Abstract

Background: C-arm fluoroscopy equipment is important for interventional pain management and can cause radiation injury to physicians and patients. We compared radiation safety education and efforts to reduce the radiation exposure of pain specialists. Methods: A survey of 49 pain specialists was conducted anonymously in 2016. The questionnaire had 16 questions. That questionnaire was about radiation safety knowledge and efforts to reduce exposure. We investigated the correlation between radiation safety education and efforts of radiation protection. We compared the results from 2016 and a published survey from 2011. Results: According to the 2016 survey, all respondents used C-arm fluoroscopy in pain interventions. Nineteen respondents (39%) had received radiation safety education. Physicians had insufficient knowledge about radiation safety. When the radiation safety education group and the non-education group are compared, there was no significant difference in efforts to reduce radiation exposure and radiation safety knowledge. When the 2011 and 2016 surveys were compared, the use of low dose mode (P = 0.000) and pulsed mode had increased significantly (P = 0.001). The number checking for damage to radiation protective garments (P = 0.000) and use of the dosimeter had also increased significantly (P = 0.009). But there was no significant difference in other efforts to reduce radiation exposure. Conclusions: Pain physicians seem to lack knowledge of radiation safety and the number of physicians receiving radiation safety education is low. According to this study, education does not lead to practice. Therefore, pain physicians should receive regular radiation safety education and the education should be mandatory.

