• 제목/요약/키워드: Rubbed Surface

검색결과 141건 처리시간 0.022초

러빙 처리된 표면의 적층 절연막을 가지는 Pentacene TFT의 전기적 특성 (ELECTRICAL CHARACTERISTICS OF PENTACENE THIN FILM TRANSISTORS WITH STACKED AND SURFACE-TREATED GATE INSULATORS)

  • 강창헌;이종혁;박재훈;최종선
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1546-1548
    • /
    • 2002
  • In this paper, the electrical characteristics of pentacene thin film transistors(TFTs) with stacked and surface-treated gate insulators have been investigated. The semiconductor layer of pentacene was thermally evaporated onto the stacked gate insulators. For the gate insulating materials. PVP(PolyvinylPhenol) and polystyrene were spin-coated with two different stacking orders, PVP-polystyrene and polystyrene-PVP. Rapid solvent evaporation during the spin-coating processes of these insulating layers produces non-equilibrium phase morphologies accompanied by surface undulations on gate insulator interfaces. This non-equilibrium phase morphology affects the growth mode of the subsequent pentacene layer. Therefore, in order to smoothen the gate dielectric surfaces, gate dielectric surfaces were rubbed laterally along the direction from the drain to the source TFTs with with stacked and surface-treated gate insulators have provided improved operational characteristics.

  • PDF

염산 테트라싸이클린이 RBM적용 임프란트 표면구조에 미치는 영향의 미세구조 및 표면 거칠기 변화에 관한 연구 (The effect of conditioning by Tetracycline-Hcl on implant surface;The SEM study and. surface roughness measurements : RBM surface)

  • 임해수;박준봉;권영혁;허익;정종혁
    • Journal of Periodontal and Implant Science
    • /
    • 제37권3호
    • /
    • pp.585-597
    • /
    • 2007
  • The present study was performed to evaluate the effect of Tetracycline-HCI and Saline on the change of implant surface microstructure and surface roughness according to application time. Implants with resorbable blasting media surface were utilized. Before test all 13 implants were measured surface roughness. Among them, 6 implants were rubbed with 50mg/ml Tetracycline-HCl solution and other 6 implants with saline for $\frac{1}{2}$min., 1min., $1\frac{1}{2}$min., 2min., $2\frac{1}{2}$min and 3min. Then, specimens were processed for scanning electron microscopic observation and surface roughness after test. The results of this study were as follows. 1. Control group showed a few irregular, rough, uneven surface with crater-like depression. 2. The test group with Tetracycline-HCl conditioning showed an altered surface when Tetracycline-HCl was applied for 30secs, and showed a various surface alteration as application times go on. 3. The test group with Saline conditioning showed no significant surface differences and surface roughness. 4. The significant increase of Ra value was showed when Tetracycline-HCl was applied for 30secs. In conclusion, the 50mg/ml Tetracycline-HCl must not be applied for the RBM surface implant for surface treatment.

지의류 복합체에 의한 매실나무 지의류병 (Lichen Diseases on Prunus mume Caused by Colonization of Consortium of Several Crustose Lichens Including Parmotrema autrosinense)

  • 고영진;김경희;정인호;임명택;박현수;이규산;조경연;허재선
    • 식물병연구
    • /
    • 제13권3호
    • /
    • pp.223-227
    • /
    • 2007
  • 지의류는 곰팡이와 광합성을 하는 조류 또는 남조류의 공생체로서 토양, 바위, 나무 등에 아주 널리 분포하는 진핵생명체다. 지의류형성곰팡이는 흔히 죽은 나무나 죽어가는 나무 위에서 부착하여 증식하지만 나무를 직접적으로 죽이지는 않는다. 전남 순천시 매실나무 과수원 포장에 있는 매실나무 수피에 엽상체 지의류 Parmotrema autrosinense를 포함한 몇 가지 가상체 지의류가 심하게 증식하고 있었다. 이러한 지의류 조합의 증식으로 매실나무는 회색으로 흉하게 보이고 정상적인 생장이 억제되었으며, 심각하게 영향을 받은 매실나무 가지의 수피에서 지의체를 제거하지 않으면 낙엽이 지고 가지가 말라 죽었다. 매실나무 수피에 있는 지의체를 제거해주면 매실나무 가지들은 수세를 회복하였으며, 지의체를 제거한 후에 $Twin^{(R)}$ 20 또는 톱신페스트를 발라주면 더욱 수세가 왕성해졌다. 따라서 매실나무에 몇 가지 지의류 조합의 정착 및 증식에 의해 발생하는 낙엽과 가지마름 증상을 '매실나무 지의류병(lichen disease)'이라고 명명할 것을 제안한다.

