. The parameter $i_{0}$ was defined as the rate of self-activation, and $q_{0}$, the reduced amount of charge during the self-activation process. In conclusion, it is considered that the stability and corrosion resistance of passive metals and alloys can be evaluated quantitatively by three parameters of $\tau_{0}$, $q_{0}$, and $i_{0}$, which easily obtain by means of observing the self-activation process and galvanostatic nanoscale reduction test.

Improvement of Corrosion Resistance for Copper Tube by Electrochemical Passivation (전기화학적 부동태화에 의한 동관의 내식성 개선 연구)

  • Min, Sung-Ki;Kim, Kyung-Tae;Hwang, Woon-Suk
    • Corrosion Science and Technology
    • /
    • v.10 no.4
    • /
    • pp.125-130
    • /
    • 2011
  • This study was performed to improve the corrosion resistance and the stability of passive film on copper tube by potentiostatic polarization method in synthetic tap water. Formation of passive film was carried out by anodic potentiostatic polarization at various passivation potentials and passivation times in 0.1 M NaOH solution. Stability of passive film and corrosion resistance was evaluated by self-activation time, ${\tau}_0$ from passive state to active state on open-circuit state in 0.1 M NaOH solution. Addition of polyphosphate in NaOH solution prolonged the self-activation time and improved the corrosion resistance, and the addition of 5 ppm polyphosphate was most effective. It was also observed that better corrosion resistance was obtained by potentiostatic polarization at 1.0 V (vs. SCE) than at any other passivation potentials. Passivated copper tube showed perfect corrosion resistance for the immersion test in synthetic tap water showing that the anodic potentiostatic polarization treatment in 0.1 M NaOH with 5 ppm polyphosphate solution would be effective in improving the corrosion resistance and preventing the blue water problem.