• Title/Summary/Keyword: Radiologic Science

Search Result 479, Processing Time 0.025 seconds

Study on the Effect of Smart Learning applied at a Radiationtherapy Subject on Self Directed Learning, Self Learning Efficacy, Learning Satisfaction of College Students (방사선과 학생의 스마트 학습법 적용이 자기 주도적 학습능력, 학업적 자기 효능감, 학습 만족도에 미치는 영향)

  • Shim, Jae-Goo;Kim, Yon-Min;Park, Soo-Jin
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.661-667
    • /
    • 2016
  • The purpose of this was to study and analyze smart learning the self directed learning, self efficacy, learning satisfaction about department of radiology in a college. For this study total students 102 in 3 classes were surveyed at the end of semester. The research data was analyzed using SPSS also self directed learning, self learning efficacy, learning satisfaction analyzed t-test, ANOVA and Pearson's correlation coefficient results were followings. First, Men is more higher than women in a self learning efficacy, self directed learning, learning satisfaction. Second, in a learning satisfaction smart learning ever heard in a first time group more satisfaction. Third, during the smart learning classes a students appeared a positive response. As a results, learning satisfaction will increase a learning when learners need a ability of self control planning and learning motivation by themselves in voluntarily and actively. Suggest to change a paradigm in a radiology classes so we have to improve a teaching skills this solution recommend is two way communication. In conclusion, smart learning applied for classes of college is meaningful as a new teaching, which can be change gradually learning satisfaction by teaching methods.

A Study of Spinal Curvature in Female and Male University Students (남녀 대학생의 척추만곡에 관한 연구)

  • Lee, Byung-Kyu;Nam, Ki-Seok;Yi, Chung-Hwi
    • Physical Therapy Korea
    • /
    • v.5 no.3
    • /
    • pp.72-87
    • /
    • 1998
  • This study examined the rates of spinal abnormal curvature and the correlation of the Body Mass Index (BMI), Low Back Pain (LBP) and spinal curvature by measuring scoliosis, kyphosis, and lordosis in university students. The study population included 67 male, 92 female university students, making a total of 159, in Wonju City. Spinal curvature was measured by an electrogoniometer in a computerized skeletal analysis system. Lateral curvature of spine of more than 10 degrees was considered as nonspostural scoliosis. The correlation of BMI, LBP and the spinal curvature was analysed by Pearson's correlation coefficient and t-test. The following results were obtained: 1. The overall incidence and rate of scoliosis in cases with a greater than 10 degree curve in males was an incidence of 8 and a rate of 11%. In females the incidence was 36 and the rate 39.2%. 2. The overall incidence and rate of kyphosis of less than 20 degrees in males was a rate of 9 and an incidence of 11.9%. In females, the rate was 5 and the incidence 5.4%. In kyphosis cases of more than 40 degrees, the male rate was 5 and the incidence 7.7%. For female the rate was 13 and the incidence 14.2%. 3. The overall incidence and rate of lordosis with curves of less than 20 degrees was a rate of 6 for males and an incidence of 9.0%. For females, the rate was 5 and the incidence 5.4%. In cases of more than 50 degrees lordosis, the female rate was 2 and the incidence 2.2%. There were no males in this category. 4. There was a negative correlation between kyphosis and BMI. The greater the kyphotic curve, the less the BMI in males (p<0.05). There was no significant BMI difference by gender in either scoliosis or lordosis. There was, however, a significantly decreased sacral angle in the female group with LBP. The results of this study cannot be generalized to the general population because the subjects were all from one university. The measurements were quite reliable because the angles determined by the Metrocom System were highly correlated with radiologic findings. This study shows the need for a regular screening system for spinal curvatures in university health examination procedures.

  • PDF

A Phantom Study for the Optimal Low-dose Protocol in Chest Computed Tomography Examination (흉부 전산화단층촬영검사를 위한 최적의 저선량 프로토콜에 관한 팬텀연구)