Keywords

References

  1. Sheyn DD, Racadio JM, Ying J, Patel MN, Racadio JM, Johnson ND. Efficacy of a radiation safety education initiative in reducing radiation exposure in the pediatric IR suite. Pediatr Radiol 2008; 38: 669-74. https://doi.org/10.1007/s00247-008-0826-9
  2. Kim S, Shin JH, Lee JW, Kang HS, Lee GY, Ahn JM. Factors affecting radiation exposure during lumbar epidural steroid injection: a prospective study in 759 patients. Korean J Radiol 2016; 17: 405-12. https://doi.org/10.3348/kjr.2016.17.3.405
  3. Fishman SM, Smith H, Meleger A, Seibert JA. Radiation safety in pain medicine. Reg Anesth Pain Med 2002; 27: 296-305. https://doi.org/10.1097/00115550-200205000-00012
  4. Broadman LM, Navalgund YA, Hawkinberry DW 2nd. Radiation risk management during fluoroscopy for interventional pain medicine physicians. Curr Pain Headache Rep 2004; 8: 49-55. https://doi.org/10.1007/s11916-004-0040-x
  5. Schueler BA. Operator shielding: how and why. Tech Vasc Interv Radiol 2010; 13: 167-71. https://doi.org/10.1053/j.tvir.2010.03.005
  6. Ryu JS, Baek SW, Jung CH, Cho SJ, Jung EG, Kim HK, et al. The survey about the degree of damage of radiationprotective shields in operation room. Korean J Pain 2013; 26: 142-7. https://doi.org/10.3344/kjp.2013.26.2.142
  7. Cho JH, Kim JY, Kang JE, Park PE, Kim JH, Lim JA, et al. A study to compare the radiation absorbed dose of the C-arm fluoroscopic modes. Korean J Pain 2011; 24: 199-204. https://doi.org/10.3344/kjp.2011.24.4.199
  8. Baek SW, Ryu JS, Jung CH, Lee JH, Kwon WK, Woo NS, et al. A randomized controlled trial about the levels of radiation exposure depends on the use of collimation C-arm fluoroscopic-guided medial branch block. Korean J Pain 2013; 26: 148-53. https://doi.org/10.3344/kjp.2013.26.2.148
  9. Kim AN, Chang YJ, Cheon BK, Kim JH. How effective are radiation reducing gloves in C-arm fluoroscopy-guided pain interventions? Korean J Pain 2014; 27: 145-51. https://doi.org/10.3344/kjp.2014.27.2.145
  10. Park PE, Park JM, Kang JE, Cho JH, Cho SJ, Kim JH, et al. Radiation safety and education in the applicants of the final test for the expert of pain medicine. Korean J Pain 2012; 25: 16-21. https://doi.org/10.3344/kjp.2012.25.1.16
  11. Cousins C, Sharp C. Medical interventional proceduresreducing the radiation risks. Clin Radiol 2004; 59: 468-73. https://doi.org/10.1016/j.crad.2003.11.014
  12. Ploussi A, Efstathopoulos EP. Importance of establishing radiation protection culture in radiology department. World J Radiol 2016; 8: 142-7. https://doi.org/10.4329/wjr.v8.i2.142
  13. Mahajan A, Samuel S, Saran AK, Mahajan MK, Mam MK. Occupational radiation exposure from C arm fluoroscopy during common orthopaedic surgical procedures and its prevention. J Clin Diagn Res 2015; 9: RC01-4. https://doi.org/10.1111/crj.12091
  14. Wagner M, Duwenkamp C, Ludwig W, Dresing K, Bott OJ. An approach to simulate and visualize intraoperative scattered radiation exposure to improve radiation protection training. Stud Health Technol Inform 2010; 160: 625-8.
  15. Yamashita K, Higashino K, Wada K, Morimoto M, Abe M, Takata Y, et al. Radiation exposure to the surgeon and patient during a fluoroscopic procedure: how high is the exposure dose? A cadaveric study. Spine (Phila Pa 1976) 2016; 41: 1254-60. https://doi.org/10.1097/BRS.0000000000001542
  16. Meisinger QC, Stahl CM, Andre MP, Kinney TB, Newton IG. Radiation protection for the fluoroscopy operator and staff. AJR Am J Roentgenol 2016 [in press].
  17. Zhou Y, Singh N, Abdi S, Wu J, Crawford J, Furgang FA. Fluoroscopy radiation safety for spine interventional pain procedures in university teaching hospitals. Pain Physician 2005; 8: 49-53.
  18. Nicol AL, Benzon HT, Liu BP. Radiation exposure in interventional pain management: we still have much to learn. Pain Pract 2015; 15: 389-92. https://doi.org/10.1111/papr.12290
  19. Frazier TH, Richardson JB, Fabre VC, Callen JP. Fluoroscopy-induced chronic radiation skin injury: a disease perhaps often overlooked. Arch Dermatol 2007; 143: 637-40.
  20. Mettler FA Jr, Koenig TR, Wagner LK, Kelsey CA. Radiation injuries after fluoroscopic procedures. Semin Ultrasound CT MR 2002; 23: 428-42. https://doi.org/10.1016/S0887-2171(02)90014-4
  21. Dorr W. Radiobiology of tissue reactions. Ann ICRP 2015; 44: 58-68. https://doi.org/10.1177/0146645314560686
  22. Killewich LA, Singleton TA. Governmental regulations and radiation exposure. J Vasc Surg 2011; 53: 44S-46S.
  23. Chambers CE, Fetterly KA, Holzer R, Lin PJ, Blankenship JC, Balter S, et al. Radiation safety program for the cardiac catheterization laboratory. Catheter Cardiovasc Interv 2011; 77: 546-56. https://doi.org/10.1002/ccd.22867

Cited by

  1. Radiation safety: a focus on lead aprons and thyroid shields in interventional pain management vol.31, pp.4, 2018, https://doi.org/10.3344/kjp.2018.31.4.244
  2. Three principles for radiation safety: time, distance, and shielding vol.31, pp.3, 2018, https://doi.org/10.3344/kjp.2018.31.3.145
  3. Radiation exposure and protection for eyes in pain management vol.12, pp.4, 2017, https://doi.org/10.17085/apm.2017.12.4.297
  4. Thyroidology and public health: Challenges within the medical profession vol.16, pp.3, 2017, https://doi.org/10.4103/trp.trp_40_19
  5. 원자력안전법 수시출입자 안전관리체계 개편에 대한 방사선학과 재학생들의 융합적 인식 연구 vol.10, pp.6, 2017, https://doi.org/10.15207/jkcs.2019.10.6.089