• 제목/요약/키워드: Radiation exposure dose management

검색결과 156건 처리시간 0.028초

한국 노인의 일반촬영 이용량 및 피폭선량: 2016년 고령환자데이터 기반 (General Radiography Usage and Exposure Dose of Korean Elderly: Based on Data from Aged Patients in 2016)

  • 길종원;유세종;이원정
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권5호
    • /
    • pp.495-502
    • /
    • 2021
  • This study aims to provide basic data for elderly health insurance policy and medical radiation safety management by analyzing the general radiography usage and exposure dose of the elderly in Korea. The effective dose for each general radiography was calculated using the ALARA-GR program for 260 general radiography codes selected from 'National Health Insurance Care Benefit Cost'. The usage of general radiography was analyzed in the 2016 elderly patient data of the Health Insurance Review and Assessment Service, and the effective dose for each general radiography was applied. The general radiography usage and exposure dose per person aged 65 years and over was 6.47 cases and 0.56 mSv. Females showed higher value than males as 7.15 cases and 0.66 mSv(p<.001). By age, those between 75 and 79 showed the highest number as 6.97 cases and 0.62 mSv(p<.001). Those who were supported by Medical Aid showed higher value than those who were insured by National Health Insurance as 8.82 cases and 0.76 mSv(p<.001). In addition, the ratio by radiography was in the order of Chest 20.85%, Knee Joint 15.58%, and L-spine 14.67%, and the exposure dose was L-spine 29.40%, Chest 15.82%, Abdomen 7.97%, and Entire Spine 7.20%. General radiography, which is widely used due to the high frequency of diseases in the elderly population should be taken into consideration when establishing health insurance policies. In addition, it is necessary to check whether the general radiography with high exposure dose is performed as a routine examination without considering medical necessity.

형광유리선량계의 계측 직선성 연구 (A Study on the Measurement Linearity of Photoluminescent Dosimeter)

  • 정경환;정동경;서정민
    • 한국방사선학회논문지
    • /
    • 제15권6호
    • /
    • pp.841-847
    • /
    • 2021
  • 방사선을 이용하는 관련 기관은 국내에 연구, 의료, 교육 등 다양하다. 최근에는 검진 및 의료기관의 방문 횟수가 증가하고 있다. 이로 인해 의료기관에서 방사선학적 검사 횟수가 증가하고 있다. 방사선작업종사자의 피폭뿐만 아니라 방사선 안전관리가 필요하다. 안전관리를 위해서 우선적으로 개인피폭선량계의 올바른 착용 및 착용 후 정확한 측정이 필요하다. 본 연구는 진단용 방사선발생장치의 방사선에 의한 PLD 소자의 계측 직선성을 평가하고 검증하려고 한다. 방사선 분할 조사 시간간격은 10, 30, 60 sec로 10회 조사와 거리에 따라 흡수선량 변화를 측정하기 위해서 조사거리를 30 ~ 100 cm까지 10 cm 간격으로 조사 후 측정하였다. 그 결과 시간 간격에 의한 흡수선량은 차이가 없었다. 이는 고흡수선량 연구에 진단용발생장치를 이용하여 다양한 연구에 도움이 될 것으로 여겨진다.

환자 이송원의 피폭선량 측정 (A Measurement of Exposure Dose for Patient Transporter)

  • 송채림;이왕희;안성민
    • 한국방사선학회논문지
    • /
    • 제13권3호
    • /
    • pp.433-438
    • /
    • 2019
  • 의료기관에서는 환자의 진단 및 치료를 위해 방사선발생장치 및 방사성동위원소를 사용하고 있다. 환자이송원은 환자이송을 위해 불가피하게 방사선 관리구역에 출입하거나, 동위원소가 투여된 환자를 근거리에서 이송하는 등 일반인과 비교했을 때, 방사선에 노출될 확률이 높은 환경에서 업무를 수행한다. 따라서 환자이송원의 피폭 정도를 알아보고자 연구를 진행했다. 인천 A 종합병원에서 근무하고 있는 12명의 환자이송원을 대상으로 2019년 4월 1일부터 4월 30일까지 한 달 동안 선량계를 가슴에 패용하고, 누적된 선량을 측정했다. 사용된 선량계는 광자극발광선량계(OSLD), 선량판독은 OSLD Microstar Reading System을 사용했다. 한 달 동안 누적선량 측정 결과 심부선량은 평균 0.13 mSv, 표층선량은 평균 0.13 mSv로 측정되었고, 한 달 동안 누적된 선량에 12를 곱해 일 년 동안 업무를 수행할 시 받게 될 누적선량 예상치를 추정한 결과 심부선량은 평균 1.52 mSv, 표층선량은 평균 1.51 mSv로 나타났다. 환자이송원의 수시출입자 분류를 통해 피폭선량을 측정, 관리 하고, 교육훈련을 통해 방사선에 대한 방호지식을 높이며 건강진단을 통해 방사선장해 발생을 방지하기 위한 노력이 필요하다.