  • Kim, Young-Keun;Yang, Sook;Wang, Tae-uk;Kim, Eun-Hye
    • Journal of radiological science and technology
    • /
    • v.44 no.2
    • /
    • pp.101-107
    • /
    • 2021
  • The purpose of this study was to evaluate optimal CT scan parameters to minimize patient dose to the irradiation and maintain satisfactory image quality in low-dose chest computed tomography (CT) scans. In a chest anthropomorphic phantom, chest CT scans were performed at different kVp and mA within reference of 3.4mGy in volume CT Dose Index (CTDIvol). The following quantitative parameters had been statistically evaluated: image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and figure of merit (FOM). Nine radiographers conducted the blind test to select the optimal kVp-mA combination. Results indicated that the kVp-mA combination of 80kVp-90mA, 100kVp-50mA, 120kVp-30mA and 140kVp-30mA were obtained high SNR and CNR. The 120kVp-30mA combination offered good compromise in the FOM, which showed the quality and dose performance. In the blind test, an image of 80kVp-90mA obtained a high score with 4.7 points, and 120kVp-10mA or 140kVp-10mA with a low tube current were observed severe noise and poor image quality, thus resulting in decreased diagnostic accuracy. On the other hand, in the combination of high kVp and high mA(140kVp-90mA), the image quality was improved, but the radiation dose was also increased. the FOM value of 140kVp-90mA was lower than 120kVp-30mA. The application of appropriate scan parameters in low-dose chest CT scans produced satisfactory results in dose and image quality for the accuracy of the clinical diagnosis.

A Study on MR Imaging Method for The Patient with Inserting Shoulder Joint Suture Anchor (견관절 삽입술을 시행한 환자의 자기 공명 영상법에 관한 연구)

  • Park, Eui-Cheol;Bae, Seok-Hwan;Ryu, Yeun-Chul;Park, Young-Joon;Kim, Yong-Gwon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.4
    • /
    • pp.513-519
    • /
    • 2021
  • Metallic suture anchors are very useful and common fixation devices that are inserted into the target bone to sustain the tendon of a patient with musculus supraspinatus tendon ruptures. On the other hand, the presence of a metallic material prosthesis, such as a metal suture anchor, causes severe MR imaging artifacts, including field distortion, signal loss, and failure of fat suppression. The difference in magnetic susceptibility between metal and other organic materials causes magnetic field distortion surrounding the prosthesis. The resulting magnetic field inhomogeneity makes the images with a lower signal-to-noise ratio and distortion. For a patient with a suture anchor implanted, MR imaging is the golden standard for determining the postoperative prognosis, and a fat-saturation sequence is one of the imaging methods most affected by metal-induced artifacts. In this study, three fat-saturation sequences were compared. Artifact quantification and contrast comparison between the supraspinatus tendon and the surrounding muscle were presented. The images obtained using the STIR pulse sequence showed fewer susceptibility artifacts and better visibility in the supraspinatus tendon and the tissue area. Therefore, the STIR sequence is the most appropriate fat-saturation imaging method for patients with a metallic prosthesis.

The Effect of MLC Leaf Motion Constraints on Plan Quality and Delivery Accuracy in VMAT (체적조절호형방사선치료 시 갠트리 회전과 다엽콜리메이터의 이동 속도에 따른 선량분포 평가)

  • Kim, Yon-Lae;Chung, Jin-Beom;Lee, Jeong-woo;Shin, Young-Joo;Kang, Dong-Jin;Jung, Jae-Yong
    • Journal of radiological science and technology
    • /
    • v.42 no.3
    • /
    • pp.217-222
    • /
    • 2019
  • The purpose of this study is to evaluate the dose distribution by gantry rotation and MLC moving speed on treatment planning system(TPS) and linear accelerator. The dose analyzer phantom(Delta 4) was scanned by CT simulator for treatment planning. The planning target volumes(PTVs) of prostate and pancreas was prescribed 6,500 cGy, 5,000 cGy on VMAT(Volumetric Modulated Arc Therapy) by TPS while MLC speed changed. The analyzer phantom was irradiated linear accelerator using by planned parameters. Dose distribution of PTVs were evaluated by the homogeneity index, conformity index, dose volume histogram of organ at risk(rectum, bladder, spinal cord, kidney). And irradiated dose analysis were evaluated dose distribution and conformity by gamma index. The PTV dose of pancreas was 4,993 cGy during 0.1 cm/deg leaf and gantry that was the most closest prescribed dose(5,000 cGy). The dose of spinal cord, left kidney, and right kidney were accessed the lowest during 0.1 cm/deg, 1.5 cm/deg, 0.3 cm/deg. The PTV dose of prostate was 6,466 cGy during 0.1 cm/deg leaf and gantry that was the most closest prescribed dose(6,500 cGy). The dose of bladder and rectum were accessed the lowest during 0.3 cm/deg, 2.0 cm/deg. For gamma index, pancreas and prostate were analyzed the lowest error 100% at 0.8, 1.0 cm/deg and 99.6% at 0.3, 0.5 cm/deg. We should used the optimal leaf speed according to the gantry rotation if the treatment cases are performed VMAT.