염산테트라싸이클린 적용시간에 따른 GBA 및 RBM 임프란트 표면변화 (The Micromorphometric change of the GBA and RBM implant surface conditioned with tetracycline-HCI)

  • 박강훈;허익;권영혁;박준봉;정종혁
    • Journal of Periodontal and Implant Science
    • /
    • 제36권3호
    • /
    • pp.705-716
    • /
    • 2006
  • The present study was performed to evaluate the effect of tetracycline-HCl on the change of implant surface microstructure according to application time. Implant with pure titanium machined surface, GBA surface and RBM surface were utilized. Implant surface was rubbed with 50mg/ml tetracycline-HCl solution for ${\frac{1}{2}}$min. 1min. $1{\frac{1}{2}}$min. 2min. and $2{\frac{1}{2}}$min. respectively in the test group. Then, specimens were processed for scanning electron microscopic observation. The results of this study were as follow. 1. Both test and control group showed a few shallow grooves and ridges in pure titanium machined surface implants. There were not significant differences between two group. 2. In GBA surfaces, control group exhibit many porous depression, and each depression were divided by strict border. Experimental group applied with tetracycline-HCl for 2min. were similar with control group. But when applied for $2{\frac{1}{2}}$min. surface alteration and border breakdown started, resulting enlargement of the porous depression. 3. In REM surface, control group exhibit rough, uneven surface with crater-like depression can be found. The surface alteration started when tetracycline-HCl was applied for 30sec. resulting breakdown of the crater-like depression. Depression became larger as applying time increased.

산화 티타늄 블라스팅 임프란트 표면구조에 대한 염산 테트라싸이클린의 영향 (Micromorphometric change of Ti$O_2$ blast implant surface conditioned with tetracycline-HCI)

  • 이정민;허익;권영혁;박준봉;정종혁;허성주
    • Journal of Periodontal and Implant Science
    • /
    • 제37권3호
    • /
    • pp.599-611
    • /
    • 2007
  • The present study was performed to evaluate the surface roughness and effect of Tetracycline-HCI on the change of implant surface microstructure according to application time. Ti$O_2$ surface Implant was utilized. Implant surface was rubbed with 50mg/ml Tetracycline-HCI solution for 0.5min, 1min, 1.5min, 2min, 2.5min and 3min respectively in the Tetracycline-HCI group. Then, specimens were measured surface roughness and processed for scanning electron microscopic observation. The results of this study were as follows. 1. Ti$O_2$ blast implant surface showed increased surface roughness 1.5 minute after treatment with Tetracycline-HCI. But, there were not significant differences in saline group after treatment. 2. Tetracycline-HCI group showed changed surface micro-morphology in SEM after 1.5 minute. There were not significant differences in saline group after treatment. 3. Between Tetracycline-HCI group and saline group, there were difference in surface roughness change and SEM micro-morphology. Tetracycline-HCI have influence on Ti$O_2$ blast implant surface. In conclusion, the detoxification with 50mg/ml Tetracycline-HCI must be applied respectively with different time according to various implant surfaces.

구연산의 적용시간에 따른 임플란트 표면변화에 대한 주사전자현미경적 연구 (Scanning Electron Microscopic Study of the Effects of Citric Acid on the Change of Implant Surface According to Application Time)

  • 송우석;권영혁;이만섭;박준봉;허익
    • Journal of Periodontal and Implant Science
    • /
    • 제32권4호
    • /
    • pp.697-709
    • /
    • 2002
  • The present study was performed to evaluate the effect of citric acid on the change of implant surface microstructure according to application time. Implants with pure titanium machined surface, titanium plasma-sprayed surface, and sand-blasted, large grit, acid etched surface were utilized. Implant surface was rubbed with pH 1 citric acid for $\frac{1}{2}$ min., 1 min., 1 $\frac{1}{2}$ min., 2 min., and 3min, respeaively in the test group and implant surface was not treated in the control group. Then, the specimens were processed for scanning electron microscopic observation. The following results were obtained. 1. Both test and control group showed a few shallow grooves and ridges in pure titanium machined surface implants. There were not significant differences between two groups. 2. In titanium plasma-sprayed surfaces, round or amorphous particles were deposited irregularly. The irregularity of titanium plasma-sprayed surfaces conditioned with pH 1 citric acid was lessened and the cracks were increased relative to the application time of pH 1 citric acid. 3. Sand-blasted, large grit, acid etched surfaces showed the macro/micro double roughness. The application of pH 1 citric acid didn't change the characteristics of the sand-blasted, large grit, acid etched surfaces. In conclusion, the application of pH 1 citric acid to titanium plasma-sprayed surface is improper. And pure titanium machined surface implants and sand-blasted, large grit, acid etched surface implants can he treated with pH 1 citric acid for peri-implantitis treatment if the detoxification of these surfaces could be evaluated.