국내 석탄화력발전소 내 작업종사자의 입자 흡입에 따른 내부피폭 방사선량 평가 (Assessment of Internal Radiation Dose Due to Inhalation of Particles by Workers in Coal-Fired Power Plants in Korea)

  • 이도연;진용호;곽민우;김지우;김광표
    • 방사선산업학회지
    • /
    • 제17권2호
    • /
    • pp.161-172
    • /
    • 2023
  • Coal-fired power plants handle large quantities of coal, one of the most prominent NORM, and the coal ash produced after the coal is burned can be tens of times more radioactive than the coal. Workers in these industries may be exposed to internal exposure by inhalation of particles while handling NORM. This study evaluated the size, concentration, particle shape and density, and radioactivity concentrations of airborne suspended particles in the main processes of a coal-fired power plant. Finally, the internal radiation dose to workers from particle inhalation was evaluated. For this purpose, airborne particles were collected by size using a multi-stage particle collector to determine the size, shape, and concentration of particles. Samples of coal and coal ash were collected to measure the density and radioactivity of particles. The dose conversion factor and annual radionuclide inhalation amount were derived based on the characteristics of the particles. Finally, the internal radiation dose due to particle inhalation was evaluated. Overall, the internal radiation dose to workers in the main processes of coalfired power plants A and B ranged from 1.47×10-5~1.12×10-3 mSv y-1. Due to the effect of dust generated during loading operations, the internal radiation dose of fly ash loading processes in both coal-fired power plants A and B was higher than that of other processes. In the case of workers in the coal storage yard at power plants A and B, the characteristic values such as particle size, airborne concentration, and working time were the same, but due to the difference in radioactivity concentration and density depending on the origin of the coal, the internal radiation dose by origin was different, and the highest was found when inhaling coal imported from Australia among the five origins. In addition, the main nuclide contributing the most to the internal radiation dose from the main processes in the coal-fired power plants was thorium due to differences in dose conversion factors. However, considering the external radiation dose of workers in coal-fired power plants presented in overseas research cases, the annual effective dose of workers in the main processes of power plants A and B does not exceed 1mSv y-1, which is the dose limit for the general public notified by the Nuclear Safety Act. The results of this study can be utilized to identify the internal exposure levels of workers in domestic coal-fired power plants and will contribute to the establishment of a data base for a differential safety management system for NORM-handling industries in the future.

The radiation safety education and the pain physicians' efforts to reduce radiation exposure

  • Kim, Tae Hee;Hong, Seung Wan;Woo, Nam Sik;Kim, Hae Kyoung;Kim, Jae Hun
    • The Korean Journal of Pain
    • /
    • 제30권2호
    • /
    • pp.104-115
    • /
    • 2017
  • Background: C-arm fluoroscopy equipment is important for interventional pain management and can cause radiation injury to physicians and patients. We compared radiation safety education and efforts to reduce the radiation exposure of pain specialists. Methods: A survey of 49 pain specialists was conducted anonymously in 2016. The questionnaire had 16 questions. That questionnaire was about radiation safety knowledge and efforts to reduce exposure. We investigated the correlation between radiation safety education and efforts of radiation protection. We compared the results from 2016 and a published survey from 2011. Results: According to the 2016 survey, all respondents used C-arm fluoroscopy in pain interventions. Nineteen respondents (39%) had received radiation safety education. Physicians had insufficient knowledge about radiation safety. When the radiation safety education group and the non-education group are compared, there was no significant difference in efforts to reduce radiation exposure and radiation safety knowledge. When the 2011 and 2016 surveys were compared, the use of low dose mode (P = 0.000) and pulsed mode had increased significantly (P = 0.001). The number checking for damage to radiation protective garments (P = 0.000) and use of the dosimeter had also increased significantly (P = 0.009). But there was no significant difference in other efforts to reduce radiation exposure. Conclusions: Pain physicians seem to lack knowledge of radiation safety and the number of physicians receiving radiation safety education is low. According to this study, education does not lead to practice. Therefore, pain physicians should receive regular radiation safety education and the education should be mandatory.