A Study on the Exposure Dose of Workers and Frequent Workers in the Radiology Department (방사선(학)과의 작업종사자와 수시출입자의 교내 실습에 따른 피폭선량에 대한 고찰)

  • Jeon, Seong-Min;Lee, Yong-Ki;Ahn, Sung-Min
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.3
    • /
    • pp.355-359
    • /
    • 2021
  • In this study, the purpose of this study was to analyze the degree of exposure of radiation workers assigned to the Department of Radiology and frequent visitors during on-campus practice, and to conduct a basic study on the feasibility and optimization of the radiation protection of the Nuclear Safety Act for the Department of Radiology. . The average exposure dose of occupational workers by year was 0.01 mSv, the lowest in 2014 and 2016. The highest figure was 0.12 mSv in 2018. The average exposure dose of frequent visitors by year was the lowest at 0.013 mSv in 2018, and the highest at 0.022 mSv in 2016. According to this study, the annual exposure dose received by professors, practical assistants, and students in the department of radiology (department) who use only radiation generators in the course of in-school practice is less than 1 mSv, which is the dose limit for the general public. Therefore, at the time when the radiation dose of students in the Department of Radiology is lower than the dose limit of the general public, the current safety regulation of the Nuclear Safety law is judged to be excessive regulation. Therefore, it is considered necessary to revise the regulations for radiation generators in the current Nuclear Safety law or to revise the radiation safety management system for university students.

Development and Application of Case-Based Learning Program for Occupational Personality Education of Health Care Worker (보건의료종사자 맞춤형 직업인성교육을 위한 사례기반학습 프로그램 개발 및 적용)

  • Yang, Eun Ju;Kim, Hye Ran;Chang, Jeong Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.3
    • /
    • pp.371-379
    • /
    • 2021
  • The personality education of the existing university is mainly focused on occupational ethics education or basic education, but the purpose and method of the personality education program is changed in preparation for the 4th industry and the related occupational personality education program is needed. In Korea, however, there is a lack of research on the development of educational programs for occupational personalities that Health care workers should have. Therefore, this study aims to confirm the effect by developing and applying a program for occupational personality education for Health care workers required for the 4th Industrial Revolution based on case-based learning. In this study, general cases and occupational cases were developed, and research tools were developed to verify the effectiveness of the occupational personality education program. The program developed in this study was provided four times for 52 students in the second and third grades college and university. This study was performed with a single group pre-post design. The data were analyzed by means of mean, standard deviation, and paired t-test. By applying the program developed in this study, accountability, honesty, consideration, collaboration, communication, and competency were improved. This confirmed the positive effect of vocational character education

Clinical and Imaging Characteristics of SARS-CoV-2 Breakthrough Infection in Hospitalized Immunocompromised Patients

  • Jong Eun Lee;Jinwoo Kim;Minhee Hwang;Yun-Hyeon Kim;Myung Jin Chung;Won Gi Jeong;Yeon Joo Jeong
    • Korean Journal of Radiology
    • /
    • v.25 no.5
    • /
    • pp.481-492
    • /
    • 2024
  • Objective: To evaluate the clinical and imaging characteristics of SARS-CoV-2 breakthrough infection in hospitalized immunocompromised patients in comparison with immunocompetent patients. Materials and Methods: This retrospective study analyzed consecutive adult patients hospitalized for COVID-19 who received at least one dose of the SARS-CoV-2 vaccine at two academic medical centers between June 2021 and December 2022. Immunocompromised patients (with active solid organ cancer, active hematologic cancer, active immune-mediated inflammatory disease, status post solid organ transplantation, or acquired immune deficiency syndrome) were compared with immunocompetent patients. Multivariable logistic regression analysis was performed to evaluate the effect of immune status on severe clinical outcomes (in-hospital death, mechanical ventilation, or intensive care unit admission), severe radiologic pneumonia (≥ 25% of lung involvement), and typical CT pneumonia. Results: Of 2218 patients (mean age, 69.5 ± 16.1 years), 274 (12.4%), and 1944 (87.6%) were immunocompromised an immunocompetent, respectively. Patients with active solid organ cancer and patients status post solid organ transplantation had significantly higher risks for severe clinical outcomes (adjusted odds ratio = 1.58 [95% confidence interval {CI}, 1.01-2.47], P = 0.042; and 3.12 [95% CI, 1.47-6.60], P = 0.003, respectively). Patient status post solid organ transplantation and patients with active hematologic cancer were associated with increased risks for severe pneumonia based on chest radiographs (2.96 [95% CI, 1.54-5.67], P = 0.001; and 2.87 [95% CI, 1.50-5.49], P = 0.001, respectively) and for typical CT pneumonia (9.03 [95% CI, 2.49-32.66], P < 0.001; and 4.18 [95% CI, 1.70-10.25], P = 0.002, respectively). Conclusion: Immunocompromised patients with COVID-19 breakthrough infection showed an increased risk of severe clinical outcome, severe pneumonia based on chest radiographs, and typical CT pneumonia. In particular, patients status post solid organ transplantation was specifically found to be associated with a higher risk of all three outcomes than hospitalized immunocompetent patients.