표면처리 시간에 따른 임프란트 미세구조의 변화 : $FBR^{(R)}$과 CellNest 표면 임프란트 (Micromorphometric change of implant surface conditioned with tetracycline-HCI : $FBR^{(R)}$ and CeliNest surface)

  • 창동욱;박준봉;권영혁;허익;정종혁
    • Journal of Periodontal and Implant Science
    • /
    • 제36권3호
    • /
    • pp.717-729
    • /
    • 2006
  • The present study was performed to evaluate the effect of tetracycline-BCL on the change of implant surface microstructure according to application time. Implant with pure titanium machined surface, double coated $FBR^{(R)}$ surface and oxidized CellNest surface were utilized. Implant surface was rubbed with $50mg/m{\ell}$ tetracycline-BCL solution for ${\frac{1}{2}}$, 1, $1{\frac{1}{2}}$, 2 and $2{\frac{1}{2}}$min. respectively in the test group. Then, specimens were processed for scanning electron microscopic observation. The results of this study were as follows. 1. Both test and control group showed a few shallow grooves and ridges in pure titanium machined surface implants. There were not significant differences between two groups. 2. The double coated $FBR^{(R)}$ surfaces showed fine crystalline structures. The roughness of surfaces conditioned with tetracycline-BCL was lessened relative to the application time. 3. The oxidized CellNest surfaces showed the porous structures. The surface conditioning with tetracycline-BCI influenced on its micro-morphology. In conclusion, the detoxification of the affected implant surface with $50mg/m{\ell}$ tetracycline-BCL should be applied respectively with different time according to various implant surfaces.

구연산 HA임플란트 표면구조에 미치는 영향 (The Effects of Citric Acid on HA coated Implant Surface)

  • 김중천;권영혁;박준봉;허익;정종혁;신승일
    • Journal of Periodontal and Implant Science
    • /
    • 제37권3호
    • /
    • pp.575-584
    • /
    • 2007
  • The present study was performed to evaluate the effect of citric acid on the change of implant surface microstructure according to application time. Implants with pure titanium machined surface, and HA coated surface were utilized. Pure titanium machined surface and HA coated surface were rubbed with pH 1 citric acid for 30s., 45s., 60s., 90s., and 120s. respectively. Then, the specimens were processed for scanning electron microscopic observation. The following results were obtained. 1. The specimens showed a few shallow grooves and ridges in pure titanium machined surface implants. The roughness of surfaces conditioned with pH 1 citric acid was slightly increased. 2. In HA-coated surfaces, round particles were deposited irregularly. The specimens were not significant differences within 45s. But, began to be changed from 60s. The roughness of surfaces was lessened and the surface dissolution was increased relative to the application time. In conclusion, pure titanium machined surface implants and HA coated surface implants can be treated with pH 1 citric acid for peri-implantitis treatment if the detoxification of these surfaces could be evaluated.

염산테트라싸이클린의 적용시간에 따른 특수 가공된 임프란트 표면 변화 (Micromorphometric change of implant surface conditioned with Tetracycline-HCl : HA and Etched surface)

  • 한주영;박준봉;권영혁;허익;정종혁
    • Journal of Periodontal and Implant Science
    • /
    • 제36권3호
    • /
    • pp.731-744
    • /
    • 2006
  • The present study was performed to evaluate the effect of tetracycline-HCl on the change of implant surface microstructure according to application time. Implant with pure titanium machined surface, HA-coated surface and dual acid etched surface were utilized. Implant surface was rubbed with $50mg/m{\ell}$ tetracycline-HCL solution for ${\frac{1}{2}}$min., 1min., $1{\frac{1}{2}}$min., 2min., and $2{\frac{1}{2}}$min. respectively in the test group. Then, specimens were processed for scanning electron microscopic observation. The results of this study were as follows. 1. Both test and control group showed a few shallow grooves and ridges in pure titanium machined surface implants. There were not significant differences between two groups. 2. In HA-coated surfaces, round particles were deposited irregularly. The roughness of surfaces conditioned with tetracycline-HCL was lessened and the cracks were increased relative to the application time. 3. The etched surfaces showed the honey comb structures. The surface conditioning with tetracycline-HCI didn't influence on its micro-morphology. In conclusion, the detoxification with $50mg/m{\ell}$ tetracycline-HCI must be applied respectively with different time according to various implant surfaces.

염산 테트라싸이클린이 SLA 임플란트의 표면 구조에 미치는 영향 (The effects of tetracycline-HCI on SLA implant surface structure)

  • 서미란;권영혁;박준봉;허익;정종혁
    • Journal of Periodontal and Implant Science
    • /
    • 제37권2호
    • /
    • pp.251-263
    • /
    • 2007
  • The present study was performed to evaluate the effects of Tetracycline-HCI on the microstructure change of SLA implant surface according to application time. In the Tetracycline-HCI group, 6 implants were rubbed with sponges soaked $50mg/m{\ell}$ Tetracycline-HCI solution for O.5min., lmin., 1. 5min., 2min., 2.5min. and 3min. In the saline group. another 6 implants conditioned with sponges soaked saline using same methods. One implant wasn't conditioned anything. Then, the changes of surface roughness values were evaluated by optical interferometer & specimens were processed for scanning electron microscopic observation. The results of this study were as follows: 1. In both Tetracycline-HCI group & saline group, there are no significant differences between surface roughness values before & after surface detoxification. And in scanning electron microscopic observation. there are slightly changes of implant surface structures but this changes were not significant by comparison with no treatment implant surface. 2. In the changes of surface roughness values & the scanning electron microscopic observation, there were no significant differences between saline & Tetracycline-HCI groups. In conclusion, the detoxification with $50mg/m{\ell}$ Tetracycline-HCI within 3 minutes can be applied for treatment of peri-implantitis in SLA surface implants. without surface microstructure changes.