진단용 방사선발생장치의 검사기준을 적용한 동물병원의 방사선 안전관리 (The Radiation Safety Management in the Animal Hospital Using Inspection Standard of Diagnosis Radiation System)

  • 김상우;임재동;한동균;성열훈
    • 대한안전경영과학회지
    • /
    • 제12권4호
    • /
    • pp.73-80
    • /
    • 2010
  • The purpose of this study was to investigate the actual conditions of radiation safety supervision in animal clinics using inspection standard of X-ray generator for diagnosis. The surveys for inspection standard system, equipment condition, and safety supervision were carried out in 18 animal clinics randomly. The inspection standard included reproducibility of dose exposure, kVp, mAs, collimator accuracy test, collimator luminance test, X-ray view box luminance test, grounding system equipment test and external leakage current test. The surveys of equipment condition and safety supervision used one-on-one interview with 5 points measurement. As a result, 44.44% of reproducibility of dose exposure was proper, 81.25% of kVp test was good, and 100% of mAs test was appropriate. Also, 66.66% of collimator accuracy test was proper, 61.11% of collimator luminance test was good, 53.13% of X-ray view box luminance test was suitable. In addition, only 5.55% of grounding system equipment and ground resistance was proper, 63.64% of external leakage current test was appropriate in grounding system equipment test. The 100mA electric capacity of X-ray generator for diagnosis was popular with 44.44%, and its 55.56% was purchased used equipment. Monthly average of less than 50 times (61.11%) was top frequency in use, and no animal clinic had a thermo-luminescence dosimeter(TLD). The 16 animal clinics with radiation safety zone and 2 without radiation safety zone were appeared.

일개 대학병원의 수시출입자와 방사선작업종사자의 피폭선량에 관한 고찰 (A Study on the Exposure Dose of Frequent Workers and Radiation Workers in a University Hospital)

  • 이주아
    • 한국방사선학회논문지
    • /
    • 제17권4호
    • /
    • pp.581-587
    • /
    • 2023
  • 본 연구에서는 인천 C대학병원에서 방사선작업종사자와 수시출입자의 피폭선량을 비교 분석하여 방사선 안전관리를 위한 기초 자료를 제공하고자 하였다. 2021년 1월부터 2022년 12월까지 인천 소재 C대학병원에서 근무하는 방사선작업종사자 30명과 수시출입자 8명을 대상으로 표면선량과 심부선량을 분석하였다. 방사선작업종사자는 방사선종양학과와 핵의학과에서 근무하는 방사선사 및 간호사를 대상으로 하였으며, 수시출입자는 동일 방사선관리구역 내 시설관리 및 청소업무를 수행하는 수시출입자를 대상으로 하였다. 방사선작업종사자는 방사선사 100,000당 3.1명, 간호사 100,000당 1.2명, 수시출입자 1,000,000당 4.5명이 폐에 부작용이 생길 가능성을 보였다. 방사선종양학과의 방사선사는 10,000당 1.1명, 간호사의 경우 1,000,000명당 5.2명이었고, 핵의학과의 방사선사는 10,000명당 2.9명, 간호사의 경우 1,000,000명당 7.1명이었다. 본 연구가 향후 수시출입자에 관한 개정 시 기초자료로 활용될 수 있기를 바라며, 향후 방사선의 확률론적 영향과 관련된 장해 분야의 기초자료로 활용될 수 있을 것으로 생각된다.