Implementation of Radiotherapy Educational Contents Using Virtual Reality (가상현실 기술을 활용한 방사선치료 교육 콘텐츠 제작 구현)

  • Kwon, Soon-Mu;Shim, Jae-Goo;Chon, Kwon-Su
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.3
    • /
    • pp.409-415
    • /
    • 2018
  • The development of smart devices has brought about significant changes in daily life and one of the most significant changes is the virtual reality zone. Virtual reality is a technology that creates the illusion that a 3D high-resolution image has already been created using a display device just like it does in itself. Unrealized subjects are forced to rely on audiovisual materials, resulting in a decline in the concentration of practices and the quality of classes. It used virtual reality to develop effective teaching materials for radiology students. In order to produce a video clip bridge using virtual reality, a radiology clinic was selected to conduct two exposures from July to September 2017. The video was produced taking into account the radiology and work flow chart and filming was carried out in two separate locations : in the computerized tomography unit and in the LINAC room. Prior to filming the scenario and the filming route were checked in advance to facilitate editing of the video. Modeling and mapping was performed in a PC environment using the Window XP operating system. Using two leading virtual reality camera Gopro Hero, CC pixels were produced using a 4K UHD, Adobe, followed by an 8 megapixel resolution of $3,840{\times}2,160/4,096{\times}2,160$. Total regeneration time was performed in about 5 minutes during the production of using virtual reality to prevent vomiting and dizziness. Currently developed virtual reality radiation and educational contents are being used to secure the market and extend the promotion process to be used by various institutions. The researchers will investigate the satisfaction level of radiation and educational contents using virtual reality and carry out supplementary tasks depending on the results.

Evaluation of the dose distribution in Mapcheck using Enhanced Dynamic Wedge (Enhanced Dynamic Wedge를 사용한 Mapcheck에서의 선량분포 평가)

  • Kang, Su-Man;Jang, Eun-Sun;Lee, Byung-Koo;Jung, Bong-Jae;Shin, Jung-Sub;Park, Cheol-Woo
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.5
    • /
    • pp.343-349
    • /
    • 2012
  • Intensity Modulated Radiotherapy (IMRT) is increasing its use recently due to its benefits of minimizing the dose on surrounding normal organs and being able to target a high dose specifically to the tumor. The study aims to measure and evaluate the dose distribution according to its dynamic changes in Mapcheck. In order to verify the dose distribution by EDW angle($10^{\circ}$,$15^{\circ}$,$20^{\circ}$,$25^{\circ}$,$30^{\circ}$,$45^{\circ}$,$60^{\circ}$), field size (asymmetric field) and depth changes (1.5 cm, 5.0 cm) using IMRT in Clinac ix, a solid phantom was placed on the Mapcheck and 100MU was exposed by 6 MV, 10MV X-ray. Using a 6MV, 10MV energy, the percentage depth dose according to a dynamic changes at a maximum dose depth (1.5 cm) and at 5.0 cm depth showed the value difference of maximum 0.6%, less than 1%, which was calculated by a treatment program device considering the maximum dose depth at the center as 100%, the percentage depth dose was in the range between 2.4% and 7.2%. Also, the maximum value difference of a percentage depth dose was 4.1% in Y2-OUT direction, and 1.7% in Y1-IN direction. When treating a patient using a wedge, it is considered that using an enhanced dynamic wedge is effective to reduce the scattered dose which induces unnecessary dose to the surroundings. In particular, when treating a patient at clinic, a treatment must be performed considering that the wedge dose in a toe direction is higher than the dose in a heel direction.