대학 내 학습공간과 공동 생활공간에 대한 실내 라돈 농도 측정과 유효선량 산출 (Indoor Radon Levels and Effective Dose Estimation in Learning and Common Living Space of University)

  • 김정수
    • 한국방사선학회논문지
    • /
    • 제12권3호
    • /
    • pp.329-334
    • /
    • 2018
  • 라돈은 자연방사성원소로 호흡을 통해 인체에 피폭된다. 본 연구에서는 2017년 6월 1일부터 2017년 8월 28일까지 3개월 동안 A대학의 8개 건축물에 대해 실내 라돈농도를 측정하여 비교하였고, 연간 유효선량을 도출하였다. 본 연구에서 A대학의 건축물 Hall G와 Hall F의 라돈농도는 각각 $81Bq/m^3$, $14Bq/m^3$로 나타났으며, 전체 조사 건축물의 평균 실내 라돈농도는 $41.63Bq/m^3$로 나타났다. 대학 내 학습공간과 생활공간에 대한 연간 유효선량 환산치의 평균은 0.40 mSv/y이며 최대 연간 유효선량은 0.78 mSv/y, 최소 연간 유효선량은 0.13 mSv/y로 나타났다. 학교는 학생들이 오랜 시간 머무르는 공간이므로 건축물에 대한 적절한 환기와 관리를 통해 실내라돈 농도를 낮추는 것이 라돈에 대한 자연방사선 피폭을 낮추는 방법이다.

자체제작 Pb 밴딩을 이용한 피폭선량 감소 (Exposure dose Reduction using Pb Banding of own manufacturing)

  • 김창규
    • 디지털융복합연구
    • /
    • 제11권6호
    • /
    • pp.269-273
    • /
    • 2013
  • 치과 진료시 파노라마 장치를 이용한 검사에서 유리선량계를 사용하여 피검자의 피폭선량을 측정하였다. 특히 방사선에 민감한 수정체의 피폭선량을 줄이기 위하여 자체 제작한 Pb밴딩의 크기에 따라 수정체 피폭선량을 측정한 결과 Pb밴딩의 크기에 따라서 수정체의 피폭선량이 다르다는 것을 확인할 수 있었다. Pb밴딩의 크기가 $3{\times}20{\times}0.2cm$에서는 정상치보다 피폭선량이 증가하는 경향을 보였으며 $5{\times}20{\times}0.2cm$ 이상의 크기에서는 피폭선량이 감소하는 결과를 보였다. 또한 획득되어진 영상 $7{\times}20{\times}0.2cm$ 크기에서 진단에 부적합한 영상으로 판정되었다. 그러므로 피폭선량을 최소화하고 효과적인 파노라마 검사를 수행하기 위해서는 Pb밴딩 $5{\times}20{\times}0.2cm$이상 $6{\times}20{\times}0.2cm$이하 크기를 사용하여 검사에 활용하면 피폭선량이 감소될 것으로 기대한다.

몬테카를로 방법을 이용한 중재방사선시술자에 대한 선량평가 (Assessment of Occupational Dose to the Staff of Interventional Radiology Using Monte Carlo Simulations)

  • 임영기
    • Journal of Radiation Protection and Research
    • /
    • 제39권4호
    • /
    • pp.213-217
    • /
    • 2014
  • 중재방사선을 이용한 의료적 시술이나 진단은 꾸준히 증가하고 있다. 특히 환자에 근접하여 이루어지는 중재방사선시술의 특성상 시술자에 대한 직무피폭의 관리 및 감시가 중요하다. 개인선량계를 통해 측정되는 방사선 방호 실용량인 심부선량은 중재방사선시술의 경우 균질한 방사선장에 의해 전신에 고르게 노출되는 경우가 아니므로 유효선량을 항상 대표할 수는 없다. 따라서 본 연구에서는 C-arm을 이용한 대표적인 중재방사선시술에 대해 수학적 모의피폭체와 몬테카를로 방법을 이용한 계산과 개인선량계를 이용한 실측을 통해 개인선량당량과 장기별 선량을 평가하고자 하였다. 주요 장기별 선량평가 결과는 개인선량계로 측정된 선량 값보다 낮았으나, 갑상선과 같은 장기는 전신 연조직 선량보다 상당히 높은 것으로 평가되었다. 중재방사선시술자에 대한 적절한 방사선방호를 위해 납치마의 착용과 같은 전신 방호와 더불어 갑상선 방호와 같은 추가적인 방호조치가 고려되어야 할 것이다.